Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAdmitted-Finance 25 140 OM DULARI SHAKTI NAGAR DELHI DELHI 110007 | NORTH DELHI | DELHI | 110007 | L1 | Admitted-Finance | |
| 2 | L2₹7.5 L+₹6.4 L (575.9%)Admitted-Finance FLAT NO 202 2ND FLOOR 4327 3 ANSARI ROAD DARYA GANJ NEW DELHI DELHI 110002 | CENTRAL DELHI | DELHI | 110002 | L2 | Admitted-Finance | |
| 3 | L3₹10.2 L+₹9.1 L (815.9%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹15.4 L+₹14.3 L (1280.8%)Admitted-Finance 315 LAXMI DEEP DISTRICT CENTRE LAXMI NAGAR EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | L4 | Admitted-Finance | |
| 5 | L5₹17.2 L+₹16.1 L (1440.1%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | steranco health care pvt.ltd L8 | VISIONARY MEDTECH SOLUTIONS PVT LTD L6 | India Medtronic Private Limited L11 | ARIAN HEALTHCARE L2 | MEDISERVE L3 | B L Lifesciences Pvt. Ltd L10 | GENESEE MEDICALS L9 | Unicore Medical Systems Pvt Ltd L4 | DIVINE HEALTHCARE L5 | J. Mitra & Bros. L7 | Vijay Surgical Corporation L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Purchase of Surgical Disposable Items on Two Years Rate Contract Basis for CTVS | ||||||||||||||
| 1.01 | VSD Ring Adult & Child
• Should be available in adult size: (35cm outer ring and 20cm inner ring with the circular opening of size 10cm) and pediatric size: (30cmx20cmx10cm)
• Should be made of medical grade cotton cloth (high quality Linen)
• Cloth should be preferably white coloured so that suture can be clearly traced
• Should be ETO Sterilized
• There should be high quality stitching of margin of cloths (doubly stitched without any loose hanging threads)
• Should provide samples for final physical verification and approval | 1,600 | pices | - | - | - | - | - | - | - | - | 2,72,000 ₹2,85,600 Lowest | - | - |
| 2.00 | Surgical Clipper Blade
• Should enable high efficiency surgical hair removal in minimum passes and minimum trauma to skin
• Should have ergonomic design to handle curved areas on the body
• Should be sterlisable (ETO Or Cidex Solutions) the assembly should be robust to handle submersion in disinfectant solutions.
• Energy Source - Should be rechargeable or should come with slots for easily available batteries.
• Clipper should be compatible with all standard Surgical clipper blade or should supply blades.
Should provide samples for final physical verification and approval | 8,000 | pices | - | - | - | - | - | - | - | - | - | - | - |
| 3.00 | Bovine Pericardial Patch-All sizes
• It should flexible for ease of suturing
• It should be easy to handle
• Should be ready to use fact with minimum rinse time
• Patch thickness range 0.4-0.6 mm
• Should have construction such that it aligns well to various heart counours
• Should be hemostatic to minimize perioperative patch-related bleeding | 200 | pices | - | 29,60,000 ₹33,15,200 | - | - | - | - | - | - | - | 28,00,000 ₹31,36,000 Lowest | - |
| 4.00 | Cell Saver Kit
• Should be one-stop complete kit of disposables for collection, washing, filtering, processing and storage of blood collected from patient
• Should be compatible with current available hardware (Cell saver system) in CTVS department (bidding vendor may inspect the machine before quoting)
• The disposable kit should include suction-anticoagulant line, waste saline collection bag, filter cone, blood collection bag, connectors and prime ports. | 800 | pices | 63,16,800 ₹70,74,816 | - | 60,00,000 ₹67,20,000 Lowest | - | - | - | 70,40,000 ₹78,84,800 | - | - | - | - |
| 5.00 | Internal mammary artery needle (Arteriotomy Cannula)
• The lumen should be of 1 mm or less only.
• The length should be of in the range of 1.5-2.5 inches.
• The Shaft should be made of medical grade stainless steel.
• The tip of cannula should be bulbous and atraumatic.
• The cannula should end with female leur fitting: which can be attached to any regular 5ml or 10ml syringe.
• Should provide sample for final physical verification and approval.
• Electro surgical Ground Pad. | 200 | pices | - | - | - | - | - | - | - | - | - | - | - |
| 6.00 | Soft PD Catheter Adult
Complete kit should be available with one set.
• Kit should have Soft PD catheter, clamp, adapter, guidewire, syringe, introducer needle, tunneling stylet, surgical blade.
• Two cuffs should be available in the PD catheter (Preperitoneal and subcutaneous)
• The Catheter material should be soft and non-irritant for prolonged placement in peritoneal cavity without causing adhesions or erosions.
• Adult catheter total length: 40-60cms.
• Should have a radio opaque stripe on one side. | 200 | pices | - | - | - | - | - | - | - | - | - | - | - |
| 7.00 | Soft PD Catheter ,Pediatric
• Complete kit should be available with one set.
• Kit should have Soft PD catheter, clamp, adapter, guidewire, syringe, introducer needle, tunneling stylet, surgical blade.
• Two cuffs should be available in the PD catheter (Preperitoneal and subcutaneous)
• The Catheter material should be soft and non-irritant for prolonged placement in peritoneal cavity without causing adhesions or erosions.
• Adult catheter total length: 40-60cms.
• Pediatric catheter total length: 20-40cms.
• Should have a radio opaque stripe on one side. | 400 | pices | - | - | - | - | - | - | - | - | - | - | - |
| 8.00 | Soft PD Catheter ,Neonatal
• Complete kit should be available with one set.
• Kit should have Soft PD catheter, clamp, adapter, guidewire, syringe, introducer needle, tunneling stylet, surgical blade.
• Two cuffs should be available in the PD catheter (Preperitoneal and subcutaneous)
• The Catheter material should be soft and non-irritant for prolonged placement in peritoneal cavity without causing adhesions or erosions.
• Should have a radio opaque stripe on one side. | 100 | pices | - | - | - | - | - | - | - | - | - | - | - |
| 9.00 | Haemodialysis Kit for Adult (supplied as one pack)
• Should have double lumen Catheter 11.5 Fr.
• Polysulfone dialyzer.
• AV tubing.
• Haemodialysis fluid 5L.
• Bicarbonate powder as required for dialysis for one adult. | 40 | pices | - | - | - | - | - | - | - | - | - | - | - |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
3 Dec 2019, 3:00 pmClosed
Store Officer (CNC), AIIMS
Store Officer (CNC), Store Section (CNC), N.P Ward, AIIMS 110029
As per Tender Document
2019_AIMSD_516802_1
87/CNC/CTVS/2019-20/ST.
Open Tender
Medical Equipments/Waste
Buy
180 days
CNC AIIMS, NEW DELHI
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹1 L
Yes
Seminar Room 7th Floor Cardio Conference Room
28 Sept 2020
6 Nov 2019
4 Dec 2019
6 Nov 2019
3 Dec 2019
6 Nov 2019
6 Nov 2019 - 25 Nov 2019
18 Nov 2019
Purchase of Surgical Disposable Items on Two Years Rate Contract Basis for CTVS
VSD Ring Adult & Child • Should be available in adult size: (35cm outer ring and 20cm inner ring with the circular opening of size 10cm) and pediatric size: (30cmx20cmx10cm) • Should be made of medical grade cotton cloth (high quality Linen) • Cloth should be preferably white coloured so that suture can be clearly traced • Should be ETO Sterilized • There should be high quality stitching of margin of cloths (doubly stitched without any loose hanging threads) • Should provide samples for final physical verification and approval
Surgical Clipper Blade • Should enable high efficiency surgical hair removal in minimum passes and minimum trauma to skin • Should have ergonomic design to handle curved areas on the body • Should be sterlisable (ETO Or Cidex Solutions) the assembly should be robust to handle submersion in disinfectant solutions. • Energy Source - Should be rechargeable or should come with slots for easily available batteries. • Clipper should be compatible with all standard Surgical clipper blade or should supply blades. Should provide samples for final physical verification and approval
Bovine Pericardial Patch-All sizes • It should flexible for ease of suturing • It should be easy to handle • Should be ready to use fact with minimum rinse time • Patch thickness range 0.4-0.6 mm • Should have construction such that it aligns well to various heart counours • Should be hemostatic to minimize perioperative patch-related bleeding
Cell Saver Kit • Should be one-stop complete kit of disposables for collection, washing, filtering, processing and storage of blood collected from patient • Should be compatible with current available hardware (Cell saver system) in CTVS department (bidding vendor may inspect the machine before quoting) • The disposable kit should include suction-anticoagulant line, waste saline collection bag, filter cone, blood collection bag, connectors and prime ports.
Internal mammary artery needle (Arteriotomy Cannula) • The lumen should be of 1 mm or less only. • The length should be of in the range of 1.5-2.5 inches. • The Shaft should be made of medical grade stainless steel. • The tip of cannula should be bulbous and atraumatic. • The cannula should end with female leur fitting: which can be attached to any regular 5ml or 10ml syringe. • Should provide sample for final physical verification and approval. • Electro surgical Ground Pad.
Soft PD Catheter Adult Complete kit should be available with one set. • Kit should have Soft PD catheter, clamp, adapter, guidewire, syringe, introducer needle, tunneling stylet, surgical blade. • Two cuffs should be available in the PD catheter (Preperitoneal and subcutaneous) • The Catheter material should be soft and non-irritant for prolonged placement in peritoneal cavity without causing adhesions or erosions. • Adult catheter total length: 40-60cms. • Should have a radio opaque stripe on one side.
Soft PD Catheter ,Pediatric • Complete kit should be available with one set. • Kit should have Soft PD catheter, clamp, adapter, guidewire, syringe, introducer needle, tunneling stylet, surgical blade. • Two cuffs should be available in the PD catheter (Preperitoneal and subcutaneous) • The Catheter material should be soft and non-irritant for prolonged placement in peritoneal cavity without causing adhesions or erosions. • Adult catheter total length: 40-60cms. • Pediatric catheter total length: 20-40cms. • Should have a radio opaque stripe on one side.
Soft PD Catheter ,Neonatal • Complete kit should be available with one set. • Kit should have Soft PD catheter, clamp, adapter, guidewire, syringe, introducer needle, tunneling stylet, surgical blade. • Two cuffs should be available in the PD catheter (Preperitoneal and subcutaneous) • The Catheter material should be soft and non-irritant for prolonged placement in peritoneal cavity without causing adhesions or erosions. • Should have a radio opaque stripe on one side.
Haemodialysis Kit for Adult (supplied as one pack) • Should have double lumen Catheter 11.5 Fr. • Polysulfone dialyzer. • AV tubing. • Haemodialysis fluid 5L. • Bicarbonate powder as required for dialysis for one adult.
Urometer 250 ml • Should be made of high quality medical grade material, packaged in a sterile pouch. • Should have clear and transparent graduated volume meter for pediatric patients for hourly accurate measurement of the urine output. • Should be connected to a urobag having capacity of minimum 1 litre. • Should have underside drainage port for sampling and drainage. • Should be closed circuit drainage to eliminate infection risk. • Should have soft, kink resistant tubing. • Should have a universal tapered connector for secure connection with the uretheral catheter. • Should have a foldable hook and tube holder for bed side hanging.
Urometer 500 ml • Should be made of high quality medical grade material, packaged in a sterile pouch. • Should have clear and transparent graduated volume meter for adult patients for hourly accurate measurement of the urine output. • Should be connected to a urobag having capacity of minimum 1.5 litre. • Should have underside drainage port for sampling and drainage. • Should be closed circuit drainage to eliminate infection risk. • Should have soft, kink resistant tubing. • Should have a universal tapered connector for secure connection with the uretheral catheter. • Should have foldable hook and tube holder for bed side hanging.
Custom Tubing Pack for cardiopulmonary By pass-Adult without arterial filter • Should be local FDA – Drug License for Manufacturing. • Should be supplied Sterile and non-pyrogenic. • Should be ISO 9001:2008, ISO 1348: 2003 certified manufacturer. • Tubing material should be Imported USP Class VI Implant Tested Transparent PVC. • Tubing hardness should be 68 +/- Shore A. • Port material should be polycarbonate.
Invasive Arterial Catheter for BP Monitoring (22G Length: 7 to 8 cm) • Should be made of high quality medical grade, non-irratant material for long dwelling placement. • Should have complete kit arrangement for sterile placement by Seldinger technique. • Should have a stainless steel introducer and soft guidewire. • Should have Luer lock-fitting mechanism. • Should have a radio opaque line.
Invasive Arterial Catheter for BP Monitoring (20G Length: 8 to 10 cm) • Should be made of high quality medical grade, non-irratant material for long dwelling placement. • Should have complete kit arrangement for sterile placement by Seldinger technique. • Should have a stainless steel introducer and soft guidewire. • Should have Luer lock-fitting mechanism. • Should have a radio opaque line.
Invasive Arterial Catheter for BP Monitoring (18G & 16G Length: 10-15 cm) • Should be made of high quality medical grade, non-irratant material for long dwelling placement. • Should have complete kit arrangement for sterile placement by Seldinger technique. • Should have a stainless steel introducer and soft guidewire. • Should have Luer lock-fitting mechanism. • Should have a radio opaque line.
Reusable Electrosurgical Grounding pad • Should be made of Akton Foam. • Should feature Current limiting nature & hence completely eliminate Patient pad site burns. • Should be based on Capacitive coupling principle. • The pad should be such that it should not come in direct contact with patients but still safely exit current back to the generator. • Should be Radiolucent & latex free. • Reusable upto Two years. • The manufacturer should provide written guarantee that no patient pad site burns will occur within the expiry date on the pad. • Should be US FDA approved. • Should be made compatible to any Electrosurgical generator. • Size: Adult: 46”L x 20”W x ½’ thickness Paed: 26” L x 12’ W x ½” thickness Universal size: 36”L x 20”W x 1/8”thickness
Pediatric Tracheostomy Tube without Cuff (3mm to 5mm) • Should be made of high quality grade material to minimize skin irritation over long placement duration. • Material should be soft to adjust to individual patient anatomy and minimize trauma during insertion/removal. • Should have soft, flexible transparent flanges for easy fixation and underlying skin visibility. • Should have standard connector for attachment to T piece/ventilator breathing system. • Should have radio opaque line. • Kit should have non irritant neck tape for fixation.
Pediatric Tracheostomy Tube with Cuff (3mm to 5mm) • Should be made of high quality grade material to minimize skin irritation over long placement duration. • Material should be soft to adjust to individual patient anatomy and minimize trauma during insertion/removal. • Should have soft seal cuff to minimize air leak and prevent tracheal injury. • Should have soft, flexible transparent flanges for easy fixation and underlying skin visibility. • Should have standard connector for attachment to T piece/ventilator breathing system. • Should have radio opaque line. • Kit should have non irritant neck tape for fixation.
Liquid Nitrogen Gas - • Supplier should ensure high purity medical grade Liquid Nitrogen stored in safe and standard containers. • The containers should ensure maximum coolant retention. • Nitrogen pressure at 21 degrees Celsius should be in the range of 1900-2300 PSI. • Should be available in standard cylinder size which can be easily emptied into Nitrogen storage tanks in our valve bank facility. Supplier should ensure fast (within 48 hours) and consistent supply of Nitrogen cylinders on a requirement notice from the department
CAROTID ARTERY LOOP SHUNT ALL SIZES: • Should be packaged in sterile easy peel – off wrapper (double wrap, Pyrogen free packing). • Should be available in various adult sizes. • Should be constructed of high quality silicon with metallic wiring to prevent kinking or occlusion. • The ends of shunt should be bulbous for easy placement and retention in carotid vessel. • Should be available in small, medium and large diameter sizes. • Length 10-30cm.
AXILLARY ARTERY ONE PIECE CANNULA WITH CENTRAL ARTERIAL PRESSURE MEASUREMENT • Sizes 18 Fr. - 24Fr. • Should have elongated one piece wire wound body with radio opaque suture ring and dilator with depth markings. • Should have integrated pressure monitoring port at tip.
DISTAL ARTERIAL PERFUSION CANNULA • Should be made of high grade natural rubber latex/ equivalent. • Diameter ranges 11-14 Fr. • Should have a distal easily inflatable latex balloon. • Color Coding of two stop cock (balloon inflation and blood flow control) should be there. • Should be packaged in sterile non pyrogenic, easy peel – off packing.
AORTIC ARCH PERFUSION CANNULA • Should be long and flexible. • Should have wire reinforcement. • Should have an obturator for easy distalmost arch cannulation .
Aortic Perfusion Cannula Sizes: 10,12,14,16,18,21,24,26 FR/CH • Should have smooth bevelled tip. • Should be long and flexible. • Cannula Should be clear for good visibility • Should have an indicator coloured line for proper placement
BALLOON TIP ANTEGRADE CEREBRAL PERFUSION CANNULA • Should be highly flexible but kink resistant. • Should have a soft latex inflatable balloon near tip to ensure unidirectional blood flow and prevent displacement/blood leaks. • Should be available in a range of sizes 8 French-14 French
TEFLON HARD FELT: • Should be made of high quality fabric to ensure accurate homeostasis. • Thickness 2-3 mm to provide adequate strength to tissue. • SIZES:- 4”X4” & 6”X6”
E-PTFE Stretch Large Diameter Aortic Vascular Graft of Diameter and length as under. a. 20mm x 28 cm
E-PTFE Stretch Large Diameter Aortic Vascular Graft of Diameter and length as under. b. 20mm x 30 cm
E-PTFE Stretch Large Diameter Aortic Vascular Graft of Diameter and length as under. c. 24mm x 20 cm
E-PTFE Stretch Large Diameter Aortic Vascular Graft of Diameter and length as under. d. 22mm x 20 cm
E-PTFE Stretch Large Diameter Aortic Vascular Graft of Diameter and length as under. e. 22mm x 30 cm
E-PTFE Stretch Large Diameter Aortic Vascular Graft of Diameter and length as under. f. 24mm x 30 cm
SNUGGER SET – All sizes: • Three pairs of smooth Snugger with Yellow, Blue & Pink colors for vessel identification. • Each snare set consists of thumb holder handle for easy maneurability. • Specially designed for putting purse string sutures, • made of medical grade PVC. • Sizes Adult & Pediatric.
Suprapubic Catheter with Trocar • Used for cystostomy and supra-pubic drainage. • Manufactured from 100% silicone, non-toxic and non-irritant. • Symmetrical inflated balloon provided for self retention. • Radio-opaque line throughout its length for x-ray visualization. • One lateral eye at distal end for efficient drainage. • Sterile, individually packed in box. • Sizes: 16, 18, 20, 22 FG
Gravity Bag • 1200 ml capacity bag for feeding purpose. • Ice pouch provided with the bag for preserving the food for longer period. • Transfer set directly connected to the bag for easy feeding. • Roller controller is provided to control the flow. A hanger is provided with bag for easy handling. • Sterile, individually packed in peelable pouch.
Centrifugal Pump disposable cone – Adult • Should be compatible (without adapter) with the existing Medtronic/ Sarns/ Terumo pump machine available in the department. Budding vendor may inspect the machine before quoting. • Should work within a low prime volume (40-80 ml). • Should hav 3/8 inch inlet outlet. • Flow range 0.1 – 9 litre/min. • Rotation range 0-3600rpm. • Low heat generation created by fewer moving parts and ceramic pivot bearing. • Should have biocompatible internal surfaces causing low hemolysis. • Interested bidder is required to make a demonstration before bidding.
Centrifugal pump disposable cone Pediatric • Should be compatible (without adapter) with the existing Medtronic/ Sarns/ Terumo pump machine available in the department. Bidding vendor may inspect the machine before quoting. • Should work within a low prime volume (40-80 ml) • Should have 1/4th inch inlet outlet • Flow range 0.1 – 6 litre/min • Rotation range 0-3600 rpm • Low heat generation created by fewer moving parts and ceramic pivot bearing. • Low impact with even blood flow, low shear and no stagnant blood zones • Should have biocompatible internal surfaces causing low hemolysis Interested bidder is required to make a demonstration
Helium Gas for Refill Cylinder (IABP) : of 900 ml each 1. Refilling gas is to be done for cylinders fitting with existing Maquet IABP Machine. 2. Cylinders to be filled with compressed Helium . 3. Minimum recommended Helium Grated for filling should be U.S.P. 99.0%(UN1046) 4. When filled Content should be 90-9 standard liters@ 2200-2500 PSIG(200 Barr) at 70 degree F 5. Volume should be 680-700 cc 6. The firm should ensure that refilling of an empty cylinder is completed (and cylinder supplied back to user department) within 4-5 days.
Biological indicator for steam Autoclave 1. Should inadequate biological adequacy of STEAM AUTOCLAVE sterilization process ( by negative or positive culture ), sterilization procedure will be done in OT autoclave at 120-132 * Celsius. 2. The Indicator should be in a glass cartridge / test strip form. 3. The indicator should have adequate concentration of biological indicator spores (Geobacillus stearothermophilus and / or Bacillus atropheaus). 4. The indicator cartridge / strip, after sterilization process, should be easily transferable to the microbiology laboratory and transfer to culture medium from the strip / cartridge should be possible, in an aseptic manner. 5. The container box and each individual strip/ cartridge should have a label with expiry date on it.
ARIAN HEALTHCARE
MEDISERVE
Unicore Medical Systems Pvt Ltd
DIVINE HEALTHCARE
VISIONARY MEDTECH SOLUTIONS PVT LTD
J. Mitra & Bros.
steranco health care pvt.ltd
GENESEE MEDICALS
B L Lifesciences Pvt. Ltd
India Medtronic Private Limited
J. Mitra & Bros.
DIVINE HEALTHCARE
Unicore Medical Systems Pvt Ltd
B L Lifesciences Pvt. Ltd
Vijay Surgical Corporation
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .