Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC | ₹27.1 L Quoted ₹28.0 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹29.3 L+₹1.3 L (4.59%)Rejected-AOC VILL PO KUMARHATTI DIST SOLAN HP | SOLAN | SOLAN | HIMACHAL PRADESH | ₹29.3 L+₹1.3 L (4.59%) | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| 3 | L3₹29.9 L+₹1.9 L (6.66%)Rejected-AOC | ₹29.9 L+₹1.9 L (6.66%) | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
2 Jan 2023, 6:00 pmClosed
Rahul Meena, IDSE, EE, Garrison Engineer
MES OFFICE GE KASAULI DISTT SOLAN HP
REPAIR TO JOINERY, TILING, PLUMBING, PLASTERING, PERIODICAL, MISC B/R WORKS AND CERTAIN LT E/M WORKS AT KASAULI MIL STATION UNDER GE KASAULI
2022_MES_567880_1
GEK-64/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
KASAULI UNDER GE KASAULI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KASAULI
₹90,000
Yes
11 Jan 2023
7 Dec 2022
9 Jan 2023
7 Dec 2022
2 Jan 2023
21 Dec 2022
Amount
Schedule 'A' Section - I
M & L dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed .
S & F coloured Glazed ceramic tiles in vertical surface350x 250x 7mm to 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick rendering in CM 1:4, complete all as specified.
M & L Non-Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer in CM 1:4 for laying glazed tiles in floors etc. , complete all as specified complete all as specified and as directed .
-ditto- as per item no 2.00 above but as in skirting incl 10 mm thick rendering in CM 1:3, complete all as specified
Marterial and Labour for Granite (of any type) work of thickness 20mm in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.(1:4) over 20 mm thick screed bed or bedding layer in CM 1:6 for laying marble incl moulding, complete all as specified and as directed .
Rounding to edges of stone slab to ne edge, such as in steps nd other similar situatiuons complete all as specified and as directed .
M & L Coloured Prepolished chequered cement conc tiles (30cmx30cmx25mm thick) in white cement and pigment in floors etc , set and jointed in neat cement slurry, over and including 20mm thick screed bed in cement mortar 1:4 complete all as specified.
Demolition of Cement concrete of any description and in any position not otherwise specifically provided for in landing and shelves etc complete all as specified.
M&L PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of flooring all as specified and directed.
M&L PCC 40 mm thick 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in flooring making even and smppth without using extra cement all as specified and directed.
M&L 75 mm thick Plain Cement Concrete (1:3:6) type C-2 using 40 mm graded stone aggregate laid in panels in plinth protection, even & fair surfaces without using extra cement all as specified.
Demolition of Reinforcement Cement concrete of any description and in any position not otherwise specifically provided for in landing and shelves etc complete all as specified.
Material and Labour for providing Reinforced cement concrete 1:2:4 Type B1 using 20mm graded aggregate as in lintels upto 1.5m clear span, Beams, cantilevers, bressummers, shelves all as specified. Note : (Reinforce bar paid and measured separately).
Taking down cement or cement lime plaster,any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M & L for Rendering 15mm thick in cement plaster 1:4 on Brick work incl finishing surface fair and even w/o using extra cement complete all as specified and as directed .
M & L for Rendering 15 mm thick in cement plaster 1:6 on stone work incl finishing surface fair and even w/o using extra cement complete all as specified and as directed .
Material and Labour for rendering 20mm thick in cement plaster 1:4 on fair faces of stone masonry surfaces , finished fair and even smooth without using extra cement complete all as specified
M&L for preparation of plastered or unplastered new surfaces of walls of and applying two coat of cement base paint over a coat of cement priming coat of any approved tint complete all as specified & as directed.
M&L preparation of new surface applying two coats of oil bound distemper on wall over a coat of 2mm th wall care putty over coat of Priming plastered and other surfaces with alkaliresistant priming paint complete all as specified and directed.
Taking down chowkats or frames without taking down shutters from the frame exc. 1.5 sq. m but n.exc.4 sqm each complete all as specified.
Taking down shutter of any description, exc 1.0 sqm but n.exc 2.00 sqm each complete all as specified.
Taking down chowkats or frames without taking down shutters from the frame n exc. 1.5 sq. m each complete all as specified.
Taking down shutter of any description n. exc 1.0 sq.m each complete all as specified.
Taking down and refixing in same location after making nessary repair and make the shutter fit for use, shutters of any description exc 1 Sqm and not exc 2 Sqm each complete all as specified and as directed .
Supplied and Fixed IInd class HW Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints.
Supply and Fixing 35mm thick, 2nd class HW, Plain framed, factory made panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and as directed .
Supply and Fixing IInd Class HW 35mm thick, factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.20 (a) supplied and fitted to chowkats, complete all as specified.
S&F Factory made solid PVC frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with mild steel square tube, suppling and fixing in opening as per specificaiton and drawing.
M&L for Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawingsupplying & fixing in the frame at site as per specification & drawing Complete all as specified & directed.
Supply and fixing for butt hinge ISI Marked 100mm size, medium weight, cold rolled mild steel complete all as specified and as directed.
S&F in repair Aluminium anodised, barrel tower bolts of extruded section 150 mm long & fixed all as specified and directed
S&F in repair Aluminium anodised, barrel tower bolts of extruded section 200 mm long & fixed all as specified and directed
Supply and Fixing in repair 250mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extrudedsections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
S&F 100mm in repair Aluminium handles, cast type, anodised, fixed complete all as specified.
Supply and Fixing 300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified in IS No 452-1973 and as directed .
Marterial and Labour for sheet glass 4.0mm thick, ordinary quality and glazing with oil putty/wooden beads in square n exc 0.5 sq m in each pane complete all as specified and as directed .
S & F 4 mm thick frosted on one side sheet glass ordinary quality and glazing with oil putty or wooden beads in square area not exc. 0.5 Sqm in each pane complete all as specified.
Supply and Fixing for galvanized mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed .
Material and Labour for preparing new wood surfaces of any description, not otherwise descri-bed, over 10cm in width or girth, & applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified
S & F in repair of 25 mm dia fancy curtain rods, mild steel wall thickness .80mm, powder coated with fixing metal ornamental holder and side finals(in pair for each door and window)as approved, fixing with PVC wall plugs bracket and brass screws complete all as specified.
Providing pre cast cement concrete type B1 1:2:4(20mm graded aggregate) in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. , with plain fair faces, including hamfers, weatherings, throat- ing etc. and setting in mortar 1:4 complete with joints to match all as specified .
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc, for rough finished surface of concrete.
M & L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips,complete all as specified and as directed .
S & F in repair for ISI marked 15mm bore chromium plated bib tap of cast copper alloy,fancy type, screwed down, screwed for iron pipe or for brass ferrule complete all as specified
S&F in repair brass CP wall mixer 15mm dia for mixing hot and cold water screwed down for iron pipe and fixed all as specified and directed.
S & F in repair of ISI marked 15mm bore ,chromium plated stop valve/Angle valve cast copper alloy screwed down, high pressure,fancy type, screwed both ends for iron pipe or for unions, complete all as specified
S & F in repairs Pillar cock, CP 15mm bore cast copper alloy with chromium plated screwed both ends,fancy type, screwed down hidh pressure without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe fixed in repairs, complete all as specified.
S&F CP grating of 100 mm da including jointing with solvent cement all as specified and as directed
S & F in repair of 15mm size PVC connections with PTMT nuts of length 450mm complete all as specified and as directed .
S & F in repair aluminium anodised tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed .
Dismantling existing tanks of capacity exc. 250 & n. exc. 500 litre, and removing to store complete all as specified and directed.
Dismantling existing tanks of capacity exc. 500 & n. exc. 1000 litre, and removing to store complete all as specified and directed.
M&L for rotational moulded polyethylene water storage tanks 500 Ltr capacity (cylinderical vertical with closed top)hoisted and fixed in position all as specified in SSR Part 1 complete all as specified & directed.
M&L for rotational moulded polyethylene water storage tanks1000 Ltr capacity (cylinderical vertical with closed top)hoisted and fixed in position all as specified in SSR Part 1 complete all as specified & directed.
S & F in repair 15 mm bore ball brass float valves high pressure with polythene float and flynut complete screwed or iron etc complete all as specified.
S & F 20 mm bore ball brass float valves high pressure with polythene float and flynut complete screwed or iron etc complete all as specified.
Taking up or down steel water tubing and connections of 15 mm bore fixed in any position complete all as specified.
Taking up or down steel water tubing and connections of 20 mm bore fixed in any position complete all as specified.
M & L for 15mm bore GI tubing Medium grade with all fitting and fixed complete to walls and ceilings or laid in floors as in repair complete all as specified and directed .
M & L for 20mm bore GI tubing Medium grade with all fitting and fixed complete to walls and ceilings or laid in floors as in repair complete all as specified and directed .
M & L in repair Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified.
S & F in repair sheet glass self asemblyconsisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket and guard rail.
S & F in repair 600mmx450mm bevelled edge mirror of selcted qulaity glass, mounted on 6mm thick AC building board or commerical ply wood and fixed to wooden plugs with chromium plated brass screw and cup washers complete all as specified.
S & F as in repair Vitreous China wash basin, white, flat back, size 550x400mm including cutting for and pinning in ends of brackets or erecting stand and incl 32mm bore CP coupling long shank , waste pipe & fitting complete all as specified and as directed .
S&F Brass in repair CP mixer for mixing hot & cold water screwed down for iron pipe and fixed for sink and WHB all as specified and directed.
S & F as in repair 10 litre PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed .
M & L 75 mm bore PVC (SWR) floor trap , plain with grating including jointing with solvent cement etc complete all as specified
S&F 75 mm bore PVC (SWR) vent cowl, Complete all as specified and directed.
S&F of grating doom 125 mm dia with waste hole of PTMT (minimum weight 40 gm). Complete all as specified and directed.
S&F in repair for sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm all as specified.
S& F Stainless steel plate rack of size 24"X36"X10" made of 1 mm thick salem stainless steel sheet grade SS-304 with shelves, hooks and railing to keep plates vertically and horizontally, including necessary fixing arrangement fixed in repair complete all as specified.
Material and labour for 18-19 mm thick pre laminated particle board, interior grade, pre laminated one side with decorative choice lamination and other of block board or veneered particle board for external teak wood lipping, 6mm thick fixed with nails in cup board, kitchen cabinets shutters etc, fixed in repair with and including taking down existing shutters of any size and description complete all as specified and directed .
Material and labour for hasp and staple 100mm size, safety type aluminum anodized including bolt to hinge plate,catcher fixed as in repairs complete all as specified and directed.
S&F 40mm size ( & as per site requirement) continuous (Piano) hinges, mild steel and fixed in repairs, complete all as specified and directed.
Supply and fixing in repair vitreous china squatting pan, “Orissa” pattern size 580mm x 440mm white, with integral foot rests (excluding flushing cistern and flush pipe)with & including P or S trap and flushing pipe complete, set with cement concrete, fixed as in repair, complete all as specified & directed.
Supply and fixing in repair vitreous china, wash down water closet pan, white, Pedestal pattern WC with ‘P’ or ‘S’ trap, (excluding fixing bolts, flushing cistern and flush pipe), fixed as in repair complete all as specified and directed.
S &F in repair Vitreous China half stall urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinalagainst wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe.
Supply & Fixing Toilet paper holder, CP incl chromium plated brass screws and wooden plastic cleats all as specified & directed.
Material and labour for door closer hydraulically regulated aluminum (dia cast) body, designation No 3, universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 80 Kg, fixed as in repairs, complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of walls and applying two coat of oil bond distemper of any approved tint after complete removal of existing surface complete all as specified.
M&L for preparation of old plastered or unplastered surfaces of ceiling and applying two coat of OBD paint of any approved tint after complete removal of existing surface complete all as specified.
M&L for preparation of plastered or unplastered old surfaces of walls and applying one coat of oil bound distemper of any approved tint complete all as specified and directed
All as per item No 82.00 here in before but one coat of white wash on ceiling and AC plain building board surfaces as in ceiling complete all as specified and directed
Material & Labour for complete removal of existing surface applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified & directed.
M & L for preparation of old painted wooden surfaces of any description position and location not otherwise described over 10cms width or girth and applying two coat of synthetic enamel paint (ordinary tint) all as specified and as directed.
M & L for preparation of old painted wooden surfaces of any description position and location not otherwise described over 10cms width or girth and applying one coat of synthetic enamel paint (ordinary tint) all as specified and as directed.
M&L preparation of old painted steel surfaces exc 10cm in width or girth and appling one coat of synthetic enamel paint complete all as specified and directed
All as per itme No 87.00 above but two coat of synthetic enamel paint complete all as specified and directed
M&L preparation of old painted NTP/CGI/PGI or other steel roof surfaces, eaves and gutters etc exc 10 cm width or girth and applying one coat of synthetic enamel paint of any tint as approved complete all as specified
French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler with two or more coats complete all as specified & directed.
M&L for for applying 1 mm thick wall care putty of old decorated plastered or unplastered surfaces of wall complete all as specified and directed
M&L 3mm thick wall care putty on ceiling complete all as specified & directed.
S & F in repair CP Health Faucet flexible pipe of suitable length fixed to 15mm bore pipe, complete all as specified & directed.
S & F in repair brass jet spray flexible pipe of suitable length fixed to 15mm bore pipe, complete all as specified & directed.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep getting out in hard/dense soil for stay assembly/laying of cable/errection of poles etc complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L for taking out old unserviceable with supply, laying, fixing Double walled corrugated HDPE duct pipe of 50mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as directed.
All as per item No 98.00 here in before but of 90mm outer dia complete all as specified and directed.
Dismantling taking out carefully old/unserviceable UG cable of any type/ size from trenche/pole/duct/LT panel after disconnecting from OH conductors/MCCBs/joint boxes for relaying/refixing or carrying to store for Sch of Credit.
M&L for passing through pipe testing and commissioning of 1100 Volts grade 'Heavy duty' PVC sheathed armoured cable LT, XLPE insulated aluminium conductor multi stranded served with inner sheating of PVC tape armored with galvanised steel wire or tape and overall PVC sheathed of size 10 Sqmm nominal cross sectional area 2 core with suitable glands and lugs as per site requirement confirming to IS specification, complete all as specified and directed .
All as per item No. 101.00 here-in-before but 16 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 101.00 here-in-before but 25 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 101.00 here-in-before but 35 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 101.00 here-in-before but 50 Sqmm 3.5 core complete all as specified and directed.
All as per item No. 101.00 here-in-before but 120 Sqmm 3.5 core complete all as specified and directed.
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm upto test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including light grade GI watering pipe 20mm bore with funnel wire mesh and medium grade GI wire protection pipe 40mm bore up to main board complete as shown in electrical plate No 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unserviceable earthing complete all as specified and testing on completion complete all as specified and directed.Note - The units rate includes the cost of excavation & earth work in any type of soil, charcoal & salt in alternate layers, 20mm GI pipe (light grade) for watering 40mm GI protection pipe (medium grade) funnel wire mesh PCC chamber in PCC 1:3:6 type C-1 cast iron frame and 40mm thick RCC cover for pit etc & no extra payment will be made.
M&L for restraining of ACSR conductor of any size of 2 conductor on pole after disconnecting all jumpering connection & binding of insulators and redoing all jumper connection and insulator binding with aluminium conductor providing required T&P all as specified and directed.
S&F MCCB 630 Amps 4 Pole 415 V, 50 Hz adjustable thermal type ( 80% to 100% ) and adjustable magnetic setting, breaking capacity 50 KA , ICS =100 ICU with extended terminals connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-Charge.
All as per item No 109.00 here in before but MCCB 400 Amps 4 Pole, 36 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 109.00 here in before but MCCB 250 Amps 4 Pole, 36 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 109.00 here in before but MCCB 160 Amps 4 Pole,16 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 109.00 here in before but MCCB 100 Amps 4 Pole,25 KA, 415 V, 50 Hz complete all as specified and directed.
All as per item No 109.00 here in before but MCCB 63 Amps 4 Pole,25 KA, 415 V, 50 Hz complete all as specified and directed.
S&F On load change over switch, four pole with advance neutral 400 Amps, 415 V, 50 Hz conforming to IS : 13947 Part-3 connecting up in the existing panel location including taking out existing unserviceable change over switch complete all as specified and as directed and as directed by Engineer-in-charge.
S&F GI tubing light grade 80mm bore, ISI marked, for cable protection, road crossing all a specified and directed.
S&F 1100 volts grade heavy duty flat twin core cable PVC insulated with stranded aluminium conductor of size 6 sqmm and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension GI wire from OH conductor to building incl dismentling taking down unserviceable one all as specified and directed.
All as per item No. 117.00 here-in-before but 10 Sqmm complete all as specified and directed.
All as per item No. 117.00 here-in-before but 16 Sqmm complete all as specified and directed.
M&L for painting of steel tubular pole with one coat of alumium paint incl cross arm, bracings, supports, nuts, bolts, of LT OH line from above copping to top of pole and marking with alternate Yellow and black paint strip 30 cm wide (5 Nos) with synthetic enamelled paint all as specified and directed.
M&L for trimming of branches of trees touching LT electric over head line and making clear about 3 mtr in radius by climbing up tree or by providing ladder, at a height 7 mtr and above and carrying and depositing where directed not exceeding 50 mtr.
S&F rigid PVC line spacer, suitable for 2 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade including taking down unsv one all as specified and directed.
S&F rigid PVC line spacer, suitable for 5 wire, made from high grade PVC material, distance between phase to phase 300mm, suitable for use with 1100 volts grade including taking down unsv one all as specified and directed.
Supply only greese for different component of electrical equipement as directed and specified by Engineer in charge.
S&F enclosure suitable for 4 POLE MCCB 100 A/250A with incomming and outgoing glands including taking out existing unserviceable Enclosure complete all as specified and as directed by Engineer-in-Charge.
Cable jointing kit for 1.1 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE insulated armoured aluminium conductor cable of size 120 sqmm to 185 sqmm including dismantling / taking down unserviceable jointing kit complete all as specified.
Cable jointing kit for 1.1 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE insulated armoured aluminium conductor cable of 50 to 95 sqmm size including dismantling / taking down unserviceable jointing kit complete all as specified.
Disconnecting defective voltage stabilizer indoor type servo controlled , oil cooled 3 phase of capacity 25 KVA draining out complete stabilizer oil & storing the same in suitable containers ( to be arranged by contractor ) opening the top cover and disconecting unsv servo motors , lifiting up core assembly carefully to check the condition of widing and core . Retanking the same after repair refilling the transformer oil after dehydration and filteration, including checking of leakage of transformer body and welding works required for making transformer body leak proof transportation of transformer to and from site to work shop and re-installation the same at any site complete all as specified and directed.
All as per item No. 128.00 here-in-before but 75 KVA voltage stabilizer complete all as specified and directed.
All as per item No. 128.00 here-in-before but 100 KVA voltage stabilizer complete all as specified and directed.
All as per item No. 128.00 here-in-before but 250 KVA voltage stabilizer complete all as specified and directed.
M&L for replacement of burnt /defective stabilizer copper coil with new one made out of super enamelled heavy duty copper wires of size matching to the existing one including varnishing, drying and insulating material in transformer complete all as specified and directed.
S&F in repair single phase AC servo motor(as per sample) suitable for voltage stabilizer of cap upto 250 KVA Complete all as specified and directed.
Filtration / dehydration of transformer oil in situ till dielectric strength of min 40 KV is achieved, Servo voltage stablizer, capacity 25 KVA to300 KVA indoor / outdoor type, installed at various electric sub stations / pump houses at Kasauli and Dagshai AOR of AGE E/M Kasauli complete all as specified.
Topping up / replacement of transformer oil with new transformer oil suitable for working voltage 430 volts grade including necessary dehydration to achieve dielectric strength min 60 KV at 2.5mm gap complete all as specified. Notes for serial item No 134.00 & 135.00 :- (a) New transformer oil shall be bought in company sealed IS marked container with test certificate. (b) Filtration / dehydration of transformer oil shall be carried out at the location where transformer is installed under the AOR of AGE E/M Kasauli and Dagshai and necessary filteration / dehydration plant having pressure gauge, hour meter, temperature gauge shall be brought to site by contractor including electric supply arrangement to run the dehydration equipment and unit rate quoted shall deemed to include the cost of the same.
S&F fix in repair plug in control card (PCB) for 3 phase servo controlled voltage stabilizer of cap 250 KVA (As per Sample).
S&F fix in repair plug in control card (PCB) for 3 phase servo controlled voltage stabilizer of cap 75 KVA (As per Sample).
M&L for repairing servicing of APFC panel board of Cap 50 KVAR by replacing tha all defective components with new components , re wiring , cleaning , testing, reconnecting , reinstalling and commissioning the APFC panel board complete all as directed by Engineer-in-charge. Note : -(i) Supply of cables, wires & other minor spare parts etc. will deemed to be included in the quoted rate.
M&L for repairing servicing of APFC panel board of Cap 100 KVAR by replacing tha all defective components with new components , re wiring , cleaning , testing, reconnecting , reinstalling and commissioning the APFC panel board complete all as directed by Engineer-in-charge. Note : -(i) Supply of cables, wires & other minor spare parts etc. will deemed to be included in the quoted rate.
Dismantling and Supply , install, connect, test and commission , 3 phase, heavy duty, explosion proof, self healing capacitor cylindrical type confirming to IS 13340 of following ratings :-
1 KVAr heavy duty
2 KVAr heavy duty
3 KVAr heavy duty
4 KVAr heavy duty
5 KVAr heavy duty
10 KVAr heavy duty
15 KVAr heavy duty
20 KVAr heavy duty
Supply and fix the following switch gear/components in various APFC Panels installed at Kasauli & Dsub station /pump houses.
MCCB 16A TP, 25 KA
MCCB 25 A , 25 KA
S&F LED Street light fitting 45Watt new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 road luminaire with high power LEDs as light source and electronic driver as specified and directed.
S&F Security light Bracket made out of galvanised steel light grade pipe of 40mm dia 1.2 mtr long bend to an angle of 120 degree with 02 Nos mild steel clamp 50mm x 50mm and 04 sets of nuts, bolts and washers painting with two coats of synthetic enamel paint over a coat of red oxide primer incl dismentling taking down unsv complete all as specified and directed.
Supply and fixing LT feeder piller broken doors of standard sizes at different places with proper locking arrangement( Tower bolts 2 Nos), welding works including paintings etc as specfied and directed.
Supply and fixing cable tray of size 6" in width of heavy grade suitable for LT cable at wall including fixture/screw and other connecting fixture etc as specifed and directed.
S&F Street light junction box of size 200mm x 140mm x 95mm outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable/wire complete comprising with the followings incl dismentling taking down unsv complete all as specified and directed. :- (a) Bus bar with two aluminium strips, 63 Amps capacity insulated with insulators, including colour coding, including PVC cable of suitable size from bus bar to MCB (b) MCB SPN 5 to 30 Amps - 01 No (c) Clamps made out of 25mm x 3mm flat iron duly weldedwith nuts & bolts complete all as specified and directed.
Amount of credit of Rs. 90743.00 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
Vishal Builder
Varindera And Varindera Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .