RequiredCertificate (Requested in ATC) Bid to RA enabled No Breath Alcohol Analyzers ( 2 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) TECHNOLOGY PERFORMANCE Sensor Technology ElectroChemical - Fuel Cell (alcohol specific) ElectroChemical - Fuel Cell (alcohol specific) Sampling Method Deep Lung Exhalation Method * Sampling Error Detection Alarm on wrong sampling * Sampling modes Both Active and Passive * 1/6 Measuring Range [mg/100 ml BAC (Blood Alcohol Concentration)] 0 to 600 0 to 400
Required0 to 600 Accuracy +/- 5 % or better * Drift of the breath analyzer in 6 months period (mg/100 ml BAC) 1 0.0 - 1.0 Or lower Easily replaceable mouthpiece with Sputum Trap yes * Sample Taking Duration 4 * Analytical Response Time (At '0' level of Alcohol) 3 * Analytical Response Time for positive result 5 * Recovery Time at (1/2) mg/ltr 1 * Warm up Time (after putting on) 5 * Time required for re- calibration 12 * Barometric Pressure Range (hpa or millibar) 1200 * Shelf Life of Fuel Cell 5 * RoHS Compliant Yes * The Equipment meet RFI requirement as per EN:5008-1/1992(emissi on) and EN 50082-1:19 97(immunity) or equivalent requirements Yes * PHYSICAL Weight 259.16 * Size ( mm x mm x mm ) - * BATTERY OF ANALYZER Power Source Rechargeable Battery * Chemistry of Rechargeable Battery Ni-MH * Battery Voltage 7.4 * Battery Backup Time (continuous duty) 160 * Number of Spare 1 * 2/6 Rechargeable Batteries supplied with the instrument Low Battery indication yes * DISPLAY/INDICATOR STORAGE/INTERFACE Display Type LCD * Display Size 2 * Availability of audible beeper for over range
Requiredlow battery etc yes * Record Entry Through Integrated/Touch Screen Through Integrated/Touch Screen
RequiredThrough Alphanumeric KeyBoard Minimum Record Fields Full Information as per the user's requirement such as Driver Name
RequiredVehicle number
Requiredinspector name
Requiredtest report with time
Requireddate
Requiredgeolocation
Requiredinstrument id
Requiredetc * Record Memory (Minimum) 4000 4000 Record Data Downloadable to PC yes * Data Interface USB * GPS No * If yes
RequiredCapable to display the geolocation of test inspection location NA * Camera No No If yes
RequiredCapable to capture the clear image of test target NA * PRINTER Printer With With Type of Printer Portable Dot Matrix Printer with Wireless Bluetooth Connectivity Portable Dot Matrix Printer with Wireless Bluetooth Connectivity Print Resolution (dpi) 300 * Printer consists of Inbuilt Rechargeable Battery
RequiredPaper for offence printouts
RequiredCharger yes * Minimum number of printouts that can be 1 * 3/6 taken with the paper available with the Printer "Minimum number of printouts that can be taken with single charge of the printer battery (Hint:- Minimum 60 prints
Requiredif 'With Printer' May indicate '0' if not applicable)" 85 * Bis Registration number for Printer under CRS of MeitY - * WARRANTY Warranty 2 1
Required2
Required3
Required4
Required5 Or higher STATUTORY REQUIREMENTS The equipment can be used as an evidential instrument for Traffic Law Enforcement
RequiredThe instrument is hand held
Requiredportable and easy to operate Yes * If Yes
Requiredthe equipment meets the requirements of the applicable latest Central Motor Vehicle Rules and all Govt notifications yes * Immunity to RF interface
Requiredmeets requirement as per EN: 5008-/1992(emission) and EN:50082-1:1997 (immunity) or equivalent yes * OPERATING CONDITIONS Minimum Operating Temperature -5 * Maximum Operating Temperature 55 * Relative Humidity Non Condensing (%) 90 * ENVIRONMENTAL CERTIFICATION Conformity to Dry Heat test at 50 degree C for 16 hours as per IS :9000 latest Yes * Conformity to Damp heat at 40 degree C - 95% RH (cyclic test): two cycles of 16+8 hours as per IS: 9000 Yes * 4/6 latest Conformity to Cold test at - 5/-10/- 15/-20 degree C (as applicable) for 4 hours as per IS: 9000 latest Yes * Availability of Test Reports from Central Govt/NABL approved ILAC accredited Lab to prove conformity to the specification Yes * Test Report Number and Date - * Name of the Lab and Address - * * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.