| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC BALSUA P O JHAKOLARI PATHANKOT PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC OK | |
| 2 | L2₹38.3 L+₹43,141.50 (1.14%)Rejected-Finance | L2 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹90,520
Closing Date
17 Sept 2020, 6:00 pmClosed
CWE Pathankot
HQ CWE Pathankot
SPECIAL REPAIR OF ROOF, ROOF TREATMENT, SIDE ROOM, REPLACEMENT OF SHUTTERS INCLUDING INTERNAL WIRING IN BLDG NO NP-43 UNDER GE (WEST) PATHANKOT
2020_MES_370882_1
CWE/P-60/2020-21
Open Tender
Civil Works
Item Rate
180 days
Pathankot
class D and above Category (a) (i)
9 documents required · 9 mandatory
₹500
Yes
GE (West) Pathankot
₹90,520
Yes
29 Oct 2020
20 Aug 2020
19 Sept 2020
20 Aug 2020
17 Sept 2020
3 Sept 2020
Amount
Dismantling of AC corrugated or semicorrugated sheets in roof including ridges etc complete all as specified. Note : The sheet will be dismantled at a height of 6.0m to 8.0m. The rate for necessary scaffolding, safety precautions , etc are deemed to be included in the quoted rates complete all as specified and directed.
Dismanting of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering complete all as specified. Note : The sheet will be dismantled at a height of 6.0m to 8.0m. The rate for necessary scaffolding, safety precautions , etc are deemed to be included in the quoted rates complete all as specified and directed.
S & F plain galvanised mild steel sheeting 1.00 mm thick, in ridges, hips, valley gutters, drip and straight flashings(length and girth as fixed) with grade of zinc coating 275 including welding or soldering at joints complete all as specified..
S & F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.60mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws / 'J' or 'L' type hook bolt with two nos of silicon washer complete all as specified. Note : The sheet will be fixed at a height of 6.0m to 8.0m. The rate for necessary scaffolding, safety precautions , etc are deemed to be included in the quoted rates complete all as specified and directed.
S & F pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.60mm thick suitably moulded for ridges of roof and similar work as directed by Engr-in-Charge of any colour having tensile strength of 550 Mpa fixed with self tapping screws / 'J' or 'L' type hook bolt with two nos of silicon washer complete all as specified. Note : The sheet will be fixed at a height of 6.0m to 8.0m. The rate for necessary scaffolding, safety precautions , etc are deemed to be included in the quoted rates complete all as specified and directed
S&F hand rails, rounded or other stock section or core for wooden hand -rail, straight portion, drilled and countrsunk for nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cuttings, tops to shapes, as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. and similar work conforming to Fe-410-0 or Fe-310-0 all as specified.
S&F Mild steel framed work such as as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 (Gde E-165) conforming all as specfied.
S&F mild steel plates (Plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-290 (Gde E-165) complete all as specified and directed by Engr- in - charge.
Demolition of stone slab and tiles laid, bedded of any description and thickness in floors, aprons etc laid , complete all as specified.
M & L machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete over and including screed bed or bedding layer 20 mm thick in cement mortar 1:6 complete all as specified.
M & L machine kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over including backing coat 10mm thick in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified.
Dismantling of floor hearth and wall tiling incl cement morter bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified.
M & L coloured Glazed ceramic tiles in vertical surfaces 450 x 350 x 7mm set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat in cement mortar 1:4 complete all as specified.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified.
S & F steel rolling shutters, with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complet, gear operated type with bevel gear box and crank handle, thickness of laths 1.25mm complete all as specified and directed.
S & F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified.
S & F ball bearing for rolling shutters complete all as specified.
M & L expanded metal of size 20 X 50 mm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members complete all as specified.
S & f framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete Fe 410-W (Gde-E-250) quality-A complete all as specified.
S & F mild steel, plain, black sheet 1.25mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified and as directed.
M & L for 75mm thick PCC 1:3:6 Type C-1 (using 20mm graded crushed stone aggregates) as in plinth protection, finished the surfaces even & fair, complete all as specified and as directed.
M & L for 50 mm thick PCC 1:2:4 type B1 using(20mm graded stone graded crushed aggregate )as in flooring complete all as specified and as directed. Note : Necessary framework required for PCC deemed to be included in the rate.
M & L for 30mm thick wearproof topping as specified (incorporating an approved metallic floor hardner), laid on concrete floors and pavings, and finished even and smooth (except metallic hardner) complete all as specified and as directed.
Supply only metallic floor hardner complete all as specified and as directed..
M & L for forming contraction (Dummy) joint 30mm deep x 10mm wide filled with sealing compound Grade 'A' complete all as specified and as directed..
Demolition of brick or stone masonry, in ground floors and paving not exceeding 15cm thickness, complete all as specified.
M & L brick work with sub class ‘B’ bricks burnt old size brick, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6, complete all as specified.
Taking down cement plaster on brick or concrete surfaces in any description etc incl raking out joints, hacking for key , scrubbing down with water complete all as specified and directed.
M & L 15mm thick cement plaster rendering in cement mortar 1:6 on fair faces of stone masnory/brick or concrete surfaces & finishing the surface even and smooth without using extra cement, complete all as specified.
M & L 5mm thick rendering in cement mortar 1:3 on fair faces of brick or concrete surfaces & finishing the surface even and smooth without using extra lime or cement, complete all as specified.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically described (reinforement cut as required to facilitate demolition), complete all as directed by Engineer-in-Charge.
M & L RCC (nominal mix) type B-1, (1:2:4) using 20 mm graded crushed stone aggregate as in beams, cantilevers lintel over 1.5 m long span and the like complete all as specified.
M & L for precast reinforcement cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate, in cover slabs( for manholes etc.)chulla hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar (1:6) complete all as specified and directed. (Reinforcement shall be measured and paid separately).
S & F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S & F mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S & F powder coated anodised aluminium frame for doors, windows, ventilators and partitions with one or more rebates including joining cleat for fixing etc. complete all as specified (mimimum thickness of powder coating 50 micron) complete all as specified and as directed..
S & F powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified
S & F sheet glass 4.8mm thick ordinary quality and glazing with anodized aluminium powder coated beads in squares of any size of pane all as specified or as directed.
S & F Taking down chowkats or frames with shutters (without taking off shutters from the frame) area exceeding 1.5Sqm and not exceeding 4Sqm each including taking out hold fast complete all as specified and directed.
S & F Taking down chowkats or frame with shutters (without taking off shutters from the frames) area not exceeding 1.5 Sqm each including taking out hold fast complete all as specified.
S & F Taking down shutters of any description exceeding 1sqm and not exceeding 2 sqm each, complete all as specified and directed.
S & F steel window/Ventilator factory made out of box type and shutter (double shutter) with sash bar made out of section using flash butt welding, hinges shall be provided to both shutters complete including all fittings grills (12mm sq bars), glazing (glass pane, plain 3mm thick) , guaging (GI wire mesh 0.56mm nominal dia of wire and average width of aperture 1.40mm) and two coat synthetic enamel paint over a coat of red oxide primer all as per drg No CEPZ/TD/245/01 Sh 1/1, CEPZ-TD/246/01 Sheet 1/2 and Sheet 2/2 all as specified and directed by Engr-in-Charge.
S&F flush shutter 40mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F mild steel butt hinges, medium weight, cold rolled,100mm long , complete all as specified.
Supply and fxing Mild steel barrel tower bolt ISI marked, stove enamelled black, with bright bolt of 200mm long, complete all as specified.
Supply and fxing Mild steel pressed handle ISI marked, oval type stove enamelled, black of size 150 mm, complete all as specified.
Supply and fxing Mild steel sliding door bolts, stove enameled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolts plate and two on staple plate, 300mm long, all as specified.
Hacking out old broken glass (any the size quality or description) from wooden or steel frames glazed all as specified and directed by Engr-in-charge.
S & F toughened laminated glass, 8.0 mm thick and glazing with metal beading (any type) in square of any size. Note : The glass will be replaced at a height of 6.0m to 8.0m. including necessary scaffolding, safety precautions, etc. complete all as specified and as directed. ( Bolts, nuts & washer nuts as required to be provided in metal beading deemed to be included in the quoted rates of contractor.)
M & L for preparation of new plastered surfaces of ceiling and apply three coat of white wash complete all as specified and as directed.
M & L for complete removal of existing treatment of ceiling and apply three coat of white wash complete all as specified and as directed.
M & L for preparation of new plaster surface of wall including cornices by brooming down with steel wire brushing etc, and applying two coats of oil bound distemper over and including 3 mm thick wall care putty complete all as specified.
M & L for complete removal of existing treatment of wall and applying two coats of oil bound distemper over and including 3mm thick wall care putty complete all as specified.
M & L for preparation of new plastered surfaces of wall and apply two coat of cement base paint over and including a coat of alkali resistant primer complete all as specified..
M & L for complete removal of existing treatment of wall and apply two coat of cement base paint over and including a coat of alkali resistant primer complete all as specified.
M & L for preparation of new/undecorated plastered surfaces of walls and applying three coat of white wash complete all as specified and as directed
Material and labour for complete removal of existing treatment up to any height and applying three coat of white wash on undercoated surfaces of wall complete all as specified and as directed
Material and labour for preparation of new wooden surfaces of any description over 10 centimetre width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed
Material and labour for preparation of old painted wooden surfaces of any description over 10 centimetre width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed
Material and labour for preparation of old painted steel and iron surfaces of any description over 10 centimetre width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed
M & L applying two coat of synthetic enamelled paint over a coat of red oxide on steel and iron surfaces of any description , not other wise described over 10 cm width or girth including preparation of new surfaces complete all as specified and as directed.
M & L applying two coats of synthetic enamel paint over a coat of red oxide on steel and iron surfaces of any description, n. exc10 cm width or girth including preparation of new surfaces complete all as specified and as directed.
Dismantling of brick tiles or terracing tiles, single layer on roofs complete all as specified and as directed.
Demolition of mud in roofs, any thickness, including plastering and leeping ( whether full thickness removed or only a part thereof) complete all as specified and as directed.
Removal of excavated soil (materials retrieved from Srl item No 66) to a distance exe 250 m but nexc 500m and depositing where directed at a level nexc 1.5m above the starting point complete all as specified and as directed
Demolition of cement concrete (unreinforced) of any description and in any other position not otherwise specifically provided for complete all as specified and as directed.
M & L PCC (1:2:4) Type B1 (using 20 mm graded crushed stone aggregates as in roofs kerbs, bands etc complete all as specified and as directed .
M & L 40mm thick plain cement concrete (1:2:4) type B1 using 20 mm graded agg as in padding course on roof to maintain proper slope complete all as specified and as directed.
M & L for rendering in two coat (one 15mm thick and second coat 10 mm thick with WPC on concrete surface of parapet/facia/chajjas/soffit of beam/slab and the like) in cement mortar 1:3 and finishing even and smooth without using extra cement with using WPC complete all as specified and as directed (Note:- WPC will be measured and paid separately)
Supply only liquid water proofing compound complete all as specified and as directed
M& L for (a) Cleaning of all foreign material such as fungus, mass, dust ,debris etc by brushing and dusting,washing down with water, sprinkle water on the surface and ensure water does not stand any where and making the roof surface levelled with 15 mm thick rendering in cement mortar (1:4) with water roofing compound (as per manufacturer's instructions) (b) Applying a coat of approved cold applied bituminous oil based primer (IS-3384) @0.30 litre/sqm complete all as specified and directed (c) Applying roof treatment on top of roof with APP modified membrane with non-woven polyster reinforcement (centre core) with thermal insulation of weight not less than 3.5 kg/sqm & thickness not less than 3mm, laid by torch application method with overlap 100 mm on length side and 100 mm on the width side as per manufacturer's instructions complete all as specified and directed by Engr –in Charge. (d) Finally painting the surface with bituminious aluminuium paint @ 100 gm/ Sqm complete all as specified and directed. Note: WPC shalll be measured and paid separetely.
M& L for (a) Cleaning of all foreign material such as fungus, mass, dust ,debris etc by brushing and dusting,washing down with water, sprinkle water on the surface and ensure water does not stand any where and making the roof surface levelled with 15 mm thick rendering in cement mortar (1:4) with water roofing compound (as per manufacturer's instructions) (b) Applying a coat of approved cold applied bituminous oil based primer (IS-3384) @0.30 litre/sqm complete all as specified and directed (c) Applying roof treatment on top of roof with APP modified membrane with non-woven polyster reinforcement (centre core) with thermal insulation, of weight not less than 3.5 Kg/Sqm & thickness not less than 3mm, laid by torch application method with overlap 100 mm on length side and 100 mm on width side as per manufacturer’s instructions. A coat of blown bitumen 85/25 @ 1.2 kg/sqm to be applied on top of memberane and blinding material such as sand shall be dusted in dry condition @ 0.5 to 1.0 kg/sqm over the bitumen complete all as specified and directed by Engr-in-Charge (Membrane and cold primer should be from same manufacturer) Note: WPC shalll be measured and paid separetely.
M & L for cement concrete tile of size 300 x 300 x 22 mm thick machine pressed; set, jointed and pointed in neat cement slurry with grey cement and no pigment on roof laid over and including 20mm thick screed bedding layer in cement mortar 1:4 with a gap of 3mm thick and gap will be filled with neat cement slurry complete all as specified and as directed by Engr-in-Charge.
Demolition or breaking up drain pipe (salt glazed ware, AC, PVC or reinforcement concrete) of 150mm internal dia any dia set in cement mortar concrete complete all as specified.
M & L 150 mm bore salt glazed stone ware drain pipes, grade ‘A’ laid and jointed as specified and all as directed by Engr-in-Charge.
M & L for unplasticisted PVC drainage pipe 200mm dia type 'B' with wall thickness 4mm (min) of pressure rating 4KN/Sqm fixed to wall and jointed with cement solvent including testing complete all as specified and directed.
M & L for unplasticisted PVC bend 160mm dia type 'B' with wall thickness 4mm (min) of pressure rating 4KN/Sqm and jointed with cement solvent including testing complete all as specified and directed.
M & L for cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, superficial area exc 400 sq.cm but n exc 0.10 sqm, complete all as specified and directed.
M & L for cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, depth of embeded portion of holdfasts or lugs measured from the face of the jamb into the wall exc one brick but not exc two bricks, complete all as specified and directed..
S & F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 15 cm and n exc 22.5 cm long, dia of neck 16 to 20 mm complete all as specified and directed..
M & L vitreous china Wash hand basin, white, flat back of size 550x400mm including brackets, brass chromium plated waste coupling, and waste pipe dia including cutting for and pinning in ends of brackets or erecting stand etc, complete all as specified.
M&L PVC connection 15mm size with PTMT nuts on both ends of length 450mm , complete all as specified.
Supply and fixed in repairs Pillar taps fancy type cast copper alloy chromium plated with capstan head without letter Hot or Cold water screwed down for 15 mm dia iron pipe complete all as specified and directed..
Supply and fixed in repair stop valve/angle cock fancy type cast copper alloy, chromium plated with capstan head serewed down for 15 mm dia iron pipe complete all as specified and directed..
Taking up or down steel tubing of 15mm bore pipe and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store complete all as specified and directed.
Steel water tubing of 15 mm bore ‘medium grade’ galvanized with all fittings like socket, union, elbow, bend, tees etc fixed to walls and ceilings or laid in floors, complete all as specified.
Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power socket and bulk head fittings) on surface wiring on wooden batten/ casin caping complete including fixture and fittings such as switches, ceiling roses, pandents holder , regulators, sockets, lamp holder, buzzer , light fittings and defective main switch/DB/MCB/Metal plug etc by unscrewing carefully from board etc and making good disturbed surfaces of wall, floors, complete all as specified and directed.
M & L Point wiring for light/fan point controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC rigid conduit (medium grade) having thickness as per IS code with all fittings including galvanised pressed steel sunkum boxes having thickness as specified 3mm bakalite laminated sheet for switches and sockets, including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including cutting, chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour complete all as specfied and directed. Note : (a) Colour coding is to be maintained (Ph-Red, N-Black, Half -Yellow, Earth- Green) (b) On RCC roof ceiling PVC conduit shall be provided on surface for fan with proper fixing clips e all as specified and directed.
All as per above item no 89.00 here in before but for one 5 pin socket outlet 5 amp on independent board all as specified and directed.
All as per above item no 89.00 here in before but for one 3 pin socket outlet 5 amp on same board all as specified and directed.
M&L Point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC rigid conduit (medium grade) having thickness as per IS code with all fittings including galvanised pressed steel sunkum boxes having thickness as specified 3mm bakalite laminated sheet for one 3 pin socket outlet 15 Amp on independent board including 2.5sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including cutting, chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour complete all as specfied and directed. Note : (a) Colour coding is to be maintained (Ph-Red, N-Black, Half -Yellow, Earth- Green) complete all as specified and directed.
S&F Switch piano flush type one way 5 Amps single pole 240 volts complete all as specified and directed.
S&F Switch piano flush type one way 15 Amps single pole 240 volts complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volt complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin 5 and 15 amps flush type 230 volt complete all as specified and directed.
S&F Lamp holder PVC/Polycarbonate type with back plate having matching colour to holder for angle/batten fittings (ISI marked) complete all as specified and directed.
S & F Ceiling rose, 65x50mm three therminals isolated body (ISI marked) complete all as specified.
M& L celling fan regulator electronic socket type 5 stage speed variation ISI marked complete all as specified and directed.
Taking down ceiling fan by disconnecting the electric connection & dismantling the blades & removing from ceiling/roof of bldg by descrewing the nut bolt etc complete all as specified and directed. Note : Old u/s balance ceiling fans will be deposited in the store yard.
Rehanging only of ceiling fan and connecting up including provision of PVC insulated and overall sheathed flexible copper conductor cable 3 core of size 0.50 Sqmm from ceiling rose or connector to fan including minor repairs such as replacement of locking pin, hanging bracket, reel insulators, bolts, nuts, capacitor 2.5 mfd, bearing of suitable size etc and spraying one coat of synthetic enamel paint of required color all as per required and directed by Engr-in-Charge.
S&F in replacement of CFLs with LED smart lamp, B22 type 14 watt all as specified & directed
S & F of Jupiter I type Rectangular LED Highbay with excellent heat sink along with IP 66, 100 Watt including making connection with multistrand copper conductor of suitable size complete all as specified and directed.
S & F energy saving decorative LED box type (4 feet), 230 volts, 6500 K energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories prewired and including making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings. (Note power factor should not be less than 0.95) complete all as specified and directed.
S & F energy saving LED Rod 20 watt (4 Feet), 230 volts, 6500 K energy efficient tube light complete all as spd and directed.
S & F in replacement of sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed by Engr-in-charge.
M & L MCB SP 240 volts any rating from 20 to 40 ampsamps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed by Engr-in-charge.
M & L MCB SPN 240 volts any rating from 6 to 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cablescomplete all as specified and directed by Engr-in-charge.
S & F in replacement of sheet metal enclosure with socket plug top, triple pole and earth encolsure with a three pin and earth plug with socket complete with including one triple pole MCB 32 amps, 415 volts complete all as specified and directed by Engr-in-charge.
Material and labour earthing complete with galvanized steel earth plate electrode 60cmx60cm and 6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate including earth work in any type of soil, all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion. NOTE :-Rates inclusive of necessary earth work in any type of soil, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
M& L for providing /cutting the round/square hole of required size in wall and finishing the same disturbed surface to match the existing finishes and including supply & fixing ventilation fan AC sinlge phase 230/240 volts of size 250 mm sweep, 900 RPM complete including grouting the ragged bolts in wall and including PVC insulated 1.5 sqmm copeer cable connecting to ceiling rose all as required or directed and writing MES no with black synthetic enamel paint 2 cm high complete all as specified and directed.
S & F in replacement of old unsv sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB of comprising yhree phase four wire copper strip bus bar of appropriate capacity complete all as specified and comprising of the following (a) MCCB FOUR POLE 100 AMPS AC 415 VOLTS 25 KA=01 NO as incoming and 12 nos. MCB SP 40 Amps, C series as outgoing (Note :- (i) The DB shall be VTPN series of Schenieder Cat Part No :- A9HVD04K or equivalent in any of the make mentioned in list of product. (ii) The DB shall be flush fixed, and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost. (iii) connection ofthe MCCBs/ MCBs with cable shall be made throughapproprite size pin/ bottle type thimble complete all as specified and directed.
Supply and laying in replacement of existing unserviceable/ burnt submain wiring alongwith two single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of size 6 sqmm drawing into and including concealed PVC rigid non metallic conduit of 20mm dia , 1.8 mm wall thickness and single core cable PVC insulated and unsheathed cable with copper conductor FRLS (multistrand) of 6 sq mm as earth wire including cutting chases in brick wall, rendering in cement mortar 1:4 and making good the disturbed surfaces to match existing complete all as specified & directed. Note: (i) Two runs of 6 Sqmm single core PVC insulated copper conductor cable(FRLS) and one run of 6 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of 20mm dia , 1.8 mm wall thickness wiil be measured as a one unit. (ii) Proper colour coding is to be followed as per IS Specification. (iii) Test certificates of cables to be submitted before commencement of work/ claiming for payment. (iv) wiring shall be concealed/ on surface with rigid PVC conduit medium grade as per site requirement. (v) Electric Wiring test sheet before and after completion of wiring to be submitted before claiming payment
Supply and fix bldg security light fittings with LED security light fittings 30 watt, 5700 K, IP-66 having pressure die cast aluminium alloy housing, prismatic polycarbonate cover complete including making connection with 3 core copper flexible cable of suitable size including galvanised iron pipe medium grade bracket 1.5 metre long of 32 mm dia with clamps etc and fixing with bldg for fixing of street light fitting all as directed. Notes :- (i) Contractor shall produce LM79 & LM 80 test report from OEM owned NABL accredited laboratory. (ii) Contractor shall give guarantee/ warranty of complete fitting/ fixture for minimum 2 years from the date of completion. (iii) Contractor shall conduct the inspection of company representative at site before installation of the material at no extra cost. (iv) Contractor shall arrange complete material at site for approval of GE before incorporation in the work. (v) Driver shall be IP 66 degree of protection potted seal type with inbuilt SPD and external SPD of capacity 10 KV to be provided in addition to inbuilt.
Notes : The Schedule of Credit amount shall be deducted from the total of this schedule(BoQ) to arrive at Contract Sum.
jagdambe traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .