Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance 47 HANDWARA HANDWARA HANDWARA BUDGAM JAMMU KASHMIR 191111 | BUDGAM | JAMMU AND KASHMIR | 191111 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance SARCH GANDERBAL J K 191131 | GANDERBAL | JAMMU AND KASHMIR | 191131 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
4 Aug 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER HORTI PnM
EXECUTIVE ENGINEER HORTI PnM RAJBAGH SRINAGAR
Electrification of agriculture complex at kupwara
2020_HPM_101074_7
NIT 07 OF 2020-21
Open Tender
Electrical Works
Item Rate
25 days
kupwara
Please refer Tender documents.
4 documents required · 4 mandatory
₹600
Yes
EXECUTIVE ENGINEER HORTI PnM
₹16,000
Yes
5 Aug 2020
23 Jul 2020
5 Aug 2020
23 Jul 2020
4 Aug 2020
23 Jul 2020
120 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular switch base, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Providing metal/wooden box of 150mmx 100mm size 60mm deep including chases made in the wall laid over with modular base and cover plate 15 amp modular socket and switch including making good with plaster and colouring etc
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
2X1.5sq.mm+1X1.5sq.mmearthwire
2X4sq.mm+1X4sq.mmearthwire
2X6sq.mm+1X6sq.mmearthwire
2x10sqm+1x6sqm wire
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
Providing,Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Supplying and fixing 16 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole 10- 25 amp
Double pole MCB 32 amp/64 amp
Providing and fixing of standard type fan dimmer s
Earthing with Gi earth pipe of specfied length 40mm dia including accessories and providing masonary enclosure with cover plate and havinh locking arrangenment including the costof chemical etc. complete
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required including providing and fixing of copper/GI tape 20mmx3mm thick for horizotal /vertical run as required
Providing andLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.above 85 Sqm up to 185 Sqm
Providing of standard quality Tube lights of 40 watt each including fixing etc and accessories
Providing ofLED Lights STANDARD quality of5w to20w as per the instructions of in charge engineer.
Supplying, installation, testing, and commissioning of floor mounted cubical front operated compartmentalized 415 volt main control panel system duly made of sheet steel 16 guage dust protected and vermin proof with gasket led lockable doors complete with inner connections crimping legs bounding to earth terminal and following controlling equipments. 01 NO 200 Amp TPN MCCB of Legrand/Eq make 36 KA breaking , 200 Amp TPN Bus Bar strips 2 set for generator and normal supply, 63 Amp change over switch panel type of Legrand /Eq make and 12 No Double pole MCB 32-63 Amp of Legrand/Eq make, Volt meter, Ammeter digital complete with phase to phase indicators (details and dimensions as per site requirements)
Providing, installing, testing and comissioning of three phase oil based/filled 30Kva.AVR, including all fittings complete job of approved brand and Manufacture.
M/S MOHD ASHRAF MIR
M/S AKHTER RASOOL GANIE
M/s AHMADULLA AND SONS
CHALKOO ENGINEERING WORKS
M/S BHAT ELECTRICALS
stage.html
html • 0.03 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .