Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
2 Dec 2026, 4:30 pm6d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Agriculture Produce Marketing Committee
SECTION OFFICER
Providing Replacement of Existing Damaged/Burnt-Out UG Cable Network to LT, ABC Cable Network with RCC Pole at Main Market Yard of APMC Mandya, Approved under 2025-26 Annual Action Plan
APMC/2026-27/EL/WORK_INDENT1069
APMC/2026-27/EL/WORK_INDENT1069
Open
Electrical
Two Tender Document System(Two Cover)
SECRETARY APMC Office MANDYA
3 documents required · 3 mandatory
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
ALL TERMS & CONDITIONS APPLY AS PER THE TENDER DOCUMENT
₹1,350
₹1.1 L
29 Oct 2026
29 Oct 2026
7 Dec 2026
23 Nov 2026
23 Nov 2026
90 days
Providing Replacement of Existing Damaged/Burnt-Out UG Cable Network to LT, ABC Cable Network with RCC Pole at Main Market Yard of APMC Mandya, Approved under 2025-26 Annual Action Plan
RCC Pole - 9 Mtr Long, 145 Kg WL. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per Specific...
Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing. Ordinary Soil. The rates inclusive cost of all materials, labour charges, hire charges ...
Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and wor...
Base Concreting with CC 1:4:8, Pole base for 11/9.5/9/8 Mtr supports (500x650x150mm). The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and ...
Pole Concreting with CC 1:2:4 (without coping), 9 Mtr support (650x500x1700mm). The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts ...
Providing Coping for Pole with CC 1:2:4 (As per actuals) 150 mm all around the Pole for an height of 300 mm for RCC, PSCC Pole. The rates inclusive cost of all materials, labour charges, hire charges ...
RCC Pole - 8 Mtr Long, 115 Kg WL. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per Specific...
Digging of Pit 1.6 Mtr depth for erection of 7.5/8 Mtr Long Steel/RCC/PSCC supports as per approved Drawing. Ordinary Soil. The rates inclusive cost of all materials, labour charges, hire charges of t...
Erection of RCC/PSCC Pole of 7.5 to 8 Mtr long in a pit of 1.5 Mtr depth. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and wo...
Spiral Earth Electrodes. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per Specifications an...
Providing spiral earth electrode type earthing along with pole (without charcoal, salt etc.,). The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all ...
Pole Clamp for HT/LT AB cable. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per Specificati...
Fixing of Pole Clamp - 145 mm x 95. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per Specif...
Full Threaded Bolt & Nut as per IS-1367 16x40 mm GI. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried ...
1.1 kv, LT Aerial Bunched Cable, confirming to IS-14255:1995 XLPE insulation. 3x95 + 1x70 + 1x16 Sqmm Street light (Insulated Messenger cum Neutral). The rates inclusive cost of all materials, labour ...
Stringing of 1.1 kV grade Aerial Bunched 3 Core cable of XLPE insulation of size (3x95) (Phase Conductor) + (1x70) (Insulated Messenger Neutral) + (1x16) (Street Light Control). The rates inclusive co...
Three phase distribution box for 6 connection. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as...
Installation of Distribution box suitable for 6 3 phase connections. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work sh...
Piercing connector for suitable for 16 sqmm- 95 sqmm AB Cable for service connections. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and...
Installation of Insulation piercing connector for main to service line Main : 16-95sqmm, Tap : 4-35sqmm(P2X95). The rates inclusive cost of all materials, labour charges, hire charges of the machineri...
Piercing Connector Suitable for 16 Sqmm - 95 Sqmm AB Cable - Street Light Connection. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and ...
Installation of Insulation piercing connector for Main to Street Light Main : 16-95sqmm, Tap : 4-35sqmm(P2X95). The rates inclusive cost of all materials, labour charges, hire charges of the machineri...
Suspension Clamp suitable for insulated Messsenger wire of size 25 to 95 Sqmm. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts a...
Erection of Suspension Clamp - 25 to 95 Sqmm insulated messenger with bracket. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts a...
Dead End Clamp/Anchor Clamp Assembly 25 to 95 Sqmm Bare Messenger (Exclusive of Pole Clamp and Eye Hook). The rates inclusive cost of all materials, labour charges, hire charges of the machineries inc...
Erection of Anchor Clamp - 25 to 95 Sq.mm insulated messenger with bracket. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and ...
Universal Hook and Bolts & Nuts. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per Specifica...
Eye Hook (Flat Type) for fixing clamps. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per Sp...
End Cap for 50/70 Sqmm. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per Specifications and...
Tee - Connector - KZ3 95. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per Specifications a...
Fixing of T-Connector KZ3 95. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per Specificatio...
Straight Joint Suitable for 95 Sqmm, LT ABC - MJPT Type. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carr...
Installation of Pre-insulated straight thru' joints-MJPT for 70 Sqmm cable. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and ...
Straight Joint Suitable for 70 Sqmm, LT ABC - MJPT Type. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carr...
Installation of Pre-insulated straight thru' joints-MJPT for 70 Sqmm cable. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and ...
Straight Joint Suitable for 16 Sqmm, LT ABC - MJPT Type. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carr...
Installation of Pre-insulated straight thru' joints-MJPT for 25 Sqmm cable. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and ...
Pre - Insulated Lug - CPTAU for 95 Sqmm. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per S...
Pre - Insulated Lug - CPTAU for 70 Sqmm. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per S...
Pre - Insulated Lug - CPTAU for 16 Sqmm. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per S...
Supplying heavy gauge PVC conduit pipe 32mm dia 2.5 mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ce...
PVC Wire - 25 Sqmm 1.1 KV Class HR (Heat Resistant) PVC Insulated & UnSheathed Aluminium Wires Multistrand Single Core Lead wires as per IS-694: 2010, Al Wt: 6.7 Kg, Total Wt: 11.5 Kg/100 Mtr Coil. Th...
Guy Set Complete with No. 8 Strain Insulator. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as ...
Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT). The r...
Guy concreting with Boulders, Mud and Sand. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as pe...
Supplying and Fixing 32.mm dia clamps Class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL str...
Supply of 90 Watts LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with ...
Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wirescomplete with all leads & lift a...
Fabricating, supplying and mounting of MS automatic street light control box of size 25,000 sqcm MS Box with following component, 6400 sqcm hylum sheet, 12 mtrs of angle iron, 1 no' of LED type panel ...
1.1 kV, 10 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm) XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thick...
1.1 kV, 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thic...
Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricadin...
Laying of 2.5 to 25 Sqmm LT UG cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. The rates inclusive cost of all materials,...
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 ...
Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, Up to 4C x 50 Sqmm LT UG Cable. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and l...
Straight Through Jointing Kit Suitable for 1.1 kV Class 10 Sqmm, 2 Core LT UG Cable as per IS-13573. The rates inclusive cost of all materials, labour charges, hire charges of the machineries includin...
Straight Through Jointing Kit Suitable for 1.1 kV Class 10 Sqmm, 4 Core LT UG Cable as per IS-13573. The rates inclusive cost of all materials, labour charges, hire charges of the machineries includin...
HDPE pipe grade PE100-PN10.0, 90 mm. The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per Speci...
Aluminium End Terminal 10 Sqmm (Lug). The rates inclusive cost of all materials, labour charges, hire charges of the machineries including all lead and lifts and work should be carried out as per Spec...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Electrification to MMY KW-3 Mandya.doc
Tender Document • 0.28 MB
NOTIFICATION2.pdf
Others - NOTIFICATION2 • 0.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .