Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC | ₹1.8 Cr | L1 | Accepted-AOC ok |
| 2 | L2₹2.0 Cr+₹16.1 L (8.90%)Rejected-Finance | ₹2.0 Cr+₹16.1 L (8.90%) | L2 | Rejected-Finance ok |
| Sl No | Description | Qty | Unit | Vishal Kumar L1 | Nitin Walia Contractor L2 |
|---|---|---|---|---|---|
| 1.00 | Providing and fixing of LUME LED driver of 96 watt (Model No A962406CV) 96W 24V DC P65 as per TISVA
brand products from usha international Ltd (UIL). | 4 | Each | 1,849 ₹7,396 Lowest | 1,849 ₹7,396 Lowest |
| 2.00 | Providing and fixing of LUMELACE LED profile light of 70 watt (Model No SP 70W 3K 24V180L 5MTR IP65) as
per TISVA brand products from usha international Ltd (UIL). | 4 | Each | 1,877 ₹7,508 Lowest | 1,877 ₹7,508 Lowest |
| 3.00 | Supply, Installation, testing and Commissioning of modular type Variable
Refrigerant Flow/ Variable Refrigerant Volume aircooled Outdoor units suitable
for cooling and heating, having all hermetically sealed inverter type Scroll
Compressor(s), minimum two compressors for above 14HP modules,
microprocessor based Controller, top discharge type condensing unit(s), with
R407c/R410a/EQUIVALENT Refrigerant, vibration isolators, with suitable
foundation etc. complete as required. The unit shall deliver the rated capacity at
AHRI Conditions and work even at 50 ° C ambient temperature without tripping.
The unit shall be suitable to work on 400V plus /-10%, 3Phase, 50Hz AC power
supply. The unit shall be filled with first charge of the refrigerant and ready for
use as required. | 4 | Each | 4,00,000 ₹16,00,000 Lowest | 5,00,000 ₹20,00,000 |
| 4.00 | Supply, installation, testing and commissioning of following minimum capacity
VRV/VRF TFA Indoor ceiling mounted unit equipped with synthetic washable
media pre-filter, fan section with low noise fan/dynamically balanced blower,
multispeed motor, coil section with DX Copper coil, electronic expansion valve,
outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless
remote control etc., suitable for operation on single phase 230V ± 10%, 50Hz AC
supply, complete, as required.
1300 CFM | 1 | Each | 1,90,000 ₹1,90,000 Lowest | 2,00,000 ₹2,00,000 |
| 5.00 | Supply, installation, testing and commissioning of following minimum capacity 4-
way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with
synthetic washable media pre-filter, fan section with low noise fan/dynamically
balanced blower, multispeed motor, coil section with DX Copper coil, electronic
expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration
isolation, cordless remote control etc., suitable for operation on single phase
230V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of
indoor unit will be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature. 2.0 TR | 10 | Each | 70,000 ₹7,00,000 Lowest | 1,00,000 ₹10,00,000 |
| 6.00 | Supply, installation, testing and commissioning of following minimum capacity 4-
way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with
synthetic washable media pre-filter, fan section with low noise fan/dynamically
balanced blower, multispeed motor, coil section with DX Copper coil, electronic
expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration
isolation, cordless remote control etc., suitable for operation on single phase
230V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of
indoor unit will be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature. 1.5 TR | 5 | Each | 70,000 ₹3,50,000 Lowest | 1,00,000 ₹5,00,000 |
| 7.00 | Supply, installation, testing and commissioning of following minimum capacity
VRV/VRF Hi-wall Type Indoor ceiling mounted unit equipped with synthetic
washable media pre-filter, fan section with low noise fan/dynamically balanced
blower, multispeed motor, coil section with DX Copper coil, electronic expansion
valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation,
cordless remote control etc., suitable for operation on single phase 230V ± 10%,
50Hz AC supply, complete, as required. The cooling capacity of indoor unit will
be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature.1.0 TR | 1 | Each | 70,000 ₹70,000 Lowest | 1,00,000 ₹1,00,000 |
| 8.00 | Supply, installation, testing and commissioning of following minimum capacity
VRV/VRF Hi-wall Type Indoor ceiling mounted unit equipped with synthetic
washable media pre-filter, fan section with low noise fan/dynamically balanced
blower, multispeed motor, coil section with DX Copper coil, electronic expansion
valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation,
cordless remote control etc., suitable for operation on single phase 230V ± 10%,
50Hz AC supply, complete, as required. The cooling capacity of indoor unit will
be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature.1.5 TR | 4 | Each | 70,000 ₹2,80,000 Lowest | 1,00,000 ₹4,00,000 |
| 9.00 | Supply, unloading, storing, shifting, installing, testing and commissioning of
Color touch screen type central controller for Control indoor units temperature
and capable of catering above mentioned indoor units and capable to connect
with BMS, if required. The price shall include the control wiring with MS
conduits and any other accessory required to complete the installation. The
controller shall be capable of changing temperature, fan speed, timer ,
temperature lock for any of the indoor unit and shall be BMS compatible. VRV/VRF Central Controller | 1 | Each | 70,000 ₹70,000 Lowest | 1,00,000 ₹1,00,000 |
| 10.00 | Supply, Installation, testing and commissioning including vaccumiazation and
Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant
piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable
ring type hanger supports, jointing/ brazing including accessories, insulated
with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric
nitrile rubber tubular sleeves sections of specified thickness as given below for
Suction and Liquid lines, all accessories as per specifications etc. as required :
For exposed piping, UV and Mechanical protection shall be with 6-7 mil minimum
thickness and 200 gram/sqmt ±10% interwoven glass fabric. | 31 | Metre | 399 ₹12,369 Lowest | 399 ₹12,369 Lowest |
Tender Value
₹1.7 Cr
EMD Value
₹3.8 L
Closing Date
24 Aug 2024, 3:00 pmClosed
SURENDER SINGH
Municipal Council Thanesar
REPAIR AND RENOVATION MODIFICATION AND BEAUTIFICATION OF COMMUNITY CENTER IN SECTOR- 8 AT M.C.THANESAR, KURUKSHETRA
2024_HRY_400612_1
20248DF0864E 3E85 409E AC68 07059DA9975C290ULB
Open Tender
Civil Works
Works
180 days
Kurukshetra (Thanesar)
2 documents required · 2 mandatory
₹15,000
₹3.8 L
Yes
15 Sept 2025
14 Aug 2024
24 Aug 2024
14 Aug 2024
24 Aug 2024
14 Aug 2024
Amount
Providing and fixing of LUME LED driver of 96 watt (Model No A962406CV) 96W 24V DC P65 as per TISVA brand products from usha international Ltd (UIL).
Providing and fixing of LUMELACE LED profile light of 70 watt (Model No SP 70W 3K 24V180L 5MTR IP65) as per TISVA brand products from usha international Ltd (UIL).
Supply, Installation, testing and Commissioning of modular type Variable Refrigerant Flow/ Variable Refrigerant Volume aircooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R407c/R410a/EQUIVALENT Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50 ° C ambient temperature without tripping. The unit shall be suitable to work on 400V plus /-10%, 3Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required.
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF TFA Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V ± 10%, 50Hz AC supply, complete, as required. 1300 CFM
Supply, installation, testing and commissioning of following minimum capacity 4- way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature. 2.0 TR
Supply, installation, testing and commissioning of following minimum capacity 4- way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature. 1.5 TR
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF Hi-wall Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature.1.0 TR
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF Hi-wall Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V ± 10%, 50Hz AC supply, complete, as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 DegreeC DB and 19 DegreeC WB temperature.1.5 TR
Supply, unloading, storing, shifting, installing, testing and commissioning of Color touch screen type central controller for Control indoor units temperature and capable of catering above mentioned indoor units and capable to connect with BMS, if required. The price shall include the control wiring with MS conduits and any other accessory required to complete the installation. The controller shall be capable of changing temperature, fan speed, timer , temperature lock for any of the indoor unit and shall be BMS compatible. VRV/VRF Central Controller
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : For exposed piping, UV and Mechanical protection shall be with 6-7 mil minimum thickness and 200 gram/sqmt ±10% interwoven glass fabric.
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : For exposed piping, UV and Mechanical protection shall be with 6-7 mil minimum thickness and 200 gram/sqmt ±10% interwoven glass fabric.9.5 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : For exposed piping, UV and Mechanical protection shall be with 6-7 mil minimum thickness and 200 gram/sqmt ±10% interwoven glass fabric.9.5 mm dia (OD) (Softdrawn) with tube thickness 12.7 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : For exposed piping, UV and Mechanical protection shall be with 6-7 mil minimum thickness and 200 gram/sqmt ±10% interwoven glass fabric. 19 mm dia (OD) (SOFTDRAWN) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : For exposed piping, UV and Mechanical protection shall be with 6-7 mil minimum thickness and 200 gram/sqmt ±10% interwoven glass fabric. 22.2 mm dia (OD) (Harddrawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : For exposed piping, UV and Mechanical protection shall be with 6-7 mil minimum thickness and 200 gram/sqmt ±10% interwoven glass fabric. 25.4 mm dia (OD) (Harddrawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : For exposed piping, UV and Mechanical protection shall be with 6-7 mil minimum thickness and 200 gram/sqmt ±10% interwoven glass fabric. 28.58 mm dia (OD) (Harddrawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : For exposed piping, UV and Mechanical protection shall be with 6-7 mil minimum thickness and 200 gram/sqmt ±10% interwoven glass fabric. 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : For exposed piping, UV and Mechanical protection shall be with 6-7 mil minimum thickness and 200 gram/sqmt ±10% interwoven glass fabric. 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Providing and fixing of PVC pipe for condensate drain water with fittings, support and insulated with 6mm thick closed cell elastomeric nitrile rubber insulation complete as per specifications. As per specification/drawings and as directed by Engineer In Charge. All associated Civil Engineering works as per requirement at site in above connection like making core cutting in the wall and restoring it original shape by replasteringand repainting, etc. are included in the scope of work 7.1 25 mm
Providing and fixing of PVC pipe for condensate drain water with fittings, support and insulated with 6mm thick closed cell elastomeric nitrile rubber insulation complete as per specifications. As per specification/drawings and as directed by Engineer In Charge. All associated Civil Engineering works as per requirement at site in above connection like making core cutting in the wall and restoring it original shape by replasteringand repainting, etc. are included in the scope of work 8.2 32 mm
Providing and fixing of PVC pipe for condensate drain water with fittings, support and insulated with 6mm thick closed cell elastomeric nitrile rubber insulation complete as per specifications. As per specification/drawings and as directed by Engineer In Charge. All associated Civil Engineering works as per requirement at site in above connection like making core cutting in the wall and restoring it original shape by replasteringand repainting, etc. are included in the scope of work 8.3 40 mm
Supply and laying, testing and commissioning of following sizes of Copper conductor control cables through conduit on existing tray including fixing clamps and proper connections to equipments etc. complete as required. As per specification/drawings and as directed by Engineer In Charge .9.1 2C x 1.5 sq.mm.
Supplying and fixing of 150mm dia exhaust disc valve as per specifications.
Supply, Installing, testing and comissioning of Powder coated extruded aluminium construction gravity / fixed louvers. These shall be fixed with ventilation fans and as per technical specifications/drawings with all the necessary mounting accessories as required for complete installation, and as directed by Architect and Engineer In Charge
Supplying and fixing of thermal insulation on exposed roof (underdeck) with 19mm thick XLPE / EPDM Rubber foam with completely closed cell structure as per specifications - Density 40-60 kg /cum , Class A as per ASTM E 84 , Class V-0 as per UL 94 and Mu value ) 7000, tape and adhesive (pidilite SR -998) as required and finally fixed with the help of rawl plug and dash fasteners in ceiling.
Providing, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100mm nominal dia
Providing, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80mm nominal dia
Providing, fixting testing and commissioning C.I. flanged `Y` type Strainer with SS screen, suitable flanges, nuts, bolts, gaskets etc. complete. 100mm dia
Providing fixting, testing and commissioning of Gun metal chrome finished Ball valves with fittings of screwed end type. 25 mm nominal dia ( Air vessel tank and Pressure switch manifold)
Providing fixting testing and commissioning of differential Pressure switches of suitable range (0 to 12 bar) for pumpsets complete with necessay Ball valves, Fittings like unions / colors / reducers etc.( Standard type for main pump and Differential type for Jockey Pump)
Providing, fixing, testing and commissioning of air vessel tank shall be fabricated out of of 250 mm dia MS pipe to 1000 mm long complete with 25mm inlet, 25mm drain, 25mm dia connection for air release valve including legs, painting with red oxide primer and finished with fire red enamel paint. It shall be inclusive of all relevant pipes, valves, specials upto pump header and other accessories etc
Providing fixting testing and commissioning Single headed hydrant valve as per IS 5290, madeof gunmetal with 63 mm dia instantaneous outlet of 80 mm dia flanged inelt ,Blank caps , chain and hand wheels etc complete
Providing fixting testing and commissioning 15 M long, 63mm dia RRL hose confirming IS 636 with gun metal instantaneous couplings and Hoses shall be stored inside the hose cabinet.
Providing fixting testing and commissioning Hose reel drum of swinging type with 19mm dia Rubber braided hose of 30m length with Ball valve and Shut off nozzle, complete.
Providing fixting testing and commissioning Gun metal short branch pipe with nozzle confirming to IS 903.
Providing fixting testing and commissioning Fire duct Shutter fabricated out of M.S. sheet and frame, door shall be 600mm x 1200 mmx2100mm min. and fixed with 4 mm thick Glass, suitable Rubber beading and Locking arrangement. Quoted rate shall be includes all fasteners etc, and complete shutter shall be powder coated finish of red colour both inside and out side
Providing fixting testing and commissioning and of approved make 25mm dia. automatic air release valve with unions etc. complete
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 100mm nominal dia
Providing, laying, testing and commissioning of `C` class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required 80mm nominal dia
Providing and fixing 2 way fire brigade inlet connection 100mm dia
Carbon-di- oxide type fire extinguisher of 4.5 kgs. Capacity, Co2 gas as per IS 15222 with controll discharge mechanism fitted with Hose and Horn applicable on Class B fire rating 21B confirming to IS: 15683:2008. CO2 Cylinder as per IS 7285 with ISI mark.
ABC powder type fire extinguisher of 6 Kgs. Capacity, with initial filling (Mono Ammonium Phospate Powder) in brand new cylinder with powder coated finish, Stored Pressur type, Pressure Gauge, Controllable discharge mechanism with Hose and Nozzle , confirming to IS:15683:2008.
Providing and fixing, testing and commissioning of required sintex tank 5kl
Supply and Fixing of signs Auto-Glo, (list of design attached), based on acrylic, single sided wall pasted size 12” x 6”
Providing and Fixing of PVC Louver in wall cladding as per drawing complete in all respect as per satisfaction of Engineer-in charge
Providing and fixing of Aluminium louvers with wooden texture paint complete in all respect as per the direction of engineer-in-charge
Providing and fixing shading fins of MS pipe having size 100mmx50mmx1.5mmthickness with duco paint complete in all respect as per entire satisfaction of engineer-in-charge
Providing and fixing of tensile structure made of PVDF coated fabric of 950 gsm with 15 years warrenty with ms structure pipe of 150mmx3.5mm, ms structure purling of size 89mmx3.5mm with ms brasing pipe of size 50mmx3.5mm along with ms base plate of size 400mmx400mmx16mm with epoxy paint and pu spray paint complete in all respect as per the direction of engineer-in-charge
Outdoor Furniture in Open gym and playing equipments in various parks
Outdoor Furniture in Open gym and playing equipments in various parks Providing and fixing of Park Equipments Chair Swing
Outdoor Furniture in Open gym and playing equipments in various parks Providing and fixing of Park Equipments Straight Slide
Outdoor Furniture in Open gym and playing equipments in various parks Providing and fixing of Park Equipments Double See-Saw
Supply, Installation, testing and Commissioning of the following lighting fixtures with all fixing accessories etc. Complete as required .(NS)…………… 07 Watt Downlights- Recessed Mounted
Supply, Installation, testing and Commissioning of the following lighting fixtures with all fixing accessories etc. complete as required.(NS)……………18W LED Tube light with accessories as complete required.
Providing and fixing of Circular C.I. Box for ceiling fan internal dia140 mm, 73 mm height, top lid of 1.5mm thick MS sheet.
Supply, Installation, testing and Commissioning of the following lighting fixtures with all fixing accessories etc. complete as required.(NS)……………600x600mm, 36W LED Reccessed Mounted light with accessories as complete required.
Supply and erection of single arm bracket made of 40mm dia G.I pipe B class ISI 1.50 mtr long with coller pipe GI 75mm dia 60cm long Top covererd with ornamental Cap duly welded painted 2 coats of aluminium paints on bracket and golden pant of ornamental cap including the cost of labour and petty material etc complete in all respect up to the entire satisfaction of Engineer in charge of the work
Supply and erection of 65 Amp. 3 Phase automatic/ digital time switch of Indo Asian Make HSN code 8537 along with contactor of required capacity of Indo Asian Make movement controlled by precisaty quartz oscillation operation on main supply of continue to run on built in rechargeable nickle cadium call for 150 hours in the event of power failure including cost of all petty items complete in all respect upto the entire satisfaction of Engineer in charge of work.
Supply and erection of LED Street light luminaires of Bajaj, GE, Philips, Wipro, Mayfair, Crompton, Surya Roshni, HPL, Halonix, Insta Power, Havell`s, Ecolite, CandS Electric SE-Sangwan Energy, Legero etc Polycab, make 45 Watt LED and accessories required to complete the job in all respect including erection on existing pole for fixing including connection of the same upto the entire satisfaction of Engineer in Charge of the work
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade 3½ C - 70 sq mm Aluminium
Supply, following sizes of PVC sheathed PVC/XLPE insulated Aluminium conductor/copper conductor power/ multicore control armoured cable of 1.1 KV grade. 4C- 10 sq mm Aluminium
Providing and fixing of SBR Rubber Tiles of size 20`x20` with 25mm thick grey in colour of `Amazon Flooring `Providing and fixing of SBR Rubber Tiles of size 20`x20` with 25mm thick grey in colour of `Amazon Flooring` complete in all respect up to the entire satisfaction of Engineer-in charge of the work. complete in all respect up to the entire satisfaction of Engineer-in charge of the work.
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : For exposed piping, UV and Mechanical protection shall be with 6-7 mil minimum thickness and 200 gram/sqmt ±10% interwoven glass fabricY-Joints (Suction plus Liquid)
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/ hard drawn copper refrigerant piping for DX/VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/ brazing including accessories, insulated with XPLE Class-O tubular insulation/ with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : For exposed piping, UV and Mechanical protection shall be with 6-7 mil minimum thickness and 200 gram/sqmt ±10% interwoven glass fabric. 15.86 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and Commissioning gi duct 130 sqm and as directed by Engineer In Charge
Providing, fixing, jointing and testing uPVC mineral filled floor traps of self cleansing design with water seal not less than 50 mm., with or without vent, jointing with push fit rubber ring socket fittings complete, cutting chases / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position in case of suspended / open plumbing or setting the trap in 1:2:4 CC in case of concealed plumbing , etc. complete, as required. The trap shall be of following sizes: Temporary airtight PVC cover to be provided to prevent dirt entry
Providing and fixing health faucet with 1.2 m long flexible tube and wall hook including all fittings.
Providing and fixing water tank filling alram system complete in all respect as per entire satisfaction of engineer-in-charge
Providing and Fixing of stainless steel grating with rim of approved design including setting in floor with cement mortar. (For Floor Trap/Floor Drain) 125 mm dia
Providing and fixing uPVC pipe conforming to IS:4985 (10 kg/sq cm) including all fittings, This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge and as per layout. 40mm
Providing and fixing uPVC pipe conforming to IS:4985 (10 kg/sq cm) including all fittings, This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge and as per layout. 110mm
Providing and fixing floor drain fixed with cement mortar complete in all respect. 110 x 50
Providing and fixing water pump for tank filling
Providing and fixing 100 mm dia uPVC hopper approximately 300 mm long with maximum 3 inlets 32, 50 or 63 mm size fabricated from uPVC heavy duty pipes , sockets, fixed to UPVC trap with joint and set in cement concrete mix 1:2:4 complete as per standard drawing 110mm
Providing and fixing 15mm flexible pipe 15 mm dia 110mm
Providing and fixing of approved coloured verticle type hot water 25 ltr geysers. The inner container shall be made of copper sleeve with PUF insulation between inner and outer container, element pipe and heating element, pressure cum vaccume release, thermostat and thermal cutout arrangements and fusible plug. The outer container shall be of powder coated finish with all other accessories including fixing brackets complete as required.
Providing and fixing CP brass Overhead shower with shower arm, Hand Shower 95mm dia and Easy flex Tube with accessories complete I all respect 110mm
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 40 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 50 mm nominal bore
PROVIDING AND FIXING OF BEIGE BROWN COBBLE STONE AS PER COBBLE STONE PVT. AS PER DIRECTION OF THE OFFICER - IN CHARGE.
Bidder Name
Amount
Vishal Kumar (GSTN-NA) BID ID -1147065
Nitin Walia Contractor (GSTN-NA) BID ID -1147348
Nitin Walia Contractor (BID ID -1147348)
Nitin Walia Contractor (BID ID -1147348)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .