Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC OLD AIRPORT ROAD W ANBAL SRINAGAR J K 190005 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190005 | L1 | Accepted-AOC LOWEST L1 | |
| 2 | L2₹16.0 L+₹1.2 L (8.24%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹16.1 L+₹1.4 L (9.32%)Rejected-Finance R O RAWALPORA WANBAL YAIYAL TEH DISTT SRINAGAR J K PIN 190005 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190005 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹17.8 L+₹3.0 L (20.6%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹17.8 L+₹3.1 L (20.8%)Rejected-Finance NAMBLABAL PAMPORE DISTRICT PULWAMA JAMMU KASHMIR 192121 | PAMPORE | PULWAMA | JAMMU KASHMIR | 192121 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE 970 EWS C/O 56 APO PIN 913970
REPAIR AND MAINT OF INTERNAL WIRING INCL ELECTRIC FITTINGS, FIXTURES AND CONNECTED ITEMS IN PERMANENT AND TEMPORARY BLDGS AT HAFT CHINAR AND TATTOO GROUND UNDER GE 970 EWS
2022_MES_537989_1
GE 970 EWS-34/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 970 EWS C/O 56 APO
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹60,000
Yes
10 Mar 2023
14 Jul 2022
6 Aug 2022
14 Jul 2022
4 Aug 2022
29 Jul 2022
60 days
Amount
Taking down carefully any type of copper/aluminium point wiring (light, fan, socket or power) complete including conduits/casing caping with fittings such as switches, ceiling roses, pendents, regulators, bells, sockets, fan regulator etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LS conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LS as continuous earth wire drawn in and including PVC Casing & Caping double lock type of as required width (not less than 20 mm in width) ISI marked medium grade white colour or Non metallic rigid PVC Conduit not less than 20 mm dia as per ground requirement with all accessories of same grade fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box of required size made out of 2mm thick MS sheet duly painted both sides or PVC box ISI marked with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers for mounting switches, fan regulators etc for one light/fan/exhaust fan point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per item No. 2 here in before,but for one light point controlled by two 2-way switches all as specified and as directed.
All as per item No 2 here in before, but for one 3/5 Pin, 5 Amp switch socket out let on the independent board complete all as specified and as directed
All as per item No 2 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the same board complete all as specified and as directed
M & L for surface point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LS conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LS as continuous earth wire drawn in and including PVC Casing & Caping (double interlock type) of as required width (not less than 20 mm in width) ISI marked medium duty, white colour with all accessories of same grade, fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box of required size made out of 2mm thick MS sheet duly painted both sides or PVC Box ISI marked with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers for mounting switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed.
M & L for sub main wiring with two runs of single core 4 Sqm, FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing caping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 2.5 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit)
Ditto all as per item No 8 here in before, but two run of single core 6 sqmm and one run of 4 sqmm cables as earth continuity conductor all as directed.
Ditto all as per item No 8 here in before, but four run of single core 10 sqmm and two runs of 6 sqmm cables as earth continuity conductor all as directed.
Switch Piano flush button single pole one way 5 A , 240 V complete all as specified and as directed
Switch Piano flush button single pole two way 5 A , 240 V complete all as specified and as directed
Switch Socket combination 2 in 1, 5 Amp flush type, 240 V, complete all as specified and as directed
Switch Socket Combination 5A/16A, 5 in 1, 3 pin, 240 volts complete all as specified and as directed
Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 volts complete all as specified and as directed
Stepped type electronic fan regulator flush type as per exisitng model on the existing board all as directed.
S & F in repairs MCB DB SPN 8 way, 230 Volt with 200 A rated bus bar double door type modular type complete all as specified and as directed.
Ditto all as per item No 17 here in before but MCB DB SPN 12 way DB 230 V with 200 A rated busbar.
Ditto all as per item No 17 here in before but MCB DB TPN 4 way DB 415 V with 200 A rated busbar.
S & F MCB TPN 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F MCB SPN 40 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with & including 15 watt LED bulb complete all as specified and directed.
S & F in repairs supply and fixing 1 x 20 watt LED 6000K (4Ft) Decorative ultra slim square profile linear LED lighting fixture with extruded polycarbonate environment friendly, energy efficient, extruded plastic and deorative end cap body Heat srink. Provided for efficient disspation and integrated electronic driver copmplete with lamp Make Havells CAT No LUMILINESSBS9WLED830SPCWH (HSN Code 9405).
S & F in repairs 1x 09 watt LED 6000K (2Ft). Decorative ultra slim square profile linear LED lighting fixture with extruded polycarbonate environment friendly,energy efficient, extruded aluminium body Heat srink. Provided for efficient disspation and integrated electronic driver copmplete with lamp Make Havells CAT No LHEXBTP7UN1W009 or equivalent philips / bajaj /CG.
M&L in repairs for Earthing complete with GI earth plate 60x60cmx6mm thick, burried directly in ground (Earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron as earthing lead or steel all as shown in electrical plate No.5 and incl earth work, PCC pit and RCC cover, watering pipe 20mm dia medium grade, funnel, wiremesh, charcoal dust, 15 mm dia light grade protection pipe and salt etc and connected to earthing test point incl necessary earth work complete all as specified and as directed.
M/S KHAN ENTERPRISES
M/S LATIF AHMAD BABA CONSTRUCTION
FG CONSTRUCTION
ms new dar water star
Javeed And Co
M/S Tajamul Ah Buchh
M/S B A Traders
Top Mind Industries Pvt Limited
M/S SHOWKAT AHMAD WANI AND SONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .