Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical 4 4 VIKAS NAGAR LUCKNOW U P | LUCKNOW | LUCKNOW | UTTAR PRADESH | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 5 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹10 L
EMD Value
₹1 L
Closing Date
22 Sept 2026, 12:00 pmClosed
EE PD PWD Bulandshahar
EE PD PWD Bulandshahar
Road safety workof Meerut-Badaun Road SH-18 between chainage 69.244 and 71.456 in District Bulandshahr
2026_CEMRT_1184021_11
5730/1A Dt. 29.08.2026
Open Tender
Civil Works - Others
Percentage
90 days
Bulandshahar
Please refer Tender documents.
3 documents required · 3 mandatory
₹856
₹1 L
Yes
EE PD PWD Bulandshahar
22 Sept 2026
15 Sept 2026
22 Sept 2026
15 Sept 2026
22 Sept 2026
15 Sept 2026
15 Sept 2026 - 16 Sept 2026
16 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Road marking with hot applied thermoplastic compound with reflectorsing Glass beads on bituminous surface.
Provoding and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads@250 gms per sqm area thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-2015 The finished surface to be level, uniform and free from streaks and holes. | 1,100 | Sqm | 610 | ₹6,71,000 |
| 2 | Road marking with hot applied thermoplastic compound with reflectorsing Glass beads on bituminous surface.
Provoding and laying of hot applied thermoplastic compound 5 mm thick including reflectorising glass beads@250 gms per sqm area thickness of 5 mm is exclusive of surface applied glass beads as per IRC:35-2015 The finished surface to be level, uniform and free from streaks and holes. | 60 | Sqm | 800 | ₹48,000 |
| 3 | Refliective Raised Pavement Markers (Cat Eye/Road Stud)
Supply and fixing of raised pavement marker with Made of Plastic body of RPM/Road Stud shall be moolded from ASA (Acrylic Styrne Acrylonitrite) or HIPS (High Impact Polystyrene) or Acrylonitrite Butadien Styrene (ABS) or Any other suitable material approved by the Engineer. The marker shall support a load of 13.635 kg tested in accordance with ASTM D4280. The Reflective panels shall consist of number of lenses contatning single or dual prismatic cubes capable of providing total internal reflection of the light entring the lens face, lenses shall be mouled of meithyl methecrylate confirming to ASTM D788 of equivalent. The slop or retro-reflecting surface shall preferably be 35+/-5 degree to base and the area of each retro-reflecting surface shall not be less than 13.00 sq.cm the marker height shall not be less than 10 mm and shall not exceed 20 mm & Width shall not exceed 130 mm. The base of the marker shall be flat within 1.3 mm all road studs shall be legibly marked with the name, trade or other means of identification of the manufacture epoxy installations, excess adhesive around the edge of the marker excess adhesive on the pavement and adhesive on the exposed surface of the marker shall be immediately removed. The Contractor shall submit a two year warranty for satisfactory field performance including stipulated retro-reflecting panel, to the Engineer in addtion a two year warranty for satisfactory infield performance of the finished road marker shall also be given by the contractor who carries out the work of fixing of reflective road markers, in case the markers are displaced, damaged, get wom out or lose their reflectivity compared to stipulated standard the contractor would be required to replace all such markers within 15 days of the intimation from the Engineer, at his own cost. The rate shall include all material, labour, T&P, transportation, installation and incidentals all complete as per direction of the Engineer-in-charge.
RPM (With shank) | 700 | Nos. | 320 | ₹2,24,000 |
| 4 | Retro-reflectorisedc Traffic sign as per IRC-67-2012
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC 67-2012 made of high intensity sheeting type-IV vide clause 801.3. fixed over aluminium sheeting 1.5mm thick supported on a mild steel angle Iron post 75mm x 6mm firmly fixed to the ground by means of properly designed foundation with 15 grade cement concrete 45cm x45cm x 60cm, 60cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro-reflection, daytime colour and luminance, shrinkage, flexibillity, liner removed, adhesion, imopct resistance, specular glass and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition. It abroad Alermatively a certificate conforming to ASTM specification (D-4956-09) on artificial accelerated weathering requirments from a reputed laboratory in india can be accepted provislonally. In such a situation, the Employer/ client, if so desires could seek for a performance guarantee which be released afler receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67-2012. Legends, Letters, numerals and borders etc should be as per MoRTH specification No-801.3.7. Proof of the same in form of government report shall be uploaded while quoling tender.
iii) 60 cm Circular with diffinitation plate (20cm x 60cm) | 5 | Nos. | 3,800 | ₹19,000 |
| 5 | Retro-reflectorisedc Traffic sign as per IRC-67-2012
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC 67-2012 made of high intensity sheeting type-IV vide clause 801.3. fixed over aluminium sheeting 1.5mm thick supported on a mild steel angle Iron post 75mm x 6mm firmly fixed to the ground by means of properly designed foundation with 15 grade cement concrete 45cm x45cm x 60cm, 60cm below ground level as per approved drawing. The Retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro-reflection, daytime colour and luminance, shrinkage, flexibillity, liner removed, adhesion, imopct resistance, specular glass and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory/ Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition. It abroad Alermatively a certificate conforming to ASTM specification (D-4956-09) on artificial accelerated weathering requirments from a reputed laboratory in india can be accepted provislonally. In such a situation, the Employer/ client, if so desires could seek for a performance guarantee which be released afler receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67-2012. Legends, Letters, numerals and borders etc should be as per MoRTH specification No-801.3.7. Proof of the same in form of government report shall be uploaded while quoling tender.
x) 30x90 cm (Left/Right) Object Hazard | 5 | Nos. | 3,300 | ₹16,500 |
| 6 | Supply & Fixing of M S Delineator made of Mild steel with pure polyester powder coating with the minimum thickness of powder coating of not less than 40 micron for protection against corrosion. The surface should be conceated so that there should not be any exposed surface without powder coating. Alternatively, these metal guide poles can beconcealed with thermoplastic body. The posts shall have Ian ellipsoidal or circular design with the height of the pole shall be 800 to 900 mmabove the ground with about 200 to 300 mm base which can be anchored onto the ground. Mild steeI Guide Poles shall conform to Type XI sheeting specifications as per IRC:67 and ASTM D4956 which would ensure to obtainI clear visibility of the road alignment during night time. The Retro reflective sheeting shall be tested for A certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, liner removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Government Laboratory / Institute by the manufacturer of the sheeting and in case the certificate is obtainedfrom international condition, it should also be obtained from Indian condition within 3 years of launching of product by the manufacture in abroad. Alternatively, a certificate conforming to ASTM Specification (D4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally. In such a situation, the Employer / Client, if so desires, could seek for a performance guarantee which would be released after receipt of certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 & Proof of the same Report shall be uploaded which quoting tender. The rate shall include all materials, labour, T&P, transportation, installation and incidentals all complete as per direction of the Engineer-in-Charge. | 20 | Nos. | 820 | ₹16,400 |
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
BOQ_2227799.xls
BOQ • 0.92 MB
T1.pdf
Tender Documents • 1.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .