Loading…
Loading…
Tender Value
₹10.3 Cr
EMD Value
₹20.6 L
Closing Date
19 Oct 2026, 5:00 pm
KARAN BEHAL
Panipat PHED No. 1
BALANA - PROVIDING SEWEARGE FACILITY AND SEWAGE TREATMENT PLANT AT VILL. BALANA DISTT. PANIPAT BALANA
2026_HRY_550478_1
2026FBB4D70D AA49 454C 9009 B294EAE4FD53573PUH
Open Tender
Civil Works
Works
580 days
BALANA BALANA
BALANA - PROVIDING SEWEARGE FACILITY AND SEWAGE TREATMENT PLANT AT VILL. BALANA DISTT. PANIPAT BALANA
2 documents required · 2 mandatory
₹20,000
₹20.6 L
Yes
26 Sept 2026
26 Sept 2026
19 Oct 2026
26 Sept 2026
19 Oct 2026
26 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1NS ITEMS | |||||
| 1.01 | Providing and Fixing PVC insulated 10 sq. mm copper wire 3.50 core ISI mark for connection of Induction motor including thimble and jointing complete in all respect. | 50 | Per Metre | 100 | ₹5,000 |
| 1.02 | Providing and Fixing PVC insulated 16 sq. mm copper wire 3.50 core ISI mark for connection of Induction motor including thimble and jointing complete in all respect. | 80 | Metre | 100 | ₹8,000 |
| 1.03 | Supply, erection, testing and commissioning of wall mounted electrical panel board with bus bar, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 900 x 1200 mm and 400 mm deep having following accessories:- ( Suitable for 2 no. 20.00 BHP centrifugal horizontal spilit casing induction Motor ) (a) Main switch 150 Amp.1 Nos.. (L and T Siemens, ABB).
(b) CT 100/5 Nos. (AE/KAPPA/ LandT)
(c) Digital Multi Function meter = 2 no.
(d) SPP 1 No. of approved make
(e) Motor starter, star delta 3 Nos. (LandT Simens, AAB)
(f) VSS 1 No. and ASS 1 No. of approved make
(g) Capacity KVAR as per site requirement = 3 No.
(h) Indicating Lamp-One Set
(i) Change over switch 150 Amp. = 21 No. each | 2 | Each | 100 | ₹200 |
| 1.04 | Supply ,erection,testing and comissioning
horizontal non-clog sewerage pump 1500
LPM x 35 mtr.Head with 20.00 BHP
induction motor and complete all accessories | 2 | Each | 100 | ₹200 |
| 1.05 | Construction of HT/LT Panel room, including doors, window and fitting with toilet block including sanitary fittings etc. at MPS covered area with RCC framed structure of brick work vitrified glaze tiles flooring, powder coated aluminum frame of size 100mm x 45mm of 10 gauge for chowkhat frame, 75mm x 45mm of 10 gauge for door frame, 45mm x 45mm of 10 gauge for window frame, 5mm thick glass AIS/Saint Gobin/Modi Float, covered area 50 sqm. | 50 | Sqm | 100 | ₹5,000 |
| 1.06 | Construction of HT/LT Panel room, including doors, window and fitting with toilet block including sanitary fittings etc. at STP covered area with RCC framed structure of brick work vitrified glaze tiles flooring, powder coated aluminum frame of size 100mm x 45mm of 10 gauge for chowkhat frame, 75mm x 45mm of 10 gauge for door frame, 45mm x 45mm of 10 gauge for window frame, 5mm thick glass AIS/Saint Gobin/Modi Float, covered area 50 sqm. | 100 | Sqm | 100 | ₹10,000 |
| 1.07 | `CC TV CAMERAS: Providing and Installing 6 CCTV
Cameras (4 Cameras for STP and 2 Cameras for MPS)
complete as per satisfaction of the Engineer-In- Charge,
within 96 hours of signing the Agreement along with 90 days
recording (DVR), 32 inch LED Screen, 16 Channel DVR at
STP Site and 8 Channel DVR at MPS Site with connectors,
cables, poles and power supply with online real-time output
facility. The cameras at both the sites i.e. MPS and STP shall
be synchronized at STP site.
At STP and MPS Site- 1 No. PTZ speed dome 360 degree
50X zoom camera, 3 No. 12 mm lens size, 1 Nos. 3.6mm lens
size.`
Make: CP Plus Internet Protocol minimum 5 MP WDR, Night
vision color mode 2.4.2 12 mm very focal with extra IR, CCTV
Cameras should be installed and commissioned before
starting execution of work | 1 | Job | 100 | ₹100 |
| 1.08 | SEWAGE TREATMENT PLANT `Design, construction, erection, testing and commissioning of 1.00 MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor (SBR) Technology complete in all respect including. Landscaping, MCC Panel Room and all other contingent Electrical, Mechanical, Electromagnetic Flow Measurement Device on inlet and outlet, Real Time water quality monitoring with Data collection system (Online analyzer) Piping and Instrumentation works with PLC and SCADA Arrangement for STP and MPS along with Synchronizing it with each other Including furniture and laboratory equipment as per detail given in the bid document and including following components. 1. 2 No. High Mast of 9 mtr. GI Octagonal pole of 4 mm thickness (T=100 MM, B=200 MM, Base Plate320x320x20mm), window at 500 mm from Base Plate) 12 Nos. Providing and fixing of Solar light 30 watt with dark and motion sensor, 2 level intelligent dimming after 3 and 6 hours of operation, IEC certified solar panel, LM80 certified LED, IP 65 complaint design to protect from rain and dust and UL certified lituimion battery with 2 year system warranty of 6 Mtr. GI pole complete in all respect, along the road and path complete in all respect. 2. Supply and installation of 1 No. Main Gate of (MS) 3.65 m wide main gate and 1.25 m wide wicket gate (total weight not less than 500 kg at STP site. As per satisfaction of Engineerin-Charge. 3. Providing and installing 2 No. centrifuges (1working plus 1 Stand bye) including centrifuge feed pump, all fittings. instrumentations, electric panel board etc. as per design complete in all respect, including packing dry sludge in 20 kg Bag and supplying the same in Market Kisan Sewa Kendra or as directed by Engineer-in-charge within lead as posited as clause 4.4.5 of NIT. including Operation and Maintenance cum defect liability period for 06 years after successful completion of 3 Months trial run period. | 1 | Job | 100 | ₹100 |
| 1.09 | ONLINE OUTLET EFFLUENT WATER QUALITY MONITORING SYSTEM- Supply, Installation, Testing, Commissioning, of effluent quality monitoring system at 1.00 MLD capacity STP for online (continuous) measurement of PH, Total Suspended Solids (TSS), Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD) by single analyzer with various sensors (spectral measurement in the UV-VIS range 200-720mm) performing reagent and chemical free analysis with automatic cleaning of censor, signal cables and power cables, local data acquisition and display of data on continuous basis for up linking the data to CPCB, HSPCB and PHED, TUV approved complete in all respect as per Central Pollution Control Board (CPCB) guidelines for online continuous monitoring system for effluents and as contained in scope of work in the DNIT. a) Multi-parameter measuring converter, for connecting up to 18 intelligent sensors Scope including 8 analog inputs / outputs (4 inputs and 4 outputs) (0/4- 20Ma), wide- range power supply Optical COD/BOD and TSS probe with spectral processing of the UV-VIS range, for measurement in the outlet / effluent of 1.00 MLD capacity STP with integrated with automatic cleaning. b) Robust digital pH/ORP sensor for pH/ORP electrodes, with built-in preamplifier and temperature sensor with Automatic Temperature Compensation (ATC) Cable length 100 Meter (minimum). c) Sensor adapter cable for all intelligent sensors, with IP68 water proof connection to the intelligent Sensor Net system. Cable length 100 meter (minimum) d) Data transfer to CPCB, HSPCB and PHED servers. e) Providing GSM 3G, 4G modem with mobile network connectivity. including Operation and Maintenance cum defect liability period for 06 years after successful completion of 3 Months trial run period. | 1 | Job | 100 | ₹100 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.87 MB
BOQ_630255.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .