Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance AT PO JARIDIH BAZAR P S GANDHI NAGAR BOKARO JHARKHAND 829114 | JARIDIH BAZAR | BOKARO | JHARKHAND | 829114 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹9.7 L
EMD Value
₹12,200
Closing Date
2 Mar 2026, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GENERAL MANAGER (EnM)
OFFICE OF THE GENERAL MANAGER (EnM), NEC, MARGHERITA
REPAIRING OF ELECTRICAL WIRING OF EMPLOYEE QUARTERS OF RESIDENTIAL COLONIES OF TIRAP COLLIERY UNDER WELFARE BUDGET 2025-26
2026_NEC_353630_1
TRP/CE/07/2025-26/77
Open Tender
Electrical and Maintenance Works
Percentage
60 days
TIRAP COLLIERY, NEC, MARGHERITA
Please refer Tender documents.
4 documents required · 4 mandatory
₹12,200
3 Mar 2026
19 Feb 2026
3 Mar 2026
19 Feb 2026
2 Mar 2026
19 Feb 2026
19 Feb 2026 - 25 Feb 2026
Wiring for light/fan/ call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system, complete. a) Short point up to 3.00 metre. length.
b) Medium point up to 6.00 Mtr. Length
c) Long point up to 10.00 Mtr. Length.
Wiring for drawing sub-main with PVC insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694:1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex/RR Kabel or its equivalent make as approved by the deptt.) in surface flat 19 mm. ISI marked casing & capping (AKG / Precision / Presto Plast / Polycab / MW or equivalent make as approved by the deptt.) system, including connection as required.a) With 2 X 2.5 Sq. mm. + earth continuity with 1 X 1.5 Sq. mm. in surface flat 19 mm. casing & capping system.
b) With 2 X 4 Sq. mm. + earth continuity with 1 X 2.5 Sq. mm. in surface flat 19 mm. casing & capping system.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) with flat 19 mm ISI marked casing 'n' capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. a) Short point up to 3.00 Mtr. Length.
b) Medium point up to 6.00 Mtr. Length.
c) Long point up to 10.00 Mtr. Length.
Supplying and fixing of Switch & Socket combined (S S combine , (I.S.I. approve (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on existing PVC/ MS board including connection as approved by the Deptt.)complete as required
Supplying and fixing of Plain Pendent holder (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) with twin twisted flexible cable including 11 W CFL lamp and connection as approved by the Deptt.)as required.
Supplying with fitting and fixing single pole 10 KA 240/415 V 50 Hz. MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series. a) 6 Amps to 32 Amps
b) 40 Amps.
Supplying with fitting and fixing DP 10 KA 240/415 V 50 Hz. MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series. 6 to 32 A
Supply of LED Tube Light fitting 20W comlete with all accessories for wall/ ceiling mounting (including lamp)
Supply and installation of 3 phase energy meter
Supplying, fitting and fixing of ceiling fan regulator including connections etc. Complete as required (Electronic Type)
Total impact of GST for the purpose of CTC
stage.html
html • 0.03 MB
finance_366440.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.65 MB
BOQ_366440.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .