CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
COMPREHENSIVE MAINTENANCE OF SENSITIVE E/M EQUIPMENTS AND INSTALLATIONS OF NCN DATA CENTRE AT NRS THANE, REPAIR/ MAINT OF CENTRAL AC PLANT, FIRE FIGHTING, WATER SUPPLY AND LIFT AT ASRS WED, MANKHURD UNDER CWE (SUBS) MUMBAI
2026_MES_788895_1
8823/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
MANKHURD
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) MANKHURD
₹2.2 L
11 Sept 2026
11 Sept 2026
12 Oct 2026
11 Sept 2026
9 Oct 2026
2 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive Preventive maintenance and check-up of 5TR capacity each PAC - 3Nos (precision air conditioner) installed at Equipment room of NCN (Naval communication network) data centre including complete checking of the refrigeration system, fan motor, control cards, Humidity bottle, dehumidify fire and other respective parts to ensure the healthy condition of the all indoor and outdoor units, checking the functioning of the compressor and its other accessories, cleaning of the outdoor with suitable solution, outdoor condenser coil, indoor filters microprocessors PCB card, checking the suction and discharge pressure of each units, checking of all respective sensors. The tenderer shall attend the all breakdown complaints whenever required at any time and made serviceable with in 48hrs time all as specified and as directed Make- Blue box/ Swegon, Model: DATATEC VEDA18-1 CH | 11 | Per Month | - | - |
| 2 | Preventive maintenance and check-up of 40KW capacity each- 6Nos the liquid cooling package (LCP): Unit installed at NCN Data centre including complete checking of the EC fans, control cards, Humidity bottle, dehumidify fire, actuator valves, temperature and humidity sensor, and other respective parts to ensuring the healthy condition of the all units, Checking the functioning of the compressor and its other accessories, cleaning of the indoor filter’s microprocessors PCB card, checking of all respective sensors and external cleaning with suitable solution. The tenderer shall be attending the all-breakdown complaints whenever required at any time and made serviceable with in 48hrs all as specified and as directed Make- Rittal, CMC-III, CMC Power supply, CMC IO Units | 11 | Per Month | - | - |
| 3 | Comprehensive Preventive maintenance and check-up of 500 CFM capacity each- 4Nos : the Air handling unit installed at NCN Data centre including complete checking of the refrigeration, fan motor, EC fans, control cards, and other respective parts to ensuring the healthy condition of the all units, Checking the functioning of the compressor and its other accessories, cleaning of the indoor filter’s microprocessors PCB card, checking of all respective sensors and proper external cleaning with suitable solution. The tenderer shall be attend the all-breakdown complaints whenever required at any time and made serviceable with in 48hrs all as specified and as directed Make- Balance, Model-BDFM-05 | 11 | Per Month | - | - |
| 4 | Comprehensive Preventive maintenance and check-up of chiller units of 22 TR capacity Each 3 No's: the Chiller Plant installed at NCN Data centre including complete checking of the checking the refrigeration system, fan motor, control cards and other respective parts to ensuring the healthy condition of the all Chiller units, Checking the functioning of the compressor and its other accessories, cleaning of the outdoor, outdoor condenser coil, microprocessors PCB card, checking the suction and discharge pressure of each unit, checking of all respective sensors, and external cleaning with suitable solution. The tenderer shall attend the all breakdown complaints whenever required at any time and made serviceable with in 48hrs all as specified and directed. Make- Blue box/ Swegon, Model: ZP182KCE-TFD-477 | 11 | Per Month | - | - |
| 5 | Comprehensive maintenance and routine check-up of chilled water pump motor of capacity 5 HP each- 03 Nos complete all as specified and as directed on monthly basis/per requirement to ensure the working of all machineries without breakdown of AC supply to the NCN with all materials and labour for smooth functioning of plants. | 11 | Per Month | - | - |
| 6 | Comprehensive Preventive maintenance and check-up of VRF Ductable and Split AC unit: Ductable unit Capacity-5.5TR each 2 No’s, Split AC- 02 Nos installed at NCN Data centre including complete checking of the checking the refrigeration system, fan motor, control cards and other respective parts to ensuring the healthy condition of the all Chiller. Checking the functioning of the compressor and its other accessories, cleaning of the outdoor, outdoor condenser coil, microprocessors PCB card, checking the suction and discharge pressure of each unit, checking of all respective sensors and external cleaning. The tenderer shall be attend the all-breakdown complaints whenever required at any time and made serviceable with in 48hrs. all as specified and directed Make: Recommended by OEM (Hitachi) | 11 | Per Month | - | - |
| 7 | Preventive maintenance and routine check-up of the indoor VRF cassette units :of 2.5 TR capacity model No. RCI-2.5 FSKDNQ- 08 Nos, Ceiling Suspended units, at NCN data centre, clean with mild Air blower in the coil side and remove the inside fine filter, cleaned with Soap solution after cleaning process fix in proper place ,check the drainage water tank and cleaned ,replace the communication cables and sensor if found defective including all kind of replacement of minor spare parts. Make: Recommended by OEM (Hitachi) Note:- contractor shall be responsible for replacement of false ceiling, if damage occurred while servicing of Ceiling suspended units. | 11 | Per Month | - | - |
| 8 | Preventive maintenance and routine check-up of the outdoor VRF units: 10 HP capacity Model No. RAS-10HNBCMQ1 - 2 Nos, 14 HP capacity Model No RAS-14HNBCMQ1 1 Nos. having Inverter Compressors, installed at NCN Data Centre including clean with Air blower of condensing coil, outdoor fan motors, replace the communication cables and sensor if found defective, all kind of repair cost of replacement of minor spare parts. Make: Hitachi | 11 | Per Month | - | - |
| 9 | Comprehensive Preventive maintenance and check-up of the Daikin AC 5TR capacity -2 Nos: installed at NCN Data including complete checking of the checking the refrigeration system, fan motor, control cards and other respective parts to ensuring the healthy condition of the all units. Checking the functioning of the compressor and its other accessories, cleaning of the outdoor and indoor units, outdoor condenser coil, micro processors PCB card, checking the suction and discharge pressure of each unit, checking of all respective sensors and external cleaning. The tenderer shall be attend the all-breakdown complaints whenever required at any time and made serviceable with in 48hrs time for above mentioned all as specified and directed Make- Daikin | 11 | Per Month | - | - |
| 10 | Comprehensive maintenance and routine check-up of the fire detection and Suppression system: installed at NCN Data Centre including inspection of complete panel and carry out preventive maintenance with relevant PM checklist, checking pressurised HFC227ea extinguishing cylinder and its pipe line, checking the all-control wiring, fire panel, Smoke & heat detector, relay module, VESDA and power supply etc as per installed in data centre area. Attending to all breakdown complaints whenever required. Note: Replacement/repair of all spares covered under the scope of fire detection system included in the above quoted rate by Contractor. Make- SIEMENS | 11 | Per Month | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tender.pdf
Tender Documents • 2.27 MB
BOQ_884285.xls
BOQ • 0.71 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .