| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr Quoted ₹1.3 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.3 Cr+₹5.8 L (4.56%)Rejected-Finance C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹1.3 Cr+₹5.8 L (4.56%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹1.4 Cr+₹11.4 L (8.97%)Rejected-Finance | ₹1.4 Cr+₹11.4 L (8.97%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹1.4 Cr+₹14.4 L (11.4%)Rejected-Finance | ₹1.4 Cr+₹14.4 L (11.4%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹1.4 Cr+₹15.7 L (12.4%)Rejected-Finance VILL PO JAGANOO DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹1.4 Cr+₹15.7 L (12.4%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
11 Jul 2023, 6:00 pmClosed
Col Sachin Sharma CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPECIAL REPAIRS TO BLDG NO P-20, P-53, P-54, P-55, P-56, P-57 AND P-58 (OR MD ACCN) AT ALBERT EKKA ENCLAVE UNDER GE (SOUTH) UDHAMPUR
2023_MES_601566_1
CWE/U(S)-25/2023-24
Open Tender
Civil Works
Item Rate
270 days
UDHAMPUR
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE (SOUTH) UDHAMPUR
₹2.2 L
Yes
20 Sept 2023
6 Jun 2023
18 Jul 2023
6 Jun 2023
11 Jul 2023
27 Jun 2023
Amount
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, including separation of serviceable materials from the unserviceable; stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by Engr-in-Charge.
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for including and disposal of unserviceable material, debris and rubbish to a distance n exc 100m as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Glazed coloured ceramic tiles 350x250mm or 450 x 350 mm and 6 to 7mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match, including 10mm thick backing layer of cement mortar in 1:3 to receive tiles in vertical surfaces, complete all as specified and as directed by Engr-in-Charge.
Non skid, light coloured, white printed ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement to match, including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes , complete all as specified and as directed by Engr-in-Charge.
Non skid, light coloured, white printed ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement to match, including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes , complete all as specified and as directed by Engr-in-Charge.
Non skid, light coloured, white printed ceramic tiles 7 to 8 mm thick (square/rectangular) as in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match, including 10mm thick backing layer of cement mortar in 1:3 to receive tiles in vertical surfaces, complete all as specified and as directed by Engr-in-Charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Machine cut kota stone slab flooring 18-20mm thick over and incl screed bed or bedding layer 15mm thick in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab in floor including rubbing and polishing mirror finish complete, all as specified and as directed by Engr-in-Charge.
Machine cut kota stone 18-20mm thick as in riser of steps, skirting, dado and pillar laid over cement screed base and jointed with white cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over and including 10 mm thick rendering in cement mortar 1:3 as in backing coat for laying wall tiles, complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
Marble work (Makrana White) 14-16 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble, complete all as specified and as directed by Engineer-in-Charge.
Moulding of kota stone/marble stone full round, complete all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compound to be measured and paid for separately as supply only.
10mm thick rendering on brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Supply only liquid water proofing compound, complete all as specified & directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Description all as per item No 18 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges 100mm, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed by Engr-in-Charge.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges 100mm, lock strike plate etc. complete, of frame size 105 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed by Engr-in-Charge.
35 mm thick, factory made, 2nd class hard wood (Sal/Hollock), plain framed, panelled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engr in Charge.
35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete, all as specified and directed by Engr in Charge.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete without glazing bars dovetailed or welded including one shop coat of red oxide primer complete all specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Factory made mild steel ventilators (box type) with top hung shutters and bottom fixed type shutters including pintol hinges, steel peg stay and one shop coat of red oxide primer complete all specified.
Factory made mild steel ventilators (box type) with upper top hung shutters and bottom fixed type shutters including pintol hinges, steel peg stay and one shop coat of red oxide primer complete all specified. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3. ii) MS fillets, glazing, wire gauge shall be measured and paid for separately
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or gorged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones omplete all as specified..
3mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane, complete all as specified.
3mm thick figured glass (frosted) ,pin head type and glazing with oil putty not exc 0.50 Sqm in each pane fixing to window/ventilator complete all as specified and as directed.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
Rolled mild steel work of angle iron as in frames of doors & Cup Board etc conforming to grade Fe 290 (E-165) complete all as specified.
2nd class hard wood (Sal/Hollock) plain, solid, straight chowkats/frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, with one or more rebates, complete all specified.
18/19mm thick Prelaminated particle board, termit proof, chemically well pressed, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work, as in kitchen cabinet, cub boards, etc including 6mm thick teak wood beading all around complete all as specified and as directed by Engr-in-Charge.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified.
Stone walling of random rubble with best quality locally available harder stone such as granite, trap or basalt, uncoursed, well bonded, bedded, solidly hearted and built in cement mortar 1:6, complete all as specified & directed. Note: Volume occupied PCC bond stones shall be deducted from stone masonary.
All as per Srl item No. 37 above but except stone.
Plain cement concrete 1:3:6 (nominal mix), type C-1 using 20mm graded crushed stone aggregate as in precast bond stones, set in cement mortar 1:6, complete all as specified & directed.
Extra over stone walling of granite, trap or basalt stone for hammer dressing to face stones and dressing of face beds and joints, as specified, of random rubble walling, uncoursed or brought upto courses with maximum depression on face from straight edge held against the dressed surface n exc 20mm, complete all as specified & directed.
Flush pointing to random or polygonal rubble, uncoursed or brought upto courses in cement mortar 1:4, complete all as specified.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified.
All as per Srl item No. 42 here-in-before but except bricks.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1 :4 in half brick wall, complete all as specified
Plain cement concrete 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 20mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately) and applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric APP (Atactic Polypropylene) Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm complete all as specified and as directed by Engr-in-Charge. Note :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise.
50mm thick plain cement concrete 1:3:6, nominal mix, type C1, using 20mm graded crushed stone aggregate as in plinth protection, surface finished even and fair, complete all as specified.
250 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed by Engr-in-Charge.
Continuous (piano) hinges width of flaps 30 mm when opened, mild steel, bright finish or electrogalvanised complete all as specified and as directed.
150 mm long, Mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed by Engr-in- Charge.
Hasp and staple, 150 mm size safety type aluminium anodised with mild steel hinges pin, including bolt to hinge plate and fixed with screws, all as specified .
150mm long, aluminium anodised, barrel tower bolts (ISI Marked) of extruded section and fixed, complete all as specified and directed by Engr-in- Charge.
150mm size extruded aluminium alloy handles (ISI Marked), fabricated type., anodised, complete all as specified and directed by Engr-in- Charge.
Second class hard wood small fittings such as shaped door & window stops, cleat including all necessary labour, articles not exceeding 200 cubic centimetre each complete all as specified and as directed by Engr-in-Charge.
Mild steel cold rolled butt hinges (ISI Marked) 'Medium weight' 100 mm size, fixed to steel/angle iron frame by welding , if required complete all as specified and directed by Engr-in- Charge.
Mild steel cold rolled butt hinges (ISI Marked) 'Medium weight' 75 mm size, fixed to steel/angle iron frame by welding , if required complete all as specified and directed by Engr-in- Charge.
Mild steel cold rolled butt hinges (ISI Marked) 'Medium weight' 50mm size, fixed to steel/angle iron frame by welding , if required complete all as specified and directed by Engr-in- Charge.
300 mm long mild steel ordinary rat tail rod pattern door spring including roller and roller plate, fixed to frame, complete all as specified and as directed.
200mm long, mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, complete all as specified and directed by Engr-in- Charge.
Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and directed by Engr-in- Charge.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm prelam colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck in side with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Vitreous China wash basin, pedestal type,white, flat back ,size 550x400mm excluding tap, chain, plug but including brackets, waste fitting 32mm dia ,brass chromimium plated for glazed ware sink, basin with pedestal, long screwed shanks and fly nuts flange end bedded in red lead cement and other end, fixed in repairs, complete all as specified.
Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, fixing in repair, complete all as specified and as direceted by Engr-in-Charge.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of steel and iron surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide/ zink chrome primer complete all as specified.
Preparation of new plastered surfaces of ceiling and applying two coats of white wash, complete all as specified and as directed by Engr-in-Charge.
Applying two coats of oil bound distemper over and including a coat of primer and 3 mm thick a layer of wall care putty including preparation of plastered/ unplastered surfaces of wall, complete all as specified & directed by Engr-in-Charge.
Preparation of old painted surfaces and applying one coat of acrylic weather proof exterior emulsion paint on walls, cornices over and including a coat of primer and 3 mm thick a layer of wall care putty including preparation of plastered/ unplastered surfaces of wall, complete all as specified & directed by Engr-in-Charge.
Water closet (Orissa pattern) including lime concrete bedding, vitreous china long pan orissa pattern 580x440mm, white with integral foot rests (excluding flushing cistern & flush pipe) fixed in repairs complete all as specified.
100mm Cast iron `P' traps , complete all as specified and as directed.(ISI Mark)
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision including 32mm dia PVC flush pipe, fixed in repairs, complete all as specified and as directed by Engr-in-Charge. MAKE: Cera Model Combiflush twin flush as per Cat Part No. 2603 or equivalent in performance of makes as specified in PS.
Stainless steel grating doom 100mm dia square or round fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Tubular towel rails brass chromium plated, 20 mm dia, D type, 60 cm long between flanges, fixed with rawl plugs fixed in repairs complete alll as specified and as directed.
PVC connections 15 mm size with PTMT nuts of length 450 mm and washers, complete all as specified and as directed by Engr-in-Charge.
Brass magic eye suitable for 180º as per the sample kept in GE's office, fix to wooden door shutter, complete all as specified and as directed.
Peg set colour coated of six as per sample kept in GE's office and fixed woth brass screws and PVC gutties, complete all as specified.
Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm, fixed in repairs, complete all as specified and directed.
Plate rack made of stainless stee, 600 x 750X0.55mm including fixing as per manufacturers instruction complete all as specified.
Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in surface channels and drains, including necessary formwork, complete all as specified and as directed by Engr-in-charge.
Plain cement concrete 1:5:10 type E-2 using 40mm graded brick aggregates as in sunken floor/ foundatiom, complete all as specified and as directed by Engr-in-Charge.
Dismantling cast iron pipe & reinforced concrete drain pipes, jointed in cement mortar of any dia taking out from trenches or fixed to wall upto 100mm complete all as specified.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 75mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 75mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 50mm bore, complete all as specified and as directed by Engr-in-Charge.
Cast iron bends with oval access door (any radius), diminishing pieces or tapers (larger bore measured) for 100mm bore pipe, all as specified and as directed by Engr-in-Charge.
Cast iron bends with oval access door (any radius), diminishing pieces or tapers (larger bore measured) for 75mm bore pipe, all as specified and as directed by Engr-in-Charge.
Stack clamps made out of 50 x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100/110 mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
Stack clamps made out of 50 x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
Cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 75 bore, fitted with oval access door as in repairs complete all as specified and as directed.
Cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 100mm bore, fitted with oval access door, fixed in repairs complete all as specified and as directed.
110mm bore, PVC (SWR) pipes, pressure rating 4 kg/sqcm, single or double socketed, in any length with rubber ring joints, fixed to wall, complete all as specified and as directed by Engr-in- Charge.
110 mm bore PVC SWR bends and fixed solvent etc complete all specified and as directed.
PVC (SWR) cowl for 75 mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
PVC (SWR) cowl for 50 mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
75mm Cast iron floor traps with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4). complete all as specified and as directed.(ISI Mark)
Cast iron lids for oval access doors for 75mm bore pipe and fittings including all necessary threading and nut/bolt as required, complete all as specified and as directed.
Cast iron lids for oval access doors for 100mm bore pipe and fittings including all necessary threading and nut/bolt as required, complete all as specified and as directed.
RCC 1:2:4 (Nominal mix) type B-1, using 20mm graded crushed stone aggregates as in chajjas and similar work including necessary formwork, complete all as specified.
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing from site, complete all as specified and as directed by Engr-in-Charge.
15 mm bore steel water tubing medium grade galvanised with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and as directed by Engr-in-Charge.
20 mm bore steel water tubing medium grade galvanised with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and as directed by Engr-in-Charge.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm, fixed in repair,complete all as specified.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 15mm, fixed in repair,complete all as specified.
Stop valves/Angle valve, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Stop valves, fancy type chromium plated with long shanl concealed type, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15mm, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank , two layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), including dismantling existing water tanks, complete all as specified and as directed by Engr-in-Charge.
Brass Chromium plated over head shower rose, 125mm size with swivel joint fixed to pipe or union of 15mm bore, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Soap dish, vitreous China white, approximate size 160x 160x90mm, fixed in repairs, complete all as specified in .
CP mixture 15 mm bore for mixing hot & cold water screwed down for iron pipe, fixed in repairs, complete all as specified.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
75mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base to floor/paving, complete all as specified and as directed by Engr-in-Charge.
Machine pressed / vibro mechenically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of cement with imported pigment, over and including 25mm thick layer of sand cushioning, complete all as specified directed by the Engr-in-Charge. Note: Shape& pattern shall be approved by the GE.
Machine pressed / vibro mechenically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of grey cement without pigment, over and including 25mm thick layer of sand cushioning, complete all as specified directed by the Engr-in-Charge. Note: Shape& pattern shall be approved by the GE.
Demolition and breaking up drain pipes, 100mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, in one brick honey comb walling, built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Excavation over areas not exc 1.5m deep and getting out in any type of soil complete all as specified.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in and getting out in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete (1:4:8) type D2 using 40mm graded stone aggregate as in foudation, filling and mass concrete all as specified.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material (soils) to a distance exceeding 250m but not exceeding 500m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:4, complete all as specified.
15 mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4 mixed with liquid water proofing compond as per manufacturer instructions, finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-Charge. Note: WPC shall be measured and and paid for seperately as supply only.
Pre-cast RCC cement concrete 1:2:4 type B-I (20mm graded) as in manhole cover slab and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed by Engr-in-Charge.
Mild steel framed work as in frames to manhile covers of anfle iron or other section including holdfast conforming to Fe 290-0 or Gde-E-165, complete all as specified and as directed.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
TMT mild steel bars, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and includingMS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
Reinforced concrete pipes 200mm bore ,class NP2, laid and jointed complete with coller all as specified and as directed.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm bore pipes all as specified.
150mm bore salt glazed stoneware drain pipes laid trenches, jointed and tested, complete all as specified and as directed.
Plain cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in conc bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipes all as specified.
Reinforced cement concrete 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge.
110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregates) as in beds of surface channel and drains, including necessary formwork, complete all as specified and as directed by Engr-in-charge.
110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, as in weep holes, complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc to match the existing, complete all as specified and as directed by Engr-in-Charge.
Taking down old unserviceable copper /aluminium,submain wiring any type/size from existing and making good disturbed surfaces of wall, ceiling, floors etc to match the existing, complete all as specified and as directed by Engr-in-Charge.
Taking down MCB DB SPN/TPN with all accessories carefully and making good disturbed surface of walls, complete all as specified and directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit (ISI marked) 20mm dia and over, medium grade and all accessories for one light / fan controlled by one switch suitable for pressed GI terminal boxes (modular type) of required modules concealed on walls including inner and outer cover plates for fixing of modular switches/socket/ regulator etc along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, fixed in repair, complete all as specified & directed by Engr-in-Charge. Note: Modular metal flush boxes & inner and cover plates deemed to be included in quoted rate.
Description all as per item No 145 above but for one light point controlled by 2-two way switches.
Description all as per item No 145 above but for 3/5 pin 6 Amp socket outlet on independent board .
Description all as per item No 145 above but for 3/5 pin 6 Amp socket outlet on the same board with other switch.
All as per description of Serial item No 145 here-in-before but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly.
Switch piano, single pole, 1 module, one way, 6 Amp (modular type), 230V, 50 Hz AC, complete all as specified and as directed by Engr-in-Charge.
Switch piano, single pole, 2 module, two way, 6 Amp (modular type), 230V, 50 Hz AC, complete all as specified and as directed by Engr-in-Charge.
Switch piano, single pole,1 module, one way ,16 Amp (modular type), 230V, 50 Hz AC, complete all as specified and as directed by Engr-in-Charge.
Bell push Modular type, 1 module, 6 Amps 230 volts complete all as specified and as directed by Engr-in-Charge.
Socket outlet, 2 module, combined 3 pin, 6 Amp flush type modular type, complete all as specified and as directed by Engr-in-Charge.
Socket outlet, 2 module, 2 in 1- 3 pin combined, 6 & 16 Amp flush type modular type, complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, ,complete all as specified and as directed by Engr-in-Charge.
Bell (ding dong type), AC electronic type, 230 volts, single pole, 50 Hz complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for DBs when MCCBs to be used double door DB VTPN 4 ways, vertical type, including 125 Amps MCCB, 16 kA, 415 volts with 400 Amps rated bus bar and neutral link including chases wall for fixing DB and making good disturbed wall surface to match with existing specifications, complete all as specified and directed by Engr-in-Charge. (Including all PCC & cementing work for installation of TPN DB to wall).
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications, complete all as specified and as directed by Engr-in-Charge.
MCB SPN, 10 to 40 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SP, 10 to 40 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SPN, 63 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note: Make of MCB and DB shall of same make for all connected items.
MCB TPN, 63 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
Sub main wiring with two runs of 10 Sqmm ( 2x10 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 10 Sqmm (1x10sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 10 Sqmm (2x10sqmm ) ,one run of 10 Sqmm (1x10 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 4 Sqmm ( 2x4 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 4 Sqmm (1x4sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 4 Sqmm (2x4sqmm ) ,one run of 4 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit.
Sheet metal enclosure single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with and including one single pole MCB of 20 Amps and breaking capacity 10KA, complete all as specified and as directed by Engr-in-Charge.
Sub main wiring with two runs of 2.5 Sqmm ( 2x2.5 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 2.5 Sqmm (1x2.5sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 2.5 Sqmm (2x2.5sqmm ) ,one run of 2.5 Sqmm (1x2.5 sqmm ) cable and one metre of conduit will be measured as one unit.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 168 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Aluminium strip 25x3.15mm as in roof conductors and down conductors fixed with saddles and screws not more than 1mtr apart, complete all as specified and as directed.
Stepped type fan regulator 120W, 230V 50 C/S, 2 module, Deluxe Modular type electronic, hum free suitable control speed of fan from 0 to 100 %, complete all as specified and as directed by Engr-in-Charge.
Taking down ceiling / exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store, incl oiling, greasing, cleaning slot, overhauling & replacement of defective nut, bolt , washers etc. and applying two coat painting with synthetic enamel to fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose and rehanging/ refixing complete all as per the directions of Engr-in-Charge.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing, fixed in repair, complete all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Supply & fixing 9/10 watt LED Bulk Head Light energy saving with IP65 with opal diffuser, pressure die cast aluminium housing & ring for sturdiness & corrosion resistant, epoxy powder coated, isolated driver, with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volt, colour temp 6500K, Low heat generating LED (Make of LED shall be CREE/Nichia/Osram) complete making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engg-in-Charge.
LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engr-in-Charge.
LED light fitting mirror type with high output diffuser 1 feet, 5 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed by Engr-in-Charge.
New generation energy saving and environmental friendly long life LED street light of 30 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +50 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Street light Bracket complete made of GI pipe 32mm bore, light grade of suitable size, 1.2m long bent to shape as per site requirement alongwith MS flat iron clamps with nuts, bolts, washers including grouting the same with wall , complete all as per the direction of Engr-in-Charge.
Supply, laying and testing of XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 25 sqmm 3.5 core including taking up/down old unserviceable cables. complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed by Engr-in-Charge. NOTE Only punned thickness shall be measured for payment purpose.
Sub class ‘B’ old size well burnt bricks, laid flat in trenches as protection to cable, complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles, complete all as specified and as directed by Engr-in-Charge.
M/S ASHOK KUMAR PACHIALA
jyoti parkash sharma
M/S SATINDER PAL & CO.
KALSOTRA CONSTRUCTION CO
d d builders
SINGH CONST CO
M/S Inderjit Sharma and Co.
R K BUILDERS
M/S VED PARKASH GUPTA
RAJINDRA ENGINEERS & CONTRACTORS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .