Fixed Aerosol Fire-Extinguishing System Experience with Gov. Required 3 Year (s) Fixed Aerosol Fire-Extinguishing System ( 5 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Non Pyrotechnic Condensed Aerosol Generator Fixed Aerosol Fire- Extinguishing Systems Generally in compliance to NFPA:2010 and UL2775(UL Listed) Generally in compliance to NFPA:2010 and UL2775(UL Listed) Volume of the Room enclosure for which system is suitable 1.8 * Non Pyrotechnic Automatic activation Mechanism Extinguishant Controller capable of detecting fire by using Bimetallic Sensor and activating the condensed aerosol fire extinguishing units automatically
support one aerosol generator. Bulb Thermal Actuator- Working principle. The activation of the unit is achieved thermally by the use of the Bulb Thermal Actuator (BTA).
Extinguishant Controller capable of detecting fire by using Bimetallic Sensor and activating the condensed aerosol fire extinguishing units 1/6 automatically
support one aerosol generator.
Extinguishant Controller is capable of detecting fire by using the linear heat detection cable and activating the condensed aerosol fire extinguising units automatically
support two aerosol generator. with Feedback Fire Signal and Power Cut off Capabilities Mounting of Generator Magnet * CONSTRUCTIONAL Quantity of Condensed Aerosol in one unit 200 * Gross Weight of the unit without bracket 1840 Any applicable numeric value Dimensions for Aerosol Generator unit 185mm x 84 mm (including connector housing) * Effective space volume covered by one unit 1.8 * Discharge outlet 1 * Material of Aerosol Housing STAINLESS STEEL ALUMINUM ALLOY
STAINLESS STEEL
MILD STEEL ACCESSORIES Sequential Activator false * Number of Sequential Activator required NA * Isolator Switch(for isolating the main feeding line of aerosol gen) as per EN54 false * Number of Isolator Switch(for isolating the main feeding line of aerosol gen) required NA * XLPE Cable 2Core X 3/2 N/A * 2/6 sqmm duly ISI marked to IS:7098/Pt-1 latest( select NA if not applicable) Length of XLPE Cable 2Core X 3/2 sqmm required (write NA if not applicable) (mtr) NA * 1st stage aduible alaram bell as per UL LISTED/EN 54 false * Number of 1st stage aduible alaram bell required (write NA if not applicable) NA * 2nd stage aduible alaram with strobe light UL LISTED/EN 54 false * Number of 2nd stage aduible alaram with strobe light required (write NA if not applicable) NA * Illumination Sign false * Number of Illumination Sign Required (write NA if not applicable) NA * Voice Dialer false * Number of Voice Dialer (write NA if not applicable) NA * Smoke Detectors UL LISTED/EN 54 false * Number of Smoke Detectors Required (write NA if not applicable) NA * Heat Detectors UL LISTED/EN 54 false * Number of Heat Detectors Required (write NA if not applicable) NA * Linear Heat Cable UL LISTED/EN 54 false * Length of Linear Heat Cable required UL LISTED/EN 54 (write NA if not applicable) NA * 3/6 Linear Heat Cable Connector Box false * Number of Linear Heat Cable Connector Box Required (write NA if not applicable) NA * Control panel for system UL/EN 54/EN 12094 false * Number of Control panel for system required (write NA if not applicable) NA * PERFORMANCE Design application Density of aerosol compound for fire class A as per UL 2775 (Extinguishing application density
including 30% safety factor
required for system design purposes) (gram/meter3) 109.2 Any applicable text(s) Activation Temperature Range (Thermally activated Aerosol Fire Extinguisher) 100 degree celsius * Envorimental operating conditions (OPERATING TEMP) -54 to +54 degree celsius * Operational discharge time ( as per UL ) 5-10 seconds * Discharge length 2 * CERTIFICATION Product lifespan period should be declared as per UL 15 * Fire Extinguishing Activator should meet the EMC requirement as per EN 61000-6-1 (Part 6-1 & Part 6-3:2007) Yes * Aerosol Generator should be suitable for marine applications with wheel mark true true
false Availability of complete Test Report as per NFPA 2010
and Yes * 4/6 UL2775 certification to prove confirmity of product for declared parameters Test Report No and Date - * Name and Address of the Lab - * Test Reports to be furnished to the buyer on demand including certification for chemical used being non pyrotechnic non explosive Yes Yes Availability of any other certification (CE/UL/TUV BSI/MED/any other a) Global Ecolabelling Network Member
b) EPA SNAP
c) KEMA Report “50151217-KPS/TPE 02-6144
d) BSI/MED/PC/560437 Module D Dt. 16.11.17 * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 CONTRACTS AND MATERIAL MANAGE DIRECTOR 500069
RESEARCH CENTRE IMARAT
P O VIGNYANA KANCHA 5 15
546736
GEM/2018/B/77523
Fixed Aerosol Fire-Extinguishing System
15 days
Telangana; Ranga Reddy
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Fixed Aerosol Fire-Extinguishing System Experience with Gov. Required 3 Year (s) Fixed Aerosol Fire-Extinguishing System ( 5 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Non Pyrotechnic Condensed Aerosol Generator Fixed Aerosol Fire- Extinguishing Systems Generally in compliance to NFPA:2010 and UL2775(UL Listed) Generally in compliance to NFPA:2010 and UL2775(UL Listed) Volume of the Room enclosure for which system is suitable 1.8 * Non Pyrotechnic Automatic activation Mechanism Extinguishant Controller capable of detecting fire by using Bimetallic Sensor and activating the condensed aerosol fire extinguishing units automatically | - | - | - |
| support one aerosol generator. Bulb Thermal Actuator- Working principle. The activation of the unit is achieved thermally by the use of the Bulb Thermal Actuator (BTA). | - | - | - |
| Extinguishant Controller capable of detecting fire by using Bimetallic Sensor and activating the condensed aerosol fire extinguishing units 1/6 automatically | - | - | - |
| support one aerosol generator. | - | - | - |
| Extinguishant Controller is capable of detecting fire by using the linear heat detection cable and activating the condensed aerosol fire extinguising units automatically | - | - | - |
| support two aerosol generator. with Feedback Fire Signal and Power Cut off Capabilities Mounting of Generator Magnet * CONSTRUCTIONAL Quantity of Condensed Aerosol in one unit 200 * Gross Weight of the unit without bracket 1840 Any applicable numeric value Dimensions for Aerosol Generator unit 185mm x 84 mm (including connector housing) * Effective space volume covered by one unit 1.8 * Discharge outlet 1 * Material of Aerosol Housing STAINLESS STEEL ALUMINUM ALLOY | - | - | - |
| STAINLESS STEEL | - | - | - |
| MILD STEEL ACCESSORIES Sequential Activator false * Number of Sequential Activator required NA * Isolator Switch(for isolating the main feeding line of aerosol gen) as per EN54 false * Number of Isolator Switch(for isolating the main feeding line of aerosol gen) required NA * XLPE Cable 2Core X 3/2 N/A * 2/6 sqmm duly ISI marked to IS:7098/Pt-1 latest( select NA if not applicable) Length of XLPE Cable 2Core X 3/2 sqmm required (write NA if not applicable) (mtr) NA * 1st stage aduible alaram bell as per UL LISTED/EN 54 false * Number of 1st stage aduible alaram bell required (write NA if not applicable) NA * 2nd stage aduible alaram with strobe light UL LISTED/EN 54 false * Number of 2nd stage aduible alaram with strobe light required (write NA if not applicable) NA * Illumination Sign false * Number of Illumination Sign Required (write NA if not applicable) NA * Voice Dialer false * Number of Voice Dialer (write NA if not applicable) NA * Smoke Detectors UL LISTED/EN 54 false * Number of Smoke Detectors Required (write NA if not applicable) NA * Heat Detectors UL LISTED/EN 54 false * Number of Heat Detectors Required (write NA if not applicable) NA * Linear Heat Cable UL LISTED/EN 54 false * Length of Linear Heat Cable required UL LISTED/EN 54 (write NA if not applicable) NA * 3/6 Linear Heat Cable Connector Box false * Number of Linear Heat Cable Connector Box Required (write NA if not applicable) NA * Control panel for system UL/EN 54/EN 12094 false * Number of Control panel for system required (write NA if not applicable) NA * PERFORMANCE Design application Density of aerosol compound for fire class A as per UL 2775 (Extinguishing application density | - | - | - |
| including 30% safety factor | - | - | - |
| required for system design purposes) (gram/meter3) 109.2 Any applicable text(s) Activation Temperature Range (Thermally activated Aerosol Fire Extinguisher) 100 degree celsius * Envorimental operating conditions (OPERATING TEMP) -54 to +54 degree celsius * Operational discharge time ( as per UL ) 5-10 seconds * Discharge length 2 * CERTIFICATION Product lifespan period should be declared as per UL 15 * Fire Extinguishing Activator should meet the EMC requirement as per EN 61000-6-1 (Part 6-1 & Part 6-3:2007) Yes * Aerosol Generator should be suitable for marine applications with wheel mark true true | - | - | - |
| false Availability of complete Test Report as per NFPA 2010 | - | - | - |
| and Yes * 4/6 UL2775 certification to prove confirmity of product for declared parameters Test Report No and Date - * Name and Address of the Lab - * Test Reports to be furnished to the buyer on demand including certification for chemical used being non pyrotechnic non explosive Yes Yes Availability of any other certification (CE/UL/TUV BSI/MED/any other a) Global Ecolabelling Network Member | - | - | - |
| b) EPA SNAP | - | - | - |
| c) KEMA Report “50151217-KPS/TPE 02-6144 | - | - | - |
| d) BSI/MED/PC/560437 Module D Dt. 16.11.17 * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 CONTRACTS AND MATERIAL MANAGE DIRECTOR 500069 | - | - | - |
| RESEARCH CENTRE IMARAT | - | - | - |
| P O VIGNYANA KANCHA 5 15 | - | - | - |
Exempted
3 Sept 2018
31 Aug 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_546736.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .