Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹16.8 L+₹15,075 (0.91%)Rejected-Finance DHARAM SALA SINGHAN CHADOORA DISTT BUDGAM J K | CHADOORA | BUDGAM | JAMMU AND KASHMIR | L2 | Rejected-Finance Being other than Lowest Tenderer | |
| 3 | L3₹18.4 L+₹1.7 L (10.5%)Rejected-Finance | L3 | Rejected-Finance Being other than Lowest Tenderer | |
| 4 | L4₹19.5 L+₹2.8 L (16.9%)Rejected-Finance | L4 | Rejected-Finance Being other than Lowest Tenderer | |
| 5 | L5₹21.8 L+₹5.2 L (31.0%)Rejected-Finance | L5 | Rejected-Finance Being other than Lowest Tenderer |
| Sl No | Description | Qty | Unit | Top Mind Industries Pvt Limited L7 | M/s Nasir Rasool Dar L3 | M/S M.Y Enterprises L6 | M/s GHULAM NABI HAJAM L8 | M/S LATIF AHMED MIR L4 | M/s Jaipal Associates L2 | M/S ZAHOOR ENTERPRISES L1 | M/S Noor Mohammad Shalla L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Taking down folloiwing fan of any type and size from site and removing to MES store for servicing like cleaning, lubricating, greasing and replacement of split pin, bearing, bush, connection wire and refixing the fan at same location complete all as specified and directed. Note :- (a) Contractor will provide one electrician and one helper for removing the faulty fan and refixing the serviced ceiling fan. (b) Contractor team will report to AGE E/M Sub Div daily except sunday and holiday at 0900 Hrs to collect ceiling fan complaints. (c) Contractor will give one year guarantee for repairable fan (except burnt out fans) (d) Rate quoted by the contractor shall be deemed to be inclusive of spare parts as required. | |||||||||||
| 1.01 | Ceiling fans of any size any sweep | 400 | Each | 100 ₹40,000 | 49 ₹19,600 | 50 ₹20,000 | 10 ₹4,000 Lowest | 450 ₹1,80,000 | 10 ₹4,000 Lowest | 50 ₹20,000 | 100 ₹40,000 |
| 1.02 | Exhaust fans of any size (metal body) | 100 | Each | 100 ₹10,000 | 50 ₹5,000 | 50 ₹5,000 | 10 ₹1,000 Lowest | 450 ₹45,000 | 10 ₹1,000 Lowest | 50 ₹5,000 | 150 ₹15,000 |
| 1.03 | Exhaust fans of any size (PVC body) | 100 | Each | 100 ₹10,000 | 50 ₹5,000 | 40 ₹4,000 | 10 ₹1,000 Lowest | 450 ₹45,000 | 10 ₹1,000 Lowest | 50 ₹5,000 | 80 ₹8,000 |
| 1.04 | Wall mounting / Air circulator fan of any size and type | 50 | Each | 50 ₹2,500 | 50 ₹2,500 | 50 ₹2,500 | 10 ₹500 Lowest | 450 ₹22,500 | 10 ₹500 Lowest | 50 ₹2,500 | 200 ₹10,000 |
| 2.00M&L for replacement of burnt out coil of copper and aluminium winded for following fans and rewinding complete with super enamelled copper wire of same guage and weight including replacement of bearing, bush, capacitor, insulation paper and varnishing including spray painting to complete fan including blade by applying one coat of synthetic enamel paint and testing complete including taking down, removal to workshop and refixing, complete all as specified and directed. Note :- 1. Rewinding work shall be carried out at AGE E/M store yard or any place decided by Engineer-in-Charge. 2. Contractor is responsible to give one year guarantee of (rewinding fans) | |||||||||||
| 2.01 | Ceiling fan 1200 / 1400mm sweep working on 230 volts AC supply | 335 | Each | 550 ₹1,84,250 | 450 ₹1,50,750 | 500 ₹1,67,500 | 1,000 ₹3,35,000 | 100 ₹33,500 Lowest | 500 ₹1,67,500 | 330 ₹1,10,550 | 400 ₹1,34,000 |
| 2.02 | Exhaust fan upto 600mm sweep working on 230 volts AC supply (metal body) | 30 | Each | 550 ₹16,500 | 1,500 ₹45,000 | 1,200 ₹36,000 | 1,000 ₹30,000 | 200 ₹6,000 Lowest | 1,000 ₹30,000 | 200 ₹6,000 Lowest | 1,100 ₹33,000 |
| 2.03 | Exhaust fan upto 450mm sweep working on 230 volts AC supply (metal body) | 30 | Each | 550 ₹16,500 | 1,100 ₹33,000 | 1,000 ₹30,000 | 1,000 ₹30,000 | 150 ₹4,500 Lowest | 800 ₹24,000 | 350 ₹10,500 | 750 ₹22,500 |
| 2.04 | Exhaust fans upto 300mm sweep working on 230 volts AC supply (PVC/steel body) | 100 | Each | 550 ₹55,000 | 1,000 ₹1,00,000 | 550 ₹55,000 | 800 ₹80,000 | 100 ₹10,000 Lowest | 400 ₹40,000 | 300 ₹30,000 | 300 ₹30,000 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
17 Jun 2026, 6:00 pmClosed
GE (AF) Srinagar
Garrison Engineer (AF) Air Force Station Srinagar 190 007
REPAIR / MAINTENANCE OF SUMMER APPLIANCES, HOT WATER APPLIANCES (GEYSER) AND OTHER MISC E/M WORKS UNDER GE (AF) SRINAGAR
2026_MES_767872_1
GE (AF)/SGR-31/2026-27
Open Tender
Civil Works
Item Rate
180 days
AOR of GE (AF) Srinagar
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Srinagar
₹66,000
Yes
29 Jul 2026
26 May 2026
19 Jun 2026
26 May 2026
17 Jun 2026
10 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Taking down folloiwing fan of any type and size from site and removing to MES store for servicing like cleaning, lubricating, greasing and replacement of split pin, bearing, bush, connection wire and refixing the fan at same location complete all as specified and directed. Note :- (a) Contractor will provide one electrician and one helper for removing the faulty fan and refixing the serviced ceiling fan. (b) Contractor team will report to AGE E/M Sub Div daily except sunday and holiday at 0900 Hrs to collect ceiling fan complaints. (c) Contractor will give one year guarantee for repairable fan (except burnt out fans) (d) Rate quoted by the contractor shall be deemed to be inclusive of spare parts as required. | |||||
| 1.01 | Ceiling fans of any size any sweep | 400 | Each | - | - |
| 1.02 | Exhaust fans of any size (metal body) | 100 | Each | - | - |
| 1.03 | Exhaust fans of any size (PVC body) | 100 | Each | - | - |
| 1.04 | Wall mounting / Air circulator fan of any size and type | 50 | Each | - | - |
| 2M&L for replacement of burnt out coil of copper and aluminium winded for following fans and rewinding complete with super enamelled copper wire of same guage and weight including replacement of bearing, bush, capacitor, insulation paper and varnishing including spray painting to complete fan including blade by applying one coat of synthetic enamel paint and testing complete including taking down, removal to workshop and refixing, complete all as specified and directed. Note :- 1. Rewinding work shall be carried out at AGE E/M store yard or any place decided by Engineer-in-Charge. 2. Contractor is responsible to give one year guarantee of (rewinding fans) | |||||
| 2.01 | Ceiling fan 1200 / 1400mm sweep working on 230 volts AC supply | 335 | Each | - | - |
| 2.02 | Exhaust fan upto 600mm sweep working on 230 volts AC supply (metal body) | 30 | Each | - | - |
| 2.03 | Exhaust fan upto 450mm sweep working on 230 volts AC supply (metal body) | 30 | Each | - | - |
| 2.04 | Exhaust fans upto 300mm sweep working on 230 volts AC supply (PVC/steel body) | 100 | Each | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
BOQ_859916.xls
BOQ • 0.43 MB
31Tender.pdf
Tender Documents • 1.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .