Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹24.5 L+₹2.3 L (10.3%)Rejected-Finance 252 22 NEAR SOCITY BUS STAND INDRA COLONY PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹24.7 L+₹2.5 L (11.1%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹26.7 L+₹4.5 L (20.1%)Rejected-Finance 30 B 1 DEEN DAYAL NAGAR NAWABGANJ DEEN DAYAL NAGAR KANPUR NAGAR UTTAR PRADESH 208002 | KANPUR NAGAR | UTTAR PRADESH | 208002 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹27.8 L+₹5.6 L (25.0%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
15 Apr 2024, 6:00 pmClosed
GE 860 EWS
GE 860 EWS C/O 56 APO
REPAIR/ MAINTENANCE TO STREET LIGHTS/ SECURITY LIGHTS, JUNCTION BOXES, GARDEN LIGHTS, LT UG CABLE AND CONNECTED WORKS SERVICES AT KARU AND SHESHARTHANG AREA UNDER GE 860 EWS
2024_MES_647511_1
8134/2024-25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
KARU AND SHESHARTHANG
Refer NIT
9 documents required · 9 mandatory
₹500
GE 860 EWS
₹1 L
Yes
15 Jun 2024
22 Mar 2024
17 Apr 2024
22 Mar 2024
15 Apr 2024
8 Apr 2024
Amount
Excavation in trenches in hard / dense soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide and getting out including trimming of sides, for laying of cables & foundation of poles, stay assembly, complete all as specified and directed by Engr-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed by Engr-in-Charge.
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed by Engr-in-Charge.
Taking out old unserviceable/serviceable un-reinforced concrete PCC cable covers from excavated trench all as directed by the Engineer-in-Charge. Note:- Serviceable un-reinforced concrete PCC cable cover kept in safe custody for reuse at site and unserviceable un-reinforced concrete PCC cable cover through in low lying area.
Laying only old reinforced PCC cable cover of any size as retrieved from serial item No- 4.00 above, complete all as directed by Engineer-in-Charge.
M&L for factory made un-reinforced pre cast concrete cable protection cover LV class type - I with size 250mm x 150mm x 40mm laid across the cable (i.e. width of cover along the length of cable) for UG cable protection on the top of the sand cushioning, complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to UG cable, complete all as specified and directed by Engr-in-Charge. NOTE: Punned down thickness of sand shall be measured.
Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade 10 sq mm 2 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as directed. Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
S&F of galvanized iron pipe of 40 mm nominal dia light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint, complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
Dismantling and taking down unserviceable / defective street light fitting / Flood light fitting of any wattage alongwith mounting bracket, flat iron clamp, nuts bolts etc from overhead LT poles complete all as directed.
S&F of LED street light luminaire of 35 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge.
S&F of LED street light luminaire of 60 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge.
S&F of LED street light luminaire of 90 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge.
S&F of LED street light luminaire of 120 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge.
S&F of LED flood light luminaire of 100 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge.
S&F of LED flood light luminaire of 210 Watt capacity, made of single piece pressure die-cast aluminium housing with high power LED with lens for proper light distribution luminiaries, IP 66, with toughned glass cover and incl control gear etc, with and incl making all electric connection, complete all as specified and directed by Engineer in charge.
S&F LED step light 9 W with die cast aluminium housing with warm white CONE NXG - IP65 protection and including making all electric connection, complete all as specified and directed by Engineer in charge.
S&F LED post tops VICTORIA-IP 65, 40 W with die cast aluminium housing and polycarbonate opal diffuser and IP protection and incl making all electric connection, complete all as specified and directed by Engineer in charge. Make: Havells or equivalent of Phillips/Crompton as approved by GE
S&F LED post tops ENDURA SPRING-6, IP 65, 40 W with die cast aluminium housing and polycarbonate opal diffuser and IP protection and incl making all electric connection, complete all as specified and directed by Engineer in charge. Make: Havells or equivalent of Phillips/Crompton as approved by GE
S&F LED post tops 40 W with die cast aluminium housing and polycarbonate opal diffuser and IP protection and incl making all electric connection, complete all as specified and directed by Engineer in charge.
S&F in replacement of street light fitting bracket, 1.5 m long made out of galvanized iron pipe of 40 mm dia size light grade complete with and incl 02 nos MS clamp made of MS flate iron of 50 x 6 mm size with nut, bolts, washer etc with and including two coats of aluminum paint over a coat of red oxide primer, complete all as directed.
M&L for preparation old (exposed) painted surfaces of existing LT steel tubular street Light pole, struts including cross arms, clamps etc complete and applying two coats of aluminium paint over a coat of red oxide primer over the ground and making 30cm wide strip with black and yellow paint including numbering of HT/LT poles at a height of 1.5 mtr above ground level as per existing having 15mm width and 50mm bold letter complete all as specified and directed including Marking Red Stipn painting on HT Poles etc complete all as specified and as directed.
M&L for two run of 2.5 sqmm Aluminium conductor twin core cable for connection of the street light with junction box / Over head LT line complete all as specified and as directed by Engineer-in-Charge.
M&L, in replacement, Pole box outdoor type of size 14cmX19cm made out of MS sheet of thickness not less than 1.6 mm having hinged front opening door with two nos aluminium strip bus bar of capacity 63 amps fitted on resin based insulator and One no. MCB SPN 32 Amps rating and suitable size of clamps for mounting the junction box on Garden light post and painted with two coats of synthetic enamel aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Supply, fixing and testing of Automatic Street Light Control Switch with panel complete with :- (a) Infrared senser based 01 nature switch for automatic switching of street lights. Nature switch operation should based on natural light lux level required illuminance level for switching "ON" is less or equal to 30 lux and for switching "OFF" is 10 lux. The sensor should also have part night operation facility of minimum 04 hrs to maximum 12 hrs - 01 Nos. Make of Sensor - Kakatiya Energy System/Bajaj/Healer. (b) Power Contactor single phase, 230 Volts, 40 Amps capacity cnforming to IEC-60947-4-1 03 Nos. Make - BCH/L&T/Schneiders (c) The sensor along with suitable Power Contactor and Incoming/outgoing MCBs shuold be enclosed in a pole/ wall mounted rust proof, electric shock proof, termite proof and FR grade thermoplastic polycorbonate enclosure ( with hinged lid) conforming to IP-66 production class-II of suitable size to accommodate all panels accessories- 01 Job. Make - Hensel/syntex. (d) MCB TPN 40 Amps, B- curve, conforming to IEC-60898/IS-8828-02 Nos. Make- Hager/Schneiders/L&T.
(e) All Control cables wirring inside the panel should be of copper conductor, multistranded, PCV insulated, FRLS, 1100 Volts grade of size 10 sqmm, single core followed by colour coding and lugs/thimbles. Make- Finolex/Polycab/Plaza. (f) All equipments should be mounted on suitable size insulator. Make of complete Panel : Healer Enterprises, Model No Swadeep-66-5KW1P Note : Rate should be incl taking down Existting street Control switch.
VIMAL TRADERS AND SUPPLIERS
Ms Salaria Builders
ASHISH AND CO
M/S TRADE LINK
RAVI KUMAR
M/S LIBE & CO
Sona Enterprises
N K BUILDERS
KAMLA CONSTRUCTION COMPANY
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .