Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹42.9 L+₹6.3 L (17.1%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹43.4 L+₹6.8 L (18.7%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹45.0 L+₹8.4 L (22.9%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹48.0 L+₹11.4 L (31.1%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹46.7 L
EMD Value
₹93,400
Closing Date
5 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
Provision of certain sanctioned works (10) of E/M nature under GE (N) Ahmednagar
2022_MES_506512_1
8591 / E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Ahmednagar
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹93,400
Yes
6 Apr 2022
8 Feb 2022
7 Mar 2022
8 Feb 2022
5 Mar 2022
21 Feb 2022
60 days
Amount
S&F low level PVC flushing cistern incl bracket & PVC flexible pipe for connection to GI pipe 10 ltr capacity fixed in repairs etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs grating 100 mm dia of PTMT etc complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames not exc 1.5 Sq m but with shutters (without taking off shutters from the frames) etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 3 (here-in-before) exc 1.5 Sq m but n exc 4 Sq m each
Taking down shutter exc 1 Sqm but n exc 2 Sqm each etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix 35mm thick second class hard wood plain framed factory made panelled shutters, two panel with lock rail and panel of 9mm BWP commercial ply. The size of rail and style as per IS 1003 (Part I) kiln seasoned and chemically pressured treated. etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix 35 mm thick factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) etc complete all as specified and directed by Engineer-in-Charge.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with ms tube suppling & fixing in position as per specification & drawings. etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Factory Made Solid PVC Moulded Door Shutter, with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm Plain colour PVC Sheet on back face etc complete all as specified and directed by Engineer-in-Charge.
S&F galvanised MS wire cloth 0.56 nominal dia of wire & average width of aperture 1.18mm & fixed with tinned tacks or galvanised wire staples etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 11 (here-in-before) but in repair etc
Supply and fix mild steel butt hinges medium weight cold rolled of size 100mm etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix aluminium anodised barrel tower bolt of extruded section 150mm long etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section of cast aluminium alloy and fixed 300mm long etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix aluminium anodised handles of extruded section 150mm long etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair brass ,CP toilet paper holder fixed to wall with brass CP screws etc complete all as specified and directed by Engineer-in-Charge.. Cat part No ER-0916OF PLUMBER
S&F vitreous china wash down water closet (pedestal pattern) coloured incl fixing bolts seat cover etc fixed in repairs etc complete all as specified and directed by Engineer-in-Charge.
S&F Wash hand basin white vitrous China 550 x 400 mm incl brackets (flat back or angle back) type incl cutting & pinning in ends of brackets or errecting stand incl piller tap, waste pipe coupling PVC connection etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs hand shower (Health faucet) (Hand Shower) with 1mtr flexible tube 8 mm dia with wall hook bracket etc, of superior quality etc complete all as specified and directed by Engineer-in-Charge.Make :- Cat part No 573 of Jaquar
Supply and fix in repairs 15mm bore CP brass wall mixture 3-in-1 with provision of both telephonic shower & overhead shower, 115mm long bend type & wall flange etc complete all as specified and directed by Engineer-in-Charge. Cat Part No MSH 1141 (for mixer), MSR 1090 (Over head shower) and MSH 1260 (Shower arm) of MARC or its equivalent makes mentioned in list of makes in Appendix `C'
Supply and fix in repair 15 mm dia bib tap, chromium plated, fancy type, with capstan head, ISI marked screwed downs screwed for iron pipe or for brass ferrule etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair 15 mm dia stop valve, cast copper alloy, chromium plated, fancy type screwed down, high pressure with crutch or butterfly handles screwed both ends for iron pipe or for unions etc complete all as specified and directed by Engineer-in-Charge.
S&F mild steel 300 mm long ordinary rat tail rod pattern spring incl roller and roller plate in repairs etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm dia brass chromium plated shower rose with arm etc complete all as specified and directed by Engineer-in-Charge. Make: Cat Part No MSR-1050 (Shower and MOR 1260 arm of Mark
Cutting chases for concealed water tubing etc complete all as specified and directed by Engineer-in-Charge.
Taking down steel tubing and connections in repairs,15 mm bore etc complete all as specified and directed by Engineer-in-Charge.
All as per Sl item No 27 (here-in-before) but 20mm
Supply and fix GI tubing, 15 mm dia, concelled medium grade with all necessary fittings fixed to walls / ceiling or laid in floors including cutting, threading etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 29 (here-in-before) but 20mm dia
Supply and fix in repair Harrison rails, anodised aluminium alloy etc complete all as specified and directed by Engineer-in-Charge.
S&F tubular towel rail, brass chromium plated 20mm dia D type, 60 cm long between flanges incl a pair of brackets etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair stainless steel kitchen sink with drainage board over all size 950 x 510 mm and bowl size 410 x 410 x 230mm, made out of 1.00 thick SS sheet of high quality incl a pait of brackets, waste coulpling, plug and chain, 32 mm dia PVC flexible waste pipe and nahani trap etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surface and applying two coats of oil bound distemper on walls etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old plastered surface and applying one coat of oil bound distemper on walls etc complete all as specified and directed by Engineer-in-Charge.
M&L for washing, rubbing down and stopping of distempered and painted surfaces on walls and applying 2 coats of cement paint on walls etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for preapration of old treated wood and woodn based surfaces of any description not exceeding 10cm in width or girth and applying one coat of synthetic enamelled paint etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of new wood and wood based surfaces of any description exceeding 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for special treatment to sunken slab floor incl WC trap etc including cleaning and preparing the surface area for carrying out membrane water proofing treatment, then injection grouting the weak areas on the concrete surface with cementitious grout and applying 10mm thick cement plaster in cement and sand mortar (1:4). Then providing and laying Mineral Top APP (Atactic Polypropylene Polymer) modified prefabricated 5 layer 4mm thick water proofing membrane, black finished reinforce with non woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 Litre per Sqm by the same membrane manufacturer of density at 25ºC, 0.87-0.89 Kg per litre and viscosity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torach and sealing all joints etc and preparing the surface complete. and providing PCC 1:5:10 type E2 using 40mm graded mechanically crushed stone aggregates in sunken slab and 75mm thick PCC 1:4:8 type D2 using 40mm graded mechanically crushed stone aggregates as base, 40mm bore GI pipe, light grade of length not less that 50 cm as spout, non-skid glazed tiles as per existing pattern/size/tint with and incl WC viterous china squatting pan 580x440mm with integral footrests/pedastal pan incl seat cover, white, area of WC exc 1.50 Sqm but nexc 5.00 sqm etc after dismantling the existing sunken floor etc etc complete all as specified and directed by Engineer-in-Charge. Note : Work has to be carried out strictly by the authonticated applicator of the manufacturer and as per manufacturers specification as approved by GE.
All as per item No 39 (here-in-before) but area of WC up to 1.50 Sqm
All as per item No 39 (here-in-before) but in Bath area exceeding 1.50 but not exceeding 3 Sqm without considering WC of any type
All as per item No 39 (here-in-before) but in Kitchen (Nahani trap portion) area not exc 0.50 Sqm
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering, 15 mm thick on stone/brick / concrete surfaces in cement and sand mortar (1:4) surfaces finished even and smooth without using extra cement, including WPC @ 3% of weight of cement etc complete all as specified and directed by Engineer-in-Charge.
Material and labour 16mm to 18mm thick pre-polished granite stone slab of approved shade and colour Jet Black / Telephone Black as in top table, top of WHB, kitchen slab/platform, steps, gate pillars, cills, jambs, lintel etc or on vertical surfaces including vertical projection, full round moulding the edge laid over screed bed 15mm thick in cement and sand mortar (1:4) jointing , pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of granite and rubbing polish to achieve mirror finish etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixed in repairs 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 47 (here-in-before) but 75 mm dia
Supply and fix in repairs 110 mm bore PVC (SWR) bend, any radius etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 49 (here-in-before) but 75 mm bore.
Supply and fix repairs PVC (SWR) floor trap, 75 mm dia with grating including jointing with slovent cement etc complete all as specified and directed by Engineer-in-Charge.
S&F for 12 mm thick Veneered decorative plywood, grade I, (with BWR resin) descorative veneers on both faces balancing white lamination, fixed with screws to timber frame work for cupboards of bedroom/kitchen etc complete all as specified and directed by Engineer-in-Charge
Supply and fix Continuous (piano) hinges, mild steel, bright finish or electrogalvanised as in cupboard shutter etc complete all as specified and directed by Engineer-in-Charge
Supply and fix mild Steel 32 mm dia decorative CP curtain rods with fixing brackets fixed in repairs etc complete all as specified and directed by Engineer-in-Charge.
Hacking out old broken glass (any thickness size,quality or description) from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads n'exc 1.5 Sqm etc complete all as specified and directed by Engineer-in-Charge.
M&L for framed work such as guard bars/ grill /gratings etc with ends of bars shouldered and/or riveted or gorged into spikes confroming to FE-290, Gde -E- 165 etc complete all as specified and directed by Engineer-in-Charge.
Dismantling of stone slabs and tiles of any description or thickness in floors, approns etc laid and bedded in any mortar etc complete all as specified and directed by Engineer-in-Charge.
Demolition of plain cement concrete (unreinforced) in ground floor not exceeding 15 cm thick etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for 75 mm thick plain cement concrete (1:4:8) type D2, using 40 mm graded stone aggregate as in sub base etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for rough dressed shahabad stone, 25 mm to 40 mm thick laid over and including 15 mm thick screed bed in cement and sand mortar (1:6), laid and jointed pointed in cement and sand mortar (1:3) etc complete all as specified and directed by Engineer-in-Charge.
M & L for providing water proofing treatment on roofs, as per manufacturere's instructions and as specified after taking down/out as existing out at site etc complete all as specified and directed by Engineer-in-Charge
(a) Cleaning the newly plasterd surfaces with wire brushes and applying a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sqm including cleaning surface etc complete all as specified and directed by Engineer-in-Charge.
(b) Applying and laying torch APP polymer modifiedbituminous membrance 3mm thick with non woven polyster matt as reinforced weighing not less than 3 kg/sqmts by therofusion process as per manufacturers specification including applying one coat of aluminium paint etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for plastering 10 mm in cement and sand mortar (1:3) using 100 % course sand on roof mied with and including WPC @ 3% by weight of cement and finished the surface even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge.
S & F powder coated aluminium frame for fixing doors, windows, ventilaters with one or more rebate with suitable size of screws etc complete all as specified and directed by Engineer-in-Charge
S&F for powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws etc complete all as specified and directed by Engineer-in-Charge
Material and labour for glazing with 5.0 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and directed by Engineer-in-Charge.
M&L for Pre-cast cement concrete block masonry of (1:3:6) type C-1 (20 mm graded stone aggregate) with solid blocks, exc. 10 cm in width complete set in and including cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for false ceiling with Vinyle faced Arm-Gyp-FB, ceiling 600 x 600 x 9mm thick with washable metallized polyster foil backing with Vinyle covered edges, supporting sections shall be of suitable size from same makes embossed on sections and level adjuster duly suspended by 2 mm dia GI wire fixed to roof at 600mm centre to centre as per manufacturere's instructions / specification and etc complete all as specified and directed by Engineer-in-Charge
Excavation in post holes (or similar holes) each not exceeding 0.50 cum in hard/dense soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundations filling and mass concrete etc complete all as specified and directed by Engneer-in-Charge
Supply, fabricate, erect and fix in position mild steel work Fe-410-0 or Fe-310-0 grade, as in fencing post/Struts including drilling holes complete all as specified and shown on drawing etc complete all as specified and directed by Engineer-in-Charge
M&L for mild steel deformed bars 10mm dia & over cut to length bents to shape including cranking, bending spirally for hopping for columns hooking ends & binding with MS wire annealed not less than 0.9 mm dia or security with clips etc complete all as specified and directed by Engineer-in-Charge.
S&F Galvanised 2 strand steel barbed wire 2.24 mm dia, barbed with 2 mm dia barbs at 75mm spacing and straining and fixing to any type of stranded rails includig security securing or typing at crossing all as specified and shown on drawing etc complete all as specified and directed by Engineer-in-harge
Supply only chain link fencing of any size, esh and type etc complete all as specified and directed by Engineer-in-Charge
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire as specified and directed.
S&F 10mm dia MS bolts screw machine made with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut 5 cm long etc complete all as specified and directed by Engneer-in-Charge
M & L for preparing new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and as directed by Engieer-in-Charge
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft loose soil etc complete all as specified and directed by Engineer-in-Charge
Surface excavation n.exc 30 cm deep and averaging 15 deep and getting out in soft / loose soil etc complete all as specified and direted by Engineer-in-Charge
M&L for PCC (1:2:4) type B1 (20mm graded stone aggregate) in coping including form work and bed blocks of hold fast etc complete all as specified and directed by Enginneer-in-Charge
M&L for Hardcore of broken stone or boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:3:6) type C-2 (40 mm graded stone aggregate in sub of floors 75 mm thick etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:2:4) type B-2 (40 mm graded stone aggregate in plinth protection 75mm thick etc complete all as specified and directed by Engineer-in-Charge
M&L for PCC (1:2:4) type B-1 (20 mm graded stone aggregate in floors and finished even and smooth with using extra cement 40mm thick etc complete all as specified and directed by Engineer-in-Charge.
Returning , filling in including in spreading, leveling,watering and well raamming in layers.n exc 25 cm in soft/loose soil etc complete all as specified and directed by Engineer-in-Charge
Removing excavated suplus soil material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point etc complete all as specified and directed by Engineer-in-Charge
Rendering 15mm thick on fair faces of concrete in cement and sand mortar (1:6) and finished even and smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of newly plastered surfaces and applying two coats of cement paint over a coat primer etc complete all as specified and directed by Engineer-in-Charge
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hing etc complete all as specified and directed by Engineer-in-Charge
S&F Welded steel wire fabric supplied and fixed complete to wood or steel members weight exc 4 Kg per Sqm etc complete all as specified and directed by Engineer-in-Charge
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over & including 15 mm thick screed bed in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge.
Dismantling of Manglore pattern roofing tiles with ceiling tiles or slate roofing etc complete all as specified and directed by Engineer-in-Charge
Dismantling of Battens for tiles spacing exc 15 cm distance, shingles etc, of any size including tilting fillets etc complete all as specified and directed by Engineer-in-Charge
M&L Cutting out bricks, forming toothing for, and bonding new into old work including value of new materials entering old walls and jointing and pointing (measured on vertical face in contact with old wall only), in cement and sand mortar (1:6) etc complete all as specified and directed by Engineer-in-Charge
M&L for Forming jambs, etc., to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete in cement and sand mortar (1:4) etc commplete all as specified and directed by Engineer-in-Charge
M&L for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates etc complete all as specified and directed by Engineer-in-Charge
M&L for Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof coverin/cladding t wall fixed with self tapping screwas as specified for valley etc complete all as specified and directed by Engineer-in-Charge
S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified in ridge
M&L for PCC (1:2:4) Type B-1 (20 mm graded stone aggregate) in hold fast blocks and rafter bed blocks and Gola etc complete all as specified and directed by Engineer-in-Charge
S&F for steel windows with side hung double shutters incl projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed by Engineer-in-Charge. Notes: 1. Guard bar shall be measured and paid separetly. 2. glazing shall be measured and paid separetly.
M&L for 3.00 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 sqm in each pane etc complete all as specified and directed by Engineer-in-Charge.
M&L for 12 mm mesh, Wire netting of galvanised steel wire 0.71 mm dia fixed with tinned tacks of wire staples etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of newly plastered surfaces and appying three coats of white wash on wall etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old painted Wood or wood based surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel etc complete all as specified and directed by Engineer-in-Charge
M&L for providing and injecting chemical emulsion for Post Constructional Anti-termite Treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron etc complete all as specified and directed by Engineer-in-Charge
Supply only intergral water proofing compound etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old plastered surfaces and applying one coat of white wash on walls etc complete all as specified and directed by Engineer-in-Charge
M&L for preparation of old plastered surfaces and applying one coat of cement base paint on wall etc complete all as specified and directed by Engineer-in-Charge
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering etc complete all as specified and directed by Engineer-in-Charge
M&L for Kota stone slab 20-25mm thick as in floor laid over and including 15mm thick screed bed in cement and sand mortar (1:6), set & jointed in neat cement slurry and pointed in white or coloured cemnet to match the shade of Kota stone slab including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick backing coat cement and sand mortar (1:4) set and jointed with white or coloured cement to match including rubbing and polishing etc complete all as specified and directed by Engineer-in-Charge
Taking down carefully copper/aluminum point wiring (light/fan/bell/socket, power point etc) complete , including fixture and fitting such as switches, ceilling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfases of walls, floors etc complete all as specified and directed Engineer-in-Chage
M&L for point wiring complete on surface of wall (open) type with two runs of 1.5 sq mm for phase and neutral single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable drawn in and incl PVC Casing and capping ISI Marked with its accessories with provn of PVC boxes and fixed with brass screws cup washer for fixing switches/socket/regulators etc incl 1.5 sq mm single core multistranded copper conductor of 1100 volts grade PVC insulated and unsheathed FRLS cable as earth continuity conductor to common earth & connecting to earth dolly for the following, all as specified and directed. Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. All points are required to earthed upto fixtures i.e. Holders, Tube lights, Wall lights, bulkhead lights, bldg security light etc
One light point controlled by switch 5 Amp single pole one way
One fan point controlled by switch 5 Amp single pole one way
One 3 pin 5 Amp socket outlet on same board controlled by one, one way 5 Amp switch
One socket outlet 5/3 pin 5 Amp controlled by one switch on independent board
All as per Item No 115 (here-in-before) but with 2.5 Sqmm Copper conductor cable for Phase, Neutral and Earth for one 3 pin, 15 Amp socket outlet on independent board
S&F switch piano flush type single pole, one way 5/6 Amp etc complete all as specified and directed by Engineer-in-Charge
S&F Switch socket combination two in one, 5 Amp flush type 230V AC etc complete all as specified and directed by Engineer-in-Charge
S&F Switch socket combination 5 Amp / 16Amp, five in one, 5 / 15 Amp 230V AC etc complete all as specified and directed by Engineer-in-Charge
S & F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required etc complete all as specified and directed by Engineer-in-Charge.
Supply & fixing lamp holder (Angular/Straight ), insulated body, with back plate for batten fitting etc complete all as specified and directed by Engineer-in-Charge
M&L ceiling rose 3 terminal / PVC / polycarbonate, isolated body etc complete all as specified and directed by Engineer-in-Charge
S & F in replacement double door Sheet metal enclosures factory made DBs 4 way TPN, 415 volts ,Including 63 Amps MCCBs protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No:5076 70 or equivalent makes mentioned in list of makes in Appendix `C'
S & F in replacement double door Sheet metal enclosures factory made DBs SPN, 8 way ,240 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand ,Cat No: 5076 11 or equivalent makes mentioned in list of makes in Appendix `C'
S & F in replacement double door Sheet metal enclosures factory made DBs 4 way SPN, 240 volts ,protection class IP-42, suitable for fixing of MCBs, Isolators etc, confirming As per IEC 61439-3 ,Suitable for Flush Mounting and Surface Mounting, With 100 A Copper Busbar ,With Neutral bar, Earthbar and Cable ties for Cable management,Fully shrouded Neutral bars, Prefitted masking sheet complete all as specified and as directed. Make: Legrand Cat No:5076 10 or equivalent makes mentioned in list of makes in Appendix `C'
Supply & fixing MCB , SP, AC, 240 Volts of 06 to 40 Amp capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCBs, TPN, AC, 415 volts of 63 Amps capacity 16 KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply & fixing MCBs, SPN, AC, 240 volts of 40 Amps capacity 16KA, 'C' series and making connections with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge
Supply and fix Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 20 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with and including 2 core sheathed copper conductor cable of size 0.5 Sqmm with complete with all accessories etc complete all as specified and directed by Engineer-in-Charge
S&F Decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack LED Tube light fitiing 10 Watt with LED light source 6500 K with uniform light output, with all accessories including its connection with 2 core seathed copper conductor cable of size 0.5 Sqmm with etc complete all as specified and directed by Engineer-in-Charge
S&F sub main wiring with two single core PVC insulated,unsheathed, FRLS stranded copper conductor cable 4 Sqmm with 4 Sqmm PVC insulated, unsheathed, FRLS stranded copper conductor cable as earth wire drawn through and including PVC Casing and capping ISI Marked with its all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge Note : 1. Porper colour coding shall be adopted for wiring (For Phase- Red, Yellow, Blue, For Earth - Green and For Neutral- Black) 2. Two run of 4 Sqmm cable i.e for one run for phase, one run for neutral with one run of 4 Sqmm cable for earth and one run of PVC Casing & caping shall be measured as one unit
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. Earth pit not less than 2.25 m depth and top edge of the earth plate not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts & washer etc. Earth wire connected upto main earth point / DBs alongwith 15mm dia earth protection pipe from top edge of the earth plate to main earth point to be connected and 20mm dia watering pipe light grade with funnel and provn of PCC using cement concrete (1:2:4) mix type B1 using granded stone aggregate and RCC pit cover 50 mm thick precost RCC (1:2:4) mix type B1 duly reinforced with 8 mm dia of TMT bar @ 100 mm CIC, both way, lifting arrangement complete including all necessary earth work etc complete all as specified and directed by Engineer-in-Charge
M & L for Supply,laying ,connecting ,testing and commissioning and jointing , LT underground cable in replacement ,1100 volts grade, XLPE insulated, armored with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in ducts, fixed on poles/walls with proper size saddles and clamp complete all as specified and as directed by the Engineer-in-Charge of following Sizes :-
(a) LT cable 16 Sqmm, 4 core.
Supply &lay HDPE pipe 40 mm bore for laying of LT cable complete with all accessores etc complete all as specified and directed by Engineer-in-Charge
Supply &lay GI pipe 40 mm bore for laying of LT cable on wall/pole complete with all accessores etc complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement energy saving and environmental friendly long life LED street light 25 Watt (Bldg security light) made up of pressure die cast aluminium housing with mild power LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK07 fixed on wall with GI pipe of suitable dia and all fixing accessories including connecting up with & including twin core twisted flexible copper conductor cable of suitable size of 230V , 50 HZ etc complete all as specified and directed by Engineer-in-Charge Make -Havell's Cat Part: (ENDURAPEARLSL25W MP) ENDURAPEARL- SL25WLED757SASYTOPCMP or equivalent in makes mentioned in list of makes in Appendix `C'
An amount of Rs 1,11,155.00 shall be deducted from BOQ on account of schedule of credit
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .