| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC SINCE LOWEST BIDDER | |
| 2 | L2₹45.2 L+₹7.4 L (19.6%)Rejected-Finance | L2 | Rejected-Finance SINCE NOT L1 BIDDER | |
| 3 | Rejected-Technical | - | Rejected-Technical Not recommended for opening of financial bid. Since remarks given in WLR of HQ CEWC QE Sep 2022 is No |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
16 Jan 2023, 6:00 pmClosed
CWE AMRITSAR CANTT
HQ CWE AMRITSAR OLD CANTT
REPAIR/REPLACEMENT/MAINTENANCE OF DISTRIBUTION TRANSFORMERS EARTHING VCB RELAY HT CABLES CALIBRATION TRANSFORMER DEHYDRATION ALLIED WORKS AT 66 KV GRID STATION AND ALL CONNECTED ITEMS OF EXTERNAL ELECTRIC SUPPLY AT OLD AMRITSAR CANTT UNDER GE AMRITSA
2022_MES_552367_2
CWE/ASR-33/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE ASR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE AMRITSAR
₹80,000
Yes
30 Mar 2023
21 Dec 2022
18 Jan 2023
21 Dec 2022
16 Jan 2023
4 Jan 2023
Amount
Supply, laying, testing & commissioning of HT 11 KV (Earthed) XLPE insulated screened PVC bedded, electric power cable (heavy duty) with aluminium conductor 11000 volts grade,circular screened with extruded semi conducting compound in combination with copper tape , inner sheath of PVC tape galvanized steel strip flat , around and overall PVC sheathed, armoured conforming to IS 7098 Part II, 1985 amended upto date, of size 3 core 120 Sqmm, ISI marked, laid in trenches or passing through pipes/ducts including taking down old cable of any size all as specified and as directed. Make : Polycab/Glostar/Incab and all other equivalent makes as specified in Appendix"B" list of makes. Note :- 1. Excavation and earthwork , sand cushioning , GI pipe, cable protection will be measured and paid for separately 2. Cable shall be tested at high voltage test before & after laying. 3. No straight through joint will be permitted inside pipe or duct. 4. Cost of straight through if any deemed to be included in cost of cable.
Material & labour for copper winding wire of any size/description suitable for step down power transformer of any capacity, including winding of coils (HT/LT) as per the manufacturers design & specification to obtain rated KVA complete all as specified.
Supply & lay in replacement DWC pipe 100 mm bore SN4 grade for laying of HT cables etc complete with all accessores all as specified and directed
S&F in replacement steel tubing GI light grade of size 100mm bore dia for cable protection passing under road / floor or for fixing to poles all as specified and as directed. Make: Swastik/Tata/Jindal and all other equivalent makes as specified in Appendix"B" list of makes.
M&L for replacement of cable jointing kit for 11 KV grade cable for straight through heat shrinkable joint suitable for XLPE armoured aluminium conductor cable of size 3 core 120 to 185 Sqmm all as specified and directed. Make: Dension/ M Seal/Siemens and all other equivalent makes as specified in Appendix"B" list of makes.
M&L for replacement of end termination cable jointing kit for 11 KV grade cable heat shrinkable joint, out door suitable for XLPE armoured aluminium conductor cable complete with jointing materials and accessories suitable for 3 core 120 to 185 Sqmm all as specified and directed. Make: Dension,M Seal/Siemens and all other equivalent makes as specified in Appendix"B" list of makes.
M & L for replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps of size 25x4mm, bolts and nuts of approved size for HT of size 25x20cm complete all as specified and as directed.
S&F in replacement of HT 66 KV out door non-linear type lightening arrestor with mountings, accessories complete fixed on cross arms of two pole structure / GI flat strip and connect with same size of ACSR conductor encashed in PVC alkaline pipe with all fittings connected to earth strip with nuts, bolts and washers, transmission class having discharge current capacity of 10 KA and voltage heavy duty station class 66 KV/75 KV Maximum, max continuous operating voltage 66 KV, rated short circuit current 20 KA including taking down old lightning arrestor all as specified and as directed including dismantling existing one all as specified and as directed.
M&L for renewal of earthing of poles/system with galvanised earth plate 60cm x 60 cm x 6.30 mm thick electrode of size and 32 x 6 mm GI strip buried vertically in ground not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level and connected to copper strip dia by means of nuts, bolts and washers and encased in and including 15mm dia GI medium grade pipe upto 2.4 mtr height form ground level fixed by MS flat iron clamp 40mm x 5mm with nut, bolt and washers, GI strip fixed to base along pole and connected to over head line for providing earthing to HT pole/feeder AB switch LA complete with charcoal dust, salt packed around plate 150 mm thick including watering GI pipe, medium grade 40 mm dia with blanking cap 1.5 mtr long fixed to funnel with wiremesh complete with PCC chamber and RCC chamber over all as per Electrical Plate No 5 of SSR Part I - 2009 incl excavation and earth work in any type of starta and testing on competion. (Note: Any length of GI strip and 15 mm dia GI medium grade pipe shall be provided as per actual requirement at site).
All as per Srl item No 10 above, but with copper plate 60cmx60cm x 3.15mm thick electrode and 20x3mm copper strip as earthing lead encased in 25 mm bore light grade GI pipe complete all as specified and as directed.
Supply and spreading in electrical outdoor installation yard, stone aggregate of size 40 mm at 11KV substations / Near DP structures after through cleaning, anti grass treatment etc complete all as specified and as directed.
All as per Srl item No 11 above, but aggregate of size 20mm.
Labour only for repairing/ servicing calibrating / testing and commissioning complete as mentioned in maintanance and operation manual of O.E.M of 11 KV HT vacum circuit breaker (indoor) TP - 800/400 Amp capacity vertical / Horizontal isolation and Horizontal draw out type including calibiration and testing of relay, and making 100% serviceable for remote / manual operation all as specified and directed. Make : Kirlosker, Crompton Greaves, and Seimens and all other equivalent makes as specified in Appendix"B". Note:- (i) CT & PT Testing , calibiration and replacing measured and paid separately. (ii)Spare Parts required will be measured and paid separately under relevant items of work.
Supply only spring charging motor gear box assembly 230 VAC as per sample complete all as specified and as directed. Make - Kirlosker, Crompton, Seimens and all other equivalent makes as specified in Appendix "B" list of makes.
Supply only Gear Assembly for VCB as per sample complete all as specified and as directed. Make - CG/Kirloskarand all other equivalent makes as specified in Appendix "B" list of makes.
Supply only small gear assembly as per sample complete all as specified and as directed. Make- CG/Kirloskar all other equivalent makes as specified in Appendix "B" list of makes.
Supply only micro switch as per sample complete all as specified and as directed. Make -Kirlosker/ CG all other equivalent makes as specified in Appendix "B" list of makes.
Supply only motor control of limit switch as per sample complete all as specified and as directed. Make -Kirlosker/ CG all other equivalent makes as specified in Appendix "B" list of makes.
Supply only closing coil 30VDC assembly as per sample complete all as specified and as directed. Make -Kirlosker/ CG all other equivalent makes as specified in Appendix "B" list of makes.
Supply in replacement 11 KV PT fuse as per sample complete all as specified and as directed. Make -Kirlosker/ CGall other equivalent makes as specified in Appendix "B" list of makes.
Supply only control fuse links NS type 2A, 4A, 6A,10A,16A as per sample (20 Nos each) complete all as specified and as directed.
Supply only Trip circuit healthy push button as per sample complete all as specified and as directed.
Supply only TNCs switch as per sample as per sample complete all as specified and as directed.
Supply only Shunt trip coil 30VDC assembly as per sample complete all as specified and as directed.
Supply only Bottom contact support insulator as per sample complete all as specified and as directed.
Supply installation testing and commissioing of Current Transformer of VCBs 11 KV all as per sample and all as specified and directed.
Supply installation testing and commissioing of potential Transformer of VCBs 11 KV all as per sample and all as specified and directed
M & L for resin cast type twin secondary current transformer of ratio 200-100/5-5A Class – I SP – 10 for protection and metering , capacity 15VA/15VA burden for protection and metering to conform IS – 2705 of 1992 complete all as directed.
Material and labour for servicing and testing of outdoor type three phase SF6 Circuit breaker for carrying out Contact Resistance Measurement, Circuit breaker Trip time, insulation resistance and coil resistance test complete at site and submission of report. Note: The cost of T&P and other expenses such as boarding and lodging of testing team etc are included in the unit quoted rates. The unit quoted rates included general servicing, greasing of mechanical gears, gas recharging of the breaker etc at site complete all as specified and directed by Engineer-in-Charge.
Material and labour for servicing of Control and Relay panel (C&R panel) of transformer including testing of differential relay , IDMT relays and other auxiliary relays of transformer protection with secondary injection test kit complete at site and submission of report. Note: The cost of T&P and other expenses such as boarding and lodging of testing team etc are included in the quoted rates. The quoted rates included general servicing, checking of wiring, replacement of minor parts complete all as specified and directed by Engineer-in-Charge.
Material and labour for testing of 66kV outdoor type CT and carrying out tests i.e IR test, polarity test, knee voltage test, ratio test with primary injection kit. Note: The cost of T&P and other expenses such as boarding and lodging of testing team etc are included in the quoted rates. The quoted rates included general servicing, checking of wiring, replacement of minor parts complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing & testing 2.5 Sqmm 4 core PVC insulated, armoured electric cable with flexible stranded copper conductor, 1100 volts grade complete including taking down old unserviceable cable any type and size all as specified and directed.
All as per Srl Item No 32.00 here-in-before but 2.5 Sqmm 10 core
M & L for Opening up the top cover of the transformer by taking out the transformer oil in a separate container after disconnecting / taking out the HT/LT side electric connections from both the primary & secondary side of the transformer of any type / description (indoor / outdoor type ) installed on floor/pole for carrying out necessary repair / rewinding to HT/LT side or any other repair as required after shifting the transformer to contractor's work shop including taking out complete core assembly, Megger the winding for identifying the faulty / defective winding, seggregating the defective winding portion/taking out, cleaning the laminated core rewinding with appropriate gauge winding wire of existing description for transformer of capacity 50 to 160 KVA including assembling & testing on completion & installation the same at the site all as specified and directed.(Note : (i) Copper Winding of coil and spares required as per repair shall be measured and paid separately under respective item.(ii) The transportation charges and taking down/taking up of transformer are inclusive in the quoted rates.(iii) The cost for the dehydration of transformer oil if reqd shall be measured & paid separately.(iv) The cost of insulation material such as paper, cotton tape , latheroid sheet , cast sheet etc are inclusive in the quoted rate.)
All as per Srl Item No 34.00 here-in-before but capacity 200 to 500 KVA. (Note- For item No. 34 and 35 - i) The transformeres will be opened in presence of BOO and wt of copper coils damaged and new to be fixed will be done in presence of Board of officeres. ii) All testing of transformer after repairs will be certified by BOO before despatch from the factory)(iii) Cost of all testing etc is deemed to be included in quoted rate & nothing extra shall be paid to Contractor.
Dehydration and filtering the transformer oil with dehydration machine to achieve dielectric strength of the oil to 60 KV at 2.5 mm gap complete all as specified and directed. Note:- Dehydration machine and other necessary equipments required shall be arranged by the contractor and quoted rates shall be inclusive of this aspect. Record of test results after dehydration shall be submitted to the Engineer-in-Charge
Dehydration and filtering the transformer oil with dehydration machine to achieve dielectric strength of the oil to 40 KV at 2.5 mm gap complete all as specified and directed .Note:- Dehydration machine and other necessary equipments required shall be arranged by the contractor and quoted rates shall be inclusive of this aspect. Record of test results after dehydration shall be submitted to the Engineer-in-Charge
Supply and filling for topping up transformer oil in the transformer after dehydration with dehydration machine to achieve dielectric strength of oil to 60 KV at 2.5mm gap complete all as specified.
Supply and filling for topping up transformer oil in the transformer after dehydration with dehydration machine to achiene dielectric strength of oil to 40 KV at 2.5mm gap complete all as specified.
Supply only glyphosate 41% SL Glykol Herbicide to remove vegatation from E/M Installations complete all as specified and directed by Engr-in-Charge
Supply only insulating mat as per IS-15652, 2.5 mm thick suitable for 11 KV supply complete all as specified and directed.
Supply and fix in repair digital voltmeter suitable for HT VCB Panel 66 KV as per sample complete all as specified and directed.
Supply and fix in repair digital ammeter suitable for HT VCB Panel 66 KV, 0-100 Amp as per sample complete all as specified and directed.
Supply and fix LED Indicator lamps as per sample complete all as specified and directed.
Supply and fix in replacement thermostat of VCB as per sample complete all specified and directed.
Supply and fix in replacement space heater of VCB as per sample complete all as specified and directed.
Supply only Battery 2 Volt , 110 AH lead acid as per sample complete all specified and directed. Make:- Exide / Amar raja / Amron and all other specifed makes in Appendix"B" list of makes.
Supply and fix in repair pole mounted with MS brackets box for housing the electrical terminals / control of VCB's out door type made out of CRCA sheet 3.15 mm thick of size 60cm (height) x 45 cm (width) and 30 cm depth duly powder coated complete with locking arrangement all as directed by E-in-Charge
M & L for HT cable entry sealing in HT 11 Panel with MS sheet 2 mm thick cut as per site requirement and POP all as directd by E-in-Chrage
Supply and fix cable route indicators with PCC 1:2:4 , type B1 in replcement for HT 11 KV supply all as specified and dircted by E-in-Charge duly engraved with HT cable and having Angle iron support of size 40x40x4 mm and 60 cm long duly embeded in PCC complete all as specified and directed.
Labour only for connecting existing earth strips with GI earth strips with GI earth strip of size 40x6 complete with welding as and where directed. Note : GI earth strip of size 40x6 mm will be measured and paid separately.
Supply only for connecting GI earth strip of size 40x6mm complete all as specified and directed.
Supply only for connecting GI earth strip of size 32x6mm complete all as specified and directed.
Excavation in trenches, getting out in soft/loose soil not exceeding 1.5m deep and not exc 1.5m wide for water pipes, cable etc any size at places complete all as specified and directed.
Returning filing in including spreading levelling, watering & well ramming in layers not exceeding 25 Cm thick all as specified and directed.
Removing of surplus soil to a distance not exceeding 50 mtr complete all as specified and deposited where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
M&L for inspection and testing of HT 11 KV capacitor bank of make Schneider capacity 1200 KVAR, complete including necessary testing of capacitors, reactors / detuned filter, IR test, continuit for its proper functioning on laod including its APFC relay all as specified and directed to the entire satisfaction of E-in-Charge and switching ON the HT APFC Panel and putting into ckt and checking for its proper functioning on laod for 24 hrs. (The rate quoted shall be inclusive of labour for replacement of capacitor / detuned filter / HRC fuses only.)
Supply only capacitor of capacity 300 KVAR suitable for 11 KV 50 Hz AC supply all as per sample complete all as specified and directed.
Supply only reactor / detuned filter suitable for 300 KVAR capacitor of 11 KV 50 Hz AC supply all as per sample complete all as specified and directed.
Supply only High voltage HRC fuse suitable for 300 KVAR capacitor of 11 KV 50 Hz AC supply all as per sample complete all as specified and directed.
Supply and fixing LT side brass stud with nuts. Bolts and washers for trasnformer of capacity 50 to 200 kVA complete all as specified and directed
Supply and fixing LT side brass stud with nuts. Bolts and washers for trasnformer of capacity 200 to 500 kVA complete all as specified and directed
Supply and fixing HT side brass stud with nuts. Bolts and washers for trasnformer of capacity 50 to 200 kVA complete all as specified and directed
Supply and fixing HT side brass stud with nuts. Bolts and washers for trasnformer of capacity 200 to 500 kVA complete all as specified and directed
Supply and filling silica gel in different capacity of transformers breathers complete all as specified
Material & labour for Air breather assy complete with fresh blue colour silcagel suitable for indoor/outdoor type transformer capacity 50 to 160 KVA complete all as specified.
All as per Srl Item No 66 here-in-before but capacity 200 to 500 KVA.
Suppy and fix in replacement O/C and E/F relay as per sample suitable for 630 Amp 11000 Volts VCB as per sample including provision for fixing in existing panel by cutting/welding work all as specified and directed Make schenider (model Micom) or equivalent in :Alstom/ ABB Note: The CT connection may be of /5A or /1A as required at site.
Shifting of transformer of capacity 50 KVA to 500 kVA from one place to other place on two/four pole/plinth in old Amritsar cantt area/GG fort including removing and refixing of HT/LT connections complete all as specified and directed (All T&P, hydra crane etc required for the job should be provided by contractor, the quoted rate of this item deemed to included )
Material and labour for fixing aluminium strip 40x10mm, including stainless steel bolts, washers, cutting and making hole as per the LT/HT stud of the transformer of rating 50-500kVA complete all as specified and directed by Engineer-in-charge
Suppy and fixing Closing coil suitable for 630 Amp 11000 Volts VCB as per sample complete all as specified and directed. Make Kirloskar Model M-500
Suppy and fixing Tripping coil suitable for 630 Amp 11000 Volts VCB as per sample and specified and directed.Make Kirloskar Model M-500
Suppy and fixing FRP Vaccum Bottle Support suitable for 630 Amp 11000 Volts VCB as per sample complete all as specified and directed. Make :Kirloskar Model No.M-500
Supply, fixing, connecting and testing in replacement of U/S meters flush type 96x96 mm digital type Multifunction meter with LCD display including cutting/welding work all as directed
All as per item No. 74 above but Digital Volt meter 11 KV, suitable for 110/240 volt AC supply suitable for showing three phase values
All as per item No. 74 above but Digital Amp meter for 11 KV VCB 0-200 Amp suitable for 110/240 volt AC supply suitable for showing three phase values.
Electronic Buzzer with input voltage of 230 V AC and output noise level of 90-120 db (decibels) suitable for Control and Relay panel and VCB panel as per existing sample complete all as specified and directed .
Material and labour for recording earth resistance values of distribution transformer/GOD/LA 11kV/66kV any type strip/wire of any capacity and submitted the record to the Engineer-in-charge complete all as specified and directed. Note: The T&P for the work to be arranged by the contractor.
Material and labour for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip 25 X 4 mm size by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate), GI protection pipe light grade 40 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
Material & labour for preparing old painted surface of distribution / power transformer outdoor / indoor / pole mounted of capacity 100 to 500 KVA by cleaning, removing the old paint by scratching with wire brush etc and applying with spray machine two coats of synthetic enamel paint of grey colour on external surfaces of the transformer and writing of letter HT / LT or HV / LV and SM / MES Nos including disconnecting and making electric connections complete all as specified and directed. Note: (i) The compressure / spray machine and other required necessary equipments shall be arranged by the contractor and quoted rates shall be inclusive of this aspect.
Material and labour for filling fine river sand in the trench below power transformer and trencehes of HT VCB including levelling and spreading complete all as specified and directed by engineer in charge
Supply and fixing in replacement of pin type insulator polymer material with capacity of 11kV and GI pin, including GI nuts,bolts and washers, binding conductor and insulator with GI wire and dismantling old insulator complete all as specified and directed.
Supply and fixing in replacement of Disc type insulator polymer material with capacity of 11kV and GI pin, including GI nuts,bolts and washers, binding conductor and insulator with GI wire and dismantling old insulator complete all as specified and directed.
Supply, installation, connecting, and testing of 11 KV single phase indoor resin cast CT of ratio 300/150/5-5A suitable for VCB as per existing type and make including taking down old unserviceable CT all as specified and directed.Make : Instrans/CG/Schneider
All as per Srl Item No 84.00 here-in-before but CT ratio 100/50/5-5A
Supply, laying, jointing and testing HT XLPE cable cross section area 95 Sqmm, 3 core, 11000 V screened earthed, PVC 'E' grade insulated bedded, galvanised steel (heavy duty ) strip or wire armoured with alluminium conductor 11 KV pressure earthed system conforming to IS 7098 (Part-1 ) 1977 and Part-II of 1985 laid in pipes /ducts/ trenches,under floor and roads or fixed to wall etc incl taking out old unsv cable any type complete all as specified and directed.Make Havells/Gloster/ KEI
M&L outdoor type cable end termination kit, heat shrinkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable size 50 to 95 sqmm 3 core including testing after jointing complete all as specified and directed. ( Make- M Seal/ Raychem / 3M)
M&L outdoor type cable end termination kit, heat shrinkable jointing material and accessary complete suitable for 11 KV HT XLPE underground cable size 240 to 300 sqmm 3 core including testing after jointing complete all as specified and directed.
M&L cable straight through joint box type suitable for 11 KV U/G XLPE screened PVC bedded GI Strip or wire armoured cable size 50 to 95 Sqmm 3 core heat shrinkable, , termination kit jointing material connected to electrical system with and including cable pieces of suitable size length, and the tap vice type compelete all as specified and directed.
Supply only HT jumper for existing two/four pole structure of transformer etc using 95 Sqmm single core aluminium cable conductor , including PG clamp nut, bolts, thimbles and washers etc as required at site all as directed by Engr-in-Charge.
Supply only HT fuses for existing two/four pole structure of transformer etc of current rating 2.5 to 25 Amps, suitable for 11 KV complete all as specified by engineer in charge
Supply, installation, commissioning and testing of switch Air break, Gang operated with 12 insulator polymer type type switch Triple pole mechanicaly operated, mounted on insulator and steel frame, with mechanism worked from ground level, for current rating 400 Amp operating Voltage 11 KV out door type vertical mounted type complete with locking arrengement,assembly with fuse mount carrier and fuse element of required capacity and isolate suitable for 11 KV including necessary electric connection and 11 KV fuse (drop out type) of capacity as per site requirement and as specified by Engr Incharge , complete with DO fuses assembly with channel and one No. operating Rod of 25 mm dia bore grade GI pipe of suitable length worked out from ground level and handle complete with lock and two Nos keys incl flat iron clamp 50mm x 6mm MS channel of suitable size & length for fixing GOD incl nut,bolt, washers including taking down existing set all as directed by Engineer-in-charge.Make Rashtriya/Reychem/Jaipuria
Shifting of 11 KV VCB of any capacity any make from one sub stn to other sub stn (with in 5 KM) in old Amritsar cantt area including removing and refixing of HT connections complete all as specified and directed (All T&P, hydra crane etc required for the job should be provided by contractor, the quoted rate of this item deemed to included )
M&L for prunning and removing of tree branches touching to electric over head lines wild growth around LT /HT over head lines and around pole and stay complete to make clear span of 2 Mtr of tree both side of the OH line with JCB, Cutter and all tools, plants etc all as directed by Engineer-in-Charge. Note : (i) Distance between pole to pole will be measured and paid. (ii) Contractor has to take upmost care to avoid damage to existing lines/structures if Any breakdown of line caused during punning shall be made good without any extra cost. (ii) Prunning of tree to be done twice a year (before & after rainy season) (iii) The contractor has to ensure the proper safety of the tradesmans to avoid any mishappening. If any mishappening occures the contractor will be solely responsible for it.
M & L for checking of HT UG 11 KV XLPE faulty cable with HT UG cable fault locating testing machine, rectifing the fault, putting the jointing kit and charging the cable as all as specified and directed. Approx length 500 RM for each Job. (The rate for excavation, removing of old cable, laying after repairs is demmed to be included in the rate quoted by the contractor).
M & L for testing and repairs to of APFC panel of any capacity for its functioing incl testing of capacitors contactors etc and repalcement of any item found defective in the panel complete all as specied and directed ( Note - The Items to be replaced will be measured and paid separately)
Supply only APFC realy 4/6/8 stage make Beluk or as per sample complete
Supply only contactor capacitor duty 3 phase 415V, 50 Hz, suitable for capacitor 3/5 KVAR
Supply only contactor capacitor duty 3 phase 415V, 50 Hz, suitable for capacitor 10/12.5 KVAR
Supply only contactor capacitor duty 3 phase 415V, 50 Hz, suitable for capacitor 15 KVAR
Supply only contactor capacitor duty 3 phase 415V, 50 Hz, suitable for capacitor 20 KVAR
Supply only contactor capacitor duty 3 phase 415V, 50 Hz, suitable for capacitor 25 KVAR
Supply only Capacitor bank MPP super heavy duty 5 KVAR, 440V,50 Hz, AC supply as per sample
Supply only Capacitor bank Super heavy duty MPP 10 KVAR, 440V,50 Hz, AC supply as per sample
Supply only Capacitor bank Super heavy duty MPP 15 KVAR, 440V,50 Hz, AC supply as per sample
Supply only Capacitor bank super heavy duty MPP 20 KVAR, 440V,50 Hz, AC supply as per sample
Supply only Capacitor bank super heavy duty MPP 25 KVAR, 440V,50 Hz, AC supply as per sample
Supply only CT 500/5 Amps all as per sample (for APFC panel )
Supply only CT 300/5 Amps all as per sample (for APFC panel )
Supply only copper wire 2.5 Sqmm FR 1100 V grade (for APFC panel )
Supply only Hot air blower make Bosch 620 watts Blue and black Model GBL 620 as per sample
Supply only Hand gloves working potential 11 KV, ISI marked Make- Jyot/Vidyut/Crystal
Supply and fix in replacement insulator suitable for 11 KV, VCB all as per sample
M & L for Aluminum conductor for making HT BUS on 4/6 pole structre all as directed
B S TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .