Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.5 L+₹1.7 L (8.82%)Rejected-Finance | L2 | Rejected-Finance Quoted amount more than L1 | |
| 3 | L3₹22.3 L+₹3.5 L (18.4%)Rejected-Finance 00 PANCHARIYA NEAR SANTOSHI MATA TEMPLE MAHARASHI GOUTAM MARG NEW LINE GANGASHAHAR BIKANER BIKANER BIKANER RAJASTHAN 334401 | BIKANER | RAJASTHAN | 334401 | L3 | Rejected-Finance Quoted amount more than L1 | |
| 4 | L4₹22.4 L+₹3.6 L (18.9%)Rejected-Finance | L4 | Rejected-Finance Quoted amount more than L1 | |
| 5 | L5₹22.4 L+₹3.6 L (19.0%)Rejected-Finance | L5 | Rejected-Finance Quoted amount more than L1 |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
20 May 2020, 12:00 pmClosed
Maj Vipin V Kumar
Garrison Engineer 07th Club Road Ranchi 834001
REPAIR/MAINTENANCE OF SEWAGE LINE, MANHOLE, SEPTIC TANK, SOAK WELL, AND CERTAIN MISC WORKS UNDER AGE B/R-I UNDER GE RANCH
2020_MES_334171_1
8200/1277/E8
Open Tender
Civil Works
Item Rate
330 days
Ranchi
Class E Cat a (ii)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹38,000
Yes
29 Jun 2020
14 Mar 2020
21 May 2020
15 Mar 2020
20 May 2020
19 Mar 2020
Amount
Excavation in trenches n.exc 1.5 m in depth and 1.5 m in width for foundation etc and getting out in any type of soil
Excavation over areas, n. exc 1.5m deep and getting out in any type of soil etc
All as per item No 2 above but depth exc 1.5mtr and n exc 3mtr complete.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of piep 150mm internal dia
M&L PCC (1:3:6) Type C-2 Concrete bed to drain pipe including packing under and haunching against the side or pipe after they are laid and tested for 150 mm dia pipe.
M&L 150mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches for sewage line complete.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel for 150 mm dia(1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required.
Demolition of brick wk masonry built in cement mortar incldg all quoins arches pillars etc
M & L old size Brick wk with sub class ‘B’ bricks straight or curved on plan exc. 6m means radius in built in CM 1:6 complete all as specified and directed.
M & L old size Brick wk with sub class ‘B’ bricks in one brick thick honey comb walling, built in CM 1:4 complete all as specified and directed.
M&L old size Brick work with sub class 'B' Bricks straight or curved on plan to any radius in half brick thick wall built in cm 1:4 complete all as specified and directed.
M&L loose filling of broken brick bats with aggregate of gauge 80 to 150mm in soakage pits & soakage wells etc. complete all as specified and directed.
Taking down cement plaster on brick walls incl. raking out joints, hacking for key, scrubbing down with water etc.
M & L, 15mm thick rendering on fair faces of brick work/concrete surface in CM (1:4) surface finished even & smooth without using extra cement complete all as specified and as directed.
M & L, 15mm thick rendering on fair faces of brick work/concrete surface in CM (1:6) surface finished even & smooth without using extra cement complete all as specified and as directed.
Demolition of cement concrete (reinforcement) any description and positin not other wise specifically.
M & L for RCC (1:2:4) type B-1using 20 mm graded stone aggregate as in slab , beam, col, Chajjas,Shelves/tank staging etc all as specified and directed.
M&L for precast RCC 1:2:4 manhole cover extra set in cement mortar 1:6 complete all as specified and directed
Use & waste frame work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelves including supports,overhangs,etc. also splays between floors and beams, etc.as in shelves
M & L Mild steel bars 10mm dia TMT Bars and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality conforming to
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m the starting point
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft / loose soil
Demolition of cement concrete (un-reinforced) in ground floors and paving n.exc 15cm thick (below or above ground level) complete all as specified and as directed.
M&L for cement concrete type C2 1:3:6 (40mm graded aggregate) in foundations filling and mass concrete, sub base etc complete all as specfied and directed.
M&L for 75mm thick Plain Cement concrete type C2 1:3:6 (using 40mm graded stone agg) as in plinth protection/ footpath finished the concrete surfaces even and smooth without using extra cement.
M&L for 75mm thick Plain Cement concrete type C2 1:3:6 (using 40mm graded stone agg) as in sub-base in floor
M & L machine pressed precast concrete interlocking paver block with grey cement and pigment (PVC Coated) any shape and size conferming to IS 15658-2006 of 60 mm thickness M-35 Grade over 40 mm thick sand complete all as specified incl filling interstices with sand complete all as specified.
M&L for providing chequered cement concrete tile 20cmx20cmx 25 mm thick set , jointed and pointed in neat cement slurry with grey cement and pigment over 20 mm thick screed bed in CM 1:6 in floor
S&F in repair PVC (SWR) pipes 110 mm single socketed in any length with rubberring joints, laid in trenches or in floors
All as per item No above but 75mm bore
S&F in repair PVC (SWR) pipes 110 mm single socketed in any length with rubberring joints fixed to wall complete.
S&F in repair PVC bends any radius 110 mm dia complete all as specified and directed
Ditto- all as per item No above but 75mm bore all as specified and directed
S & F in repair 110mm PVC (SWR), junction single, (Single T) equal or unequal all as specified and directed
S & F in repair 75mm PVC (SWR), junction single, (Single T) equal or unequal all as specified and directed
S & F in repair PVC 110mm(SWR) vent cowl all as specified and directed
S & F in repair PVC 75mm(SWR) vent cowl all as specified and directed
S&F in repair 32 mm bore dia of dishcharge pipe Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm- 45gms/40mm-60 gms)
Dismentaling floor, hearth or wall tiling, including cement mortar bedding (but not backing ) removing cerviciable tile to store & rubbish off the permisses.
M&L, 15mm thick screed bed or bedding layer of mortar in CM (1:6) for lying floor finishes and surface fair and even, complete all as specified and as directed.
M&L Non - skid joint free Ceramic tiles of any colour/shade 7 to 8 mm thick area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles complete all as specified and as directed.
M & L, 10mm thick rendering on fair faces of brick work/concrete surfaces of wall in CM (1:4) for laying wall tiles, surface finished even & fair complete all as specified and as directed.
M&L, glazed ceramic coloured tiles of size 300 X 200 X 6 to7mm thick as in walls etc set and jointed in neat cement slurry and pointed in colour cement to match the tiles complete all as specified and as directed.
M&L in repairs of Cast iron Nahani trap , Diameter of outlet in 100 mm with grating including jointing to waste pipe fixed in cement concrete typee B1 (1:2:4) complete all as specified and directed.
S & F in repair vitreous china wash hand basin, white flat back of size 550 mm x 400 mm including brackets and making necessary arrangement for fixing complete all as specified and as directed.
S&F in repair vitreous China urinals, bowl type flat back, size of 465x355x265mm white with grating and union for discharge pipe (back to corner wall type), complete including providing and fixing plus, bedding urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe.
S&F in repair vitreous china squating pan 'ORRISA' pattern, size 580X440mm white with integral foot rest complete including connection to trap and to antisyphonage pipe etc complete including making good to floor.
S&F in repair vitreous china pedastal pan water closet, white (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete and making good to floor complete all as specified and as directed.
S&F in reapir 10ltr capacity PVC low level flushing cistern, white inlet ball valve, float and handle and connection to pipe including bracket complete all as specified and as directed.
S&F in repair, 450mm long, 15mm dia, PVC connection pipe, with brass unions on both ends, complete all as specified and as directed.
S&F in repair EWC sheet cover to match EWC all as specified.
S&F in repair CP Health fauset with 1 Meter PVC Tube and hook complete all as specified and directed.
Complete removal of existing treatment of walls by washing rubbing down & stopping of painted surfaces and applying two coat of cement base paint, in any colour complete all as specified and as directed.Make: SUPER SNOWCEM/ DURACEM
M&L, applying two coats of white wash including preparation of newly plastered surfaces of wall complete all as specified and as directed.
M&L for preparing of old plastered surfaces of wall and applying one coat of exterior weather proof paint complete all as specified and as directed.
M & L PCC 1:2:4 type B-1 using 20 mm graded store aggregate as in coping/channel including use and waste of form work where necessary complete all as specified and as directed.
M&L finishing cement concrete surface even and smooth with using extra cement.
Cleaning of blockage of WCs,bathroom. kitchen & blockage of sewage line, mahole etc day to day basic as per complaint slip recceived from concerned AGE B/R-1 located karamtoli cell on all working days 0900 hrs to 1700 hrs only by manually all as specfied and directed by Engineer in Charge.
Dewatring /Desludging of septic tank/soak well /soak pit and Manhole by manually or mechanically and removing muddy soil sludge etc . The removal of sludge to a distance not exceeding 250 metre and burried in the same pit. Note : Measurement willb e done by deducting 50% of the quantam of work
PCC 1:2:4 type B-2 (40mm graded aggregate) as in pillars,walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillers and post (including caps and bases)
M&L MS Work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0.
M&L preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying a coat of red oxide primer and two coats of synthetic enamel paint complete.
S&F in repair galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing & straining and fixed to any type of standard rail incl securing or tying at crossing with and provision of galvanised MS wire staple or steel pins complete all as specified and directed by Engr- In - Charge..
M/S mahabirsahu
M K Enterprises
Balaji Construction And Company
jai maavindwashni sales & supply
Bihar traders
india trading company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .