Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 397 JASPREET SALUJA INDORE VISHNUPURI ANNEX INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹45.8 L
EMD Value
₹91,600
Closing Date
17 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA
Repair and Replacement of Security light, Flood lights with other connecting items at 213 Transit Camp under GE Nagrota
2022_MES_552973_1
GEN-67/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NAGROTA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹91,600
Yes
22 Oct 2022
19 Sept 2022
19 Oct 2022
19 Sept 2022
17 Oct 2022
3 Oct 2022
Amount
Taking down security light fiting HPSV / HPMV /HPMH/Post top lantens/flood light/LED light fittings etc of any capacity from any height any situation and re-fixing/ re-hanging the same in existing location or other location (as directed) after carrying out repair works on light fittings including testing complete all as specified and directed by Engineer-in-Charge. Note :(i) The rate quoted for the above item shall be deemed to be included for neccessary charges for replacement of the all defective parts/fittings but cost of fittings viz: ballast of any type, ignitor, holder, lamp/tube/LED Lamp of any type, capacities required will be measured & paid separately under appropriate items of Sch 'A' here in after.
Supply and fix in replacement of LED Lamp 30 Watt pin type suitable for fix in batton holder complete.
S&F for lamp holder PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply and Fixing in replacement of old burnt constant current driver suitable for followning LED security light/Flood light fitting of 25 to 60 W capacity complete all as specified and directed by Eng in Charge
Supply and Fixing in replacement of old burnt constant current driver suitable for followning LED security light/Flood light fitting of 72 to 100 W capacity complete all as specified and directed by Eng in Charge
Supply and Fixing in replacement of old burnt constant current driver suitable for followning LED security light/Flood light fitting of 120 to 180 W capacity complete all as specified and directed by Eng in Charge
Supply and Fixing in replacement of unsv burnt surge protection device of capacity 10 kv complete suitable for security light fitting of any capacity complete all as specified and directed by Eng- in- Charge
Supply and fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street light based on LUX level of nature light having ON ≤ 30 lux and OFF ≥ 10 Lux . The sensor (Nature Switch) along with suitable power contactor , MCB and support termianl should be enclosure made of rust proof, electric shock proof , termite proof and FR grade SMC junction box(sintex make) conforming to confirmining IS 13947.4-1 & IS 8828, IP 66 including contactors ( 3 Nos each) and incoming- ourgoing MCBs ( 3 Nos each) rating of 25-40 amp and Circuit copper wiring of min 10 Sqmm cable incl taking down old unsv complete all as specified and directed. Make: Swadeep -02EC5kW3P , or Equivalent to Indoasian /Legrand
S&F of 90 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 9900 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters .side entry mounted for 40 mm and above OD pipe bracket etc incl taking down old unsv light fittings complete all as specified and directed by Engr in- Charge . Make:Bajaj Cat NoENXT P 108L WH PO TG SD Phillips /Wipro
S&F of 60 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 6600 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters .side entry mounted for 40 mm and above OD pipe bracket etc incl taking down old unsv light fittings complete all as specified and directed by Engr in Charge . Make: Bajaj Cat Part No ENXT P 72L WH PO TG SD /Phillips /Wipro
S&F of 120W LED Flood Light luminaire made up of Matt black ptextured powder coated pressure Die Cast aluminum housing and frame with heat resistant toughened clear glass fixed with SS screw/ Ant dust exposed lens, sturdiness and embossed brand name/ logo name of manufacturer on fixture . The luminaire should have a minimum system lumen output of 14400 lumens and 120 Watts. The fixture shall have a CRI of minimum 70. The fixture shall be designed for a sysytem life of 50000 hours @ 70 % lumen maintenence , Ingress protection of IP 66 (lamp and gear compartment ) and Mechanical impact resistance ratinfg of IK>=07. The fixture driver should have an operating voltage range of 120-277V, surge protection of internal 4 KV amd external surge protection of 10 KV, PF.0.95, THD<10%. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india .LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters including complete electrical connection with fixing arrangenment on pole or wall and taking down unsv light fittings complete all as specified and directed by Engr-in-Charge . Make : Bajaj Cat part No -/Wipro/ /Philips
Supply & Fix IP65 rated LED Post Top light fittings 40 watt with moonlight effect and efficient light distribution complete with electrical connection arrangement
Supply and fixing Junction box made of SMC/FRP sheet ready made of size 300 mm x 200 x 105 mm having 100 A Capacity RYB and neutral aluminium bus bar of 3 mm thick duly fitted on suitable insulator, and MCB SP 6 A 10 KA 240V -01 No. with fixing arrangement fixed properly to pole/fixed on wall with MS Clamps 25x5 mm and nut and bolts complete all as specified and directed by the Engineer-In-Charge.
Supply & Fix street light brackets fabricated out of medium grade GI pipe of 50 mm dia, 1.5mtr long bent to shape suitable for street light fittings with two sets of clamps made out of mild steel flat iron suitable for fixing on HT/LT poles with nuts, bolts and washers all as directed including dismantling the existing brackets etc complete all as directed.
S & F in repair MCB TPN 16- 32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified Make Legrand Cat no 40860 or equivalent I ABB / Siemens
S & F in repair MCB SPN 6-32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified Make Legrand Cat no 408609 to 408617 or equivalent I ABB / Siemens
S & F in repair MCB SP 6-32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified Make Legrand Cat no 408609 to 408617 or equivalent I ABB / Siemens
S & L cable XLPE insulated screened PVC bedded galvanized steel striper wire armoured electric power cables heavy duty with standard aluminium conductor,1100 volts grade,cross sectional area 3.5 core 50 Sqmm .Note : Excavation, returning and refilling will be measured and paid separately.
All as per item above but 35 Sqmm 3.5 core
All as per item above but 25 Sqmm 4 core
All as per item above but 16 Sqmm 4 core
All as per item above but 10 Sqmm 4 core
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3m in depth for foundation, etc or not exceeding 10 Sqm on plan and exceeding 1.5m but not exceeding 3m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass complete.
Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete.
Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete.
Sand cushioning with fine dry unwashed sand in trenches for protection of cables complete.
Old size sub class ‘B’ bricks, laid in trenches as cable covers complete (Note :- old serviceable will be reuse)
Dismantling of Concrete Poles/Struuts,any size and removing the same from site out side of MOD land complete all as specified and directed. Note:-The item are not reuse in side and carrying to credit.
Supply and fixing steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-31 (9 meter long) complete, Including disconnecting and taking out old damage PCC pole all as directed .
M&L for Aluminium conductor, steel reinforced of any size on LT Poles including straining,binding with insulators with Al/copper binding wire with insulators as in over head conductors, providing PVC Sleeves for jumper fixed as in repairs, complete all as specified and directed.
Taking down service wire from street light poles & providing new 1100 V Grade PVC insulated,aluminium conductor & overall PVC sheathed in service connection with 2 single core cables of size 6 Sqmm & connecting to light fittings/tertminal boxes
Taking down service wire from street light poles & providing new 1100 V Grade PVC insulated,aluminium conductor & overall PVC sheathed in service connection with 2 single core cables of size 10 Sqmm & connecting to light fittings/tertminal boxes
Repair, servicing and comprehensive/ preventive maintenance of Engine part of DG set any make of Capacities 40KVA to 63 KVA, which include removal unserviceable worn out spare parts, cleaning of all components with necessary cleaning material, replacement of all spare parts and gaskets as per manufacturer spare part kit, engine oil change including overhauling, re-assembling of complete engine setting, timing setting, bleaching and engine testing, replacement of diesel filter,Engine oil filter, lubricating oil, rubber hose pipe, V belt, oil pipe, diesel pipe, repair kit, burnt oil part etc. and tightening of nuts bolts, washers greasing etc for proper running of DG sets all as directed at site complete. Note (i) Spares part, engine oil, fillters shall be measured and paid for separately. (ii) Cost of oiling, greasing, tightening of nuts, bolts and minor work etc are included in the unit rate quoted by the contractor.
Material & labour for replacement of Engine oil 20 W 40 during servicing of DG sets.
Supply and fix in replacement of Engine oil filter for DG set upto 63 KVA capacity.
Supply and fix in replacement of Diesel filter for DG set upto 63 KVA capacity.
Supply and fix in replacement of Air filter for DG set upto 63 KVA capacity.
Supply and fix in replacement of unserviceable fuel pipe for DG set upto 63 KVA capacity.
Supply and fixing in replacement of asbestos rope any dia wrapped over the exhaust pipe complete
Repair and overhauling of self starter 12 V/ 24 V of DG set, upto 63 KVA Capacity, after opening nuts and bolts complete carrying out repair/ maint work for smooth functioning, testing complete and refixed same place as directed at site. Note :- (i) (Spare parts will be measured and paid separately)
Supply and fix in replacement of unsv Field Coil to self starter 12V/24V of DG set upto 63 KVA complete.
Supply and fix in replacement of unsv Armature winding to self starter 12V/24V of DG set upto 63 KVA complete.
Supply and fix in replacement of unsv Clutch assembly to self starter 12V/24V of DG set upto 63 KVA complete
Supply and fix in replacement of unsv Carbon Brushes to self starter 12V/24V of DG set upto 63 KVA complete
Supply and fix in replacement of Pinion Assembly to self starter 12V/24V of DG set upto 63 KVA complete
Repair and overhauling of dynamo of any DG set, upto 63 KVA capacity after opening nuts and bolts complete carrying out repair/ maint work for smooth functioning, testing complete and refixed same place as directed at site. Note :- (i) (Spare parts will be measured and paid separately).
Supply and fix in replacement of unsv Carbon Brushes to Dynmo of DG set upto 63 KVA complete
M & L for Armature rewinding to Dynmo of DG set upto 63 KVA complete
Supply and fix in replacement of unsv Field Coil to Dynmo of DG set upto 63 KVA complete
Disconnecting and dismantalling the alternator unit of DG Set from the base plate of the DG set and transporting the workshop for repair, dismantaling the unit , further seperation the armature from the startor carefully, cutting and taking out the burnt winding of the alternator carefully, cleanning the slot and duly applying the insulation and assembling the stampings inserting the positiion in the startor incl applying slot insulation and rewinding of the alternator startor winding with super enameled copper conductor of the same gauge and the same number of turns as that of existing one including replacement of carbon brushes tapping the winding and bring out the coil conncetion for production of three phase 415 V 50 HZ AC supply preheating the winding and applying insulating warnish and drying the winding in oven and assembling the unit and transporting back to insatallation and fix on base plate and coupling with the DG set and testing complte all as specified and directed (a) 40 KVA
Repair/maintenance of DG set Manual/AMF LT Panel by cleaning of all carbonized / corroded parts, checking of wiring and battery charging system if any in the panel replacement of lugs, single core copper cable 2.5 /4 Sqmm etc as required and making the panel serviceable of any size / any make including replacement of voltmeter, ammeter, power factor meter, indicator frequency meter etc all as directed by Engineer-in-Charge Note :- (i) (Spare parts like Voltmeter, Ammeter,Power Factor meter, Indicator lamp, Frequency Meter and MCB/MCCB will be measured and paid separately). (ii) Cost of Lugs, tightening of nuts, bolts replacement of wiring and other minor work etc are included in the unit rate quoted by the contractor.
Supply and fix in replacement of unsv Voltmeter, range 0 to 500 V into LT Panel of DG set upto 63 KVA complete
Supply and fix in replacement of unsv Ammeter, as per existing type or model into LT Panel of DG set upto 63 KVA complete
Supply and fix in replacement of unsv Frequency meter, as per existing type or model into LT Panel of DG set upto 63 KVA complete
Supply and fix in replacement of unsv Power Factor meter, as per existing type or model into LT Panel of DG set upto 63 KVA complete
Supply and fix in replacement of unsv Indicator Lamp RYB, as per existing type or model into LT Panel of DG set upto 63 KVA complete
Supply and fix in replacement of unsv MCCB TP 63 Amps adjustable thermal and fixed magnetic ,16 KA, 415 volts complete in LT Panel of DG set upto 63 KVA complete
Supply and fix in replacement of unsv MCCB TP 100 Amps ,adjustable thermal and fixed magnetic ,16 KA, 415 volts complete in LT Panel of DG set upto 63 KVA complete
Supply and fixing of battery terminal bolt type suitable for 180 AH battery as directed by Engineer-in-Charge.
Supply and fixing battery lead of copper conductor 25 Sqmm single core fitted with lead terminal on one side and other side with brass or lead terminal ( length of wire not less than1.5 Mtrs) as per site required and connection as directed by Engineer-in-Charge
Supply and fix in replcement of unserviceable battery 12 Volts.150 AH including filling of required capacity electrolyte and transportation complete all as directed by Engineer-in-Charge.
Supply and fix in replcement of unserviceable battery 12 Volts.180 AH including filling of required capacity electrolyte and transportation complete all as directed by Engineer-in-Charge.
Supply and fill electrolyte distiled water to battery complete all as directed by Engineer-in-Charge.
Taking out injection nozzle from DG set transportation to authorised service centre for repairing and replacement of necessary parts calibration and re-fixing to DG set and testing complete all as directed by Engineer-in-Charge.
Material and Labour for servicing and overhauling and repairing complete alternator greasing cleaning of all stator and rotor, re-varnishing the stator and rotor winding with superior quality of varnish including heating and baking the same. Re-assembling the complete alternator, fixing in position and testing on load for the DG Set upto 63 KVA capacity Note :-(i) Cost of greasing, varnish, tightening of nuts, bolts replacement of wiring and other minor work etc are included in the unit rate quoted by the contractor.
Supply & Fixing in replacement MCCB 4 pole 160 amps 50Hz 415 volts adjustable type with reputing cap 25KA Make Havells
Supply & Fixing in replacement MCCB 4 pole 250 amps 50Hz 415 volts adjustable type with reputing cap 36KA Make Havells
S &F on load Change Over switch side handle operated 415 V 4 pole of capacity 160 amps Make Indo Asian Cat No ICAS0160 /HPL/L&T/Havells
S &F on load Change Over switch side handle operated 415 V 4 pole of capacity 100 amps Make Indo Asian Cat No ICAS0100 /HPL/L&T/Havells
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25M deep below natural ground level ) with top edge of plate not less than 1.5M below normal ground level, surrounded from all sides alternate packed layer of char coal dust and comman salt and electrode connected with galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR part I including necessary earth work in type strata, foundation of pit and wall using PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate 40 mm thick pit cover slab using RCC 1:2:4 type B0 using 12.50 mm graded crushed stone aggregate with 6 mm dia MS bar @ 100 mm C/C both ways GI medium grade 20 mm dia pipe for watering including funnel with wire mesh and 15 mm bore GI light grade pipe for earth lead wire protection up tp 7.5 mtr complete all as directed including testing complete on completion.
-Ditto- all as per sl item above above but using 32x6 mm GI earth strip as a earth lead & 40 mm dia light grade GI protection pipe complete all as specified & directed Note (i) GI wire/strip or protection pipe 15mm/40mm dia upto 7.5 RM included the quoted rate. (ii) The qty above the 7.5 RM shall be measured & paid separetely
Cleaning of over head water tank by draining out water from the tank, removing sludge, mud or any other foregin materials from the bottom and internal surface and cleaning by wire brushing, washing internally by using bleaching powder and applying 2 coats of lime washing including re writing the date of cleaning, capacity of the tank with white paint on black back ground & external painting applying two coat of cement base paint including painting of steel and iron surface like railings and CI pipe line etc (welding to steel railing / ladder if required) with two coats of synthetic enamel paint over a coat of primer etc complete for the following capacities all as directed by Engineer-in- Charge. 50000 gallons at 18m staging.
100000 gallons at 18m staging.
Material & labour for Pumping out liquid and Taking out setteled sewage sludge/silt from STP Screening Bed & Sewage Collection Chamber, with the help of sewage suction pump and transporting & Disposed off the material minimum 5 KM away from the site to a low lying area (Isolated/No man area) and covering with a layer of soil but not less than 25 cm thick as directed.
Material & labour for Pumping out liquid and Taking out setteled sewage sludge/silt from STP, Clarifire Chamber 01 & 02, sludge digester and reaction room complete, with the help of sewage suction pump and transporting & Disposed off the material minimum 5 KM away from the site to a low lying area (Isolated/No man area) and covering with a layer of soil but not less than 25 cm thick as directed.
Cleaning of STP, Clean water semi under ground sump (Ecko Lake) by draining out water from the sump with portable pump sets, removing sludge, mud or any other foregin materials from the bottom and cleaning internal surface by wire brushing, washing internally by using bleaching powder and applying 2 coats of lime washing including painting with cement base paint internal & external wall surface etc complete. Note for item No. 01 to 04 :- (i) T&P required for cleaning the OHT/Sewage water tank shall be provided by the contractor. (ii) Necessary safety precautions for workmen shall be the responsibility of the contractor.
Supply and filling PP Floating media to top up the Bio reactors as per existing complete.
Surface excavation not exceeding 30 cm deep and average 15 cm deep and getting out for lifting/ taking out of sludge/silt accumulated inside drying sludge bed of 1-06 Nos bed of size 9.0x9.0x1.2 M, making necessary arrangements and disposal of the same to the out side of 213 Transit Camp Jammu complete all as specified and directed by Engineer in charge
Cleaning of over service water tank of PVC/RCC and the connected circulating pipes at any position by removing dirt, sludge, mud, moss, moulds,efflorescent salts, oil spots etc or any other foreign materials from the bottom, cover and internal surface by scrapping using wire brush, draining out the washed water from the tank and washing internally by using bleaching powder and again draining out the water from the tank and applying 02 coats of lime wash and re writting the date of cleaning, with white paint on black back ground for the following capacities all as directed by Engineer-in-Charge. Not exceeding 500 litre.
Exceeding 500 litre but not exceeeding 1000 litre.
Exceeding 1000 litre but not exceeeding 2000 litre.
Material & Labour for repairing the water leakage of inlet pipe and connected to float valve of RCC/PVC service tanks by removing sort piece of pipe / barrel nipple and replace with suitable barrel nipple, socket, elbow and arrest the water leakage by using the water proofing material.
Supply & Fixed ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed in repairs for the following sizes. 25 mm dia.
20 mm dia.
15 mm dia.
Supply and mix bleaching powder stable Gde-I confrming to IS specification 1665/89 ( second revision ) minimum available chlorine percentage by mass 34%+1% in 25 Kg polythene HDPE bags duly marked date of manufacturing and batch No. of fresh lot. Make Vikram SBP brand of M/S Grasim industries LTD/M/s Rayalaseema Hi strength Hypo ltd?DCM Shriram ltd oer equivalent make approved by E-in-C's Br. Note : The contractor shall deliver the same as per the site requirement and direction of nEngineer-in-charge
Supply and mix calcium Hypo Chloride granular in factory sealed HDPE container ( 45 kg Each) decomposing at 177C, Mol Wt:142.98, Toxicity : Oral rat LD : 850 mg/kg having chlorination concentration level 70 %Make- Puri chlor (Sree Rayalaseema Hi- strength Hypo Ltd) of equivalent make as per approved by engineer-in-Charge (E-in-C's branch approved only)
M&L for clinning of MES electric supply insatllation/Campus/ Water supply installation, Over tank Four pole structure by surface dressing or trimming of natural ground to remove small un equilities not exc 15 cm deep (incuding removing vegetation including shrubs /brushwood /undergrowth etc) carrying away the rubbish to a distance of not exc 15 mtr away complete.
Supply and fixing in repairs earth continuity conductor or main earthing lead fixed to walls on batten or recess or chesses or buried in ground or fixed to poles , OHT or any other indicated situation for loop earthing with using 32 x 6 mm dia GI strip, complete all as specified and directed.
S&F in repairs12 mm dia and 300 mm long air termination, single pointed aluminium rod , complete all as specified and directed.
S&F Aviation obstraction light of dia cast aluminum housing with red polycarbonate dome for better illumination integral driver super flux 5mm 302 nos LEDs incorporated protection against surge 80 % energy saves and longer life time 50000 Hrs . IP 65 50Hz 240 V on Over head tanks complete all as specified and directed by Engr-in- Charge.
Nitika electricals and engineers works
M/S RAJ ENGINEERS
M/S DC CONSTRUCTIONS
M/S ANMOL TRADING CO
proach associates
SHSS ASSOCIATES
Bidder Name
proach associates
Nitika electricals and engineers works
MAMTA ENTERPRISES
M/S RAJ ENGINEERS
M/S ANMOL TRADING CO
SHSS ASSOCIATES
M/S DC CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .