Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC PLOT NO RZ B 1 59 KH NO 534 535 BLOCK B 1 NEW ROHANPURA PP NO 1416 NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹29.2 L+₹35,984.60 (1.25%)Rejected-Finance RZG 205 RZG STREET NO 9 PALAM COLONY RAJ NAGAR PART 2 BAGDOLA SOUTH WEST DELHI DELHI 110077 | SOUTH WEST DELHI | DELHI | 110077 | L2 | Rejected-Finance Being not Lowest | |
| 3 | L3₹30.9 L+₹2.0 L (7.08%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L3 | Rejected-Finance Being not Lowest | |
| 4 | L4₹39.6 L+₹10.7 L (37.2%)Rejected-Finance | L4 | Rejected-Finance Being not Lowest | |
| 5 | Rejected-Technical NOT AVAILABLE | - | Rejected-Technical Not enlisted with requisite category as per NIT |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
9 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Jiagar Trivedi, SM
HQ CWE (AF) Gurgaon, Old Palam Road, Delhi Cantt-10
CWE/GGN/GT-12/2022-23 PROVN OF ROAD AT SITE N-1 OF AIR FORCE STATION RAJOKARI
2022_MES_545081_1
CWE/GGN/GT-12/2022-23
Open Tender
Civil Works - Roads
Item Rate
150 days
AF Stn Rajokari
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Gurgaon
₹66,000
Yes
28 Oct 2022
12 Aug 2022
17 Sept 2022
12 Aug 2022
9 Sept 2022
27 Aug 2022
12 Aug 2022 - 26 Aug 2022
Amount
Surface excavation in any type of soil n exc 30 cm deep and averaging 15 cm deep and getting out including cutting to required gradient and camber as for formation of road complete all as specified and directed.
Removing excavated material n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
M&L for 150 mm thick (spread thickness) Soling (or sub base) with broken boulders or quarried stone of grading 2, inter stices filled, surface formed and rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed.
M&L for 150 mm thick (compacted thickness) in ltwo layers each 75 mm thick WBM compacted with coarse aggregates granite/basalt of grading 2 (63 to 40 mm size), spread, rolled and consolidated to gradient and camber required to with 8 to 12 tonne power roller complete all as specified and directed.
M&L for preparing unsurfaced water bound macadam by brushing with wire brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc and applying evenly priming/tack coat with paving bitumen of VG-10 at 10 Kg per 10 Sqm complete all as specified and directed.
M&L bituminous premixed semi dense bituminous concrete 40 mm consolidated thickness using paving bitumen (VG-30) 5.5% binder content and filler by weight of total mix as per design mix, spread by means of self propelled mechanically spreader/paver, rolled and compacted to required camber and gradient complete , by using mechanically power road roller 8 to 12 tonne capacity complete all as specified and directed. NOTE: Design mix to be carried out as per job mix formula for adjustment of bitumen and filler content complete all as specified.
M&L for continuos brick edging, with width equal to the width of the brick, laid dry or end vertically with burnt clay bricks of sub class 'B' old sized including necessary excavation as required complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 4 core x 10 Sq mm. complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 4 core x 6 Sq mm. complete all as specified and as directed.
Supplying, transporting to site, erecting and fixing in vertical position, steel tubular swaged and welded poles straight in length of overall height 8.5 meters, type 410 SP 31, IS-2713 marked, with mild steel base plate (fillet welded to poles), pole cap/finial taper plug, bolts, nuts, washers etc, including 1.2 mtrs long GI pipe medium grade 32 mm bore bracket fixed on pole by MS clamps, nuts bolts and washers and painting of pole on the outside with two coats of aluminium paint over a coat of red oxide primer on exposed surfaces and black bituminous paint on steel surface embedded in concrete and painting 03 Nos band/strips with yellow and black synthetic enamel paint (30 cm wide each) at a distance of 30 cm from plinth block and numbering of poles, complete all as specified and directed ( excavation & earth work, PCC and copping to be measured and paid seperately)
S&F submain wiring with unsheathed multi-stranded copper conductor cable 1100 volts grade drawn through in and including PVC conduit medium grade of not less than 25mm dia with conduit accessories including clamping of pvc conduit with suitable MS clamp on pole for two runs of 1.5 Sqmm and one run of 1.5 Sqmm for earth wire PVC insulated copper conductor for earth continuity wire complete all as specified and as directed.
Supply and fixing street/security lighting luminaire with 70 watt High power LED and extendable upto 75high power led, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system equivalent of 90 watt all as specified and directed, Make : Philips Cat No BRP 320/1 *24 HP LED fixture, or equivalent in surya Genxt 70w /bajaj Cat No BRTFG 70W /Havells Cat No Endura Omniplus 70w LED etc NOTES_( a ) Driver And Luminaires Shall Be Of Same Make. (b) LM-79 report for fixture shall be produced by contractor (c ) CRI of luminire should be more than 80 (d) THD of luminire shall be less than 20 % (e) PF of luminire shall be more than 0.9 (f) system efficacy shall not be less than 90 lumen / watt.
Supply & install testing , commissioning of Feeder piller box of size 40 cm X 40 Cm x 30 Cm 415 Volts, 50 Hz , 3-phase, 4 wire supply floor mounted , factory assembled, outdoor type weather and vermin proof (Protection Class IP-65) made out of 40m x 40mm x 6mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet with front hinged opening, rubber lining, locking arrangement ,powder coated externally and internally after seven tanks treatment and lifting channel, fully compartmentalized design comple Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed capacity 200 Amps with colour coding complete all as specified and consisting of the following : - (a) Incoming – MCB TPN of capacity 63 Amps -01 No. (b) Outgoing- MCB TPN of capacity 40 Amps – 03 no. (d) Timer switch electronic type -01 No (e) Panel wiring with copper flexible cable PVC Insulated 1100 Volts grade complete cable connections of incoming/outgoing cable, auto/manual function switch, and testing on load after completion of work all as specified. (f) Necessary excavation and earth work in any type of soil, for foundation in PCC 1:3:6 type C-2 using 40mm Graded crushed stone aggregated as in foundation and bricks work in cement and sand mortar 1:4 and 15mm thick Plaster in CM 1:6 on top & all around the brick pillars up to 1500 mm below ground level and brick pillars 0.5 meter high above ground level for mounting the Feeder piller box.
M&L for bracket 2.5 mtr long for steet light fitting made of 40 mm bore light grade GI tube bent to shape required fixed with and including MS flat iron clamp bolts nuts washer duly painting the bracket with two coats of aluminum paint over a coat of zink chrome primer complete including fixing in wall and connecting up the ilght fitting etc
S& F weather proof steet light junction box of size 150 x 150 x 70 mm Including MCB SP 6 Amps and connecting terminals 4 way and fixing with steet light poles using necessry ms clamp nuts bolts washers lugs for incoming and out going cables grand for cable etc of suitable size complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep in depth in hard/ dense soil and getting out
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
M&L for sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable all as specified & directed by Engr-in-Charge.
Supply and lay common burnt bricks sub class 'B' brick best quality locally available for LT cable protection
S&F tubing light grade of size 40 mm bore laid in trench/under road/crossing or fixed to wall pole,for protection of underground cable Complete all as specified and directed.
S & F volumetric and nominal mix concretes, with grade &mix of cement concrete,Portland cement concrete with Graded coarse aggregate type B1 20mm graded (PCC 1:2:4 ) Complete all as specified and directed.
S & F volumetric and nominal mix concretes, with grade & mix of cement concrete Portland cement concrete with Graded coarse aggregate type D2,40mm graded (PCC 1:4:8 ) in foundations, filling and mass concrete Complete all as specified and directed.
M/S LADPURIA ENTERPRISES
akhil enterprises
Hindustan Co.Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .