Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L2₹14.2 L+₹1.6 L (12.6%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest. | |
| 3 | L3₹14.3 L+₹1.7 L (13.6%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest. |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF SRINAGAR
CWE AF SRINAGAR
REPAIR MAINT OF SPLIT AC WINDOW TYPE AC DEEP FREEZER AND REFRIGERATOR AT 8 FBSU AF STN AWANTIPUR
2023_MES_606366_1
CWE(AF)SGR/AWA-14/2023-24
Open Tender
Civil Works
Item Rate
180 days
AF STN AWANTIPUR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF AWANTIPUR
₹40,000
Yes
5 Jan 2024
28 Jun 2023
1 Sept 2023
28 Jun 2023
30 Aug 2023
16 Aug 2023
Amount
Servicing/maintenance of Split type Air conditioner of 1 to 2 ton cap any make any size by taking down the AC , which includes the following :- (i) Taking out the entire unit from the existing location wherever installed after unscrewing front cover, packing material, ply or any type of front cover whatever it may be. (ii) Servicing/cleaning the entire unit with elect blower and cleaning with Collin or equivalent agent. (iii) Testing the AC and replacement of defective spare part and refixing complete all as directed Note :- (i) Spare parts/ wall bracket stand for split AC if any reqd shall be measured and paid separately as S&F . (ii) Labour element for fixing of any defective spare part shall be part of the item excluding major parts like compressor, gas charging, leak testing etc. (iii) Thorough care / protection of PCB plate shall be taken to avoid any kind of damage while servicing/ cleaning or otherwise same will be repaired/replaced by contractor at his own cost. (iv) Sealing of unit with thermocol/ packing material shall be part of the job at no extra cost . (v) Each service shall be measured and paid separetly as each job.
Material and labour for WATER JET Washing/thorough cleaning of condensing and cooling coil SPLIT TYPE AC/Window AC of 1.5/2.0 tone capacity (complete indoor and outdoor unit by using service bag cover & cooling coil rinse solution for cleaning of coils), taking out the indoor top cover outdoor top cover from existing location, all as directed by the Engineer-in-Charge. (Note: The contractor shall at his own cost arrange water for servicing purpose)
All as per srl item No. 2.00 here-in-above but for WINDOW TYPE AC's of 1.5/2.0 tone capacity.
Material and labour in replacement fire resistance, elastomeric Nitrile rubber tubing (NBR) for Pipe insulation thickness 10mm of size ⅝"dia of split type AC's any capacity all as specified and directed. MAKE : SUPREME INSUFLEX / AEROFOAM /SUPERLON
All as per srl item No. 4.00 here-in-aboveabove but size ¼” .
Material and labour for disconnecting all the electric connection of window AC and taking down the AC from its location safely. Making proper rectengular hole in the wall by cutting the wall surface as per dimentions of Window AC , Supply & fixing of wooden frame for window AC as per dimentions of window AC, do proper masonary work if needed after fixing of wooden frame make surface clean and fix the AC in the wooden frame properly complete all as specified and as directed. (Note: wooden frame and masonary work included in the rate quoted by the contractor for this schedule item )
Material and labour for rectification of Gas leakage (if any) and brazing the leaked part if detected to completely block the leakage of window/split type AC 1.5 TR/2 TR including charging of gas (rate for gas will be paid separately), Greasing lubrication of rotary parts and making serviceable complete with testing etc complete all as specified and directed.
Supply and fixing of front show grill for window type AC of capacity 1.5/2.0 Ton as per existing make and model complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of thermostat for window type AC of capacity 1.5/2 Ton. Complete all as specified and directed by Engineer-in-Charge . (Make : -Indfos/Renutrol)
Supply and fixing of air sweep louvers with motor complete set in replacement suitable for window type ACs of capacity 1.5/2.0 TR complete all as specified and directed.
Supply and fixing of blower fan motor suitable for cooling unit of Window type Acs/cooling unit (Indoor unit) of Split AC of capacity 1.5/2.0 TR complete all as specified and directed. (Make-AUE/Cromption Greaves/Cool Master)
Removing the burnt blower motor window AC/Split AC of capacity 1.5 /2 TR rewinding with supper enameled copper winding wire with same gauge and superior quality with same gauge and insulation material such as varnish, cotton tape, including gun metal bush bearing shaft and refixing of original position complete with testing etc complete all as specified and directed.
Supply and fixing of Condensing Fan Motor as per Existing Make and Capacity For 1.5/2 Ton Window/Split Type AC Complete all as specified and directed by Engineer-in-Charge. (Make : -AUE/Crompton Greaves/Cool Master)
Supply and fixing condensing coil as per existing make for 1.5/2.0 Ton for window AC capacity as directed by Engineer-in-Charge. (Make-Voltas/Hitachi/LG)
Supply and fixing of condensing coil as per existing make for 1.5/2.0 Ton capacity split AC as directed by Engineer-in-Charge. (Make-Voltas/Hitachi/LG)
Supply and fixing Printed Circuit Board for window type AC operating at hot and cold mode of capacity 2.0Tno/1.5 Ton , compete all as specified and as directed. Make: LG/ Voltas/ Bluestar/Hitachi
Supply and fixing Printed Circuit Board for split type AC operating at hot and cold mode of capacity 1.5/2 Ton, compete all as specified and as directed. Make: LG/ Voltas/ Bluestar/Hitachi
Supply and fixing Printed Circuit Board for indoor unit of inverter type split type AC operating at hot and cold mode of capacity 1.5/2 Ton, compete all as specified and as directed. Make: LG/ Voltas/ Bluestar/Hitachi
Supply and fixing Printed Circuit Board for outdoor unit of inverter type split type AC operating at hot and cold mode of capacity 1.5/2 Ton, compete all as specified and directed. Make: LG/ Voltas/ Bluestar/Hitachi
Supply and fixing drain pipe PVC of size 15 mm 3 m long, complete all as specified and as directed.
Supply and fixing of reverse valve in Split type AC to make it functional for heating also all as specified and directed.
Supply and fixing of capacitor as per existing make and capacity 45/4 MFD for compressor of split/window type AC capacity 1.5/2.0 Ton. Complete all as specified and directed by Engineer-in-Charge. (Make : -Epcos/Usha/Keltron)
Supply and fixing of capacitor as per existing make and capacity 50/36 MFD for compressor of split/window type AC capacity 1.5/2.0 Ton. Complete all as specified and directed by Engineer-in-Charge. (Make : -Epcos/Usha/Keltron)
Supply and fixing starting capacitor of 6 MFD in replacement suitable for blower motor of split type ACs of capacity 2.0 TR complete all as specified and directed. (Make : -Epcos/Usha/Keltron)
Supply and fixing of starting capacitor as per existing make and capacity 100 to 120 MFD for compressor of window/split type AC capacity 1.5/2.0 Ton. complete all as specified and directed by Engineer-in-Charge. (Make : - Epcos/ Usha/ Keltron)
Supply and fixing of condenser unit split type AC 1.5/2.0 Ton L& key valve 5/8" size with proper leak check all as directed by Engg -in charge.
All as per srl item No. 26.00 here-in-above but 1/4" size.
Supply and fixing flair nut for connecting copper pipe of indoor and outdoor unit of size 5/8" and 1/2"dia for any capacity of split type AC all as specified.
All as per item No 28.00 above but size 3/8" and 1/4" .
Material and labour for descaling the entire Condensing coil/ condenser of split/window ac of capacity 1.5/2 TR by descaling solution circulating solution of standard value with the help of descaling pump cleaning the condenser tubing with brush attached with rod including taking down the unit from installation and refix to the same location complete all as specified.
Material and labour for descaling the entire Evapourating coil/ Evapouratpr for split/window ac of capacity 1.5/2 TR by descaling solution circulating solution of standard value with the help of descaling pump cleaning the Evapourator tubing with brush attached with rod including taking down the unit from installation and refix to the same location complete all as specified and directed.
Supply and fixing of in replacement U/S compressor with new compressor capacity 2.0 Ton for window AC as per existing make as directed by Engineer-in-Charge. Note : - Transportation charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above. Make: LG/ Voltas/ Bluestar/Hitachi
Supply and fixing in replacement U/S compressor with new compressor capacity 1.5 Ton for split AC including taking down of the old compressor complete with brazing work making the connection leak proof as per existing make as directed by Engineer-in-Charge. Note : - Transportation charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above. Make: LG/ Voltas/ Bluestar/Hitachi
All as per item No. 33 above but for 2.0 Ton capacity.
Supply and fixing in replacement U/S compressor with new compressor capacity 1.5 Ton/2.0 Ton for invertor type of split AC including taking down of the old compressor complete with brazing work making the connection leak proof as per existing make as directed by Engineer-in-Charge. Note : - Transportation charges from site to trade workshop and back to original location after repair shall be deemed to be included in unit rate quoted above. Make: LG/ Voltas/ Bluestar/Hitachi
Supply and charging of gas R-22 for window AC/ Split AC Complete all as specified and directed by Engineer-in-Charge
Supplying and charging (Top up) refrigerant compressor/ AC/ Fridge/ Deep Freezer with refrigant gas R-407C/410A in required quantity for desired cooling complete all as specified and directed.
Supply and charging (Top up) refrigerant compressor/AC/Fridge/Deep Freezer with refrigerant gas R32 in required quantity for desired cooling complete all as specified and directed.
Supply and fixing air filter made of Ric/ nylon suitable for window/split type Air Conditioner 1.5 TR/ 2TR capacity complete all as specified and directed. Make: AC Samsung/ LG/ Voltas/ Carrier
Supply and fixing in replacement of Fan blade Split AC/Win AC of Capacity 1.5 Ton/2.0 ton.
Supply and fixing of swing motor 12V with flapper in replacement suitable for split type ACs of capacity 1.5/2.0TR complete all as specified and directed.
Supply , installation including brazing, jointing copper tubing supirior quality, thickness greater than 0.7 mm of outer unit to inner unit assembly of suitable size for split AC. complete all as specified and directed by Engineer-in-Charge. Make: Hitachi/toteline
Supply and fixing LED display card in replacement of existing U/S LED suitable for window/split AC any type any size complete all as specified and directed.
Supply and fixing remote control hand set with required dry cell battery AAA size for existing window type air conditioner/ split type AC complete all as specified and directed. Make: LG/ Samsung/ Voltas/ Bluestar and of cap 1.5/2 ton.
Supply and fixing for outdoor unit wall mounting bracket stand suitable for 1.5/2.0ton capacity split AC outdoor unit all as per specified and directed.
Dismantling of defective indoor unit of 1.5 TR/2.0 TR capacity split type AC and supply and fixing new indoor unit(Hot &Cold) of the same capacity in working condition with blower motor, front grill and all other connected items and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit in wall/ceiling mounted complete all as specified and directed. (Make:-Totaline/BlueStar/LG/Voltas/Daikin/Hitachi)
Dismantling of defective outdoor unit of 1.5 TR/2.0 TR capacity split type AC and supply and fixing new outdoor unit(Hot&Cold) of the same capacity in working condition with blower motor,fan, and condensing unit of copper, and cabinet and all other connected electricals and items for connecting with indoor unit and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with refrigerant gas as required with stand and installing the unit in wall/ceiling mounted complete all as specified and directed. (Make:-Totaline/BlueStar/LG/Voltas/Daikin/Hitachi)
Supply and fixing FR PVC sheathed, 3 core copper conductor flexible cable of size 2.5 Sqmm with thimbles of suitable size & shape complete all as specified and directed. (Make : -FINOLEX// HAVELL'S/ POLYCAB/KEI INDUSTRIES LTD)
Servicing of refrigerator of any make and capacity, opening the refrigerator and replacing the defective parts including disconnecting electric connection and reinstalled the same after repair/replacement and testing Complete all as specified and directed by Engineer-in-Charge (Labour included for fixing charges. item required will be measured and paid separately). Note :- (i) Replacement of defective spares for making the refrigerator units in satisfactory working condition Excluding major parts like compressors will be measued & paid separately under relevent items and labour charges for taking out old spares and refixing f new spares shall deemed to included in unit quoted rate.
Taking down old unserviceble compressor of any make/model from refrigerator of capacity 300 / 310 L and supply and fixing new sealed compressor of same make in place of old compressor, replacing liquid line filter and capillary tube suitable for refrigrant with necessary brazing work, including charging of refrigerant R 22/R 134 to obtain adequate cooling complete all as specified and directed.
All as per Srl item No. 50 above but 1/8 HP for 165/180/210 Ltrs capacity.
Taking down old unserviceble compressor of any make/model from deep freezer and supply and fixing new sealed compressor in place of old compressor, replacing liquid line filter and capillary tube suitable for refrigrant with necessary brazing work, including charging of refrigerant R 22/R 134 to obtain adequate cooling complete all as specified and directed. Make: Blue Star/LG/Voltas/Whirlpool
Supply and fixing of condensing coil made out of copper tubing including brazing to unit and leak testing including refilling refrigerant gas in complete unit suitable for 165L - 250 L refrigerator unit as per sample complete all as specified and directed by Engr-In-Charge.
Supply and fixing of condensing coil made out of copper tubing including brazing to unit and leak testing including refilling refrigerant gas in complete unit suitable for 280 - 310 L refrigerator unit as per sample complete all as specified and directed by Engr-In-Charge.
Supply and fixing of the new freezer door panel and gasket as per existing make and design by removing old u/s door panel and gasket from refrigerator of any capacity Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC stand for refrigerator of capacity 280/300/310 Ltrs Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing over load/starting relay suitable for any make of refrigerator complete with testing and commissioning for the capacity of 280/300/310 Ltrs complete all as specified and directed by Engr-in-Charge.
Supply and fixing over load/starting relay suitable for any make of refrigerator complete with testing and commissioning for the capacity of 165/180/210 Ltrs complete all as specified and directed by Engr-in-Charge.
Supply and charging gas R-134 for top up for refrigerator of any make and capacity complete all as specified.
Servicing of voltage stabilizers AC single phase 2 to 5 KVA of any make by opening of the body, cleaning of internally, checking and tightening of all terminal connections and replacing of defective parts including disconnecting electrical connection and reinstalled the same after repair/replacement and testing complete all as specified and directed by enfr-in-charge, Note :- (i) Replacement of defective spares for making the Voltage stabilizer in satisfactory working condition will be measued & paid separately under relevent items and labour charges for taking out old spares and refixing new spares shall deemed to included in unit quoted rate.
Supply and fixing buck and boost relay of voltage stabilizer of capacity upto 5 KVA all as specified and as directed by Engineer-in-Charge. Make-Bluebird/Volina
Supply and fixing voltmeter to voltage stabilizer of any capacity 0-300 V all as directed by Engineer-in-charge. Make-Bluebird/Volina
Supply and fixing electronic control PCB of voltage stabilizer of capacity upto 5 KVA all as specified and as directed by Engineer-in-Charge. Make-Bluebird/Volina
Supply and fixing new auxiliary transformer for the 3.0 KVA to 5.0 KVA capacity stabilizer.
Supply and fixing trigger transformer to voltage stabilizer of capacity upto 5 KVA as directed by Engineer-in-Charge. Make-Bluebird/Volina
Supply & Install Voltage stabilizer wall mounted Electronic type with input & Output display, Overload & under voltage Relay ,time delay relay : single phase naturally air cooled indoor type & designed for input variation between 140 V to 260 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA. Make : V guard/Microtek/Luminous/Godrej
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20Amps MCB 240V AC 50Hz. Make: Legrand/L&T/ABB/Havells.
Supply and fixing Plug top 20 Amp 2 pin and earth in replacement, complete all as specified and as directed. Make: Havells/Anchor/Legrand
Supply and fixing Plug socket 20 Amp 2 pin and earth in replacement, complete all as specified and as directed. Make: Havells/Anchor/Legrand
Carrying out servicing of DG set of capacity 100 KVA, Make: Kirloskar/Cummins in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel including opening of upper portion of diesel engine including taking out heads, pistons, water sleeve, inlet and exhaust valve to facilate the repair work and replacement of defective/unserviceable parts (parts to be replaced will be measured and paid separately), adjustment of tappet of engine with the help of filler gauge for proper movement of valves by service engineer / service technician of any reputed service center / auth service center of OEM, and replacement of unserviceable spare parts/accessories including calibration of control devices/ refitting of serviceable parts after cleaning/servicing, cleaning of oil sump and replacement & including minor accessories including draining of oil, sludge/ dust from foundation/base plate and Assembling of engine after carrying out overhauling work and testing the same for its firing, prevention of any leakage and testing the same to the satisfaction of Engineer -In-Charge. Note:- All defective parts shall be paid & measured separately.
(i) Supply only following parts to be fixed under above item for DG set of capacity 100 KVA, Make: crompton greaves fuel filter primary. (one new will be replaced during routine maintinance due after overhauling)
(ii) Supply only Fuel filter secondary for DG set of capacity 100 KVA (one new will be replaced during routine maintinance due after overhauling).
(iii) Supply only Lub oil filter for DG set of capacity 100 KVA (one new will be replaced during routine maintinance due after overhauling).
(iv) Supply only Air cleaner filter for DG set of capacity 100 KVA.
(v) Supply only Hose pipe set with clamps DG set of capacity 100 KVA.
(vi) Supply only Flexible pipe with end connector for DG set of capacity 100 KVA.
(vii) Supply only Fan belt for charging alternator for DG set of capacity 100 KVA.
(viii) Supply only Fan belt for radiator for DG set of capacity 100 KVA.
(ix) Supply only Stop solenoid actuator for DG set of capacity 100 KVA.
Carrying out servicing of DG set of capacity 160 KVA, Make: Kirloskar/Cummins in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel including opening of upper portion of diesel engine including taking out heads, pistons, water sleeve, inlet and exhaust valve to facilate the repair work and replacement of defective/unserviceable parts (parts to be replaced will be measured and paid separately), adjustment of tappet of engine with the help of filler gauge for proper movement of valves by service engineer / service technician of any reputed service center / auth service center of OEM, and replacement of unserviceable spare parts/accessories including calibration of control devices/ refitting of serviceable parts after cleaning/servicing, cleaning of oil sump and replacement & including minor accessories including draining of oil, sludge/ dust from foundation/base plate and Assembling of engine after carrying out overhauling work and testing the same for its firing, prevention of any leakage and testing the same to the satisfaction of Engineer -In-Charge. Note:- All defective parts shall be paid & measured separately). Carrying out top over hauling of DG set 100 KVA
(i) Supply only following parts to be fixed under above item for DG set of capacity 160 KVA, Make: crompton greaves: Fuel filter primary. (one new will be replaced during routine maintinance due after overhauling)
(ii) Supply only Fuel filter secondary for DG set of capacity 160 KVA (one new will be replaced during routine maintinance due after overhauling).
(iii) Supply only Lub oil filter for DG set of capacity 160 KVA (one new will be replaced during routine maintinance due after overhauling).
(iv) Supply only Air cleaner filter for DG set of capacity 160 KVA.
(v) Supply only Hose pipe set with clamps DG set of capacity 100 KVA.
(vi) Supply only Flexible pipe with end connector for DG set of capacity 160 KVA.
(vii) Supply only Fan belt for charging alternator for DG set of capacity 160 KVA.
(viii) Supply only Fan belt for radiator for DG set of capacity 160 KVA.
(ix) Supply only Stop solenoid actuator for DG set of capacity 160 KVA.
Material and labour for water sleeve assembly of 100 KVA/160 KVA DG including cleaning and smoothing of bore of engine top block and testing the same for free movement of piston in the sleeve complete all as specified and directed.
Servicing cleaning of radiator of DG set of capacity 160 KVA by taking out the radiator from existing foundation and removal of light deposit with the use of low pressure stream jet and immersion in a healed alkali degreasent solution for 20 minutes for stubborn deposits and washing off with hot water hose and re-installation of the radiator to the satisfactory of engr-in- charge.
Ditto all as per item serial No-73 above but of capacity 100 KVA DG set.
Cleaning of alternator unit of DG set of capacity 100 KVA to 160 KVA with the help of air blower to wipe dust, oil or any other unwanted liquid /solid from winding of alternator after disconnecting all electric connection and recircuit the connection after carrying out the repairscomplete all as specified and directed.
Supply and fixing charging alternator 12 V suitable for DG set 100/160 KVA including US dismantling all as directed.
Supply and filling lubricant oil 20w40/15W40 (As directed by Engr-in-charge) for topping up/replacement including draining out old oil from engine chamber complete all as specified and directed. Make: Castrol/Volvoline/Servo/HP.
Supply and topping up heavy duty concentrate / antifreeze type coolant in radiator assembly of DG set complete including draining out of used coolant all as specified and directed. Make: Castrol/Volvoline/Servo/HP.
Dismantling and rewinding of electric motor 3 phase 415 volts Capacity 2 to 5 HP with super enameled copper wire gauge as existing size and varnishing complete including replacement of ball bearing 02 Nos in each, complete all as specified and directed.
Supply battery 12 V, 180 AH, complete with all connected items and warrenty card duly filled and stamped by the autherised dealer all as specified and directed. Make: Exide
Supply and fixing battery charger of 12 V , 10 amps capacity digital type with input voltage 170V-300V AC & output voltage 12V, 24V complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. Make: Havells/ABB/L&T
Supply and fixing Sub main wiring with PVC insulated cable 2 single core 4 sq mm 1100 V grade with stranded copper conductor in and including rigid PVC casing capping on wall (ISI marked) incl all specials like joint elbow, Tee ,junction , bend etc and provision of PVC insulated copper conductor single core 4 sq mm for earth continuity all as directed. Make: finolex/havells/polycab
Supply only teflon tape for ACs of size 25mm wide and 25 metre long, complete all as specified and directed.
Supply only PVC electrical insulation tape of size 1.8 cm wide and 8 metre long, complete all as specified and directed. Make: steelgrip
Supply and fixing of ML contactor of following capacity complete testing and commisioning as per requirement complete all as specified and as directed. (i) ML4 contactor 40A 3 poles
(ii) ML3 contactor 40A 3 poles
(iii) ML2 contactor 25A 3 poles Note for all items of BoQ :- (i) All repair work shall be carried out only by authorised person qualified in the relevant trade. (ii) All componant/spare parts changed in various jobs in this schedule if will become defective during contract period has to be replaced by the contractor without any extra cost. (iii) Make of components replacement if not specifically mentioned in the relevant item same shall be of the existing make. (iv) Contractor's mechanic must have to attend the regular day to day complaint within 24-48 hr from the complaint recieved from Engr-in-charge.
M/S LATIF AHMAD MIR
M/S Razdan Buildersand suppliers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .