| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC NAMBLABAL PAMPORE DISTRICT PULWAMA JAMMU KASHMIR 192121 | PAMPORE | PULWAMA | JAMMU KASHMIR | 192121 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹32.2 L+₹3.7 L (12.9%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹33.4 L+₹4.9 L (17.4%)Rejected-Finance 15 BAGHE ISLAM NEAR NH BY PASS BRIDGE LAL NAGAR CHANAPORA SRINAGAR JAMMU KASHMIR 190015 | SRINAGAR | JAMMU AND KASHMIR | 190015 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹33.8 L+₹5.3 L (18.7%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹33.9 L+₹5.4 L (18.9%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
26 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GE 970 EWS C/O 56 APO PIN 913970
REPAIR AND MAINT OF EXT ELECTRIC INCL LT OHT LINES LT PANELS MCCBS LT POLE STREET PERIMETER LIGHTS ETC AT JAK LI RC UNDER GE 970 EWS
2022_MES_560327_1
GE 970 EWS-51/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE 970 EWS C/O 56 APO
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 970 EWS
₹90,000
Yes
6 Mar 2023
29 Oct 2022
28 Nov 2022
29 Oct 2022
26 Nov 2022
12 Nov 2022
Amount
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for taking out or laying of cable in soft/loose soil and getting out compete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50m where directed at a level not exc. 1.5M above the starting point complete all as specified and directed
Sand cushioning to underground cable with clean dry sand locally available 8cm thick before laying the cable and 15cm above the cable,stretching and testing of cable lcomplete all as specified and directed. Note : For payment purpose , punned thickness shall be measured and paid.
Brick protection with brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches with width of brick parallel to the length of cable complete all as specified and directed.
M&L PCC 1:4:8 type B2 (using 40 mm graded stone aggregate) as in foundation of pole & stay complete all as specified and directed.
M&L PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in filling of pole & stay complete all as specified and directed.
M&L PCC 1:2:4 type B2 (using 20 mm graded stone aggregate) as in coping of pole complete all as specified and directed.
Supply and fix in repair ACSR conductor including stringing on LT poles complete with and including aluminium binding wires, jumpering, bindings at insulators etc complete all as specified and directed.
Cross arm, bracings, supports , clamps and back plate fabricated from structural steel section, including nut , bolts , washers, welding , bendings cold or hot, drilling hole for both in any shape or size as indicated or directed and inclusive of one prime coat of red oxide primer, one under coat and one finishing coat of synthetic enamel paint including taking down the old unserviceable cross arms complete all as specified and directed.
Taking out old unserviceable steel tubular/RCC poles 9 mtr long and supply and erection of steel tublar swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc incl painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle all as specified and directed by Engr-in-Charge.
Disconnecting the windings of loose overhead conductors of LT lines from insulators and restringing the same for proper sag and rewinding including aluminium winding wires, tapes etc and jumpering for any type of conductor complete of single run conductor complete all as specified and directed. Note: Quoted rate shall deemed inclusive of triming of tree branches around the poles upto 3 mtr and nothing extra shall be admissible on this account.
S&F in repair insulator pin type porclain vitereous , white brown or green insulator including one galvanised mild steel spindle, two galvinised washer and one GI nut 100 mm height and 65 mm dia for 1100 Volt grade complete all as specified and directed.
S&F in repair insulator shackle type, porclain, vitereous, white brown or green insulator including one galvanised mild steel straps, washers, insulator bolts, washer and nuts for working pressure 1100 Volts height 100mm, dia 115mm, section of strap (31x5) mm dia of bolt 14 mm complete all as specified and directed.
S&F in repair loop type insulator vitreous porclain white, brown or green of size 65x90 mm overall dimension and 16mm clearance of hole complete all as specified and directed
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls including taking down old unservicable cables, complete all as specified and directed for following sizes of cable :- Note:- Excavation, Earthwork, sand cushioning and brick protection shall be measured and paid for separately.
10 Sqmm 2 Core.
16 Sqmm 2 Core.
16 Sqmm 4 Core.
25 Sqmm 3.5 Core.
35 Sqmm 3.5 Core.
50 Sqmm 3.5 Core.
70 Sqmm 3.5 Core.
95 Sqmm 3.5 Core.
120 Sqmm 3.5 Core.
Material and labour in repairs for stay strand size 7/4 mm complete all as specified and directed
Material and labour in repairs for stay assembly complete with all section such as stay plate, stay clamps, stay brackets with 20mm dia stay rod complete all as shown in electrical plate No 1 of SSR Part-I complete all as specified and directed NOTE : Loop insulator, excavation and concrete work will be measured and paid separtely.
S&F in repair moulded case circuit breaker four pole 400 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and magnetic relay complete all as specified and directed.
S&F in repair moulded case circuit breaker four pole 250 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and magnetic relay complete all as specified and directed.
S&F in repair moulded case circuit breaker four pole 200 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and magnetic relay complete all as specified and directed.
S&F in repair moulded case circuit breaker four pole 160 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay complete all as specified and directed.
S&F moulded case circuit breaker four pole 125 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay complete all as specified and directed.
S&F in repair moulded case circuit breaker four pole 100 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay complete all as specified and directed.
S&F in repair moulded case circuit breaker four pole 63 Amps, 36 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay complete all as specified and directed.
S&F in repair digital voltmeter 0 to 500 Volts 96mm x96mm flush type in LT Panels complete all as specified and directed.
S&F in repair digital ammeter range as per existing 96mm x96mm flush type in LT panels complete all as specified and directed.
S&F in repair LT current transformer ratio from 200/5 Amps or 100/5 or 400/5 in LT panels complete all as specified and directed.
S&F in repair indicator assembly (RYB) LED type in LT panel boards complete all as specified and directed.
S&F tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 40 mm bore including removing the rusted old one complete all as specified and directed.
S&F tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 50 mm bore including removing the rusted old one complete all as specified and directed.
S&F tube light grade galvanised with all fittings laid along the pole/in trenches / under road or floor of 80 mm bore including removing the rusted old one complete all as specified and directed.
Supply and Fix in repair of 1100 Volts grade heavy duty cable PVC insulated aluminium conductor as service connections served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 01 metre apart including 4 mm dia GI suspension wire one twin core cable flat or circular stranded conductor of size 10 sqmm 2 core complete all as specified and directed.
Material & labour for earth continuity conductor galvanised iron strip 32x6 mm buried in ground incl taking out old one complete all as specified and directed.
M&L in repair of Earthing complete with GI earth plate 60cmx60cm and 6mm thick electrode and 4mm dia GI wire as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and including earth work, PCC pit and RCC cover, watering pipe 20 mm dia light grade,funnel, wire mesh, protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire, charcoal dust and salt etc. and connected to earthing test point complete all as specified and directed.
S&F in Fix in repair of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 45W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and directed.
S&F in Fix in repair of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 90W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and directed.
S&F in Fix in repair of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 60W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and directed.
S&F in Fix in repair of Integral LED street light luminaires complete comprising of epoxy powder coated housing, enclosed with glass cover in front 70W mounted on MCPCB suitable for 50mm dia pipe in gress protection IP-66 complete all as specified and directed.
Supply and fixing in repair of LED based energy saving & environment friendly long life versatile luminaire made in pressure die cast housing and heat sink with aluminium extruded with IP-65 of 120 watt complete with front toughened glass cover including connection with 2.5 sqmm 3 core PVC insulated copper wire complete all as specified and directed.
Supply and fixing in repair of LED based, saving & environment friendly, long life versatile flood light Lumos IP-65 of 120 W capacity complete with front glass cover complete all as specified and directed.
Supply and fixing in repair of LED based, saving & environment friendly, long life versatile flood light Lumos IP-65 of 200 W capacity complete with front glass cover complete all as specified and directed.
Supply and fixing in repair of LED based, saving & environment friendly, long life versatile flood light Lumos IP-65 of 250 W capacity complete with front glass cover complete all as specified and directed.
S&F in replacement of LED driver suitable for 35/45W LED light fittings complete all as specified and directed.
S&F in replacement of LED driver suitable for 60/72/75W LED light fittings complete all as specified and directed.
S&F in replacement of LED driver suitable for 90W to 120 W LED light fittings complete all as specified and directed.
Supply and fixing in repair LED post top light fitting made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection 40 watts with high efficiency long life LEDs In-built replaceable electronic driver ccomplete all as specified and directed. MAKE:- Bajaj cat No. BGCL 40W LED WH / Havells /Wipro / Crompton Greaves
Supply and fixing in repair Cone NXG LED Bollard 08W light fitting with uniformly lit diffuser at the upper portion acts a beacon of path guidance in a landscape environment with robust IP 65 rating complete all as specified and directed. Make Havells CAT Part No CONENXGBLS8WLEDPSYM830 TOPC/Wipro / Crompton Greaves/BAJAJ Note:-The quoted rate shall deemed to include the cost of PCC of 30cmx30cm x100cm 1:2:4 type B2 using 20 mm graded stone aggregate and giving the complete connection to light fittings.
Taking down of high mast light, hot dip galvanised mast 15/16 M high and luminairies carriage duly opening of nut & bolt at bottom with the help of Hydra/Crane for repair/replacement of old UNSV winch and steel wire ropes (as per existing) complete with ratchet, limit switches etc as per standard engineering practice to avoid falling of carrirer during raising of lowering and re-installation, testing at site and comissioning after satisfactorily repair complete all as specified and directed.
Material & labour in replacement of GI pipe bracket made out of galvanised iron tubing 32/40mm bore (dia), light grade, 1.20 M long bent to shape as per specified for fixing street light fitting including suitable size of clamps and applying two coats of aluminium paint over a coat of aluminium primer complete all as specified and directed.
Material & lalbour in replacement of cable junction box/ distribution board IP 65 with metric knockouts for cable entry of size 10 to 25 Sqmm x 2 core including fastening clamp with LT pole, box size : 333 x 233 x 120 mm (or nearest higher size) hinged cover with locking arrangements including with terminals TPN strip, with 01 No. MCB SP 6A complete all as specified and directed.
Material & labour in repair for sub main wiring using FR insulated unsheathed, multistrand copper conductor FR-LS PVC cable 2 runs of size 2.5 Sqmm for phase and neutral and 1.5 Sqmm for earthing, drawn through rigid PVC conduit 20 mm dia with clamps for fixed on pole for connection from junction box to light fitting/switch complete all as specified and directed. NOTE:- Two runs of cable for phase / neutral and one run of cable for earth including conduits shall be measured and paid as one unit length.
Material & labour for LT heat shrinkable cable jointing kit suitable for 3.5 core 35 to 50 Sqmm aluminium cable complete all as specified and directed.
Material & labour for LT heat shrinkable cable jointing kit suitable for 3.5 core 70 to 150 Sqmm aluminium cable complete all as specified and directed.
BLANK
S&F in Fix in repair PVC Line spacer of superior quality of 4 Way spiral type all as specified and as directed.
S&F in Fix in repair PVC Line spacer of superior quality of 6 Way spiral type all as specified and as directed.
Supply and fixing of ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 630 Amps as per existing at site incl taking out the old unserviceable complete all as specified and as directed.
Dismantling of complete high mast light with foundation for shifting to new location (within 300 metres) from old location, hot dip galvanised mast 15/16 M high and luminairies carriage duly opening of nut & job bolt at bottom with the help of Hydra/Crane for repair/replacement of old UNSV winch and steel wire ropes (as per existing) complete with ratchet, limit switches etc as per standard engineering practice to avoid falling of carrier during raising of lowering and re-installation for relocating to another location within 300 mtr distance of present location, testing at site and comissioning after satisfactorily repair complete all as specified and directed. Notes :- (a) Cost of Foundation casting as per Design recommended by manufacturer & erection of High Mast shall deemed to be included in the quoted rates. (b) Cost of excavation, hydra/crane for transportation shall deemed to be included in the quoted rates. (c) Supply of foundation bolts, anchor plate & template & control plate, base plate and nuts bolts etc shall deemed to be included in the quoted rates. (d) Foundation, Erection, Earthing, testing & commissioning of 15/16 Mtr High Mast lighting [system & cabling work complete as per OEM specifications and all as specified and as directed.
M&L painting of steel tubular pole 9.0 mtr long, by applying one coat of alluminium paint after scraping / brushing and cleaning the rust on pole and cross arms . Alluminium painting will be done on pole above 1.5 Mtr hight from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enammelled paint ( 30 cms each) Pole Nos will be written on pole by black paint in yellow circle of 150mm dia complete all as specified and directed.
YATTOO ENTERPRISES
M/S Manzoor and Co
Adil Mohammad Dijoo
M/S GHULAM HASSAN KUCHAY
FIRDOUS AHMAD BABA
FG CONSTRUCTION
M/S Noor Mohammad Shalla
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .