Loading
Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
24 Jul 2026, 5:00 pm
SUPERINTENDENT
AS PER TENDER
EVACUATED CLOSED BLOOD COLLECTION TUBES
2026_RNTMC_571726_1
40/25-06-2026
Open Tender
Miscellaneous Goods
AS PER TENDER
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Yes
AS PER TENDER
₹5 L
Yes
AS PER TENDER
1 Jul 2026
1 Jul 2026
27 Jul 2026
1 Jul 2026
24 Jul 2026
14 Jul 2026
6 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1EVACUATED CLOSED BLOOD COLLECTION TUBES :- | |||||
| 1.01 | 1) Clot Activator for serum with Gel 3.5 ml, 13 x 75mm with yellow cap
• Should be sterile, evacuated and PET and single hand operation for capping and decapping.
• It should be recommended of therapeutic drug monitoring.
• It should be ISO 13485 and US-FDA /European CE approved. Product code should be mentioned which is quoted and supplied to the institution.
• It should be Gamma sterile /EB as per current ISO11137 guidelines.
• Batch wise sterility, Pyrogenicity and Toxicity certificate should be given. | 1 | Each | - | - |
| 1.02 | 2) Evacuated Blood Collection Tube with spray dried K2EDTA with lavender cap
• It should be made of clear latex free polyethylene terephthalate. Size 13 x 75 mm with 3.0 ml(5.4 mg), volume capacity.
• Batch wise sterility, Pyrogenicity and Toxicity certificate should be given
• It should be ISO 13485 and US-FDA /European CE approved. Product code should be mentioned which is quoted and supplied to the institution.
• It should be Gamma sterile /EB as per current ISO11137 guidelines. | 1 | Each | 1 | ₹1 |
| 1.03 | 3) Sodium Citrate Evacuated tube with Tube-in-Tube Technology sealed from the top to avoid citrate leakage for coagulation test with vacuum (with Na citrate - 0.109 MI ,3.2%)
• It should be made of clear latex free polyethylene terephthalate with light blue hemogard, 13 mm x 75mm Vol. 2.7 ml.
• Batch wise sterility, Pyrogenicity and Toxicity certificate should be given.
• It should have Tube-in-Tube Technology for Full Draw Volume that reduced headspace thereby minimize platelet activation and provide accurate APPT result
• It should be ISO 13485 and US-FDA /European CE approved. Product code should be mentioned which is quoted and supplied to the institution.
• It should be Gamma sterile /EB as per current ISO11137 guidelines. | 1 | Each | 1 | ₹1 |
| 1.04 | 4) Evacuated Tube for Silica-clot activator/silicon coated made of clear latex polyethylene terephthalate with hemogard 13 mm x 75 mm, Vol. 4.0 ml.
o It should be ISO 13485 and US-FDA/European CE approved. Product code should be mentioned which is quoted and supplied to the institution.
o It should be Gamma sterile /EB as per current ISO11137 guidelines.
• Batch wise sterility, Pyrogenicity and Toxicity certificate should be given
• Adequate combustion data to prove that it is safe for the environment upon incineration. | 1 | Each | 1 | ₹1 |
| 1.05 | 5) Blood Collection needle 21 or 22 gauge with cap and safety lock for evacuated tube.
• It should be ISO 13485 and US-FDA /European CE approved. Product code should be mentioned which is quoted and supplied to the institution.
• It should be Gamma sterile/EB as per current ISO11137 guidelines.
• Batch wise sterility, Pyrogenicity, Toxicity certificate should be given.
• It should have facility to lock the needle to reduce needle stick injuries and help in one handed use.
• As per CLSI recommendation it should be From Same Manufacturer of Vacuumed blood collection tube and holder. | 1 | Each | 1 | ₹1 |
| 1.06 | 6) Evacuated Tube for spray coated with Sodium Fluoride (3mg.), Na2EDTA (6mg.) made of clear latex polyethylene terephthalate with hemogard 13 mm x 75 mm, Vol. 2.0 ml.
• It should be ISO 13485 and US-FDA/European CE approved. Product code should be mentioned which is quoted and supplied to the institution.
It should be Gamma sterile /EB as per current ISO11137 guidelines.
• Batch wise sterility, Pyrogenicity and Toxicity certificate should be given. | 1 | Each | 1 | ₹1 |
| 1.07 | 7) Evacuated Tube Needle Holder with disposable release button
• It should be ISO 13485 and US-FDA/European CE approved. Product code should be mentioned which is quoted and supplied to the institution.
• It should be Gamma sterile /EB as per current ISO11137 guidelines.
• It should have release button to dispose the needle automatically.
• As per CLSI recommendation it should be From Same Manufacturer of Vacuumed blood collection tube and holder. | 1 | Each | 1 | ₹1 |
| 1.08 | 8) Blood Lancet for high blood flow.
• Medical Grade, stainless steel and polymer blood lancet, super sharp tip for instant incision. Sterile and individually pee label pouch pack.
• Needle gauge and Depth (mm) should be at least 23G x 1.8 mm.
• Blood volume should be 100 – 250µl.
• Batch wise sterility, Pyrogenicity and Toxicity certificate should be given.
o It should be ISO 13485 and US-FDA /European CE approved. Product code should be mentioned which is quoted and supplied to the institution It should be Gamma sterile as per current ISO11137 guidelines. | 1 | Each | 1 | ₹1 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
1-EVACUTED.pdf
Tender Documents • 8.74 MB
BOQ_1017418.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid