| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹38.3 L+₹1.4 L (3.72%)Rejected-Finance | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹39.7 L+₹2.8 L (7.61%)Rejected-Finance H NO 767 NEAR OLD POST OFFICE NEW VADDEM VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹40.5 L+₹3.6 L (9.81%)Rejected-Finance | L4 | Rejected-Finance Higher bidder | |
| 5 | L5₹41.3 L+₹4.4 L (12.0%)Rejected-Finance | L5 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
8 Jun 2021, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
ADDITION ALTERATION AND SPECIAL REPAIRS TO 17 IN LIVING OFFICERS CABIN MB BLOCK P 95 1 WARDROOM AT INS HANSA UNDER GE NW VASCO
2021_MES_438875_1
85421/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE NW VASCO
₹74,000
Yes
17 Jul 2021
27 Apr 2021
10 Jun 2021
27 Apr 2021
8 Jun 2021
1 Jun 2021
Amount
Schedule 'A' -Part I (B/R Works)
M&L for gunniting exposed concrete surfaces with one layer of compast spray set modified concrete 20mm average thickness in proportion (50Kg cement 3 to 6mm granite chips 100 kg, zonal sand 50 kg and complast 3 to 2.5% by weight of cement & 12.5 to 16.5 ltr of water mixed with admixture including bonding agent after applying rust remover of approved make or equivalent approved chemical to old rusted reinforcement after necessary preparation of surfaces by brush application and gunniting with pressure nozzle with a delivery capacity of 2.5 Kg/sqm and removing the debris not exceeding 250 m and depositing complete all as specified and directed by Engineer-in-charge to following locations:-
(a) 40 mm thick in columns
(b) 30 mm thick in beams
(c) 20 mm thick in slabs
S&F hard drawn steel wire fabric cut to length bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm dia not exceeding 4 Kg/sqm complete all as specified and as directed
M&L for bonding the entire exposed surface with one coat of SBR of approved make as per manufacturer instructions over wire fabric and surfaces of concrete structure complete all as specified and as directed
Dismantling/Taking out existing hessain base felt of any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and leveled complete all as specified and as directed
M&L for providing 10mm thick plaster in cement mortar 1:4 mixed with 3% integral water proofing compound over roof top surface finished to even & smooth w/o using extra cement complete all as specified and as directed Note :- Integral water proofing compound will be measured and paid separately
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the mother slab. Filling the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Brush apply the 1st Priming coat of approved make on prepared concrete/plastered surface by diluting 2 parts of Prime seal with 1 (one) part of water and allow to dry for 04 (four) hours. Apply the first coat of waterproofing coating of approved make without any dilution at the rate of 2 Sqm per liter over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completely. Immediately apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats will be 6 to 8 hours all as directed and as per manufacturers instructions.
Taking down cement plaster on brick or stone walls, ceilings etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed
M&L for rendering 15 mm thick on block masonry surfaces or other than fair faces of brick work in cement mortar 1:4. finished to even and smooth without using extra cement complete all as specified and as directed
M&L for rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in cement mortar 1:4 & 2nd coat of 5mm in cement mortar 1:4 mixed with 3% integral water proofing compound finished to even & smooth w/o using extra cement complete all as specified and as directed Note :- Integral water proofing liquid will be measured and paid separately.
M&L for rendering 5 mm thick cement plaster on ceiling in cement mortar 1:3 mixed with 3% integral water proofing compound finished to even & smooth without using extra cement separately complete all as specified and as directed Note :- Integral water proofing liquid will be measured and paid separately.
Supply only water proofing compound complete all as specified and as directed
M&L for preparing new plastered ceiling surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling complete all as specified and as directed
M&L for preparing new plastered wall surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall complete all as specified and as directed
M&L for complete removal of existing treatment and Preparing old plastered ceiling surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling complete all as specified and as directed
M&L for complete removal of existing treatment and Preparing old plastered wall surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall complete all as specified and as directed
M&L for preparation of new plastered surface and applying two coats of weather proof high glove antifungal paint on external surface with suitable primer complete all as specified and as directed
M&L for complete removal of existing treatment and preparing old plastered wall surfaces and applying two coats of weather proof high glove antifungal paint on external surface with suitable primer complete all as specified and as directed
Dismantling floor/wall tiling including cement mortar bedding but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and as directed
M&L for granite 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed
M&L for screed bed or bedding layer of mortar 15 mm thick cement plaster 1:4 for laying floor finished to receive floor tiles complete all as specified and as directed
M&L for vitrified Ceramic tiles of light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors/skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed
M&L for vitrified Ceramic tiles of Dark shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors/skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed
M&L for rendering 10mm thick in 1:6 cement mortar on fair faces of block work or concrete surfaces to receive glazed tiles complete all as specified and as directed
M&L for non - skid coloured Ceramic tiles 7 to 8 mm thick, joint free (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed
M&L for glazed coloured ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed
Taking down chowkhat or frames not exceeding 1.5 sqm each (w/o taking of shutters from the frame and removing to store) complete all as specified and as directed
Taking down chowkat or frames exceeding 1.5 sqm but not exceeding 4 sqm each (w/o taking of shutters from the frame and removing to store)
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam colour PVC sheet on back face, including 20 mm thick PVC lining around all 4 edges of shutter, supplying & fixing in frame at site as per specification & drawing all as specified and as directed.
All as per Item No.29 here in before but wire gauzed i.e. panel will be of wire gauze in lieu of single side prelam PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly complete all as specified and as directed
S&F Factory made 100% solid wood plastic(WPC) Decorative Door Frame, single rebate of size 75mm x 50mm made from wood plastic composite(single extruded process) material with density 780 Kg/Cum complete all as specified and as directed.
S&F Factory made 100% solid wood plastic(WPC) Decorative Door Frame, double rebate of size 125mm x 65mm made from wood plastic composite(single extruded process) material with density 780 Kg/Cum complete all as specified and as directed.
S&F Butt hinges medium weight stainless steel 100mm size complete all as specified and as directed
S&F Extruded stainless steel handles 100 mm grip size complete all as specified and as directed
S&F Stainless steel, barrel tower bolts of extruded section and fixed 150mm size complete all as specified and as directed
S&F Stainless steel, anodised, sliding door bolt 250mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed
S&F Powder coated aluminium window/ventilators shutter including frame, any type sliding or openable with frame, & other similar work etc. fabricated by using the approved standard section including necessary arrangements to receive 4mm thick glass or wire mesh with aluminium channel beading & stainless steel screws including the cost of rubber gasket/rubber beading etc. complete including necessary handles, roller wheels, hinges etc complete all as specified and as directed. Note :- Weight of aluminium section shall be measured exclusive of all fittings fixtures, hinges, handle, bolts, rubber gasket/rubber beading and locking arrangements.
S&F Powder coated aluminium grill of design DG-104 pattern, made out of 10mm dia rod fixed with and including stranded aluminium frame of 'F' section of size 23.4x15.3x1.4 mm thick all as per manufacturer's instructions complete all as specified and as directed
S&F 4mm thick sheet glass ordinary quality exceeding 0.5 sqm each pane complete all as specified and as directed
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia complete all as specified and as directed
All as per Item No.40 here in before but of 25 mm dia complete all as specified and as directed
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of dia 20 mm complete all as specified and as directed
All as per Item No.42 but of 25 mm dia complete all as specified and as directed
S&F in repairs 32 mm dia Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and as directed
S&F in repair PVC Connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed
S & F in repairs 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified and as directed
S&F in repair stop valves fancy type, chromium plated 15 mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed
S&F Wash basins 550x400mm vitreous china (flat back type) any size including cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fittings complete all as specified and as directed
S&F in repairs chromium plated fancy type Bib taps 15 mm dia, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed
S&F Pillar taps fancy type of 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed
S&F Chromium plated shower roses 125 mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and as directed
M&L for Stainless steel floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) 75 mm dia complete all as specified and as directed
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white including seat cover (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and as directed
S&F PVC valveless, syphonic action type, flushing cistern, low level, coloured, with inlet , ball valve, float and handle including brackets outlet flushing pipe of capacity 10 ltrs complete all as specified and as directed
S&F Hand shower (Health faucet) dia 8mm 1 mtr long flexible tube and wall hook complete all as specified and as directed
S&F in repairs aluminium anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed
S&F in repairs Soap dish, of material brass with glossy finish complete all as specified and as directed
Dismantling boarding, any description, fixed in any position with Screws complete all as specified and as directed
S&F 18 mm thick single side prelaminated woodgrain solid PVC sheet suitablely fixed in shelves; Partitions and shelves of built-in cupboards, almirahs, book cases, toilet boxes, racks, pelmets and similar work with all fittings and locking arrangements as per direction and specifications complete all as specified and as directed
S&F Stainless steel railing of height 0.9m and grade SST-316 including all accessories with horizontal support of stainless steel and fitting to staircase, varandah, balconies etc all as per manufacturers instruction complete all as specified and as directed
Demolition of Cement Concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed
M & L for 75 mm thick cement concrete type C2, 1:3:6 using 40 mm graded stone aggregate in sub base of internal flooring/plinth protections, etc complete all as specified and as directed
Schedule 'A' -Part II (E/M Works)
Taking down carefully any type of copper/aluminium point wiring (light, fan, socket or power complete including conduits/casing capping with fittings such as switches. ceiling roses, pendents regulators ,bells.. sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS 694 of size 1.5 Sq mm single core, including one No 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit medium grade of as required size (not less than 20 mm dia) ISI marked medium grade with all accessories of same grade fixed concealed in wall including provision of modular metal flush box modular cover plate with frame top cover for housing switch, socket, fan regulators etc for one light point controlled by one 5 Amp switch one way complete all as specified and as directed
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing capping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed
M & L for sub main wiring with two runs of single core 2.5 Sqmm FR-LSH Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing & capping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc. as required fixed on wall along with one run of 2.5 Sqmm single core PVC FR-LSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as specified and as directed Note: Three runs of 2.5 sqmm cable and one run of PVC casing and capping shall be considered as one unit length
M & L for sub main wiring with two runs of single core 4 Sqmm FR-LSH Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing & capping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc. as required fixed on wall along with one run of 4 Sqmm single core PVC FR-LSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as specified and as directed Note: Three runs of 4 sqmm cable and one run of PVC casing and capping shall be considered as one unit length
M & L for sub main wining with two runs of single core 6 Sqmm FR-LSH Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing & capping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc. as required fixed on wall along with one run of 6 Sqmm single core PVC FR-LSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as specified and as directed Note: Three runs of 6 sqmm cable and one run of PVC casing and capping shall be considered as one unit length
M & L for sub main wiring with four runs of single core 6 Sqmm FR-LSH Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing & capping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc. as required fixed on wall along with two runs of 6 Sqmm single core PVC FR-LSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as specified and as directed Note: Six runs of 6 sqmm cable and one run of PVC casing and capping shall be considered as one unit length
M & L for sub main wiring with four runs of single core 10 Sqmm FR-LSH Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing & capping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc. as required fixed on wall along with two runs of 10 Sqmm single core PVC FR-LSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as specified and as directed Note: Six runs of 10 sqmm cable and one run of PVC casing and capping shall be considered as one unit length
S & F in repairs modular bell push, flush type. 6 Amps complete all as specified and as directed
S & F in repairs modular switch single pole one way 16 A, 240 V complete all as specified and as directed
S & F in repairs modular switch single pole one way 6 A. 240 V complete all as specified and as directed
S & F in repairs modular socket outlet 2 in 1, 6 Amp 240 volts, complete all as specified and as directed
S & F in repairs modular socket outlet 6A/16A, 5 in 1, 3 pin flush type universal, 240 volts complete all as specified and as directed
S&F in repairs white cover plate with frame 2 module complete all as specified and as directed
S&F White Cover plate with frame 3 module complete all as specified and as directed
S&F White Cover plate with frame 6 module complete all as specified and as directed
S&F White Cover plate with frame 8 module complete all as specified and as directed
S&F Metal flush box 2 module complete all as specified and as directed
S&F Metal flush box 3 module complete all as specified and as directed
S&F Metal flush box 6/8 module complete all as specified and as directed
S & F in repairs ceiling rose, 3 phase/ PVC / polycarbonate, isolated body complete all as specified and as directed.
S&F in repairs fan step regulator, 120W-2 module complete all as specified and as directed.
S&F in repairs call bell AC, 230 Volts single pole, ding-dong sound type complete all as specified and as directed.
Taking down unserviceable any type of Main Switch, DB's including MCB including wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
S&F 20/25 Amps motor starter switch with overload protection ideal & safe for air conditioners cooler, water pumps, refrigerators mixer and all type of appliances computers complete all as specified and as directed.
S & F 20/25 Amp Power unit combo MCB Protected socket with top ideal & safe for air conditioners ,cooler ,water pumps, refrigerators mixer, and all type of appliances Computers complete all as specified and as directed.
S&F in repairs MCCB DB VTPN, 12 way. (MCCB 36 way O/G) double door, vertical type including provision of one MCCB of 200 amps breaking capacity 25 KA, 4 pole without MCB complete all as specified and as directed
S&F in repairs MCCB of 100 to 125 A breaking capacity 25 KA. 4 pole thermal magnetic release compact type suitable for MCCB DB Vertical type as incoming in the VTPN DB's complete all as specified and as directed
S&F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed
Dismantling of water heater of any capacity from its position and keeping a side in safe custody for servicing and unserviceable water heater shall be deposited in MES store yard complete all as specified and as directed
Fixing of serviceable water heater of any capacity from its position and serviceable water heater shall be installed its original position complete all as specified and as directed
M & L for earthing complete with galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts. check nuts and washers of brass as shown in electrical plate No. 3 of SSR part 1 including necessary excavation and earth work, Gl Pipe 20 mm bore light grade for watering with funnel, wire mesh, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick precast RCC cover slab 1:2:4 type B 0 with 8 mm dia TMT bar and handle with lifting hooks, adequate quantity of charcoal dust and common salt etc including testing and taking out old unserviceable any type complete all as specified and as directed. Note: GI earth wire upto 7.5 RM is included in the unit rate quoted
Taking down carefully ceiling fans of size 1200/1400 mm sweep at any height of any sweep/make/model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs including servicing, overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins, cater pins, coupling boll, capacitor holder, terminal adaptor, screws, nuts, spring washers for blade/body etc and replacement of accessories such as ball bearings, gun metal bushes, capacitor, canopy top & bottom, shackle clip assembly and assembling of all parts and painting with two coat of synthetic enamel paint by using electric spray machine similar to match with existing colour including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance after renovation of bldg complete all as specified and as directed Note : After taking down fan will be in contractor custody to keep in safe condition
All as per Item No .97 here in before but for Exhaust fan 300/380mm sweep complete all as specified and as directed
M&L for rewinding of exhaust fan motor of 300/380 mm with new supper enameled copper winding wire of existing gauge applying insulated assembling including removing. burnout copper winding wire complete all as specified and as directed.
M&L for rewinding of ceiling fan motor of 1200/1400 mm sweep with new supper copper winding wire of existing gauge and number of turns and applying insulated varnish and assembling including removing burnt out copper winding wire complete all as specified and as directed
S & F in airs energy efficient surface Mounted LED luminaire 20 watts 4' long, with acrylic cover complete accessories including necessary two core copper wire for connection from ceiling rose to connector of enameled approximate length 0.5 m complete all as specified and as directed
S & F in repairs round recess Surface mounting lights LED flat panel 18 Watt, white powder coated CRCA housing with high power LEDs, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V.complete with all accessories such as electronic driver, LED strip, connector block etc and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and as directed
S & F in repairs energy efficient surface Mounted directed. LED luminaire 10 watts 2' long, with acrylic cover complete with all accessories including necessary two core copper wire for connection from ceiling rose to connector of approximate length 0.5 m complete all as specified and as directed
S & F in repairs energy efficient Mirror light surface Mounted luminaire 12 watts with in-built motion sensor with preprogrammed option of dimming switching and changeover to suit customers requirement with acrylic cover complete with all accessories including necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 m complete all as specified and as directed
S&F in replacement of 120 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminaire efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminaire should be 6000 Lumens) including street light bracket made out of GI tubing 40 mm dia for fixing on wall/pole. The luminaire should have 5 KV surge protection. PF > 0.95, and total harmonic distortion of THD 10% voltage range of 140-280V should be provided. The manufactures LOGO must be embossed/Engraved in the housing of the Luminaire complete all as specified and as directed
M & L for street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape suitable for below mentioned security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc complete all as specified and as directed
M/s VEEJEE ENTERPRISES
M/S DUBAL CONSTRUCTION
CVs CONSTRUCTIONS
M/S G.N.POWAR
M/S jvsr constructions
pk janardhanan
SHIVRAJ CONSTRUCTIONS
M/S Kartik Enterprises
SACHIN CONSTRUCTIONS
M/s RAJ CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .