| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC 23 A MORAR ENCLAVE GOLA KA MANDIR MORAR GWALIOR MP 474005 | GWALIOR | GWALIOR | MP | 474005 | L1 | Accepted-AOC Being a lowest | |
| 2 | L2₹14.3 L+₹60,331 (4.41%)Rejected-Finance G 124 FLAT NO 4 DILSHAD COLONY DELHI 110095 | SHAHDARA | DELHI | 110095 | L2 | Rejected-Finance Not a lowest tender | |
| 3 | L3₹16.6 L+₹2.9 L (21.3%)Rejected-Finance 220 GANPATI ENCLAVE DABWALI ROAD BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Not a lowest tender | |
| 4 | L4₹22.6 L+₹8.9 L (65.2%)Rejected-Finance | L4 | Rejected-Finance Not a lowest tender | |
| 5 | L5₹22.7 L+₹9.0 L (65.9%)Rejected-Finance | L5 | Rejected-Finance Not a lowest tender |
Tender Value
₹16.5 L
EMD Value
₹33,000
Closing Date
25 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TA GWALIOR
GE AF TA GWALIOR 474020
PROVN OF CERTAIN SANCTIONED WORKS OF B/R AND E/M IN TECH AREA AT AF STN GWALIOR
2020_MES_401670_1
8900/1286/GWL/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF TA GWALIOR
As per tender documents
7 documents required · 7 mandatory
₹500
GE AF TA GWALIOR
₹33,000
Yes
15 Jan 2021
9 Dec 2020
28 Dec 2020
9 Dec 2020
25 Dec 2020
19 Dec 2020
60 days
Amount
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc), or insulation boards/slabs/blankets, any thickness any type including cover fillets, complete all as specified and directed.
S&F MS galvanised powder coated suspended false ceiling system with grid of size 605mm x 605mm, consisting of mild steel galvanised powder coated main runner of size 24mmx32mm and cross Tee of size 24mm x 27 mm and wall angle of size 22.2mmx22.2mm, suspended with 4 mm dia GI wire hanger at 1200 mm spacing, fixed with steel dash fasteners or from purlin of roofs with butterfly clips etc includding 12mm thick gypsum board ( Semiperforted) in ceiling fixed to GI snap grid frame work with hold screws, of any height upto 8.5m with adjustable cleat of J hook including making provision for housing light fitting, AC grils etc complete including fixing, re-fixing false ceiling lights, wastage T&P as per manufacturer's instructions and complete all as specified and directed by Engr-in-Charge.
S&F MS galvanised powder coated suspended false ceiling system with grid of size 605mm x 605mm, consisting of mild steel galvanised powder coated main runner of size 24mmx32mm and cross Tee of size 24mm x 27 mm and wall angle of size 22.2mmx22.2mm, suspended with 4 mm dia GI wire hanger at 1200 mm spacing, fixed with steel dash fasteners or from purlin of roofs with butterfly clips etc includding 12mm thick semi perforated gypsum board accoustic false ceiling with nrc fixed to GI snap grid frame work with hold screws, of any height upto 8.5m with adjustable cleat of J hook including making provision for housing light fitting, AC grils etc complete including fixing, re-fixing false ceiling lights, wastage T&P as per manufacturer's instructions and complete all as specified and directed by Engr-in-Charge.
M&L acoustic foam wall panelling using 50mm thick tiles of size 30cmx30cm or 60cmx60cm with NRC > or equal to 0.9 made of Acoustix polyurethene of approved colour density 40 Kg/cu'm fixed to walls using SR adhesive or spray adhesive complete all as specified and directed by Engr-in-Charge. .
M&L for preparation of new surfaces of gypsum board for false ceiling and applying two coats of oil emulsion distemper complete all as specified and directed.
Demolition of Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified by Engineer-in-charge.
Providing, cement concrete in lintels upto 1.5m clear span, cills, steps; copings, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating, as directed, type B0, 1:2:4 using 12.5 mm graded aggregate complete all as specified by Engineer-in-charge..
M&L for 15mm thick rendering on brick work or concrete surfaces of wall in CM 1:4 finished even and fair complete all as specified by Engineer-in-charge.
M&L two coats of exterior oil emulsion over a coat of primer on plaster surfaces including preparation of surfaces complete all as specified by Engineer-in-charge.
M&L for prepration of old surface and applying one coat of exterior oil emulsion, white or tinted, complete all as specified by Engineer-in-charge. MAKE : ASIAN/BERGER(LUXOL)
S&F Framed work such as grills, grating,etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings, framework of watertanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified by Engineer-in-charge.
M&L preparation of new steel surfaces and applying two coats of synthetic enamelled paint complete all as specified by Engineer-in-charge.
Rolled mild steel in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete - S & F - Fe 410 -W (Gde-E-250) quality-B complete all as specified by Engineer-in-charge.
S&F 1.6mm thick mild steel, plain, black sheet in hearths; covering to door shut ters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required as in rifle rack complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long - 11 to 15mm Diameter of neck complete all as specified and directed.
S&F 50mm dia MS roller/wheels and pintel, nut, bolts etc (Fe 290 gde E-165) complete all as specified and directed.
S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints as in rifle rack including necessary cutting and finishing complete all as specified and directed.
M&L preparation of new wooden surfaces and applying two coats of synthetic enamelled paint over a coat of pink primer complete all as specified and directed.
Taking down carefully of serviceable ceiling light fittings , ceiling fans and firedetectors and keeping at safe custody for the renovations complete complete all as specified and directed.
Taking down sub main wiring of cable size upto 6.0 Sqmm including conduit of any type and size complete and making goods disturbed surfaces with existing all as specified and as directed by the engineer-in-charge.
Taking down sub main wiring of cable size upto 4.0 Sqmm including conduit of any type and size complete and making goods disturbed surfaces with existing all as specified and as directed by the engineer-in-charge.
Taking down carefully of serviceable in door unit of split type Air conditioner of any make upto 2.0 Ton and keep at safe custody for reuse all as directed by engineer -in-charge..
Material and labour for point wiring with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor cable (FRLS) 1100 volts grade drawn through and including 20mm dia medium grade rigid non metalic PVC Surface conduit along with 1.5Sqmm continous PVC insulated unsheathed single core mult-stranded copper conductor cable (FRLS) for earth continuty wire connected to comman earth dolly/fitting ete and wiring to be terminated in pressed steel sunken boxes with laminated top sheet of 3 mm thick for housing of switchws, sockets, regulators etc including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed.
Supplying & fixing switch piano flush type, 5/6 Amps, single pole, one way, 230 volts AC circuit complete all as specified and directed. Make: Anchor/Cona/Havells
Supplying & fixing for ceiling rose surface bakelite 63.5 x 20 mm, three terminals, complete all as specified and directed. Make: Anchor/Cona/Havells
Refixing of ceiling fans complete with three core cable length 1.25mtrs and new down rod heavy duty mild steel length not less than 1.00 mtrs all as directed by Eng -in- charge.
Supply and fixing in 34W LED recess softline luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extruded diffuser giving glare free light and good aesthetic appeal. Fixture size 595x595x70mm complete with LED tube with driver and all accessories specified and directed by Engr -in- Charge. Make : Havells cat part No PLUTONEO2X2PLR34WLED840S/Surya Cat No- SLEFP36R 22/ CG Cat Part No -LCTLSN36- CDL.
M&L for sub main wiring with using two single core PVC insulated, unsheathed cable with multi stranded copper conductor (FRLS) of size 4Sqmm 1100 Volts grade drawing through existing surface/recessed rigid steel/ PVC conduit of dia not less than 20mm with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4 Sqmm single core (FRLS) as earth continuity conductor all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M&L for sub main wiring with using two single core PVC insulated, unsheathed cable with multi stranded copper conductor (FRLS) of size 6.0 Sqmm 1100 Volts grade drawing through existing surface/recessed rigid steel/ PVC conduit of dia not less than 20mm with standard accessories, along-with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sqmm single core (FRLS) as earth continuity conductor all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
S&F MCB single pole, 6 to 32 Amps having breacking capacity10 KA complete all as specified and directed. Make Legrand/Havell's/L & T
Re-installed of Indoor split units complete upto 2.0 Ton with new three core cable and suitable length of copper tube with insulations cover compelete and testing complete all as specified and directed by the Engineer-in- charge.
Refixing of fire detectors in false ceiling board complete all as specified and directed by the Engineer-in- charge.
Sunil Traders
M/s Sai Builders
UNIVERSAL AGENCY
M/s Yashika Enterprises
Manish Electricals
M/S Rakesh Verma
M/s Sohan Singh Mathur
SWAMI CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .