Loading…
Loading…
Tender Value
₹3.3 Cr
EMD Value
₹3.2 L
Closing Date
5 Feb 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIG WORKS
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less, where: V= Advertised value of the tender in crores of Rupees N=Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet As per Clause No. 10.2 of Tender Form (second Sheet) of Annex. I of Part-I of GCC 2022,with up to date correction slip.
The tenderer must have successfully completed or substantially completed any of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of the advertised value of the tender, or (iii) One similar work each costing not less than the amount equal to 60% of the advertised value of the tender Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender,shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. As per Clause No. 10.1 of Tender Form second Sheet of Annex. I of Part-I of GCC 2022, with up-to-date correction slip.
Definition of similar work: "Any RRI/PI/EI/MACLS Supply, Installation,Testing, Commissioning Signalling work OR Any RRI/PI/EI/MACLS Alterations Signalling work OR Any CTC/TMS Work ".
62 conditions · 5 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderer should note that tender will be dealt as per GCC 2022 and latest amendments to it.
Rates in the schedule items of work are inclusive of all taxes as per clause 37 of GCC-2022
Wherever there is any ambiguity in SOR Item Description, that particular item description in latest RDSO Specification to be considered as FINAL.
Telecom Circular No. 09/2023 (copy attached) shall be religiously followed for undertaking digging work in the vicinity of Signalling, Electrical and Telecommunication Cables. Zonal Railways issued local instructions/JPO for protection of cables while undertaking works in the vicinity of Railway Tracks in line with Telecom Circular 09/2023.
S&T work in connection with provision of Track Machine Siding at Naraina, Dahar Ka Balaji , Lachhmangarh Sikar, Ramgarh Shekhawati and Baniyana stations of Jaipur Division
SNT-JP-29-2025-26~NWR
SNT-JP-29-2025-26
Open
Works - General
12 Months
Jaipur, Rajasthan
₹0
₹3.2 L
5 Feb 2026
12 Jan 2026
22 Jan 2026
157 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,38,23,181.59 | ||
| — | 5.00 | — | — | ||
| Translation of Station Working Rules from english to hindi and framing out in DIGLOT form (or similar software )as per extant Rly practice. The required SWR in english will be provided by the contractor and has been covered separately in item no. 1.21 of Chapter 1 of this SOR. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | — | — | — | 22,390.9 | |
| — | 30.00 | — | — | ||
| Making photocopies & binding of the SWR literature in English/hindi/Diglot form as per Railway practice. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | — | — | — | 5,355.6 | |
| — | 5.00 | — | — | ||
| Designing and Plotting of Signaling Interlocking Plan(SIP) in AUTOCAD. Two copies of prints with soft copy will be submitted to Railway for checking. If alterations are suggested/proposed by Railways then again two copies of prints will be submitted for advance approval after carrying out all the alterations as suggested/proposed by the Railways. Tracings will be submitted for all the diagrams mentioned above for the purpose of approval by Railway prior to commissioning of station. Inspection: Consignee Inspection charges: None Payment terms:100% after execution.(Per Unit should be read as Per SIP) | — | — | — | 1,40,310 | |
| — | 500.00 | — | — | ||
| Preparation and supply of laminated one set of all the completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75-micron polyester film for station in Auto CAD. 6 (Six) sets xerox copies will also be provided for each of the documents mentioned below: Cable Route Plan, Cable Core Chart, Location details plan for all the locations, Cable termination details, Signalling Plan, SWR Diagram, Wiring Diagrams, Selection table, Locking table, Contact analysis, Fuse and Tag Block analysis of Relay Rack, CT rack, Control cum Indication Panel/VDU Diagram, Power Panel Diagram, Track circuit plan, rack erection plan and Junction Box details etc. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | — | — | — | 80,535 | |
| — | 500.00 | — | — | ||
| Addition/alteration in existing relay room wiring. It includes supply of PVC insulated indoor Railway signalling cable @ 40<45@Core/40-Core) of (1/0.6) sqmm as per RDSO Spec.No.IRS/S-76/89 (Amnd.2 or latest) for wiring between relay room and SM's/Panel room & Relay room to DP in SM office for block working. This also includes supply of PVC insulated jumper wires of multi strand 16/.2 mm, tinned in all colours as per RDSO Specn.No.IRS-S-76/89(Amnd.2 or latest). This item will include bringing all the power supplies from power room to respective bus bars on relay racks by using 10/6 sqmm copper flexible wire as per instructions of engineer incharge. This will include wiring between control panel and relay room if required. All wiring will be done as per standard practice of North Western Railway with neat dressing & threading. The item includes supply & wiring of tag block, fuse with bases(G-Type and ND Type) and all other related material required for complete indoor wiring in relay room. Inspection: Consignee Inspection charges: None Payment terms:100% after commissioning. | — | — | — | 2,62,050 | |
| — | 100.00 | — | — | ||
| Supply of Q-Series LED ECR (Universal Type i.e.QECX-61), 4F/4B complete with plug board(base plate), connectors, retaining clips etc and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 ,Amdt.-1and RDSO Specn.No.IRS:S-34 & S-23 or latest.The interlocking code for this unit shall be ""ABDHK"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 4,98,353 | |
| — | 150.00 | — | — | ||
| Supply of Q-Series Line Relay (QNA1 Type),AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S@ 45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be ""ABDGH"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 5,87,050.5 | |
| — | 150.00 | — | — | ||
| Supply of Q-Series Line Relay (QNA1 Type), AC immunized, 12F/4B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S@ 45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be ""ABDFH"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 5,70,825 | |
| — | 50.00 | — | — | ||
| Supply of Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS:939A & 966(Appendix F2) or latest.The interlocking code for this unit shall be ""FGHKX"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 1,86,735 | |
| — | 200.00 | — | — | ||
| Supply of Q-Series Neutral Line Relay (QN1 Type ), 12F/4B, 24V DC complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be ""ABCDE"". Inspection authority:- RDSO Inspection charges:- Bornee by Railways Payment Terms:- 100% after supply. | — | — | — | 7,88,712 | |
| — | 200.00 | — | — | ||
| Supply of Q-Series Neutral Line Relay (QN1 Type ), 8F/8B, 24V DC complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be ""ABCDF"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 7,57,874 | |
| — | 150.00 | — | — | ||
| Supply of Q-Series Twin Neutral Line Relay(QNN1 Type), 6F/2B, 24V DC complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS-960 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be ""ACDEK"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 7,47,799.5 | |
| — | 50.00 | — | — | ||
| Supply of Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B,24V D C complete with plug board(base plate), connectors and retaining clips and conforming to BRS- 935A and RDSO Specn.No.IRS:S-34 & S-23 or latest.The interlocking code for this unit shall be ""ABDEG"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 2,85,072.5 | |
| — | 50.00 | — | — | ||
| Supply of Point Contactor relay AC immune, plug in type, style QBCA1 DC biased contractor, (QBCA1 Type), 24 V DC, 2F(HD)2F-4B contacts , heavy duty metal to carbon front contacts and back contacts metal to carbon, complete with plug board, retaining clip & connectors, conforming to BRS- 943 and IRS:S-34 & S-23 or latest. The interlocking code ""DEHJX"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 3,54,000 | |
| — | 75.00 | — | — | ||
| Supply of Q-Series Neutral Line Relay(QSPA1 Type), 24V DC,8F/4B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-933A and RDSO Specn.No.IRS:S@ 45"44@ S-23 & S 60 or latest.The interlocking code for this unit shall be ""ABDEJ"". Inspection authority:- RDSO Inspection charges:- Borne by Railways Payment Terms:- 100% after supply. | — | — | — | 3,90,845.25 | |
| — | 20.00 | — | — | ||
| Supply of Key Lock Checking Relay (KLCR) working on 24V DC, AC Immunized with different ward combinations and contact configuration 4F/4B with 2 extra ward plates and with case, RDSO spec no. RDSO/SPN/219/2016 ver 1.0 or latest, confirming to IRS S-23, S-34 & S@ 45<44@ IRS S:46. Inspection authority:- For bare relay -RDSO, for key lock housing- consignee Inspection charges:-Bornee by Railways Payment Terms:- 100% after supply. | — | — | — | 1,88,800 | |
| — | 2500.00 | — | — | ||
| Supply of 1 x 6 Sqmm (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 84 conductor each dia 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test parameters as per RDSO Specn.No.IRS:S- 76/89(Amnd.3) or latest.Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways(ii) None Payment Terms: 100% on Supply | — | — | — | 90,925 | |
| — | 500.00 | — | — | ||
| Supply of Cartridge Fuse Block made of PBT and as per RDSO Drg. No. SA-23748 (Alt. 4) or latest and RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest. Inspection: RDSO. Inspection Charges: Borne by Railways. Payment Terms: 100% on supply. | — | — | — | 76,490 | |
| — | 32.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet of size 10/12/20 mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. Single Case (Large Case) | — | — | — | 75,023.68 | |
| — | 2500.00 | — | — | ||
| Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engg. incharge of the work. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution | — | — | — | 21,150 | |
| — | 3000.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signaling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3) | — | — | — | 1,63,890 | |
| — | 200.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signaling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply Supply of End plate for item 4.28(i) of Chapter 4 of revised SOR 2.5mm/0.091 in thick as per site requirement. | — | — | — | 2,048 | |
| — | 500.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signaling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply Supply of End Stopper for item 4.28(i) of Chapter 4 of revised SOR 10mm/0.0394 in width as per site requirement. | — | — | — | 5,120 | |
| — | 100.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signaling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply Supply of Carrier Rails for item 4.28(i) of Chapter 4 of revised SOR 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. | — | — | — | 10,698 | |
| — | 3000.00 | — | — | ||
| Supply of Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004(Modular Terminal Blocks, Fuse Terminal Blocks &Miniature fuse link of international standard for Railway signaling) With latest amendments. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply Supply of Markers strip for item 4.28(i) of Chapter 4 of revised SOR | — | — | — | 47,790 | |
| — | 100.00 | — | — | ||
| Supply of D type fuse block non indicating type low voltage non deteriorating fuse base suitable for fuse link of capacity 2A/6A/10A as per specification IRS:S-80/92 or latest . Quantity break up of each type of fuse block will be specified by Engineer in-charge. Inspection: Consignee Inspection Charges: None Payment Terms: 100% on supply. | — | — | — | 2,959 | |
| — | 100.00 | — | — | ||
| Supply of D type fuse link non indicating type low voltage non deteriorating, capacity 2A/6A/10A as per specification IRS:S-80/92 or latest. Quantity break up of each type of fuse block will be specified by Engineer in-charge. Inspection: Consignee Inspection Charges: None Payment Terms: 100% on supply. | — | — | — | 3,073 | |
| — | 100.00 | — | — | ||
| Supply of uncharged Low Maintenance Lead Acid (LMLA) secondary cell, shelf mounting type conforming to RDSO Specn.No.IRS:S-88/2004 or latest with inter cell connectors, nuts and bolts etc. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. 2V, 80 AH | — | — | — | 2,06,793 | |
| — | 100.00 | — | — | ||
| Charging of Lead Acid Batteries with contractors own battery grade sulphuric acid and distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of N.W.Rly & instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution. 2V 80AH | — | — | — | 37,102 | |
| — | 5.00 | — | — | ||
| Fixing, wiring, testing and commissioning of Electrical Point Machine on the extended sleepers at points as per std. practice and as per RDSO Drg No. SA 9151-52 or 9710 or 9161 or 10800 or 11000 as per section of rails used. Item includes fixing switch extension bracket, providing insulation for switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle.The item also includes : (i)Complete material for installation like ground-connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts including castle nuts, spring washers (ii) All smithy & fitting works required at site for complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be Provide by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on NWR and the instruction of Railway Engineer at site. (v) Supply and fixing of suitable size GI pipes with flange for taking cable into point machine. Note ; The ground connections shall be suitable to the Point Machines as specified by Engineer-in-charge and shall be suitable to the point lay out i.e. 60 Kg. / 52 Kg / 90R as per yard layout. Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Commissioning. | — | — | — | 1,37,930.05 | |
| — | 20.00 | — | — | ||
| Supply of Track feed Battery Charger as per RDSO Specn. No.IRS: S-89/2013 Ver.1.0 or latest. Charging Capacity Rating 10 Amps for Charging 80 AH Battery. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. | — | — | — | 90,102.4 | |
| — | 20.00 | — | — | ||
| Supply of Adjustable Track Feed Resistance 30 Ohms (Disc Type) as per RDSO Drg. No.SA-20161-66/M or latest. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | — | — | — | 28,783.4 | |
| — | 10.00 | — | — | ||
| Fixing and wiring of DC track circuit equipments i.e. track feed charger, resistance, track relay, battery, B type choke etc., in the Apparatus Case and battery box as per standard practice. Termination of tail cable on M 6 / Screw less terminals WAGO or FINOLEX or similar approved make teminals/ fuse blocks / HRC fuse. Item includes testing /commissioning of track circuit. Complete wiring material will be supplied by contractor. (Supply of Track feed battery charger, track feed battery, resistances & 'B' type choke & Track relays, ARA terminal/Modular terminals wago/phoenix contact type will be supplied by Railways / covered in Schedule separately). Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution. | — | — | — | 63,540.1 | |
| — | 10.00 | — | — | ||
| Installation of DC track circuits covering all types of Track circuts including points zones also.The item includes provision of doubled continuity GI wire bonds on rail joints after drilling bond-hole of 7.0/7.2mm dia, skimming of fish plate, insertion of insulated block joint( if required), fixing of TLJB (separate for positive & negative rails) with angle iron for track feed/jumper/track relay ends of track circuits and also for fixing jumper cables as per approved Track Circuit Plan, making rail connections through suitable insulated sleeves from TLJB at TF, jumper & TR end with GI wire, rail clips for fixing bond wire on the TLJB as per standard practice, termination of tail cables on TLJB terminals etc. TF/TR wiring shall be fixed on the suitable arrangement on PRC sleepers with the help of Hooks. In case Engineer at site desires that jumpering from TLJBs is to be done using signalling cable 2 coreX 2.5 sqmm , contractor shall provide the jumpering cable using 2 X 2.5 sqmm signalling cable.The signalling cable will be supplied by Railways. Hooks shall be provided on PRC sleepers with the help of suitable steel bracket. This item also includes fixing & supply of channel pins, Hooks etc. The item does not include includes supply of TLJB as per RDSO Drg.No.RST-11509 or latest as per technical specs Installation of of Track Lead Junction Box(TLJB) as per Drg.No.RST-11509 or latest made from FRP material including brass bolts and hylam board sheet with terminals etc. (a) Installation and commisssioning of TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90 mm and all the holes required for mounting on FRP stump (verticall two for each FRP angle) HDPE pipe , cable etc. (b) Installation and commisssioning of Each TLJB having two bakellite terminal block fitted horizontally : each bakellite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long.Alongwith each TLJB , nickel chrome plated brass links(two nos.0f adequate strength for vertical linking of the terminals to be wired and fixed properly. (c) Installation of HDPE pipe of size 32/35mm , 380 mm long alongwith two nuts for fixing on the TLJB hole . (d) Installation of the FRP stump for mounting the TLJB to be made of one meter long 30mm X30mmX 4mm angle(2 nos.) and 300mm long 30mm X30mmX 4mm angle(1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts.The TLJB and the angles for stump should be fixed in given holes on them for fixing using galvanised nuts and bolts . Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution. | — | — | — | 79,529 | |
| — | 90.00 | — | — | ||
| Supply of Track Lead Junction Box(TLJB) as per Drg.No.RST-11509 or latest made from FRP material including brass bolts and hylam board sheet with terminals etc. The technical specifications are as follows: (a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W-212mm and H 90 mm and all the holes required for mounting on FRP stump (verticall two for each FRP angle) HDPE pipe , cable etc. (b) Each TLJB shall have two bakellite terminal block fitted horizontally : each bakellite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long.Alongwith each TLJB , nickel chrome plated brass links(two nos.0f adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe of size 32/35mm , 380 mm long alongwith two nuts for fixing on the TLJB hole . (d) The FRP stump for mounting the TLJB to be made of one meter long 30mm X30mmX 4mm angle(2 nos.) and 300mm long 30mm X30mmX 4mm angle(1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts.The TLJB and the agles for stump should come alongwith holes on them for fixing using galvanised nuts and bolts of adequate strength to be supplied alongwith TLJB drawing no. 11509. Inspection: (i) RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 1,60,056 | |
| — | 35.00 | — | — | ||
| Supply of B Type Choke as per RDSO Specn.No.IRS:S-65/83 (Amnd. 1) or latest. Inspection: RDSO Inspection Charges: Borne by Railways. Payment Terms: 100% after supply. | — | — | — | 1,43,462.9 | |
| — | 1500.00 | — | — | ||
| Supply of Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | — | — | — | 8,535 | |
| — | 5.00 | — | — | ||
| Supply of Position Light Shunt Signal Unit Complete with Post(made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990, Base, Hood, Cover etc as per Drg. No. SA-23840 suitable for LED Signal Lighting Unit.(Supply of LED Unit is not covered in this item) Inspection: (i)RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 21,487.35 | |
| — | 5.00 | — | — | ||
| Erection of Position Light Shunt signal with Base, Post, Signal unit and fixing of Number Plates. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Commissioning. | — | — | — | 8,899.95 | |
| — | 5.00 | — | — | ||
| Casting of C.C. Foundation for Position Light Shunt Signal/ Indicator/SPI as per Drg.No.CSTE/NWR/SOR/ 22 in ratio 1:3:6 by using standard size of galvanized holding down/foundation bolts. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement sand mixture. Aggregate cement, sand and holding down bolts, will be supplied by contractor. Any machines and tools, if required for execution of this item, will be arranged/provided by contractor. Note: As per available site conditions, if sizes of foundations are required to be decreased/ increased and same has been approved/agreed by engineer incharge then variation in CC work will be calculated on volumetric basis as per rates of these items. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. ." | — | — | — | 31,551.3 | |
| — | 20.00 | — | — | ||
| Cement concrete work for miscellaneous items in ratio 1:3:6. Item includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture (aggregate will not exceed beyond 3.8 cm). The aggregate cement and sand will be supplied by contractor. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation.(Unit is per cubic meter) | — | — | — | 86,477 | |
| — | 32.00 | — | — | ||
| Installation of Apparatus Cases Single(Large) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | — | — | — | 33,250.88 | |
| — | 14.00 | — | — | ||
| Installation of Apparatus Cases Half (Medium) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of Location lamp holder , switch and lamp etc. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | — | — | — | 8,858.92 | |
| — | 32.00 | — | — | ||
| Excavation and Casting of Apparatus Case foundation in ratio 1:3:6 with contractor's own materials including cement and galvanized anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.The item also includes additional masonry work as well as earthwork if required on bank where there will be possibilities of foundation sinked, fallen or tilted. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. Single (Large) Case Apparatus case / SS location box as per Drg No. CSTE/5074 | — | — | — | 2,20,445.44 | |
| — | 14.00 | — | — | ||
| Excavation and Casting of Apparatus Case foundation in ratio 1:3:6 with contractor's own materials including cement and galvanized anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.The item also includes additional masonry work as well as earthwork if required on bank where there will be possibilities of foundation sinked, fallen or tilted. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. Half (Medium) Case Apparatus case / SS location box as per Drg No CSTE/5074 | — | — | — | 73,628.24 | |
| — | 32.00 | — | — | ||
| Supply of Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 20 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. Inspection: (i) RITES if value of item in work more than 5 lakhs or as per extant policy (ii) Consignee Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | — | — | — | 3,06,030.4 | |
| — | 14.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet of size 10/12/20 mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per instructions of Rly engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. Half Case (Medium Case) | — | — | — | 9,576 | |
| — | 3000.00 | — | — | ||
| Supply of ARA Terminal Block (M-6) made of PBT/Poly Carbonate as per RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest and RDSO Drg.No. SA-23741A(Alt. 4) or latest. Inspection: RDSO. Inspection Charges: Borne by Railways. Payment Terms: 100% on supply. | — | — | — | 2,62,230 | |
| — | 3000.00 | — | — | ||
| Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. (Supply of all above terminals have been covered separately in Chapter 4 of SOR) Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | — | — | — | 37,560 | |
| — | 5.00 | — | — | ||
| Fixing of KLCR relays in field in half location boxes if Gate lodge is not provided or at any other location as decided by engineer in charge. Item includes supply and fixing of MS sheet and wiring of KLCR relays, push buttons and LEDs for KLCR circuit. The KLCR relays, push buttons, LEDs will be fixed on a MS sheet of min. 3mm in the half location box. The MS sheet will cover full length and breadth of the half location box and divided in two pieces of approx. 48cm x 46cm and 80cm x 46cm. The first piece to be fitted on top and will contain the KLCR relays, LEDs and push buttons. The second piece to be fitted below the first piece. (Supply of KLCR relays covered in separate item of SOR). Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | — | — | — | 10,966 | |
| — | 550.00 | — | — | ||
| Supply of Medium class GI pipes 100 mm dia(4.5 mm thickness) as per IS 1239 ( Part 1 ) : 2004 with coupling on culverts bridges as per Drg.No.CSTE/NWR/SOR/06 to 12 or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | — | — | — | 4,18,363 | |
| — | 550.00 | — | — | ||
| Fixing of Medium class GI pipes 100 mm dia(4.5 mm thickness) as per IS 1239 ( Part 1 ) : 2004 with coupling on culverts bridges as per Drg.No.CSTE/NWR/SOR/06 to 12 or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work(if required) to protect the cables from sharp edges and sudden bends. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | — | — | — | 1,04,593.5 | |
| — | 1000.00 | — | — | ||
| Supplying and placing of one layer of standard size of B grade quality bricks of the local make spreading on cables laid.(minimum size of brick 200mm X 100mm X 70mm) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Installation. Lengthwise (up to 2 cables).(Unit is per RM Running Meter) | — | — | — | 14,800 | |
| — | 4000.00 | — | — | ||
| Supplying and placing of one layer of standard size of B grade quality bricks of the local make spreading on cables laid.(minimum size of brick 200mm X 100mm X 70mm) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Installation. widthwise ( more than 2 cables).(Unit is per RM Running Meter) | — | — | — | 1,27,480 | |
| — | 20.00 | — | — | ||
| Jointing of 4 / 6 quad /Signaling cable with Heat Shrinkable straight through Jointing Kit. All the material required for the work are to be arranged by contractor himself at his own cost except Thermo shrinkable Joint Kit/Rapid Joint kit. After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | — | — | — | 23,149 | |
| — | 800.00 | — | — | ||
| Horizontal direction drilling/boring without damage of surface road /track using Auger Machine(HDD machine). The bore shall be upto 200 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This include insertion of different dia DWC-HDPE pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note:- Pipe Supply is not covered under this item. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution. | — | — | — | 9,62,376 | |
| — | 2400.00 | — | — | ||
| Horizontal Drilling by using manual pushing method at minimum depth of 1.5 meter below the formation level of earth as per decision of Engineer in charge .Pipe Supply is not covered under this item Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | — | — | — | 2,94,576 | |
| — | 1800.00 | — | — | ||
| Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Western Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1.2m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1.2m. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution( Unit is Cubic Meter) | — | — | — | 4,93,704 | |
| — | 100.00 | — | — | ||
| Digging of trench 1.2 Mtrs. deep from rail flange/ road level and 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No.CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution( Unit is Cubic Meter) | — | — | — | 27,428 | |
| — | 400.00 | — | — | ||
| Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches.The sharp edges will be smoothened out in bottom of the chase and will be leveled properly. In hard rocky ground area , cables will be laid normally on layer of shifted earth of 0.05 mtrs thickness previously deposited at bottom of the trench and cables will be covered with layer of sand or shifted earth of 0.1 mtr thickness. In case sharp edges of rocky ground can not be protected from shifted earth then GI/ CI /PVC /DWC/ HDPE pipes will be used, if numbers of cables is small.In case number of cables are large RCC duct will be used. In isolated cases, it can be given smooth surface by using either masonry bricks or cement concrete. A row of bricks shall then be placed length wise on the top and jointed with cement mortar and layer of concrete with cement plaster shall be provided on top of the same. Note: This item in hard rocky area will be operated only where normal depth i.e.l.2 mtr is not possible and it will be decided by site engineer/unit officer incharge of work. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution( Unit is Cubic Meter) | — | — | — | 2,01,216 | |
| — | 20000.00 | — | — | ||
| Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometer post.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution(unit is RM running meter) | — | — | — | 1,82,000 | |
| — | 5.00 | — | — | ||
| Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution(Unit is cubic meter) | — | — | — | 9,952.7 | |
| — | 2.00 | — | — | ||
| Supply of Compact portable gasolin rail drill machine with belt cover ( HM-36) drilling capacity 6 to 36 mm. Suitable for 52 Kg , 60 Kg. Tongue rail, point machine base plate .Weight :approx. 15Kg without attachment. Machine size(Max):HxLxW:480x350x260mm, Barrel dia:52+/-1 mm, drilling time 45 second, clamping 25 sec, declamping 15sec. Inspection:RITES Inspection Charges: None Payment Terms: 100% after Supply | — | — | — | 16,43,400 | |
| — | 3.00 | — | — | ||
| Supply of Pre-lubricated HDPE duct, 40 mm OD, 33 ID as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev. 2.0 or latest. The item also includes supply of all the accessories of HDPE duct like end caps, collars, bends, couplers etc. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | — | — | — | 1,44,939.78 | |
| — | 3.00 | — | — | ||
| Laying of Pre-lubricated HDPE duct, 40 mm OD, 33 ID as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev. 2.0 or latest. The item also includes installation of all the accessories of HDPE duct like end caps, collars, bends, couplers etc. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution. | — | — | — | 36,234.93 | |
| — | 2.00 | — | — | ||
| Blowing/drawing of OFC cables in the HDPE duct along with all the protective work as per instructions of engineer incharge at site. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution. | — | — | — | 21,609.54 | |
| — | 20.00 | — | — | ||
| — | — | — | 2,55,044 | ||
| — | 20.00 | — | — | ||
| — | — | — | 87,296.4 | ||
| — | 20.00 | — | — | ||
| — | — | — | 42,974.6 | ||
| — | 3.00 | — | — | ||
| — | — | — | 10,884.78 | ||
| — | 30.00 | — | — | ||
| Installation of Unit Maintenance Free Earth as supplied under item no. 13.3 of Chapter 13 of SOR . It includes ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 micrones to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip- potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specn.No.RDSO/SPN/ 197/2008 or latest and conforming to RDSO Drg.No.S DO/RDSO/E&B/001 or latest. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution and testing. | — | — | — | 2,35,850.4 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .