Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹46.6 L+₹1.5 L (3.42%)Rejected-Finance | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹46.9 L+₹1.8 L (4.07%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹47.0 L+₹1.9 L (4.30%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹48.2 L+₹3.2 L (7.03%)Rejected-Finance NOT AVAILABLE | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
11 Jul 2024, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM PIN-786183
REPAIR REPLACEMENT OF LT EXTERNAL ELECTRIC SUPPLY, DISTRIBUTION NETWORK AT GANESHBARI, NCC, HATIALI, OUTPOCKET AREA AND REPAIR MAINT OF POINT WIRING FIXURES WITH SUB MAIN WIRING, MCBs DBs TO OR, JCOs MD ACCN AND CERTAIN UNITS UNDER GE DINJAN
2024_MES_661206_1
C/8689/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE DINJAN
₹87,000
Yes
21 Sept 2024
21 Jun 2024
18 Jul 2024
21 Jun 2024
11 Jul 2024
5 Jul 2024
Amount
Trimming of tree branches around the overhead conductor, polesand stay (not less than 3 meter ) to clear the approch of overhead lines incl removing of nest, wild grass creepers, unwanted vegetation, etc from pole/stay including clearing of creepers climbed on poles and angles, channels and disposed off from site beyond 50m and upto a total 250m complete all as specified and as directed. Note : Span 30 to 50 meter shall be measured as one unit.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation/cable trench, not exceeding 10Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches exc 1.50 mtr wide and exc 1.5 m but n. exc. 3.0 mtr in depth for taking out/laying of under ground cable, pole or stay and getting out in soft/loose soil, complete all as specified and as directed.
Returning filling including spreading, levelling and well ramming in layers not exceeding 25cm thick in soil complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above starting point complete all as specified and as directed.
M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
Laying only old common brick laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and as directed.
M&L for bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and as directed.
Supply, fabricate and fixing of clamp made of GI strip of size not less than 32 x 6mm (Fe 290, Gde E-165) for support of cable protection pipe of existing size from existing steel / RCC pole of any size by making hole to strip and fixed with suitable size nut bolt and washer etc complete all as specified and as directed.
Supplying and laying synthetic rubber insulated mats for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m and thickness not less than 12mm complete all as specified and as directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for LT, 20 x 15 cm size including taking down of old one complete all as specified and as directed.
Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately.
Laying only old serviceable XLPE insulated, armoured, nominal cross sectional area of main conductor , stranded aluminium conductor, 1100 volt grade, any size, 2/3.5/4 core, to be laid in trenches, under floors, through GI pipe complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, nominal cross sectional area of main conductor 10 Sqmm, 2 core, stranded aluminium conductor,1100 Volt grade, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, nominal cross sectional area of main conductor 16 Sqmm, 2 core, stranded aluminium conductor, 1100 Volt grade, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, nominal cross sectional area of main conductor 16 Sqmm, 4 core, stranded aluminium conductor, 1100 Volt grade, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, nominal cross sectional area of main conductor 25 Sqmm, 3 core with reduced neutral conductor (3 1/2 Core), stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, nominal cross sectional area of main conductor 35 Sqmm, 3 core with reduced neutral conductor (3 1/2 Core), stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, nominal cross sectional area of main conductor 50 Sqmm, 3 core with reduced neutral conductor (3 1/2 Core), stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, nominal cross sectional area of main conductor 95 Sqmm, 3 core with reduced neutral conductor (3 1/2 Core), stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, nominal cross sectional area of main conductor 180 Sqmm, 3 core with reduced neutral conductor (3 1/2 Core), stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, nominal cross sectional area of main conductor 400 Sqmm, 3 core with reduced neutral conductor (3 1/2 Core), stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately.
M&L for stay assembly comprising of 7/8 SWG galvanised stay of standard wire of required length fixed to pole with and including galvanised flat iron clamps, bolts, nuts and washers etc including galvanised steel 14 mm dia, 400 mm long stay bow and GI stay plate of size 300 x 300 x 6 mm thick, thimble MS clamp made out of 50 x 6mm and loop insulators porcelain brown all as shown in EP No.1 of SSR part - I including all accessories and excavation, earth work and PCC work complete all as specified and as directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and stacking aside serviceable materials for re-use with in 50m and removing unserviceable materials from site of work complete all as specified and as directed.
M&L for cross arms bracing supports clamps and back plates fabricated from structural steel sections including nuts, bolts & washers, welding, bending, cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one coat of aluminium paint over one coat of red oxide zinc chrome primer, complete all as specified and as directed.
Dismantling of insulators of any type from LT poles of any size and type and setting aside complete all as specified and as directed.
Supply and fixing pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65mm dia suitable for 1100 volts grade complete all as specified and as directed.
Supply and fixing shackle type, porcelain, insulator vitreous, white, brown or green, including galvanised mild steel, straps, washers, insulator bolts, washers and nuts, 100 mm height and 115 mm dia, size of strap 31 mm x 5 mm and bolt of 14mm dia, suitable for 1100 volts complete all as specified and as directed.
Supply and fixing loop type porcelain vitreous white, brown or green insulator small size, with overall dimensions 65 x 90 mm, clearance of hole 16mm including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, complete all as specified and directed
M&L for cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in pole foundation, filling and mass concrete complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of pole including necessary form work for fair finish surfaces complete all as specified and as directed
Dismantling/taking down old aluminium steel reinforced (ACSR) conductor of any size any type from LT overhead line including all jumper, cross arms, clamps, bolts, nuts etc and keeping serviceable materials in safe custody for reuse in the work complete all as specified and as directed
Supply, fixing and stringing of aluminium conductor steel reinforced (ACSR) conductor of size (a) Squireel 6/1 x 2.11, (b) Weasel 6/1 x 2.59, (c) Rabbit 6/1 x 3.25 as suitable conforming to IS - 398 part- 4 of 1994 including binding, straining in LT over head line including all jumper connection and binding on insulator with new wire/aluminium tape complete all as specified and as directed.
Restringing of old aluminium conductor steel reinforced (ACSR) or AAAC conductor of 4 wire line ( 3 phase and neutral) and make on LT 9 m long poles alongwith earth wire, including replacement of binding wire and aluminium taps reconnection, street light connections, service connections and binding to insulators with suitable size of new binding wire including prunning of tree branches 2 mtr all around OH LT line by means of pulley, rope etc complete all as specified and as directed. Note : 04 Nos of ACSR or AAAC conductor shall be measured as one unit length.
Restringing of old aluminium conductor steel reinforced (ACSR) or AAAC conductor of 2 wire line (single phase and neutral) and make on LT 9 m long poles alongwith earth wire, including replacement of binding wire and aluminium taps reconnection, street light connections, service connections and binding to insulators with suitable size of new binding wire including prunning of tree branches 2 mtr all around OH LT line by means of pulley, rope etc complete all as specified and as directed. Note : 02 Nos of ACSR or AAAC conductor shall be measured as one unit length.
Dismantling existing unserviceable GI earth wire, cradles of any type obtained from service feeder or distributor span complete all as specified and as directed. Note : cost of accessories required for making hole/bore deemed to be included in the quoted rate.
M&L for Galvanised steel wire 3.15 or 4mm dia (hexagonal/ rectangular ) used for cradles guarding, earthing suitable for LT/HT overhead line etc complete all as specified and as directed.
S&F for PVC/fiber separator for LT over head line 1100 volts conductor 3/4 wire system, suitable for 2 conductor, in span without damaging the over head line including taking down old separator complete all as specified and as directed .
S&F for PVC/fiber separator for LT over head line 1100 volts conductor 3/4 wire system, suitable for 4 conductor, in span without damaging the over head line including taking down old separator complete all as specified and as directed .
Boring of holes horizontal for laying not less than 40mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hard standing using trenchless technology complete all as specified and as directed. Note : cost of accessories required for making hole/bore deemed to be included in the quoted rate.
M&L for 32 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in UG cable protection complete to walls and ceilings or laid in floors including taking down old unserviceable pipe alongwith all fixing accessories complete all as specified and as directed.
M&L for 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor /road crossing /drain etc as in protection of UG cable complete to walls and ceilings or laid in floors including taking down old unserviceable complete all as specified and as directed.
M&L for 50 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor /road crossing /drain etc as in protection of UG cable complete to walls and ceilings or laid in floors including taking down old unserviceable complete all as specified and as directed.
M&L for 80 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor /road crossing /drain etc as in protection of UG cable complete to walls and ceilings or laid in floors including taking down old unserviceable complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m below ground level with the top edge of earth plate at depth not less than 1.5m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing the base in which pit cover rests made up of MS angle iron (Frame) complete as specified and as directed.
M&L for earthing with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm dia by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing including taking down old unserviceable complete all as specified and as directed.
S&F CT & PT as per existing ratio at site which can suitably fixed in existing ammeter and voltmeter of LT electric panel at site complete all as specified and as directed.
Dismantling /uprooting of LT/HT unserviceable pre-stressed concrete /steel poles of any size and shape and including taking out dismantled portion of poles embedded in ground after necessary demolition of concrete foundation and making good disturbed ground surface properly and disposal thereof complete all as specified and as directed. Note:- Earth work for taking out poles shall be measured and paid separately under relevant item of this Schedule.
M&L for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including two coats of aluminium paint over a coat of primer except the planting depth which shall be painted with black bituminous paint including writing pole number using suitable paint complete all as specified and as directed. Note : excavation and earth work, PCC filling shall be measured and paid separately.
Dismantling of lightning arresters any type/size for any capacity complete all as specified & directed.
M&L for LT lighting arresters for outdoor, use, non-linear resistor type, horn gap and choking coil, maximum working pressure 1100 volts complete all as specified and as directed.
S&F for 1100 volts grade, heavy duty, cable PVC insulated, aluminium conductor, stranded of size 10 Sqmm x 2 core, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm dia GI suspension wire, one twin core cable flat or circular etc complete all as specified and as directed.
S&F for On load change over switch 800 Amps with enclosure rated voltage 415V-AC 50 Hz, type FP fixed on wall with nut and bolt including taking down complete all as specified and directed.
S&F for On load change over switch 100 Amps with enclosure rated voltage 415V-AC 50 Hz, type FP fixed on wall with nut and bolt including taking down complete all as specified and directed.
S&F for On load change over switch 63 Amps with enclosure rated voltage 415V-AC 50 Hz, type FP fixed on wall with nut and bolt including taking down complete all as specified and directed.
S&F in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw including removing the existing old unserviceable one complete all as specified and as directed.
S&F in replacement of cast iron cable route indicator with embrossing mark as LT cable, circular type 75mm dia duly fixed with suitable size of MS flat iron member to be embedded in PCC (1:3:6) type C1 block size 150 x150x 150mm complete all as specified and as directed.
Supply and fixing LED street light fitting 35/40 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete
Supply and fixing street light bracket made out of GI pipe (light grade) 40 mm dia 1.5 mtr long bent to required shape as directed and fixed to pole complete with and including two Nos. of M.S. flat 25mm x 4 mm clamps with necessary bolts, nuts and washers of suitable size complete all as specified and as directed by Engineer-in-Charge.
Taking down existing old/ undserviceable MCCBs of any description from LT panel board complete all as specified and as directed.
S&F for MCCB, 415 V, AC, 50 KA breaking capacity, 4 pole of rating 400 Amps, ices = icu=100% with adjustable thermal & fixed magnetic setting, 70-100% complete fixed with LT panel board all as specified and as directed.
S&F for MCCB, 415 V, AC, 36 KA breaking capacity, 4 pole of rating 200 Amps, with adjustable thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and as directed.
S&F for MCCB, 415 V, AC, 36 KA breaking capacity, 4 pole of rating 125 Amps, with adjustable thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and as directed.
S&F for MCCB, 415 V, AC, 36 KA breaking capacity, 4 pole of rating 100 Amps, with adjustable thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and as directed.
S&F for MCCB, 415 V, AC, 36 KA breaking capacity, 4 pole of rating 63 Amps, with adjustable thermal & fixed magnetic setting, complete fixed with LT panel board all as specified and as directed.
S&F in repair MCB, Single pole and neutral , 240 Volts, 6 to 32 Amps, 'C' series, 10KA capacity breaking capacity complete all as specified and directed,
S&F in repair for galvenised iron strip 32 x 6 mm buried in ground complete all as specified and directed,
S&F in heavy duty long life power capacitor (KVAR) of various capacity as per site requirement , 440 Volt AC complete all as specified and directed,
Supply only water proof/submersible rubber insulation tape complete all as specififed and as directed.
Supply only PVC insulation tape Box/ packet contain 9M roll 12 Nos in each Pack complete all as specified and directed.
M&L for panel reparing and spray painting only external surfaces of dimension not exceeding 1.8 mx1.4 mx0.6 m to 1.0mx0.9mx0.6 m without taking down pannel accessoriesone and apply two coat of synthetic enamel paint over a coat of red oxide primer on steel surfaces including preparation of old surfaces of steel by scrapping, rubbing complete all as specified and as directed. .
M&L for panel reparing by welding/ brazing etc making door to opening properly for any existing electrical panel complete all as specified and as directed.
S&F in repair electric panel door lock of same type as per existing one with key complete all as specified and as directed.
S&F resin type straight throught LT 11000 Volt cable joint kit of size 25- 50 Sqmm 4 Core complete all as specified and as directed. Note: Only necessary earth work shall be measured and paid separately rest are included in unit quoted rate.
S&F resin type straight throught LT 11000 Volt cable joint kit of size 75- 120 Sqmm 3.5/4 Core complete all as specified and as directed. Note: Only necessary earth work shall be measured and paid separately rest are included in unit quoted rate.
S&F resin type straight throught LT 11000 Volt cable joint kit of size 150- 185 Sqmm 3.5/4 Core complete all as specified and as directed. Note: Only necessary earth work shall be measured and paid separately rest are included in unit quoted rate.
S&F resin type straight throught LT 11000 Volt cable joint kit of size 300- 400 Sqmm 3.5/4 Core complete all as specified and as directed. Note: Only necessary earth work shall be measured and paid separately rest are included in unit quoted rate.
S&F resin type End termination LT 11000 Volt cable joint kit of size 25- 50 Sqmm 3.5/4 Core complete all as specified and as directed. Note: Only necessary earth work shall be measured and paid separately rest are included in unit quoted rate.
S&F resin type End termination LT 11000 Volt cable joint kit of size 75- 120 Sqmm 3.5/4 Core complete all as specified and as directed. Note: Only necessary earth work shall be measured and paid separately rest are included in unit quoted rate.
S&F resin type End termination LT 11000 Volt cable joint kit of size 150- 185 Sqmm 3.5/4 Core complete all as specified and as directed. Note: Only necessary earth work shall be measured and paid separately rest are included in unit quoted rate.
S&F resin type End termination LT 11000 Volt cable joint kit of size 300- 400 Sqmm 3.5/4 Corecomplete all as specified and as directed. Note: Only necessary earth work shall be measured and paid separately rest are included in unit quoted rate.
S&F indication lamp set of three of colour Red, Yellow, and Blue for LT panel Board including takinf down old one complete all as specified and as directed.
M&L for preparation of old painted surface and removing dust and other deposited material by scraping from LT PSC/steel tubular poles of upto 11.00 metre long, cross arms brackets and applying two coats of aluminium paint to all steel surfaces, including MS clamps, cable protection pipe, bracket fitted with street light fittings etc and one coat of cement based paint to PSC pole including Zebra colour of painting upto 2.1 m height from the top of coping/bottom of pole as per site condition and numbering of poles complete all as specified and as directed. Note :(a) Zebra colour will be applied by synthetic enamel paint of black/yellow colour as approved in alternate layer of 30 cm height of each layer. (b) Pole number should be wrriten on each pole with preparation date.
Supply installation, commissioning and testing including providing all necessary electrical connection, LT Junction box, outdoor type CPRI approved factory made out of 3.15 mm thick MS sheet of size 0.60mx 0.60 mx 0.50 m deep having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 Nos legs 0.5 meter length with cable entry and exit circular hole with cable gland & gasket at bottom including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1, with danger notice plate, street light panel of 1.6mm thick mild steel sheet, vitereous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc including taking down Old unserviceable box complete all as directed by the Engr-in-Charge and comprising of the following accessoriescomplete including following accessories :- (a) MCCB, 4 Pole, 200-250 Amps, 415 Volt, 36 KA I/C, with thermal and magnetic release. (b) Aluminium bus bar 4 strip of 300 Amps of size 40 x 2.5mm having hole drilled on bus bar for fixing of cable
Taking down carefully aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
M&L for point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLSH PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box (sunken type) with 3mm thick hylam sheet cover fixed with suitable sizes cadmium plated iron screws and washers etc. for mounting switches, sockets, fan regulators etc complete for one light/ fan /bell /buzzer point controlled by one, one way switches complete all as specified and as directed.
All as per item No 88 above but for one 3 pin socket outlet, 5 Amps on Independent board.
All as per item No 88 above but for one 5 Amps, 3 pin socket outlet on the same board with other switches.
All as per item No. 88 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 15/16 amp multi socket out let on independent board.
M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size passing through and including suitable PVC conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls /ceiling etc , including cutting chases, making good with cement mortar 1:3, terminated in and including providing PVC/modular metal box of suitable size with 3mm thick hylam sheet cover for fixing of switches, sockets, fan regulators etc for one light/fan/bell/buzzer point controlled by one, one way switches complete all as specified and as directed.
All as per item No 92 above but for one 3 pin socket outlet, 5 Amps on Independent board.
All as per item No 92 above but for one 5 Amps, 3 pin socket outlet on the same board with other switches.
All as per item No. 92 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 5/15 Amps switch socket combination on Independent board. One 3 pin socket outlet, 5 Amps, independent board.
S&F for switch piano, flush type single pole, 230 volts, 5 Amp one way bearing ISI marked complete all as specified and as directed.
S&F for socket outlet, 2 in 1, 3 pin, 5 Amps, 240V bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 5 in 1, 5/16 Amps, 240 volts, bearing ISI marked flush type complete all as specified and as directed.
S&F for bell push, flush type, 5 Amps 230 Volts, bearing ISI marked complete all as specified and as directed.
S&F for call bell, AC, 230 volts, single pole complete all as specified and as directed.
S&F for ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and as directed.
S&F for stepped type (five steps), electronic fan regulator, flush type (socket type) complete all as specified and as directed.
S&F 18 Watt surface and wall mounting type LED batten with polycarbonate housing & integrated complete all as specified and as directed.
S&F in repair 10 Watt Recess mounted pressure die-cast LED aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation with separate replaceable electronic driver included cutting/opening of ceiling any type & fixing arrangement for light fitting complete all as specified and as directed. Make : Cat No.INTEGRAGRANDDLR10WLED865S of or equivalent make of Appendix 'A'.
S&F 12 Watt surface mounted downlight with white powder coated polycarbonate housing and pressure die cast heat sink having high efficiency elegantly designed sleek complete all as specified and as directed.
S&F 25 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having BOTTOM OPENING separate driver compartment with IP65 protection and impact resistance of IK07 including taking down old light fittings of any type complete all as specified and as directed.
S&F 9 Watt surface and wall mounting type LED batten with polycarbonate housing & integrated complete all as specified and as directed. Make : Cat No. LUMILINEBS9WLED830SPCWH of Havells or equivalent make of Appendix 'A'.
S&F 15 Watt surface mounted down light 1x1 feet, white powder coated, PDC heat sink having high efficiency, polycarbonate housing, aestthetically designed 1x1 feet LED flat panel for surface mountingcomplete all as specified and as directed.
S&F for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F for LED Lamp 9 Watt complete all as specified and as directed.
S&F in repairs PVC rectangular block for mounting, MCB DB's etc. with 3 mm thick plastic laminated sheet cover of size 250 mm x 200 mm and 50 mm deep complete all as specified and as directed
S&F in repair PVC rectangular block for mounting, MCB DB's etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and as directed.
S&F in repair PVC rectangular block for mounting, MCB DB's etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and as directed.
Taking down unserviceable sub-main wiring up to 10 sqmm with rigid steel conduits/PVC casing-caping including cutting chases for taking out conduits and making good disturbed surfaces complete all as specified and as directed.
M&L for sub main wiring with two run of 6 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size, fixed to wall/ceiling etc including one run of 6 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
M&L for sub main wiring with two run of 4 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size, fixed to wall/ceiling etc including one run of 4 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length. (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
M&L for sub main wiring with two run of 2.5 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size, fixed to wall/ceiling etc including one run of 2.5 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length. (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
M&L in repairs sub main wiring with four run of 10 sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC conduit of suitable size, surface/concealed etc including provision of 2x6 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) Extra length of cables/wire required for connectionto MCBs/DBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly. (b) For concealed wiring cutting chases, chipping and plastering shall be measured and paid separately under relevant items.
M&L in repairs sub main wiring with four run of 6 sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC conduit of suitable size, surface/concealed etc including provision of 2x4 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) Extra length of cables/wire required for connectionto MCBs/DBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly. (b) For concealed wiring cutting chases, chipping and plastering shall be measured and paid separately under relevant items.
S&F in repairs switch piano, flush type, 5 Amps, single pole, one way, bearing ISI marked 240 Volts complete all as specified and as directed.
S&F in repair socket outlet, 2 in 1, 3 pin , 5 Amps, flush type bearing ISI marked complete all as specified and as directed.
S&F in repair switch socket combination 2 in 1, 5 pin, 5 Amps, flush type, bearing ISI marked 240 volts complete all as specified and as directed.
S&F in repair switch socket combination 2 in 1, 6 pin, 5/16 Amps, flush type, bearing ISI marked 240 volts complete all as specified and as directed.
S&F in repairs bell push, flush type, 5 Amps 230 Volts bearing ISI marked complete all as specified and as directed.
S&F in repairs call bell , AC 230 Volts, single pole all as specified and as directed.
S&F in repairs ceiling rose, 3 phase, PVC polycarbonate, isolated body (with PVC box) bearing ISI marked complete all as specified and as directed.
S&F in repair Stepped type(five steps), electronic fan regulator, 220 volts, flush type complete all as specified and as directed.
S&F in repair modular switch 1 way 6 A, 1 Module in existing location complete all as specified and as directed.
S&F in repair modular switch 1 way 16 A, 1 Module in existing location complete all as specified and as directed.
S&F in repair modular socket 6-A, 2/3 Pin combined 2 module in existing location, complete all as specified and as directed.
S&F in repair modular socket 6 A/16 A, 2/3 Pin combined 2 module in existing location, complete all as specified and as directed.
S&F in repair modular fan regulator step Type 120 Watt, 2 Module in existing location complete all as specified and as directed.
S&F in repairs LED wall bracket light asthetically designed with B22d & E27 lamp holder made up of polycarbonate, suitable for 9/10 including suitable LED bulb complete with all accessories including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to light fittings and taking down old light fittings of any type complete all as specified and dierected. Make :Cat No HLWB-01-B22 of Halonix/ or equivalent make of Appendix 'A'.
S&F in repair 10 Watt Recess mounted pressure die-cast LED aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation with separate replaceable electronic driver included cutting/opening of ceiling any type & fixing arrangement for light fitting complete all as specified and as directed. Make : Cat No.INTEGRAGRANDDLR10WLED865S of or equivalent make of Appendix 'A'.
S&F 18 Watt surface and wall mounting type LED batten with white acrylic cover sleek design & high efficiency complete all as specified and as directed. Make : Cat No. BCLSB 18 W WH of Bajaj or equivalent make of Appendix 'A'.
S&F in repairs 9 Watt surface and wall mounting type LED batten with polycarbonate housing & integrated complete all as specified and as directed.
S&F in repairs 25 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having BOTTOM OPENING separate driver compartment with IP65 protection and impact resistance of IK07 including taking down old light fittings of any type complete all as specified and as directed.
S&F in repairs 12 Watt LED surface mounted down light with white powder coated polycarbonate housing and pressure die cast heat sink having high efficiency round including taking down unserviceable light fitting complete all as specified and as directed. Make : Cat. No. EDGESURFACERDDLR12WLED840S of Havells or equivalent make of Appendix 'A'.
S&F in repairs recess mounted deep drawn PLANO size (2 ft x 2 ft) CRCA housing with higher power 42 Watt LED Seamless front frame with flat white hight transmission acrylic cover complete all as specified and as directed.
S&F in repairs recess mounted deep drawn PLANO size (1 ft x 4 ft) CRCA housing with higher power 32 Watt LED Seamless front frame with flat white hight transmission acrylic cover complete all as specified and as directed.
S&F in repairs recess mounted deep drawn PLUTO size (1 ft x 1 ft) CRCA housing with higher power 15 Watt LED Seamless front frame with flat white hight transmission acrylic cover complete all as specified and as directed. Make : Cat. No.PLUTO 1x1 PLR 15 W LED 840S of Havells/Philips/Bajaj.
S&F in repair lamp holder, PVC/Polycarbonate type insulated body with back plate in existing location suitable for batten fittings complete all as specified and as directed.
S&F in repair 3 mm thick, PVC hylem sheet top cover of size 250 mm x 200 mm x 3 mm complete all as specified and as directed.
S&F in repair 3 mm thick, PVC hylem sheet top cover of size 175 x 100 x 3 mm complete all as specified and as directed.
S&F in repair 3 mm thick, PVC hylem sheet top cover of size 100 x 100 x 3 mm complete all as specified and as directed.
S&F for sheet metal enclosure TPN board distribution (DB) having facility to fix MCCB in incomer and MCBs in outgoing, TPN 4 ways, IP-43 with metal door type complete fitted with bus bars , neutral links, blanking plates including making dgood disturb surface, including taking down old unserviceble MCB DB complete all as specified and as directed. Make: Legrand, Cat Pt No. 607913 or equivalent make of Appendix 'A'.
S&F in repair MCCB of four pole type, 160 Amps current capacity, thermal magnetic, type, 36 KA breaking capacity, 415 Volts complete all as specified and as directed.
S&F in repair factory made board distribution (DB) double door in sheet metal enclosure with common bus bar at incomming end bus bar, triple pole & neutral (TPN), 4 way, 415 Volts suitable for fixing MCBs including complete all as specified and as directed.
S&F in repair factory made board distribution (DB) double door in sheet metal enclosure with common bus bar at incomming end, single pole & neutral, 8 way, 240 Volts suitable for housing MCBs including complete all as specified and as directed.
S&F in repair factory made board distribution (DB) double door in sheet metal enclosure with common bus bar at incomming end, single pole & neutral, 4 way, 240 Volts suitable for housing MCBs including complete all as specified and as directed.
S&F in repair MCB, four pole, 415 Volts, 63 Amps, breaking capacity 10 KA complete all as specified and as directed. Make : Cat. No. 408702 of Legrand equivalent make of Appendix 'A'.
S&F in repair MCB, double pole, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed.
S&F in repair MCB, 'C' Series, SP, 240 Volts, 40- 63 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : Cat. No. 408596 to 408598 of Legrand equivalent make of Appendix 'A'.
S&F in repair sheet metal enclosure for MCB DB single door, single pole & neutral, two way, 240 V with common bus bar at incoming end complete all as specified and as directed.
S&F in repair, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps rating complete all as specified and as directed.
S&F in repair, LED step/foot light in white powder coated cast aluminium body & IP 54 protection complete all as specified and as directed.
S&F in repair, 7 Watt LED (muzris) wall mounting fitting with flexible neck for adjusting beam, bronze finish (warm white ) complete all as specified and as directed. Make :Philips, Cat pat No.: 31402 or equivalent make of Appendix 'A'.
S&F in repair, LED 2x 3.5 die cast aluminium housing , opal PC diffuser, IP54 protection, up down light (Xquizit) complete all as specified and as directed.
gitu gohain (BID ID -3052798)
NChetia and Sons Trading (BID ID -3056137)
R D Enterprises (BID ID -3057061)
M/S KAUSHIK ENTERPRISE (BID ID -3054651)
M/s Kanchan Enterprise (BID ID -3055635)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .