GE(I))CAMPBELL BAY
REPAIRS AND MAINTENANC AND REPLACEMENT OF INTERNAL WIRING, INCLUDING LED FITTINGS AND MAINTENANCE OF SUMMER APLIANCES AND MISC EM SERVICES AT INS BAAZ, 3U DET, COTS RADAR AT CAMPBELL BAY
2020_MES_352082_2
8687/E8
Open Tender
Civil Works
Item Rate
180 days
CAMPBELL BAY
As per NIT
9 documents required · 9 mandatory
₹500
GE(I)CAMPBELL BAY
₹38,000
Yes
25 Aug 2020
13 Jul 2020
27 Jul 2020
15 Jul 2020
25 Jul 2020
20 Jul 2020
Amount
Taking down old unserviceable point wiring, (light, fan, socket or power) complete including fittings & fixtures such as switch, ceiling rose, pendants, regulator, socket, etc., and making good the disturbed surface of wall, floors, ceiling etc to match with the existing including touch up of paint/white wash all as specified and directed by Engineer- in-charge.
Material and Labour for point wiring with 1.5 sqmm PVC insulated, unsheathed FRLS multistrand copper conductor cable 1100 volts grade drawn into and including non metallic rigid PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour/ Capping casing as per site requirement with all conduit fittings and fixing accessories including 2.0 mm thick MS sheet terminal boxes (2 Coats of black paint over one coat of red oxide) with 3.0 mm thick phenolic laminated sheet for mounting switches, sockets, fan regulators etc incl1.5Sqmm FRLS multistrand copper conductor cable as continuous earth wire complete for the following:-(a) One light point controlled by one switch.
(b) One fan point controlled by one switch.
(d) One socket 5 Amps on same board.
(e) One socket 5 Amps on independent board.
All as per item No. 2.1 hereinbefore but with 2.5 Sqmm cable for 3 pin 15 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing of Switch piano, flush type single pole, one way 5 Amp
Supply and Fixing of Switch socket combination 2 in 1, 5 Amps flush type
Supply and Fixing of Switch Socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal
Supply and Fixing of Stepped type electronic fan regulator with 5 steps, flush type
Supply and Fixing of Ceiling rose PVC/ Polycarbonate insulated body with three terminals
Taking down old unserviceable and S & F Surface mounting 10 Watt LED Luminaries with epoxy white powder coated CRCA sheet steel housing with reeded translucent acrylic diffuser and 1 x 10 Watt LED fitting including taking down old unserviceable fittings any type complete all as specified and as directed . Make : CG , Bajaj, Wipro
Taking down old unserviceable and Supply and fix surface mounting 20 W LED Tube light fitting nominal system lumen output of 2000 lumens and a minimum system efficacy of 100 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70.The luminaire should have a color temperature of 6500K and CRI>83. pre wired connection up to tube light fitting with connecting up with copper 2 core flexible cord of minimum size 1.0Sqmm and white in colour. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The total power consumption should not exceed 20W (including driver) including taking down old unserviceable fittings any type including round block complete all as specified and as directed. Make : Phillips/Havells/WIPRO
Taking down old unserviceable and Material and Labour for sub main wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 2x4.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 4.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire complete as directed by Engr in Charge
Taking down old unserviceable and Material and labour for sub main wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 2x6.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 6.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire complete as directed by Engr in Charge .
Material and Labour for cutting chases for concealed conduit point wiring, sub main wiring and sinkings for boxes but not exceeding 10 cm girth and making good to walls, floors with 1:3 cement mortar and apply white wash or distemper matching with existing colour as directed by Engr in Charge
Taking down old unserviceable and Supply & Fix Sheet metal enclosure for DB’s Single pole and neutral, double door 240V, 4 way with 200 Amps rated bus bar. Make -Legrand/L&T/Havells
Taking down old unserviceable and Supply & Fix Sheet metal enclosure for DB’s Single pole and neutral, double door 240V, 8 way with 200 Amps rated bus bar. Make -Legrand/L&T/Havells
Taking down old unserviceable and Supply & Fix Sheet metal enclosure for TPN l, double door 240V, 4 way with 200 Amps rated bus bar. Make -Legrand/L&T/Havells
Taking down old unserviceable and Supply & Fix MCB SP 6 to 32 Amps 10 KA. "C" Series Make -Legrand/L&T/Havells
Taking down old unserviceable and Supply & Fix MCB DP 32 Amps 10 KA. "C" Series Make -Legrand/L&T/Havells
Taking down old unserviceable and Supply & Fix MCB TPN 40 to 63 Amps 10 KA. "C" Series Make -Legrand/L&T/Havells
Taking down of unserviceable PCB (permanent circuit board) and providing new PCB for AC of 1.5 / 2.0 Ton capacity.
Taking out of unserviceable swing motor and providing new swing motor of same quality and characteristics suitable for any make of AC 1.5 / 2.0 Ton split / window type
Material and Labour for shifting of split ACs of capacity 1.5/2 Ton along with all accessories to new location and fixing, testing complete all as directed. Note: - Gas charging, if required shall be paid separately under relevant items.
Dismantling old and providing new copper tubes of size 1/4 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and directed.
Dismantling old and providing new copper tubes of size 1/2 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and directed.
Dismantling old and providing new copper tubes of size 3/8 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and directed.
Dismantling old and providing new copper tubes of size 5/8 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and directed.
Taking out unserviceable switch gears like MCCBs of any size and any description from the feeder pillar boxes -04Nos and replacement of the followings:- (a) Supply and fix Moulded Case Circuit Breaker (MCCB) four pole 415 Volts of capacity 63Amps with thermal magnetic release with breaking capacity 16KA complete
(b) Supply and fix Moulded Case Circuit Breaker (MCCB) four pole 415 Volts of capacity 100Amps with thermal magnetic release with breaking capacity 25KA complete Make -Legrand/L&T/Havells
Taking down the ceiling fans/Exhaust fans of any sweep carefully from its original position and refixing the same after the carried out the repairs/rewinding and painting complete as directed by Engr in Charge
Dismantling motor of C/Fan/Exhaust fan of any sweep and over hauling complete by cleaning all dust/grease with kerosene or petrol, replacement of unserviceable bearings, bushes, split pins and nut and bolts and applying new grease for bearings, reassembling the motor and fixing the blades and testing complete as directed by Engr in Charge, (Note: Items required for repair such as Bearings, bushes will be measured and paid separately under respective items.)
(a)Supply only ball bearing for C/ fan and E/fan
(b)Supply only GM bush for C/fan and E/fan
Taking down old unserviceable and Supply and Fix capacitor 2.5 MFD for C/fan make : Havells or equivalent
Taking down old unserviceable and Supply and Fix capacitor 4.0 for Exhaust fans of up to 450mm
Supply and Fixing of MS clamp with rubber bush complete suitable for hanging for C/fans
Material and Labour for preparation old surfaces of C/ fan and Exhaust fan of any sweep and painting the with synthetic enameled paint by spraying including filling cavities with filler as directed by Engr in Charge.
Material & Labour for dismantling the motor of ceiling Fan 1200mm/1400mm Sweep by unscrewing, removing stator, rotor, bearings separately without damaging any parts, rewinding the same with fine quality of super enameled copper winding wire of suitable size & Capacity including, varnishing, drying etc, and refixing the stator and rotor perfectly to rotate smoothly and connection complete including taking out burned unserviceable copper winding wire all as directed.
All as per item No 35 above but Exhaust fans up to 380 mm sweep.
Disconnect and remove unserviceable thermostat and supply and fix thermostat suitable for existing window/ split type air conditioner of capacity 1.5/2 TR complete all as specified and directed.
Disconnect and remove unserviceable starting capacitor and supply and fix starting capacitor 100/120 MFD suitable for window/ split type air conditioner of capacity 1.5/2TR complete all as specified and directed.
Disconnect and remove unserviceable running capacitor and supply and fix running capacitor 36 MFD suitable for window/ split type air conditioner of capacity 1.5/2 TR complete all as specified and directed.
Disconnect and remove unserviceable compressor and supply and fix sealed compressor including bracing the suction/ discharge line suitable for existing window/split type air conditioner of capacity 1.5/2TR and testing on completion complete all as specified and directed.Make: - Tecumesh /copland/ Kirloskar.
Disconnect and remove unserviceable condenser and supply and fix condenser including bracing the suction/discharge line suitable for existing window/split air conditioner of capacity 1.5/2TR and testing on completion, complete all as specified and directed.Make: - Opel/Accent/Skoda.
Material and Labour for filling up & charging of R - 22/R-32/R-134a/R-410 refrigerant or type of gas as per site requirement for window/spilt type air conditioner of capacity 1.5/2TR, refrigerator and water cooler of capacity 80/40 litres after leak testing of complete system and making good by bracing complete all as specified and directed.
Removing the defective fan motor of window / split AC 1.5/2 TR and Supply and fix fan motor with blade including all connection and testing complete all as specified and directed.
Taking out unserviceable heating element of any description from geyser and supply and fix new heating element1500 watts in its original position and testing complete as directed by Engr in charge
Taking out unserviceable thermostat of any description from geyser and supply and fix new thermostat in its original position and testing complete as directed by Engr in charge
Dismantling and Taking out old unserviceable post lamp fittings and S&F integral 40 Watt LED post top lanterns with black ABS plastic spigot spun aluminium canopy, with opal acrylic diffuser and accessories integral ,Fedora hat post top lantern with clear acrylic complete all as directed. Make : CG , Phillips, GE.
Taking out old unserviceable and Supply fixing 60W LED street light/building security light with pressure die cast aluminum housing & toughened glass with IP-66 degree of protection, Individual LED's must have peanut lenses for better throw across & along the road ,with luminaire efficacy of greater than 85Lumen/Watt (Minimum lumen output of luminaire should be3800Lumens ), color rendering (CRI) of ≥ 75 and co-related colour temperature (CCT ) of 5700K (± 500K) , The luminaire should have 5KV surge protection, PF ≥ 0.95, and total harmonic distortion of THD ≤ 10% , voltage range of 140-280V should be provided. Luminaire should have top maintainable driver compartment for easy access to driver during maintenance. The Driver used must be a constant current driver with efficiency of ≥ 85% The manufacturers LOGO must be Embossed/ Engraved in the housing of the luminaire. including bracket for street light fittings made out of 40 mm dia GI pipe of light grade 1.5 m long each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 40 x 5 mm flat iron including GI Nuts, bolts and washers and painting of clamps. Make : CG LSTP-60-CDL-M or eqival, Wipro and Philips.
Taking out the existing any type fittings on ceilings and S & F 36 Watt LED Luminaire suitable for 600x600mm modular ceiling grid including frame of suitable size of above LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from 5000 total lumen. The 36 W system shall be operating at 220-240v AC supply having internal driver .IP20,surge protection 2KV ,ambient temperature -20 to 45 degree C, frequency 50 to 60 Hz ,The system efficacy must be between80-100 lumen /watt ,with 70% lumen maintenance up to 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , CRI minimum 80. PF should be greater than 0.95 , THD < 10% . Individual LED's should not be visible for glare free output, colour temperature 6500k all as directed. Make : CG , Phillips, GE.
Dismantling and taking out old unserviceable Earthing and M&L for earthing with galvanized steel earth plate electrode 60cmX60cmX6mm buried earth pit not less than 2.25m depth below normal ground level with to edge of the plate vertically to depth of not less than 1.5 m below ground level connected to & including Galvanized earth wire 4.0mm dia by mean of GI bolts & nuts etc with provision of char-coal and salt etc all as per electrical plate No-3 of SSR-2010 including RCC cover and MS angle iron frame, watering with GI pipe 20 mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc. complete all as specified and directed by Engineer-in-charge.Note : 1. Refilling of the earth pit shall be carried out with black cotton soil. 2. GI wire 4.0mm dia & GI protection pipe upto 7.5 m length will be measured under this item.
NOTE : An Amount of Rs 27,808.00/- towards Schedule of Credit shall be deducted to arrive the Contract Sum
M/S PANNER SELVAM
ANITA VARMA ENTERPRISES
RS ENGINEERING WORK
MAHESWARI CONSTRUCTIONS
CHANDER SEKER ENTERPRISE
AR CONSTRUCTIONS
V CHINNA DURAI
M/s Kamal Electrical
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .