Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.4 LAccepted-AOC AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | ₹89.4 L Quoted ₹91.7 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹1.1 Cr+₹13.5 L (14.7%)Rejected-Finance | ₹1.1 Cr+₹13.5 L (14.7%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹1.1 Cr+₹15.2 L (16.6%)Rejected-Finance HOUSE NO 59 ZOO NARENGI ROAD GEETANAGAR GUWAHATI 781021 ASSAM | KAMRUP METRO | ASSAM | 781021 | ₹1.1 Cr+₹15.2 L (16.6%) | L3 | Rejected-Finance Other than L1 |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
6 Jul 2024, 6:00 pmClosed
CWE Shillong
HQ CWE Shillong, SE Falls, Shillong - 793011
SPECIAL REPAIR TO BLDG NO. P-30 AND P-31 UNDER GE NARANGI
2024_MES_656443_1
8772/NAR/E8
Open Tender
Civil Works
Item Rate
180 days
Guwahati
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE Narangi
₹1.8 L
Yes
6 Nov 2024
29 May 2024
8 Jul 2024
29 May 2024
6 Jul 2024
22 Jun 2024
Amount
Dismantling plain or corrugated steel sheeting any gauge, thickness including nainital or similar pattern in roof or wall covering complete all as specified and as directed by Engr-in-Charge at site.
Supply and fix pre painted galvalume aluminum zinc coating GI based corrugated or trapezoidal shape steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engr-in-Charge at site.
Supply and fix pre painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick, of any colour having tensile strength of 550 Mpa as in ridges, valley gutters, roof covering, cladding, fixed with self tapping screws complete all as specified and as directed by Engr-in-Charge at site.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets of any thickness, including cover fillets complete all as specified and as directed by Engr-in-Charge at site.
Supply and fix GI framework (SNAP GRID) for false ceiling using E-grid (exposed ceiling suspension system) of grid size 600mm x 600mm with main runner of 38mm x 24mm and wall angle 24mm x 24mm and providing and including 4mm thick Non Asbestos fiber cement designer board (E-Board classic) in the grid of GI system, duly suspended with 4mm dia GI bar hanger, fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, providing necessary positions for light fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detectors etc.; The main runners to be secured to structural soffits by hanger @ 1220mm maximum c/c, the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall, flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm grid complete all as specified and as directed by Engr-in-Charge at site.
Demolition of Brick work including all quoins, arches, pillars etc built in cement mortar complete all as specified and as directed by Engr-in-Charge at site.
M & L for brick work with sub class B bricks straight or curved on plan exc 6 mtr mean radius, built in CM 1:6 complete all as specified and as directed by Engr-in-Charge at site.
All as per item No 7.00 above but except bricks complete all as specified and as directed by Engr-in-Charge at site.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed by Engr-in-Charge at site.
Taking down cement plaster any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by Engr-in-Charge at site.
M & L for rendering 10mm thick in CM 1:6 on fair faces of brickwork or concrete surfaces, finishing rendering even and fair complete all as specified and as directed by Engr-in-Charge at site.
M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth, without using extra cement, complete all as specified and as directed by Engr-in-Charge at site.
M&L for preparation of newly plastered surfaces of wall and applying three coats of colour washing complete all as specified and as directed by Engr-in-Charge at site.
M & L for preparation of old decorated plastered surfaces of wall and applying two coat of colour washing complete all as specified and as directed by Engr-in-Charge at site.
M&L for complete removal of existing treatment on wall and applying one coat of 3mm thick Birla White wall care putty and two coats of oil bound distemper over a coat of primer on wall care putty complete all as specified and as directed by Engr-in-Charge at site.
Complete removal of existing treatment on plastered surfaces of wall/ roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean,free from dust, loose paint etc by engaging skilled labour complete all as specified and as directed by Engr-in-Charge at site.
M&L for providing one coat of acrylic water based exterior grade primer @0.9 ltr (undiluted)/10 sq mtrs diluted with water in 1:1 ratio, to be applied with fully automatic airless spray machine, with a flow speed of minimum 1 ltr per minute, having a pressure of 3300 PSI, Allowing 6-8 hrs to dry the surface for painting of subsequent coats over primer complete all as specified and as directed by Engr-in-Charge at site.
M&L for providing two coats of water based premium acrylic smooth exterior emulsion, of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram/ litre, as per the LEEDS specifications, Anti-fungal (Algae) properties in two coats @ 1.79 ltr (undiluted)/ 10 sqm, diluted with water as per manufacturer's instructions, applied over priming coat provided under BOQ item No. 16.00 with fully automatic airless spray machine with a flow speed of minimum 1 ltr per minute, having a pressure of 3300 PSI and allowing 6-8 hrs for first coat to dry before application of second coat complete all as specified and as directed by Engr-in-Charge at site.
M&L for preparation of old painted steel surfaces, of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engr-in-Charge at site.
M&L for preparation of old decorated steel surface, exceeding 10 cm in width and girth and applying two coats of aluminium paint, complete all as specified and as directed by Engr-in-Charge at site.
Taking down chowkats or frame with shutters (without taking off shutters from the frame), not exceeding 1.50 Sqm each complete all as specified and as directed by Engr-in-Charge at site.
All as per item No. 20.00 above but exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and as directed by Engr-in-Charge at site.
Supply and fix Anodized aluminium powder coated sliding glazed window shutter (double leaf glazed shutter and single leaf mosquito proof shutter each in single frame work) WITH FRAME without sash bars with anodized aluminium shutter of section 40.00mm x 20.00mm x 2mm thick, and window chowkats/frames of section 92.00mm x 29.50mm x 2mm thick, including necessary jointing cleats, glazing clips, rubber packing, snap on beading for fixing glass panes in frames, screws, handle, tower bolts and locking arrangement etc. and providing and including 4mm thick sheet glass, tinted quality on panel and aluminium anodized wire cloth for mosquito proofing, 0.45mm nominal dia and average width of aperture 1.40mm, fixed with aluminium screws and tacks and making good to disturbed surfaces complete all as specified and as directed by Engr-in-Charge at site. NOTE: Providing glazing and wirecloth to windows including all hardware is included in the rates quoted for this item.
S&F Steel windows for industrial buildings, with centre hung shutters including brass pivots, catch spring and pulley wheel complete all as specified and as directed by Engr-in-Charge at site. NOTE: Glazing and painting to steel windows shall be measured and paid separately under respective items in this BOQ.
M&L for plain cement concrete (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in hold fast block or bed block complete all as specified and as directed by Engr-in-Charge at site.
S&F 4.8 mm thick, sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane, complete all as specified and as directed by Engr-in-Charge at site.
S&F 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed by Engr-in-Charge at site.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engr-in-Charge at site.
S&F Rolled Mild Steel Structural Steel work as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of grade Fe-410W (Gde E-250) Quality B, complete all as specified and as directed by Engr-in-Charge at site.
M&L for preparation of old painted plastered wall surfaces, of any description, not otherwise described, over 10cm width or girth and applying two coats of plastic emulsion paint over a coat of primer complete all as specified and as directed by Engr-in-Charge at site.
M&L for preparation of new or previously untreated surfaces of steel and steel based surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and as directed by Engr-in-Charge at site.
Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) including removal of spoils/ demolished material to a distance not exceeding 100m and depositing where directed at a level not exceeding 1.5 mtrs above the starting point, complete all as specified and as directed by Engr-in-Charge at site.
M&L for 25 mm thick plain cement concrete, 1:2:4, type B1, (using 20 mm graded stone aggregates) as in floors or sub bases or levelling cource, finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge at site.
(i) Preparation of Surfaces :- M&L for preparation of concrete surfaces and should be free from contumnation such as mortar, paint splashes, oil, grese, etc. Excessive laitance should be removed by light mechanical grinding followed by vacuum cleaning. (ii) Application primer:- It shall be ensured that the surface is bone dry during the application of primer Bostik prime coat/HFP 120 of Asian Paints Ltd. The 2 part system shall be mixed mechanically using a slow HFP 120 of Assian Paints speed heavy duty drilling machine (400 to 500 rpm) fitted with suitable peddle to achieve homogeneous mix. The mix material applied by brush allowed to dry completely total thickness of primer should be 50 micron (dry thickness). (iii) Underlay Screed :- When the primmer coat reaches tack free state, the basses, filler and hardener of the epoxy resin bostik epoxy underlay screed shall be mixed using a slow speed heavy suty drilling machine (400 to 500 rpm) fitted with a suitable paddle to achive homogeneous mix and applied on the primer surface using trowel application as the layer screed at 2 mm thickness. Spike roller shall be applied to the surface for uniformness and allowed to dry. Total thickness of screed should be 2 mm. (iv) Application of Epoxy PU Self Leveling top coat :- When the above Epoxy underlay screed gets dry, the base, hardener, color paste and filler of the Epoxy self leveling shall be mixed mechanically as described above and applied over the underlay surface by trowel application. Apply spike roller to get a uniform finish and allowd to dry. Thickness of topping should be 1mm and toltal thickness of system will be 3mm.
M&L for 100 mm thick plain cement concrete (1:2:4) type B2 using (40 mm graded crushed stone aggregate) as in floors/ sub base of tiles/floor of hard standing/path etc and finishing the surface even and fair, complete all as specified and as directed by Engr-in-Charge at site.
M&L for providing 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded crushed stone aggregate) as in plinth protection, concrete shall be laid in alternate bays n exc 2 sqm each with 10 mm thick joints in consecutive bays, cement concrete surface finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge at site. NOTE: Forming of joints shall be measured and paid separately under respective item of this BOQ.
M&L for Forming Construction joint in plinth protection, of size 30mm deep x 10mm wide, filled with sealing compound of grade A, complete all as specified and as directed by Engr-in-Charge at site.
M&L for 100mm thick PCC 1:2:4, Type B-2 i.e. M-15 (nominal mix) as in surface channels and drains Including necessary formwork complete all as specified and as directed by Engr-in-Charge at site.
Dismantling floor, hearth or wall tiling, including cement mortar bedding (but not backing), removing rubbish off the premises away from site complete all as specified and as directed by Engr-in-Charge at site.
M&L for glazed ceramic coloured tiles in vertical surface of size 300mm x 200mm x 7mm thick, set and jointed in neat cement slurry and pointed in coloured cement to match colour of tiles as in vertical surfaces such as skirting, dados and risers to steps fixed over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed by Engr-in-Charge at site.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or metal frames or aluminium frames including punching or drilling out old glazing pins / spring clips or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed by Engr-in-Charge at site.
S&F Rough cast wired glass, 6.4mm thick and glazing with oil putty in square n. exc. 0.50sqm in each pane complete all as specified and as directed by Engr-in-Charge at site.
M&L Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and as directed by Engr-in-Charge at site.
M&L for 12mm thick Prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work/ aluminium frame work complete all as specified and as directed by Engr-in-Charge at site.
M&L for providing powder coated aluminium (minimum thickness of powder coating 50 microns) for sliding glazed window shutter WITH FRAME (double leaf glazed shutter and single leaf mosquito proof shutter each in single frame work) without sash bars with powder coated aluminium shutter of section 40.00mm x 20.00mm x 2mm thick and window chowkat of section 92.00mm x 29.50mm x 2mm thick including necessary jointing cleats, glazing clips, rubber packing, snap beading, screws, handle, tower bolts and locking arrangement etc. and including 4mm thick sheet glass, tinted quality on panel and aluminium anodized wire cloth for mosquito proofing, 0.45mm nominal dia and average width of aperture 1.40mm, fixed with aluminium screws and tacks and making good to disturbed surfaces complete all as specified and as directed by Engr-in-Charge at site.
M&L for providing powder coated push pull type fully glazed door shutter (single leaf / double leaf) having top rail of section 85.00mm x 44.45mm x 2.00mm, bottom rail of section 85.00mm x 44.45mm x 2.00mm thick, door verticals of section 44.45mm x 44.45mm x 2.00mm thick and lock rail of section 85.00mm x 44.45mm x 2.00mm thick with aluminium powder coated chowkats of section 63.50mm x 33.10mm x 2.50mm thick including necessary jointing cleats, glazing clips, rubber packing, snap beading, screws, handle and locking arrangement, and providing and fixing and including 5.5 mm thick float glass tinted quality on top/bottom panel complete all as specified and as directed by Engr-in-Charge at site. Note : Door closer shall be measured and paid separately.
Demolition of cement concrete (reinforced) of any description and any position not otherwise specifically provided for, complete all as specified and as directed by Engr-in-Charge at site.
M&L for RCC 1:1½:3 type A1(20mm graded stone aggregate) nominal mix as in beams, seimic bands, cantilevers, bressumers and lintels etc complete all as specified and as directed by Engr-in-Charge at site.
Use and Waste for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. rough finished surface of concrete complete all as specified and as directed by Engr-in-Charge at site.
M&L for MS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engr-in-Charge at site.
All as per Srl Item No. 48.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed by Engr-in-Charge at site.
Dismantling stone slabs and tiles of any description or thickness in floors/aprons laid bedded and pointed in any mortar, and removing away from site complete all as specified and as directed by Engr-in-Charge at site.
M&L pre-polished cement concrete chequered tiles, area of each tiles exc 0.06 Sqm but n exc 0.11 Sqm and 25 mm thick with white cement and pigments, of approved make, jointed with cement slurry and pointed with white cement mixed with pigment to match with the tiles laid over and including cement mortar screed bed of 20 mm thick in cement mortar (1:6) complete all as specified and as directed by Engr-in-Charge at site.
Taking down rolling shutter of any type for repairs/ replacement of defective components such as rolling system and pulling system, re-assembling the whole rolling shutter including greasing complete, welding, drilling where required and refixing the shutter in the same opening complete, area of each shutter exc 20 sqm but not exc 50 sqm each, complete all as specified and as directed by Engr-in-Charge at site. NOTE: (i) All the shutters shall be removed carefully with accessories without damaging the adjacent structures. (ii) Contractor shall lay out all the defective parts of removed shutter at site and after verification by Engr-in-charge, defective parts shall be replaced with new fitting/items. (iii) The new fixtures/items/parts shall be paid extra at supply only rates. (iv) All the repaired parts/accessories, along with new parts/accessories shall be reassmebled and fixed to the satisfaction of Engr-in-charge in existing postion. (v) The cost for necessary greasing, easing etc for full proper functioning of the shutter, is included in the rate quoted for this item. (vi) The defective/ removed parts/ accessories of rolling shutter shal become the property of the contractor at Sch of Credit rates under Srl item No. 8.00 of Sch of Credit. (vii) The cost of labour require for taking down of rolling shutter, replacement of defective parts with new parts, reassembling of serviceable parts, oiling and greasing and re-erection in same or other opening is included in the rate quoted for this item.
Supply only 100 mm dia, 450 mm long, SWG 'O', high tensile spring, thickness not less than 6 mm, of size as per existing, conforming to relevent IS, complete all as specified and as directed by Engr-in-Charge at site.
Supply only roller of steel pipe (shaft) confirming to heavy duty of size 50 mm nominal bore complete all as specified and as directed by Engr-in-Charge at site.
Supply only ball bearing of No 6213/6214 complete all as specified and as directed by Engr-in-Charge at site.
Supply only locking plate made of 3.15 mm thick reinforced with mild steel angle section not less than 35mm x 35mm x 5 mm size complete all as specified and as directed by Engr-in-Charge at site.
Supply only guide channel made of mild steel deep channel section not less than 3.15 mm thick, depth of channel 75 mm, complete all as specified and as directed by Engr-in-Charge at site.
Supply only mild steel clip suitable for riveting to lath curtain complete all as specified and as directed by Engr-in-Charge at site.
Supply only lath section 1.20 mm thick for shutter width exc 35 mtr, conforming to IS-6248-1979 (section of lath shall have a distance of 75 mm between rolling center) complete all as specified and as directed by Engr-in-Charge at site.
Supply only MS sheet 1.00 mm thick as in hood cover complete all as specified and as directed by Engr-in-Charge at site.
Supply only bevel gear box and crank handle assembly complete all as specified and as directed by Engr-in-Charge at site.
Taking up or down steel water tubing of 15 mm bore from trenches, walls, ceiling or floors including all fittings, and removing away from site defective / rusted pipes and fittings complete all as specified and as directed by Engr-in-Charge at site.
Taking up or down steel water tubing of 20 mm bore from trenches, walls, ceiling or floors including all fittings, and removing away from site defective / rusted pipes and fittings complete all as specified and as directed by Engr-in-Charge at site.
S&F GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engr-in-Charge at site.
S&F GI tubing 20 mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engr-in-Charge at site.
Fixing only 15 mm bore, GI tubing medium grade with all NEW fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engr-in-Charge at site.
Fixing only 20 mm bore, GI tubing medium grade with all NEW fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by Engr-in-Charge at site.
Supply and fix IN REPAIRS Bib taps, 15mm dia, fancy type, cast copper alloy, chromium plated, with crutch or butter fly handles, screwed down for iron pipe or for brass ferrule complete all as specified and as directed by Engr-in-Charge at site.
S&F IN REPAIRS rotational moulded polyethylene water storage tank 1000 litre capacity of triple layered wall construction (Cylindrical, vertical with closed top), hoisted and fixed in position, including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule complete all as specified and as directed by Engr-in-Charge at site.
Supply and fix IN REPAIRS stop valves 20 mm dia cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or unions, and fixed complete all as specified and as directed by Engr-in-Charge at site.
S&F IN REPAIRS 110 mm dia PVC (SWR) pipes, single socketed, in any length, with rubber ring joints, laid in trenches or in floor complete all as specified and as directed by Engr-in-Charge at site.
S&F 110 mm dia PVC (SWR) bends of any radius complete all as specified and as directed by Engr-in-Charge at site.
E & M PORTION INTERNAL ELECTRIFICATION Taking down carefully aluminium/copper conductor point wiring (light,fan,socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc. and removing away from site (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified and as directed by Engr-in-Charge at site.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, 20 mm dia Stove enamelled steel conduit on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor, green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel galvanised sunken box/metal flush box made out of 1.6 mm thick galvanised sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including accessories, cutting chases and making good the disturbed surfaces in cement mortar 1:3 and painting complete to match with the existing for one light point/one fan point controlled by one switch complete all as specified and as directed by Engr-in-Charge at site.
All as per srl Item No. 76.00 above but for point wiring for Power point with 2.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, 20 mm dia Stove enamelled steel conduit on wall/ceiling and incuding provision of 2.50 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor, green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel galvanised sunken box/metal flush box made out of 1.6 mm thick galvanised sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including accessories, cutting chases and making good the disturbed surfaces in cement mortar 1:3 and painting complete to match with the existing for one switch socket 15/16 Amps controlled by one 15/16 switch complete all as specified and as directed by Engr-in-Charge at site.
S & F Switch socket combination 3 pin 16A, flush type complete all as specified and as directed by Engr-in-Charge at site.
S&F Switch piano, flush type single pole, one way 5/6 Amp complete all as specified and as directed by Engr-in-Charge at site.
Supply and fixing IN REPAIRS, LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC, recessed type with high efficiency PMMA diffuser, soft glare, free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver with and including three core flexible copper conductor cable of suitable size not less than 1 mtr in length complete all as specified and as directed by Engr-in-Charge at site.
S & F IN REPAIRS, LED light fitting 1 x 9W / 1 x 10W bulkhead luminaires including LED light driver holder and connecting up with three core flexible copper conductor cable of suitable size not less than 1 mtr in length complete all as specified and as directed by Engr-in-Charge at site.
Supply and fixing IN REPAIRS, ceiling fans, complete with blades, down rods, fan hook etc, electronic regulator and accessories, 230 V, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, Five star rated, with brushless direct current motor (BLDC) complete all as specified and as directed by Engr-in-Charge at site.
Supply and fix IN REPAIRS, exhaust fan, steel body, AC single Phase. 230V of size 450m sweep, heavy duty, with blades and frame and louvers complete all as specified and as directed by Engr-in-Charge at site.
Supply & fix IN REPAIRS, Air Circulator fans 230 volts, single phase, oscillating type 600 mm sweep, heavy duty suitable for wall mounting, complete all as specified and as directed by Engr-in-Charge at site. NOTE FOR SRL ITEM NO. 82.00, 83.00 & 84.00: Dismantled ceiling fans/exhaust fans/air circulators shall be deposited by the contractor in MES storeyard of AGE E/M office and shall be taken on charge by MES.
Supply & fixing / drawing of cables IN REPAIRS, for Sub main wiring/ wiring for circuit alongwith earth wire drawn through and including steel conduit of minimum 20mm dia, using and including PVC insulated, unsheathed cable FRLSH, 1100 volts grade with copper conductor, multistranded, single core of size 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth continuity wire include fixing arrangement fixed on MS truss/Angle in wksp bldg complete (for sheetmetal enclosure) complete all as specified and as directed by Engr-in-Charge at site.
Supply & fixing / drawing of cables IN REPAIRS, for Sub main wiring/ wiring for circuit alongwith earth wire drawn through and including steel conduit of minimum 20mm dia, using and including PVC insulated, unsheathed cable FRLSH, 1100 volts grade with copper conductor, multistranded, single core of size 2 x 6.0 sq. mm + 1 x 6.0 sq. mm earth continuity wire include fixing arrangement fixed on MS truss/Angle in wksp bldg complete (for sheetmetal enclosure) complete all as specified and as directed by Engr-in-Charge at site.
Supply and fixing / drawing of cables for sub main wiring/ wiring for circuit IN REPAIRS, alongwith earth wire drawn through and including steel conduit of minimum 20mm dia, using and including PVC insulated, unsheathed cable FRLSH, 1100 volts grade with copper conductor, multistranded, single core of size 4 x 6.0 sq. mm + 1 x 6.0 sq. mm earth continuity wire include fixing arrangement fixed on MS truss/Angle in wksp bldg complete (for sheetmetal enclosure) complete all as specified and as directed by Engr-in-Charge at site.
Supply and fixing / drawing of cables for sub main wiring/ wiring for circuit IN REPAIRS, alongwith earth wire drawn through and including steel conduit of minimum 20mm dia, using and including PVC insulated, unsheathed cable FRLSH, 1100 volts grade with copper conductor, multistranded, single core of size 4 x 10.0 sq. mm + 1 x 10.0 sq. mm earth continuity wire include fixing arrangement fixed on MS truss/Angle in wksp bldg complete (for sheetmetal enclosure) complete all as specified and as directed by Engr-in-Charge at site.
Supply and fixing / drawing of cables for sub main wiring/ wiring for circuit IN REPAIRS, alongwith earth wire drawn through and including steel conduit of minimum 20mm dia, using and including PVC insulated, unsheathed cable FRLSH, 1100 volts grade with copper conductor, multistranded, single core of size 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth continuity wire include fixing arrangement fixed on MS truss/Angle in wksp bldg complete (for sheetmetal enclosure) complete all as specified and as directed by Engr-in-Charge at site.
S&F IN REPAIRS, 240V, 20 Amps, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp SP complete all as specified and as directed by Engr-in-Charge at site.
S&F IN REPAIRS, 415V, 20 Amps, Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 20 Amps complete all as specified and as directed by Engr-in-Charge at site.
S&F IN REPAIRS, 415V, 32 Amps, Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps complete all as specified and as directed by Engr-in-Charge at site.
S&F IN REPAIRS, 415V, 63 Amps, Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amps complete all as specified and as directed by Engr-in-Charge at site.
Supply and fixing IN REPAIRS, 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed by Engr-in-Charge at site.
Supply and fixing IN REPAIRS, 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and neutral and current carrying capacity 32 AMP, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed by Engr-in-Charge at site.
Supply and fixing IN REPAIRS, 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and neutral and current carrying capacity 40 to 63 AMP, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed by Engr-in-Charge at site.
Supply & fix IN REPAIRS, Sheet metal enclsoure for DBs, double door for MCBs TPN 4 ways with 200 amps rated bus bar suitable for 1 No. MCB DP 32 Amps as incoming + 6 Nos MCB, 6-32 Amps as outgoings complete all as specified and as directed by Engr-in-Charge at site. Note: MCBs to be measured and paid seperately under relevant items in this BOQ.
Supply & fix IN REPAIRS, Sheet metal enclsoure for DBs, single door for MCBs SPN (single pole neutral) 8 ways with 200 amps rated bus bar suitable for 1 No. MCB DP 32 Amps as incoming + 6 Nos MCB, 6-32 Amps as outgoings complete all as specified and as directed by Engr-in-Charge at site. Note: MCBs to be measured and paid seperately under relevant items in this BOQ.
Supply, install, commissioning and testing IN REPAIRS, of commercial Air curtain unit of Door opening size 52" x 78" for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge, finished with one coat of red oxide primer and two coats of synthetic enamel paint with final coat of synthetic enamel paint (oven baked) with MS - CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level complete all as specified and as directed by Engr-in-Charge at site. NOTE: Old defective unserviceable air curtain shall be deposited by the contractor at MES storeyard of AGE E/M office and taken on charge by MES.
M&L IN REPAIRS, for earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.50 Mtr below ground level, earth plate connected with earth lead of 8 mm dia galvanised iron or steel wire to the earthing test point, all as shown in Electrical Plate No. 3, GI earthing lead to be protected with and including galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point; including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate, further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness), 3rd layer with tibba sand up to the ground level; providing and including pre-cast concrete earth pit in PCC (1:3:6), type C-1, (using 20mm graded stone aggregates), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including all necessary earth work and excavation in any type of soil including testing of earthing on completion, complete all as specified and as directed by Engr-in-Charge at site.
M&L IN REPAIRS, for earthing complete with Copper Earth plate of size 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.50 Mtr below ground level, earth plate connected with copper earth strip of size 20mm x 3mm by means of bolts, nuts, check nuts and washers of steel, all as shown in Electrical Plate No. 3, GI earthing lead to be protected with and including galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point; including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate, further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness), 3rd layer with tibba sand up to the ground level; providing and including pre-cast concrete earth pit in PCC (1:3:6), type C-1, (using 20mm graded stone aggregates), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including all necessary earth work and excavation in any type of soil including testing of earthing on completion, complete all as specified and as directed by Engr-in-Charge at site.
LIGHTNING PROTECTION: Taking down old defective Alluminium strip of any size as down conductor/roof conductor and removing away from site complete all as specified and as directed by Engr-in-Charge at site.
S&F IN REPAIRS, Air termination, single pointed aluminium rod 12mm dia and 300mm long, complete all as specified and as directed by Engr-in-Charge at site.
S&F IN REPAIRS, Aluminium Strip of size 25 x 3.15mm with saddles and fixing screws etc. for down conductors and roof conductors above ground level, complete all as specified and as directed by Engr-in-Charge at site.
S&F IN REPAIRS, Copper strip 20mm x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and as directed by Engr-in-Charge at site.
S&F IN REPAIRS, GI Pipe, 40mm dia, medium grade of 4.5 Mtr length fixed on roof with suitable arrangement including MS Structiure alongwith SWR stay assembly, hooks, insulator etc complete all as specified and as directed by Engr-in-Charge at site.
S&F IN REPAIRS, Test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm drilled and screwed including 3 Nos. 8mm dia 25mm long, hexagonal head screw complete all as specified and as directed by Engr-in-Charge at site.
S&F IN REPAIRS thermoplastic (Polycarbonate) junction box for test point without terminal block of dimension 130mm x 180mm x 77mm IP 66 halogen free and weather proof including four hexagonal anticorrosive screws for outdoor installation complete all as specified and as directed by Engr-in-Charge at site. Make : Hensel Cat Part No. DK 0600 G or equivalent in Syntex
AIR COMPRESSOR LINE: Supply and fixing IN REPAIRS, 40mm dia M S Pipe, heavy grade, with all fittings and fixtures of size ISI marked (IS-1239), laid in trenches or in floor, for provision of air grid compressor line of rating 10 Kg/CM2 including necessary fittings, welding joints, flange nuts & bolts etc. complete all as specified and as directed by Engr-in-Charge at site.
Supply and fixing IN REPAIRS, 25mm dia M S Pipe, heavy grade, with all fittings and fixtures of size ISI marked (IS-1239), laid in trenches or in floor, for provision of air grid compressor line of rating 10 Kg/CM2 including necessary fittings, welding joints, flange nuts & bolts etc. complete all as specified and as directed by Engr-in-Charge at site.
Supply and fixing IN REPAIRS, 20mm dia M S Pipe, heavy grade, with all fittings and fixtures of size ISI marked (IS-1239), laid in trenches or in floor, for provision of air grid compressor line of rating 10 Kg/CM2 including necessary fittings, welding joints, flange nuts & bolts etc. complete all as specified and as directed by Engr-in-Charge at site.
Supply & Fix IN REPAIRS, outlet brass Nozzel connections, fixed on Air compressor line of size 15sqmm, complete all as specified and as directed by Engr-in-Charge at site.
Supply, installing, testing and commissioning IN REPAIRS, of twin lobe, design type, air blower complete with motors, capacity 450 Cu.m/hour, pressure rating 0-10 Kg/CM2, 415V, 3 Phase 50 Hz including butterfly & NRV, V belt, safety valve, pressure guage inter connection piping, including necessary cable connection with suitable size cable from starter to Air Compressor assembly.(20HP) complete all as specified and as directed by Engr-in-Charge at site. MAKE: AKASH/EVEREST/AIRVAK. NOTE: Old defective unserviceable air blower with motors and connected accessories shall be deposited by the contractor at MES storeyard of AGE E/M office and taken on charge by MES.
Supply and fix IN REPAIRS, Pressure gauge, 100 mm dia with ball valve of pressure 0-14 Kg/Sqcm with brass isolation valve and pipe, including making hole of suitable size, complete all as specified and as directed by Engr-in-Charge at site.
EXTERNAL ELECTRIC SUPPLY: M&L IN REPAIRS, for XLPE insulated, armoured, heavy duty electric cable, with stranded aluminium conductor, 1100 Volts grade, cross sectional area 16 sqmm, 4 core laid in trenches /floor or fixed on wall with GI saddle/pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed by Engr-in-Charge at site.
M&L IN REPAIRS, for XLPE insulated, armoured, heavy duty electric cable, with stranded aluminium conductor, 1100 Volts grade, cross sectional area 25 sqmm, 4 core laid in trenches /floor or fixed on wall with GI saddle/pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed by Engr-in-Charge at site.
M&L IN REPAIRS, for XLPE insulated, armoured, heavy duty electric cable, with stranded aluminium conductor, 1100 Volts grade, cross sectional area 70 sqmm, 3½ core laid in trenches /floor or fixed on wall with GI saddle/pole including brass compression cable glands, terminal lugs etc, complete all as specified and as directed by Engr-in-Charge at site.
M&L IN REPAIRS, for earthing complete with copper earth plate electrode of size 600 mm x 600 mm x 3.15 mm thick burried directly and vertically in ground (Earth pit not less than 2.25 m deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to copper earth strip 20mm x 3mm as earth lead by means of nut, bolts check nut and washers of galvanised iron or steel etc all as shown in electrical plate No.3 of SSR part I- 2009 connected to earth test point all as specified or indicated including PCC pit in PCC (1:3:6) type C-1 cast iron MS frame, 50 mm thick pre cast RCC (1:1 1/2:3) Type A-1 nominal mixed cover slab reinforced with 8 mm dia MS deformed bar 15cm c/c and with suitable handle in cast iron including necessary exavation, earth work in any type of soil and disposal of soil to a distance n exc 50 m and charcoal 120Kg, salt 105 kg, funnel with water pipe, wire mesh, copper logs etc GI protection pipe of size 15 mm bore dia including tetsing complete including dismantling of old unservicable earthing & earth pit all as specified and directed by Engr-in-charge at site.
S&F IN REPAIRS, street light bracket made of GI pipe 40mm bore medium grade (bend to shape), minimum 1.50m long and fixed with two sets of MS flat iron clamp of size 40X5mm, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and fixed on pole complete all as specified and as directed by Engr-in-Charge at site.
S&F IN REPAIRS, street light fitting 70 Watt LED made of pressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protection and lens embedded in PC Cover having top opening, seperate driver compartment, should have luminaire efficacy ≥110 lumens/watt, CRI>70, PF > 0.95, CCT≥5500, impact resistance IK 07, inbuilt protection against lightning, over voltage, short circuit and surge/spike protection device upto 10 kV complete all as specified and as directed by Engr-in-Charge at site. NOTE : (i) PVC insulated PVC sheathed, multistranded aluminium or copper conductor cable of size 1.5 sqmmX 3 core from light fitting to Street light feeder (max 2.0 mtr) is deemed to be included in quoted rate. (ii) Manufacturer’s test certificate of LED light fitting in respect to LM 79 and LM 80 shall be submitted by the contractor.)
S &F IN REPAIRS, flood light fitting 120 Watt LED made of pressure die cast aluminium housing with toughened glass and LEDs with secondary optics and IP 66 protection and lens embedded in PC cover, having top opening seperate driver compartment, shall have luminaire efficacy ≥110 lumen/watt, CRI>70, PF > 0.95, CCT≥5500, impact resistance IK 07, inbuilt protection against lightning/ over voltage, short circuit and surge /spike protection device upto 10 KV complete all as specified and as directed by Engr-in-Charge at site. NOTE: (i) PVC insulated PVC sheathed, multistranded aluminium or copper conductor cable of size 1.5 sqmmX 3 core from light fitting to Street light feeder (max 2.0 mtr) is deemed to be included in quoted rate. (ii) Manufacturer’s test certificate of LED light fitting in respect to LM 79 and LM 80 shall be submitted by the contractor.)
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable , etc. n.exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed by Engr-in-Charge at site.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, in soft /loose soil complete all as specified and as directed by Engr-in-Charge at site.
Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and as directed by Engr-in-Charge at site.
M&L for sand cushioning using dry and clean tibba sand, in two layers, first layers of 8cm thick before laying of cable and second layer of 15cm thick after laying of cable in trenches/ducts including consolidation of each layers and punning down to 18cm total thickness complete all as specified and as directed by Engr-in-Charge at site.
Supply & Laying sub class ‘B’ bricks (old size) for cable protection laid flat and dry in trenches over cables, perpendicular to direction of cable, complete all as specified and as directed by Engr-in-Charge at site.
M&L IN REPAIRS, for GI pipe, light grade, 40mm bore, with all fittings laid in trenches or in floors, complete all as specified and as directed by Engr-in-Charge at site.
M&L for Manual boring under roads / hard standing using required T&P, without disturbing the top surface of the road, for passing the cable in GI Pipe of 40 mm dia, complete all as specified and as directed by Engr-in-Charge at site.
M/S SHASS ENGINEERS
SHIVAM TRANSCON PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .