Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.0 L+₹1.0 L (3.64%)Rejected-AOC | L2 | Rejected-AOC Being L2 | |
| 3 | L3₹29.6 L+₹1.6 L (5.81%)Rejected-Finance 141 1 ARYAPALLY NORTH BARANILPUR PURBA BARDHAMAN | BARANILPUR | PURBA BARDHAMAN | WEST BENGAL | L3 | Rejected-Finance Being L3 |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
2 Jul 2025, 2:00 pmClosed
Executive Engineer, Bardhaman Electrical Division,
Purta Bhavan, 1st Floor, Purba Bardhaman
Construction of Proposed Boys Hostel (Gplus4) at Tetultala Wakf Estate, Dist Purba Bardhaman- Security Lighting System, SITC of AC System, SITC of Lighting Arrester System, SITC of DG Set, SITC LED Signage and SITC of Solar PV System
2025_WBPWD_866954_1
WBPWD/EEBED/NIQ-03/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
25 days
Purba Bardhaman
Please refer Tender documents.
4 documents required · 4 mandatory
₹56,000
28 Nov 2025
19 Jun 2025
4 Jul 2025
19 Jun 2025
2 Jul 2025
19 Jun 2025
Amount
Supply and Delivery of 1100V grade 2Core 10sq mm XLPE insulated armour alluminium cable as per IS 7098(Part 1).(Make:-R R Kabel / Polycab / Havells).
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [F-1/2a]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry and Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials ( F4/7a + F5/8b)
Supplying & Fixing sheet steel GI box (16 SWG) on wall for timer DB of suitable size with fixing following materials for compound light operation : i) DP MCB (16A)(LK) ii) Toggle Switch iii) SP MCB (6-32A) (LK) 2 Nos iv) Three Pole Power Contactor (25 A)(L &T) v) Time Switch (Digital Timer GIC 67DDT0) vi) Require Copper wire,terminals,push button,indicator, Neutral terminal etc (Ph,N &E)
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. [C-3/18]
S & D of 70 Watt Street Light fittings with alluminium diacast,4KV SPD, IP65 lumen output 100 lm/w. ( Make-Philips-BRP032 LED70 CW MR PSU GR DX or equivalent of it in all respect for Crompton / Wipro) .
Supplying and Drawing 1.1 KV 3 X1.5sqmm single core stranded 'FR' PVC insulated & unsheathed copper wire ( Mk. Polycab / Havells / RR Kabel) in the 13 mm dia 3 mm thick polythene pipe embedded in wall from loop box to light fittings incl connection and both end socketing as to G S. (E2/5a+E9/1b)
Supplying & Fixing G I sheet waterproof type looping cable box flushed inside wall of size 200 x 150 x 100 mm deep having 4 mm thick comprising of one 250 V 6 A SP MCB unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on outside, etc. including connection [For area lighting]
Supply and Delivery of Inverter type Split type AC machines having Cooling Capacity range (6.6 kw -7.0 kw) with rotary compressor, refrigerant gas R32/R410 BEE star rating 3 (EER range 3.5 to 3.99), Air flow range CFM (780-850), Operating Outdoor Temparature = 50°C and above, Power Supply -240V,50Hz [(+)Tolerrance as per applicable standard ], both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments (Make- Mitsubishi Electric/O-General/ Mitusubishi Heavy) Split AC must be following essential requirement i) Indoor PCB unit must be within a metal enclosure as per CEWE order. ii) Comprehensive Warranty: 1 year & additional 5 years on Compressor.
Supply and Delivery of Split type AC machines having Cooling Capacity range (5.2 kw -5.3 kw) with rotary compressor, refrigerant gas R32/R410 BEE star rating 3 (EER range 3.5 to 3.99), Air flow range CFM (560-600), Operating Outdoor Temparature = 50°C and above, Power Supply -240V,50Hz [(+)Tolerrance as per applicable standard ], both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments (Make- Mitsubishi Electric/O-General/ Mitusubishi Heavy) Split AC must be following essential requirement i) Indoor PCB unit must be within a metal enclosure as per CEWE order. iii) Comprehensive Warranty: 1 year & additional 5 years on Compressor.
Supply and Delivery of Inverter type Split AC machines having Cooling Capacity range (3.3 kw - 3.6 kw) with rotary compressor, refrigerant gas R32/R410 BEE star rating 3 (EER range 3.5 to 3.99), Air flow range CFM (340-400), Operating Outdoor Temparature = 50°C and above, Power Supply -240V,50Hz [(+)Tolerrance as per applicable standard ], both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments (Make- Mitsubishi Electric / O-General / Mitusubishi Heavy) Split AC must be following essential requirement i) Indoor PCB unit must be within a metal enclosure as per CEWE order. ii) Comprehensive Warranty: 1 year & additional 5 years on Compressor.
Inatallation,Testing and Commissioning charges after supply and fixing of iron Angle braket for fixing the outdoor unit of AC machines including charging refrigerant Gas (R32/R410A) charging for above Split Air Conditioner.
S/F of 25A AC starter with 20A DP MCB with suitable G I Box modular type flushed in wall inclk mending good the damages (Make:-North west or similar model of Anchor / Cabtree)
S/F 20A plug top on existing wires incl connections. (Make:-North west or similar model of Anchor / Cabtree)
S/F 20A 3 pin Plug socket Modular type(Mk. Anchor Roma/Cabtree/Schneider) with 2 Module G I box flushed in wall incl mending Good the damages . E17/5a
SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft/hard drawn copper refrigerent piping for package/VRV/VRF/RAC system, complete with fittings, with adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XLPE Class - O tubular insulation / with Class - O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specification etc. as required. a) Liquid Line(1/4"OD with 0.6 mm thick) (Make: Godrej/ Carrier /Total Line/ MI Copper)
a) Liquid Line(1/2"OD with 0.6 mm thick) (Make: Godrej/ Carrier /Total Line/ MI Copper)
b) Suction line(5/8"OD with 0.7mm thick) (Make: Godrej/ Carrier/Total Line/ MI Copper)
Supply & laying PVC braided heavy duty Drain Pipe 20 mm dia incl. All accessories, and supporting clamps, as per direction of EIC.(Mk. As per approval)
Supply and Fixing of 1.1 KV grade 3 Core 4 Sq.mm 1.1KV grade "FR" Unarmoured Cu cable for OLP/Starter to ODU .Termination points must be socket with Cu ring/pin type socket as per requirement. (Make- GLOSTER/KEI/ Polycab/ RR kabel)
Supply & Fixing 4 core 2.5 sq.mm. 1.1kV "FR" PVC unarmoured cable for connection between indoor to outdoor unit.Termination points must be socket with Cu ring/pin type socket as per requirement (Mk. Havells / KEI / Polycab / RR Kabel)
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. 10 SWG (G-2/5 iv)
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.(G-2/4a)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:ByISI-Medium GI pipe. incl excavation of earth soil soft soil. [G-1:/1/a +2/a]
S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1) [J-1/1]
S & F of 4 SWG GI (Hot Dip) wire on Parapet /Roof /Plinth /Surface of wall for lightning conductor as required (for Horizontal runs) with 40 mm long GI Staples spaced not exceeding 1300 mm apart incl. mending good all the damages to the building works [J-1/2]
S & F of 4 SWG GI (Hot Dip) wire on wall for the lightning conductor as required (for vertical run) with GI Staples (40 mm long) spaced not exceeding 1 Mtr. apart incl. mending good the damages to building works (excluding hire charges of scaffolding) [J-1/3]
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works: Length upto 0.5 Mtr. [J-1/4a]
Making soldered joints between conductors, conductors and air terminals for 4 SWG GI (Hot Dip) wire incl. supply of jointing materials and painting with 2 (two) coats of bituminous paint. [J -1/5]
Making soldered joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint. [J-1/6]
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run. [J-1/7]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:ByISI-Medium GI pipe [G-1:2a]
Excavation of soil for installation of Earth Electrode and filling & ramming. for Soft Soil [G-1/1b]
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required.[J-2/13]
SITC with C C foundation of 40 kVA, 415V, 50Hz, 3 Phase silent new DG Set incl. full tank HSD oil, comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB-IV approved Engine & Acoustic Enclosure having following specifications (ISO-8528 Part-IV) having following specifications :- ENGINE: Make : Make :-Cummins/Ashok Layland/Greaves Power/Kirloskar Engine Type : 4 Stroke Diesel Engine Engine ambient temparature : 52 deg C. Engine & Alternator protection should be from same DG set controller. RPM : 1500 MoEF Certified Power (hp): 52 BHP Duty : PRIME Cooling : Liquid Cooled (EG Compleat 50:50) Cylinder : 4 Aspiration : Turbo Charged after cooled Type of Governer : Electronic Fuel Tank Capacity : Minimum capacity 140Ltrs. a. Fuel Consumption at 75% rated Load with Radiator or Fan : 11 Ltr./ Hr. or Less b.Fuel Consumption at 100% rated Load with Radiator or Fan : 14.29Ltr./ Hr. or Less Overload Capacity : 10% overload for one hour for every 11 hours continious running full load or better Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter. Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator. Exhaust Silencer : Residential Type
(iii) All materials, equipments & accessories must conform to relavent IS specifications (iv) Nacessary manufacturer's test certificate for Desiel Engin, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment. (v) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competant Authority (As per CPCB-IV). (vi) Circuit Diagram for AMF Panel must be submited from the Manufacturer/OEM. (vii) The entire set must be warranted atleast 15 months from the date of Delivery/12 months or 5000 Hrs running from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs running, whichever is earlier.
The above D G set should be placed on suitable size foundation block CC structure with 150 mm RCC top slab of size 3000 mm X 1500 mm X 1200 mm Height ( 600 above GL )with plastered and net cement finish & net guard fencing arrangement.
Providing D G shed of size suitable for covering above 40 KVA D G set by Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (including the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm thick . washer etc. complete with 150 mm end lapa and one corrugation minimum side lap with M.S. structural works with 6 Nos M S pillars ( 3" X 3 " square bar of length 12 ft 3.2 mm thick 6.71 kg per mtr) and roof trusses with tubular sections ( 32 mm X 32 mm square bar 2.6 mm 2.26 kg per mtr ) conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The side portion of this sheded room is protected by MS wire net mesh ( 1" X 1" square net of 10 SWG wire) with suitable supporting M S bar or MS angle with 1 No opening ( 4 ft X 7 ft height ) door with locking arrangement incl all painting ( The dimention of this room / shed is 4000 mm X 3500 mm X height 3000 mm ) The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S &F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level By ISI-Medium GI pipe [ G-1 / 2 (a) ]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. (G-2/ 4a)
Supply of 4 core 25sqmm size 1.1 kV (1100V) grade, XLPE/PVC insulated, Armoured Al. LT cable As Per IS-7098 (Part 1)/ 1554 (Part 1):1988 with up to date amendments as applicable. (Make:- RR Kabel /PolyCab /Gloster / Havells /KEI)
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed(F-2/1a)
Supplying & fixing of 50 mm dia medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required (F-6/11d)
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core (F-1/3a)
Supplying and fixing of 4core 50sqmm compression type gland and solderless socket (Dowels make)complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables Finishing the end . ( F4/7c + F58 (b) (xvi)
Supply & making of 3" exhaust pipe line completed with m.s pipe, bend, flange, gasket etc with Thermal Insulation complete with Mineral Wool 50 mm Thick wire mesh and 26 gauge aluminium cladding on 3" pipe
Supply & making of Thermal Insulation complete with Mineral Wool 50 mm Thick wire mesh and 26 gauge aluminium cladding on Silencer box
Supply & laying of 1.1 KV grade 12 core 2.5 sq.mm. PVC copper conductor control cable partly by shaddle on wall and partly in under ground trench to interconnect DG set with AMF panel.
in under ground trench with 32 mm da G I pipe
by saddle and screw on wall
Supply & laying 1 x 50 sq. mm. single core flexible copper wire in suitable size PVC pipe (reinforced) on wall / floor from neutral earth bus to DG set neutral point including both side socketing.
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Supply & fixing black PVC heat shrink sleeve for covering the 25 x 6 mm. GI flat.
Supply & fixing of m.s Angle iron support for holding the MS Pipe with vertical structure by grouting the clamp on wall after making the hole on wall and fixing the clamp by conctreate marter and mending good damage.
Supply & fixing of rain cap.
Supply & fixing of oil pump
Supply and Delivery of HSD Oil for DG Set
Sign Board : Supply & Installation of suitable depth box type M.S. structure duly fabricated & welded by 40 mm x 40 mm x 12 SWG M.S. square holow bar (ISI mark) frame with back side & four sides covered by 24SWG GI sheet including Aluminum channel and fixing arrangement with out ACP sheet including painting. size : 20' x 4' to be made such a manner that it can be opened for taking maintenance. S&F 4 mm thick "Blue" Colour ACP sheet on MS structure. Size 20 ft. X 4 ft. Supply fixing of LED inside the acrylic letters. The specification of the LED is given below : A) LED: White- Samsung SMD 5630 (Korea) module: B) Type: Double line fixed C) Life: 70,000 burning hours D) Intensity: Same & smooth throughtout, no brighter or light or dark patches. E) Visibility: 50 mtr. at least for normal eye. F) Power supply: Required AMP (meanwell LRS-<...>-12) G) Ambient Air: 0-50C.100% relative humidity. H) Power Consumption: 1.08 watt per module. Supply & Fixing of special type imported acrylic letter required height fixed on ACP sheet. The letter font (English & Bengali, Bold) Letter colour = White. Encrypted with : "…….........................................................." NB. AS PER REQUIREMENT & APPROVAL FROM AUTHORITY END. S & F water proof 750 watt power supply system IP65, 50/60Hz frequency, 108 to 305 V AC powersupply, >.095 power factor for LED lamp. (Make : Meanwell / Groen / Impex) -
Fixing the above glow sign board on wall 20 ft height from G L by means of MS fabricated frame made from 40 x 40 x 5mm M.S. Angle in rectangular shape of size 20' x 4' rigidly fixed on wall by grouting 6 nos MS leg incl. painting complete. Angle iron legs as suitable length & quantity with fabrication & grouting complete with carrying charges.
Supply, Installation, Testing & Commissioning of 10 kwp Solar Photovoltaic Panels. Poly Crystalline 310Wp to 335Wp (Each) (Make: VIKRAM / WAREE / JINKO / SOVA/ ADANI/Tata BP) The PV modules of JAKSON make allowed used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards Crystalline Silicon Solar Cell Modules IEC 61215/IS14286 .The rated output power of any supplied module shall have tolerance of +/- 3%.The peak-power point voltage and the peak-power point current of any supplied module and/or any module string (series connected modules) shall not vary by more than 2 (two) per cent from the respective arithmetic means for all modules and/or for all module strings, as the case may be.The module shall be provided with a junction box with either provision of external screw terminal connection or sealed type and with arrangement for provision of by-pass diode. The box shall have hinged, weather proof lid with captive screws and cable gland entry points or may be of sealed type and IP-65 rated. Supply & Fixing Module Mounting Structure: Hot dip galvanized MS mounting structures may be used for mounting the 10kwp modules/ panels/arrays. Each structure should have angle of inclination as per the site conditions to take maximum insolation.The mounting structure steel shall be as per latest IS 2062: 1992 and galvanization of the mounting structure shall be in compliance of latest IS 4Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts.Thickness of Galvanization shall be more than 75µ. Aluminium structures also can be used which can withstand the wind speed of respective wind zone. Necessary protection towards rusting need to be provided either by coating or anodization.The minimum clearance of the structure from the roof level should be 300 mm [Design to be approved by EIC before fabrication].
Supply, Installation, Testing & Commissioning of 1 Nos. PV Array Junction Box of SURCLE & ENERTECH make for 10kwp: a) The junction boxes are to be provided in the PV array for termination of connecting cables. The Boxes (JBs) shall be made of Powder Coated Aluminium /cast aluminium/M.S alloy with full dust, water & vermin proof arrangement. All wires/cables must be terminated through cable lugs. The JBs shall be such that input & output termination can be made through suitable cable glands.b) Each Junction Box shall have High quality Suitable capacity Metal Oxide Varistors (MOVs) / SPDs, suitable Reverse Blocking Diodes. The Junction Boxes shall have suitable arrangement monitoring and disconnection for each of the groups. Voltage: Max. 1000V DC [Make: Hensel/Spielberg/Citel/ABB/L & T/schneider/Elmax]. Supply, Installation, Testing & Commissioning of ACDB : PV Array Junction Box ACDB of SURCLE & ENERTECH make Designed for 10kWp solar power plant with all protections as per MNRE guidelines. DC DPBs shall have sheet from enclosure of dust & vermin proof conform to IP 65 protection. The bus bars are made of copper of suitable size. Suitable capacity fuse & MCBs/MCCB shall be provided for controlling the DC power output to the PCU along with necessary surge arrestors . AC Distribution Panel Board (DPB) shall control the AC power from PCU/ inverter, and should have necessary surge arrestors. Interconnection from ACDB to mains at LT Bus bar while in grid tied mode.All switches and the circuit breakers, connectors should conform to IEC 60947, part I, II and III/ IS60947 part I, II and III. All the Panel’s shall be metal clad, totally enclosed, rigid, floor mounted, air - insulated, cubical type suitable for operation on three phase / single phase, 415 or 230 volts, 50 Hz.All indoor panels will have protection of IP54 or better. All outdoor panels will have protection of IP65 or better. [Make:Hensel/Spielberg/Citel/ ABB/L& T/schneider/Elmax]
Supply, Installation, Testing & Commissioning of ongrid Solar Inverter with load islanding protection facility Rating: 10kw, 1Ph Inverter, Make: HBL / INVT/ Power-One/Kako/Havells. Control : Microprocessor /DSP Capacity .Nominal AC output voltage and frequency : 220V, 1 Phase , 50 Hz . Output frequency : 50 Hz . Max. DC input Power 10kW. MPPT Voltage Range should be 165 – 260V. Output Voltage Range - 220V AC. Grid Frequency Synchronization range : +/- 5 Hz. Ambient temperature considered : -20o C to 60o C. Humidity : 95 % Non-condensing. Protection of Enclosure :: should be IP 20 compatible to IEC 60529 : 2001-02- As per MNRE requirment. Grid Frequency Tolerance range : +/- 5 Hz. Grid Voltage tolerance : 180 V to 260 V. No-load losses : Less than 1% of rated power. Inverter efficiency(minimum) : >93%. Inverter efficiency (minimum ) : > 90%. THD : < 3%. Efficiency Measurement IEC 61683/ Equivalent BIS Std.Environmental testing IEC 60068-2 (1,2,14,30) / Equivalent BIS Std.Interfacing with utility grid IEC 61727. Islanding Prevention Measurement IEC 62116. EMI/EMC : IEC 61000-6-3>16 Amps IEC 61000-6-4<16 Amps. Safety: IEC - 62109-1 (2010/4) C - 62109-2 (2011/6).Battery VDC: 120VDC/192/VDC. Charger Capacity: 40A. (Protections) Over Load For 100% Load Buzzer Indication, 101% above Load Trips and Retry for 4times then Inverter shutdown, Output Short Circuit:Circuit Breaker On Mains, Shutdown on Inverter,Battery Reverse Protection: Circuit Breaker, Low Battery:Load Disconnection, Thermal Shutdown:Below 0°C and Above. PCU Brand ENERTECH / STATCON allowed
Supply and laying required size of armoured PVC/XLPE Power cable on wall for Grid connectivity. 2 core 16 sq.mm Al unarmoured cable (multistrended)
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision with 40A FP MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment
Distribution wiring in 1.1Kv single core stranded FR PVC insutlted & unsheathed copper wire (Polycab/Finolex/KEI) in 25mm bore 3mm thick PVC rigid conduit pipe (Make Precision) on wall :- (For AC power supply from Inverter to AC distribution board to Panel) a) 4 x 10 sq.mm. + 2x6 sq.mm
b) 4 x 35 sq.mm.
Supplying and fixing 415V, 100A TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
S&F of Busbar Chamber with HRC fuse with 3 nos 415V, 100A HRC fuse (Busbar Type) by means of flat iron frame wall incl connection of wires. (Make: Benlo)
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages 10SWG
Rates to be quoted will be inclusive of all the taxes incl. GST. No other additional charges will be applicable in addition to the quoted rates.
M/S KALIMATA ENTERPRISE (BID ID -6644621)
M/S. DAS ELECTRIC CO. (BID ID -6643790)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .