Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹97.6 LAccepted-AOC | ₹97.6 L Quoted ₹99.9 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹1.0 Cr+₹5.0 L (4.98%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | ₹1.0 Cr+₹5.0 L (4.98%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹1.1 Cr+₹7.2 L (7.22%)Rejected-Finance | ₹1.1 Cr+₹7.2 L (7.22%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹1.1 Cr+₹8.5 L (8.52%)Rejected-Finance BHAGWATI BHAWAN PO HASIMARA DIST JALPAIGURI PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹1.1 Cr+₹8.5 L (8.52%) | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 5 | L5₹1.1 Cr+₹8.7 L (8.68%)Rejected-Finance 179 143 1 INDA NEAR SHAKTI BHAVAN KHARAGPUR 721305 | MEDINIPUR WEST | WEST BENGAL | 721305 | ₹1.1 Cr+₹8.7 L (8.68%) | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
1 Jun 2020, 6:00 pmClosed
CWE BINNAGURI
HQ CWE BINNAGURI
SPL REPAIR TO OFFRS MD ACCN PO 5A TO PO 5D AND PROVISION OF EXTERNAL SERVICES FOR INFRASTRUCTURE PHASE I AT SEVOKE MIL STN UNDER GE SEVOKE ROAD
2020_MES_342636_1
8010/BIN(SEV)/04/2020-21
Open Tender
Civil Works
Item Rate
150 days
SEVOKE ROAD MIL CANT
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹1,000
GE SEVOKE ROAD
₹1.8 L
Yes
8 Aug 2020
4 May 2020
2 Jun 2020
4 May 2020
1 Jun 2020
26 May 2020
Amount
Schedule 'A'
Taking down cement plaster of any description incl racking out joints, hacking for key, scrubbing down with water etc and removal of debrise out side MD land complete all as specified and directed.
Taking down chowkats or frames exc 1.5 sqm but not exc 4.0 Sqm each with shutters ( with out taking off shutters from the frames) complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) complete all as specified and directed.
Demolition of brick work built in CM including taking out roots vegitation if any at any position and removal to out side Md land complete all as specified and as directed.
M&L Brick work using old size bricks with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work with subclass ‘B’ bricks, straight or curved on plan to any radius in half bricks built in cement motar (1:4) using old size of bricks all as directed.
M&L plastering in CM 1:6 15mm thick finished even and smooth with out using extra cement complete all as specified and as directed.
M&L for rendering 20mm (10+10) thick in CM 1:4 using WPC @ 3% by weight of cement as per manufacturers instructions complete all as specified and as directed (Note : Water proofing compound shall be measured and paid separately )
M&L for rendering 5mm thick in cement mortar (1:3) to ceiling and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for 3mm thick wall care putty on internal surface of wall new / old surface complete all as specified and as directed.
S&F Second class Hard Wood (SAL/Hollock/Kalasiris) plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints etc complete all as specified and directed.
Refixing in the same opening of shutters of any description exceeding 2 sqm each complete all as specified and as directed.
S&F in repairs 35 mm thick Flush shutters, solid core, construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
M&L for preparation of new wooden surface of any description over 10 cm in width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F Butt hinges, stainless steel 100 mm long complete all as specified and directed.
M&L for Aluminium alloy anodised barrel tower bolts 150 mm long complete all as specified and directed.
S&F 250 mm length aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy of bolt complete all as specified and directed.
S&F aluminium anodized bow handles of 150mm size, fabricated type of extruded section fixed with screws to shutters, complete all as specified and as directed.
S&F expanded metal cut to length bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised and fixed to wood or steel members, weight n. exc. 4 Kg per Sqm complete all as specified and as directed.
Supply only integral water proofing compound (ISI marked) of approved make/brand complete all as specified And as directed.
M&L for PCC 1:2:4 type B-1 cement concrete as in press steel chowkat, bed blocks for hold fasts etc including provision of necessary form work complete all as specified and as directed.
S&F mild steel work in framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screw, including bending and welding angles as necessary gusser plates, riving etc n.exc. 10 Kg each brackets confirming to Fe-290 Gde -165 complete all as specified and as directed
M&L for 75mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate, in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed. Note : Joints 12mm wide to the full depth of PCC shall be provided at every 3 meters and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. Cost of this provision shall be deemed to be included in the quoted rate for concrete in plinth protection.
Taking up or down steel water tubing and connections of size 15mm bore pipe complete all as specified and directed.
All as per item No 24 here-in-above but 20mm bore complete all as specified and as directed.
All as per item No 24 here-in-above but 25mm bore complete all as specified and as directed.
S&F of CPVC pipes SDR 11 of size 16mm internal dia & plain CPVC SDR 11 fitting on walls / ceiling or laying floors complete all as specified and as directed.
All as per item No 27 here-in-bore but 20mm bore
All as per item No 27 here-in-bore but 25mm bore
S&F in repairs 15mm bore bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
Dismantling CI / PVC soil waste pipes of any length and any size including fittings and cutting of holes whever required, complete all as specified and as directed.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S & F 110 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified & directed.
S & F 110 mm bore PVC (SWR) Vent cowl complete all as specified & directed
M & L for apply two coats of oil bound distemper with roller over one coat of primer, after preparation of new surfaces of walls etc, complete all as specified and directed.
M&L for complete removal of existing treatment of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including washing down water etc. apply two coats of oil bound distemper with roller over one coat of primer, complete all as specified and directed.
Preparation of new wooden surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint,desigen and pattern as approved by engineer in charge complete all as specified.
Preparation of old painted wooden surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint,desigen and pattern as approved by engineer in charge complete all as specified.
M&L for preparation of new decorated surfaces of wall and applying two coats of antifungal exterior paint (of shade/colour as directed by GE) over one coat of primer all as per manufacturer instruction including necessary scaffoldings etc. complete all as specified and directed.
M&L for complete removal of existing treatment of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including washing down water etc. applying two coats of antifungal exterior paint (of shade/colour as directed by GE) over one coat of primer all as per manufacturer instruction including necessary scaffoldings etc. complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying three coat of white wash, complete all as specified
M & L for preparation of old plastered surfaces of ceiling and applying two coat of white wash, complete all as specified
M & L for removing loose, disturbed or disintegrated old concrete surfaces of RCC beam, column, lintel, pardi, railing etc, cleaning thoroughly exposed reinforcement, by sand blasting using suitable pump as directed by the GE, preparing exposed concrete surfaces to receive guniting, applying one coat of anti corrosive paint to the exposed reinforcement, supply and fix welded wire mesh of size 100 x 100 mm of 3 mm dia wire, weight not less than 1.37 Kg/Sqm & binding with 22 guage mild steel (annealed) binding wire to reinforcement and applying pressure guniting in cement mortar 1:3, minimum thickness 30 mm and thereafter rendering 10 mm thick plaster in cement mortar 1:3, mixed with water proofing compound @3% by weight of cement and finishing the surfaces even and smooth without using extra cement to match with the existing surfaces, removing the debris outside MD land including material and labour for necessary scaffolding and safety arrangement for guniting work, complete all as specified and directed. (Note :- The finish of the surfaces to be matched with the existing surface. WPC shall be measured & paid separately as supply only).
S & F TMT steel bars to 8 mm dia cut to length bent to shape required including cranking bending spirally hooking ends and binding with MS wire of dia not less 0.9 mm complete all as specified
S& F TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for Reinforced cement concrete (nominal mix) TypeB0 1:2:4, (12.5mm graded aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam hunchings,girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. Complete all as specified and as directed.
S&F in repair 25 mm dia gun metal, globe or gate valves complete all as specified and directed.
Dismantling water tanks from the position 1000 ltrs capacity complete all as specified and directed.
Dismantling water tanks from the position 500 ltrs capacity complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks, double layered(ISI marked) of 1000 ltrs capacity(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, including provision of necessary fittings for connection the overflow, drain out, inlet and outlet pipes, complete all as specified and as directed.
S&F rotational moulded polyethylene water storage tanks, double layered(ISI marked) of 500 ltrs capacity(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, including provision of necessary fittings for connection the overflow, drain out, inlet and outlet pipes, complete all as specified and as directed.
S&F in Plain, Aluminium sheeting,0.71 mm thickness Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (as in crumple joints) complete all as specified and as directed.
Demolition of brick coba/cement concrete (unreinforced) from existing roof/terrace etc and also removing/taking down of existing water proofing treatment of any thickness in any position including cleaning the surfaces of roof etc with wire brush complete and removing the retrieved debris in low lying area, all as specified and directed.
M&L for PCC (1:2:4) type B-0, using 12.5mm graded stone aggregate as in leveling course over RCC roof surface to achieve required slope including making rounded or chamfered on edges mixed with WPC @3% by weight of cement, complete all as specified and directed. Note : WPC shall be measured and paid separately as supply only.
Demolition of lime concrete or lean concrete from sunken floor including floor tiles, hacking of surfaces after cleaning with wire brush (floor and adjoining walls) and disposing off debris outside MD land complete all as specified and directed.
Treatment of sunken floor slab comprises of the following specifications and all as specified.:- (i) M&L for cleaning the sunken/ lowered portion of RCC slab surface (including vertical total depth plus skirting height ) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely . 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding conc to achieve proper slope includiing cutting holes in bricks or RCC wall for spout (Cost cutting holes and pipes shall be measured and paid separately (ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/ seepage is noticed , nozzles shall be fixed and grouting carried out (WPC shall be measured and paid separately ) (iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty (iv) After drying putty , wash the slab and sides of sunken portion with water and make it clear and clean. (v) M&L for applying two coats of polymer modified cementious water proof coating as per manufactures instruction to bottom and vertical sides up to finished floor level +100mm height . The thickness of two layer shall be 1mm . When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (This item shall be measured and paid separately) (vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout ( WPC Shall be measured & paid separately) Note :- Test the water proofed area (ponding test ) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE . Test shall be done in presence pf reps of PMG and record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing in include in the rates quoted above. (vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint (Black Japan shall be paid separately)
M&L for coloured Non-sked ceramic tiles 7 to 8 mm thick (square /rectangular) approved size, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc, set and jointed in near cement slurry and pointed in white cement mixed with pigment to match, over and including 20mm thick cement mortar screed bed in CM 1:6 etc, complete all as specified and directed.
M&L for coloured 300x200x7mm thick glazed ceramic tiles on vertical surfaces such as skirting, dado and risers to steps etc, set and jointed in near cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thick cement mortar backing coat in CM 1:4 etc, complete all as specified and directed.
Cutting holes in bricks or RCC walls exce half brick built in cement mortar including making good after inserting and setting spouts all as specified.
GI pipe 50mm dia medium grade laid on sunken floor complete all as specified and directed by EIC
Supply only applying two coats of polymer modified cementious water proof coating as per manufactures instruction to bottom and vertical sides up to finished floor level +100mm height . The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.
M & L for 4 mm thick APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufactured by the same manufacturer as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface. (b) Laying APP modified water proofing membrane reinforced with non woven polyester fibre weight not less than 160gm/Sqcm using butane torch by torch application with 10cm side lap and 15cm end lap. (c) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.50 Kg/Sqm. (ii) Non woven polyester weight not less than 160gm /sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650N/Sqcm and transverse not less than 450 N/Sqcm. (v) Tear strength-longitudinal not less than 300 N & transverse not less than 250 N. (vi) Elongation : > 20% in both directions. (vii) Impermeability/water tightness at 2 Kgf/cm2. (viii) Water absorption - Not more than 1% on mass within 24 hours. (ix) Cold flexibility - Minimum (-) 20C. (x) Dimensional stability % change = Maximum 1%.
Hydraulically machine pressed cement concrete tiles of size 300x300X20mm thick (with grey cement and no pigment), set in neat cement slurry laid over terrace and roofs etc including provision of 15mm thick cement screed bedding layer in CM 1:4 mixed with integral water proofing compound, tiles joints shall be grouted and immediately after grouting, the joints shall be pointed flush in CM 1:3 (in separate process) mixed with integral water proofing compound etc, complete all as specified and directed. (Note : Integral water proofing compound will be measured and paid separately as supply only).
M&L for applying one coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm over APP roof membrane, complete all as specified and directed.
Supply installation, commissioning and testing of transformer copper wound step down 315 KVA outdoor type 11/0.433 KV at no load 3 ph, 4 wire 50 HZ AC with oil immersed naturally cooled, delta connected on HV side and star connected in LV side in accordance with vector symbol DY-II with neutral brought out on secondary side and having tapping in step of ± 2 ½ %, ± 5% and ± 7 ½ % to be changed by mean of hand operated OFF load tap changing gear including first fill of transformer oil as per IS-335, and including all fittings/accessories as specified in SSR Part I and IS-1180 with EEL2 (Energy efficiency level) , the transformer should have cable box on LT side and brass bushings on HT side, oil temperature gauge, dehydrating breather with first fill of dehydrating agent, oil conservator tank, explosion vent, rating and terminal marking plate, oil level gauge, oil drain and filter valve, providing independent earthings and neutral fittings, lugs and two earthing terminal etc,complete in all respect and all other standard accessories all as specified comprising with the following:- (i) 01 No cable box on LT side consisting of 03 Nos porcelain bushing with bushing brass rod and nuts washers etc. (ii) HV bushing with arching horn on 11 KV side. (iii) Oil conservator with filter type drain valve and oil level fuage. (iv) Dehydrating breather with first filling of Dehydration agent.(v) Explosive vent. (vi) Thermometer pocket. (vii) Two Earthing terminal on tank body to facilitate fixing of 32x6 mm GI strips. (viii) One No thermometer dial type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature gauge: Max reading painted terminal. (ix) Rating plate with terminal plate. (x) Oil level guage . (xi) Oil draing filter valve. (xii) Oil filing port on top cover with plug. (xiii) Air release valve/plug. (xiv) 4 Nos plain solld cast steel detachable rollers. (xv) First fill of transformer oil conforming to relevant ISI and tested upto 60 KV dielectric strength. (xvi) Inspection cover. (xvii) Lifting lugs and jack lifting pad support. (xviii) Bi-directional plan/falnged rullers. (xix) Explosion vent with double diaphragm and sight glass. (xx) Hand hole of sufficient size to assess the interior of the tank. (xxi) Cover lifting eyes. (xxii) Necessary fencing, gate and gravel filling in switch yard area all as directed. Note:- (i) Transformer shall be plinth mounted of suitable size for mounting of 315 KVA caoacity transformer and necessary PCC staging required for mounting of transformer is included rate quoted by the contractor. The height of the transformer stage shall not be less than 1.2 Mtrs and all as specified. (ii) The contractor shall arrange factory visit as detailed by accepting officer to check the above system.
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep soft/loose type of soil getting out and leveling of bottom surface to required level for cable/stay complete all as specified and as directed.
Excavation in trenches not exc 1.5 Mtr wide and not exc 2.0 Mtr deep hard/dense type of soil getting out and leveling of bottom surface to required level for cable/stay complete all as specified and as directed.
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep hard rock type of soil/road/PCC getting out and leveling of bottom surface to required level for poles/stay assembly/cable complete all as specified and as directed.
Returning, filling in, including spreading,levelling,watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed.
Supply and fix GI pipe 100mm light grade for cable protection complete complete all as specified and as directed.
Supply and fix GI pipe 50mm light grade for cable protection complete complete all as specified and as directed.
Supply & laying in trenches clear sand for cushioning under cable 8 cm below and 15 cm above complete in level all as specified and directed by Engr-in-Charge.
M & L precast concrete cable covers class HV, type I flat, size 300x180x40mm perpendicular to the axis for the cable in trenches for protection to cable complete all as specified and as directed.
Supply & laying sub class "B" bricks in trenches for protection to cable complete all as specified and as directed.
M&L for of steel tubular swaged poles complete with cast iron base plate, finial taper plug bolts, nuts & screw as specified type 410 SP-31, 9.0 meter long all as specified and directed by Engr-in-Charge.
M&L for steel tubular swaged HT poles complete with cast iron base plate, finial taper plug bolts, nuts & screw as specified type 410 SP-55, 11.0 meter long all as specified and directed by Engr-in-Charge.
M&L for PCC 1:3:6 (40 mm graded aggregate) Type C2 for foundation of pole, stay surface channel incl necessary formwork where reqd complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 coping 20 mm graded aggregate for grouting, benching of drain complete all as specified and as directed.
M&L for PCC (1:4:8)(40 mm graded aggregate) Type C2 for base foundation of pole, stay incl necessary form work where reqd complete all as specified and as directed.
S&F in LED security light fittings of 70W, die cast Al body with IP 66 protection with high powered LED as light source with integrated driver and surge protection complete all as specified and as directed.
M&L for street light bracket made out of MS angle/flat/pipes suitable for fixing of street light complete all as specified and as directed.
M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings, complete all as specified and directed.
Supply and fixing thermoplastic cable junction box having protection IP 66/67 "weather proof" for outside installation with knockout entry for cable of size 10 sqmm and 155x210x92mm with terminals and provision of one 6A MCB SP complete with all brackets and fixing arrangements complete all as specified and as directed. (Make : Hensel / Syntex Industries Ltd)
Supply, laying, connecting and testing HT underground cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cable heavy duty with stranded aluminium conductor 11000 volts grade earthed, laid in trenches/pipes/ducts/trenches/under road of size 95 sqmm, 3 core complete all as specified and as directed. NOTE : Specification of cable shall be as under:- (a) Inner sheathing shall be of extruded PVC. (b) Cable shall also be supplied with sequences hall marking at every metre on the inner sheathing. (c) Ultra violet radiation resistance compounded comprising to ASRM-2863 flame netarded as per EIV specification. (d) Anti rodent and antitermite compound added. (e) PVC compounds of various grades as IS-5831. (f) Compaction conductors shall be shaped and arrangement to the same will be on the cable.
Supply, lay and testing cable XLPE insulated screened PVC bedded, galvnized steel strip or wire armoured , electric power cables (heavy duty)1100 volts grade with stranded aluminium conductor of size 300 sqmm x 3.5 core complete all as specified and as directed. NOTE : Specification of cable shall be as under:- (a) Inner sheathing shall be of extruded PVC. (b) Cable shall also be supplied with sequences hall marking at every metre on the inner sheathing. (c) Ultra violet radiation resistance compounded comprising to ASRM-2863 flame netarded as per EIV specification. (d) Anti rodent and antitermite compound added. (e) PVC compounds of various grades as IS-5831. (f) Compaction conductors shall be shaped and arrangement to the same will be on the cable.
All as per item No 88.00 here-in-above but size 120 sqmm x 3.5 core complete all as specified and as directed.
All as per item No 88.00 here-in-above but size 95 sqmm x 3.5 core complete all as specified and as directed.
All as per item No 88.00 here-in-above but 35 sqmm x 3.5 core complete all as specified and as directed.
All as per item No 88.00 here-in-above but 16 sqmm x 4 core complete all as specified and as directed.
Supply and fixing cable route indicator made of PCC marked showing HT UG cable route including necessary foundation work complete all as specified and as directed.
Supply and fixing Cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape of size as indicated for directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 95 sq mm of make denson item code XSO-12 complete all as specified and as directed.
M&L for aluminium conductor steel reinforced (ACSR) for overhead HT/LT line complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore light grade galvanized steel tubing up to 7.5 mtr length for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed.
M&L for earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to copper earth strip 20 x 3 mm by means of bolts, nuts, check nuts, and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore light grade galvanized steel tubing up to 7.5 mtr length for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron earth wire 4 mm dia by means of bolts, nuts, check nuts, and washer of galvanized iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with cast iron funnel and wire mesh, 40 mm bore light grade galvanized steel tubing up to 7.5 mtr length for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion complete all as specified and as directed.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x3mm aluminium strip complete all as specified and as directed.
S&F lightening arrester non-linear metal oxide type, complete with all fittings, transmission / distribution class, discharge capacity 10 KA suitable for 11 KV line out door type including necessary connection and fittings all as per IS-3070 Part-III and IEC 1994 complete all as specified and as directed.
Supply, install, testing & commissioning of gang operated device (GOD), triple pole, current rating 400 amps, HT 11 KV vertical, mechanically operated mounted on insulators and steel frame with operating mechanism operated from ground with and including jumper connection with ACSR conductor along with PVC pipe covering with colour code between main supply and GOD complete all as specified and as directed
M&L for swing out expulsion fuse single pole (drop out fuse) with porcelline/ rezin cast insulators and brass metal parts for 11000 volts of capacity 100amps complete all as specified and as directed
M&l for pin type porcelain/polymer, vitreous, white, brown or green insulators including one GI spindle, two galvanized iron washers and one galvanized iron nut, 150 mm dia suitable for working pressure 11 KV insulators complete all as specified and as directed by Engr-in-charge.
Material and labour for spreading 40 mm graded stone aggregate in layers n.exc 15 cm thick around the 2 pole/ 4 pole structure, in power house at different area complete all as directed by Eng-in-charge.
S&F danger notice plate of size 25x20cm of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT conforming to IS-2551 complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and as directed.
M&L for finishing fair concrete surfaces with using extra cement complete all as specified and as directed.
Extra forming fair finished drain or channel 30 CM inner girth in cement concrete, using extra cement including forms, moulds, mitred / stopped and etc complete all as specified and as directed.
Supply laying, jointing and testing galvanised iron tubing,medium grade with all fittings such as bends, elbow, tee socket reducers, unions flanges etc as required at site laid in trenches complete all as specified and directed for the following size :- 25mm bore
All as per item No 112.00 here-in-above but 40mm bore complete all as specified and as directed.
All as per item No 112.00 here-in-above but 100mm bore complete all as specified and as directed.
S&F fun metal gate / globe valve, ISI Marked, with iron wheel headed screwed both ends for pipe complete all as specified and as directed for following size :- 50mm bore
All as per item No 115.00 here-in-above but 25mm bore complete all as specified and as directed.
All as per item No 115.00 here-in-above but 40mm bore complete all as specified and as directed.
Cutting of existing cast iron / DI pipes upto 150mm bore dia in any position for insertion and fitting of new Tee, Coller, Tail pieces etc for taking out connections, branch connection complete all as specified and as directed.
S&F fixing and testing cast iron fittings for spigot and socketed or flanged pipes i.e bends, reducers, tail pieces, tapers tees, collars, caps, plugs with MS plate, nuts, bolts, washers gaskets etc or size 150mm dia complete all as specified and as directed.
S&F sluice valve PN 1.6, 100mm bore dia with stainless steel spindle nuts, bolts, washers and rubber gasket sheet for packing sluice valve fixed at any position complete all as specified and as directed.
M&L for construction of valve chamber with MS sheet cover 3mm thick with angle iron frame of size 50X50X60mm and locking arrangements including excavation and earth work in any type of soil, PCC (1:4:8) type D2 in foundation, PCC benching 1:2:4 type B-1, PCC (1:5:8) block masonry 20cm thick in cement mortar (1:6), 10mm thick plastering in CM 1:4, PCC bed in (1:3:6) and coping 50mm thick in cement concrete 1:2:4 type B1 using 20mm stone aggregate including necessary formwork, painting one coat of red oxide and two coats of bituminious black paint on all steel surfaces as specified and as directed of size 1200mmX1200mmX1200mm (internal dimension) complete all as specified and as directed.
M&L for flush pointing to brick walls in cement mortar 1:3 complete all as specified and as directed.
M&L for horizontal boring through road of size 100mm dia for passing cable through GI pipe complete all as specified and as directed.
M/S R. K. INDUSTRIES
S.N. GHOSH AND CO.
MAA BHAGWATI ASSOCIATES
STAR ENTERPRISES
NIRMAL SALES CORPORATION
SHRI SANJAY KUMAR GUPTA
M/S K.K.TRADERS
M/s KASHMIRA SINGH BARMI AND SONS
M/s Debendra Prasad Gupta
Capital Construction Company
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .