Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-AOC BANSHBARI MALDA | L1 | Accepted-AOC Lowest | |
| 2 | L2₹3.1 L+₹483.39 (0.16%)Rejected-Finance | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹3.1 L+₹1,461.75 (0.47%)Rejected-Finance | L3 | Rejected-Finance 3rd Lowest |
| Sl No | Description | Qty | Unit | M/S KUNDU CONSTRUCTION L1 | MAGNET ELECTRIC WORKS L2 | KARMAKAR ENGINEERING WORKS L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supplying & fixing of 15W, 230V resess mountain Round type LED Light (Make- Philips/Cromton/Havells) as per GS direction of EIC. [NS] | 15 | Nos | 1,000 ₹15,000 Lowest | 1,000 ₹15,000 Lowest | 1,005 ₹15,075 |
| 2.00 | Supply & fixing 300 mm Heavy Duty Exh. (920 RPM) Grey Exhaust fan (Make-EPC/ Usha/ Orient Heavy Duty Exh.or equivalent make as approved by E.I.C] of followinng sizes after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust as per direction of E.I.C.12"( 300mm ) Speed 900 RPM [NS] | 2 | No | 3,900 ₹7,800 Lowest | 3,900 ₹7,800 Lowest | 3,901 ₹7,802 |
| 3.00 | Repairing and Serviceing of 12"( 300mm ) Exhust Fan as per direction of E.I.C [NS] | 2 | Nos | 165 ₹330 Lowest | 167 ₹334 | 168 ₹336 |
| 4.00 | Supply and Fixing of PVC Name plate under Bankura Electrical Division Office [NS] | 19 | Nos | 370 ₹7,030 Lowest | 372 ₹7,068 | 372 ₹7,068 |
| 5.00 | Supply and Fixing Notice Board at Sub-Div-II as per direction of E.I.C [NS] | 1 | item | 1,400 ₹1,400 Lowest | 1,400 ₹1,400 Lowest | 1,402 ₹1,402 |
| 6.00 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). Fixed partitions. (Unsupported length of vertical member upto 1.5 mtr. Height of both ends of vertical member restrained but panels within 0.9 sq.m.) Top , bottom & side member. PWD Building Schedule Page No.234, Item No.J(i) | 54.01 | Mtr | 673 ₹36,348.73 Lowest | 674 ₹36,402.74 | 675 ₹36,456.75 |
| 6.01 | Intermediate member. PWD Building Schedule Page No.234, Item No.J(ii) | 53.63 | Mtr | 500 ₹26,815 Lowest | 500 ₹26,815 Lowest | 501 ₹26,868.63 |
| 6.02 | Glazing clip. PWD Building Schedule Page No.234, Item No.J(iii) | 269 | Mtr | 55 ₹14,795 Lowest | 56 ₹15,064 | 57 ₹15,333 |
| 7.00 | Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating) PWD Building Schedule Page No.250, Item No.27(a) | 27.57 | Sq.M | 2,600 ₹71,682 Lowest | 2,600 ₹71,682 Lowest | 2,602 ₹71,737.14 |
| 8.00 | Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers. Fixed glazing. PWD Building Schedule Page No.239, Item No.2 A(iv) | 25.23 | Sq.M | 1,100 ₹27,753 Lowest | 1,101 ₹27,778.23 | 1,102 ₹27,803.46 |
Tender Value
Refer Docs
EMD Value
₹6,169
Closing Date
20 Feb 2024, 12:30 pmClosed
AE/BESD-I
OFFICE OF THE ASSISTANT ENGINEER Bankura Electrical Sub-Division-I, PWDte Kenduadihi PWD campus near Bhairabsthan Bankura-722102
Electrical Installation and others reparing works at Bankura Electrical Division,PWD, in the District of Bankura.
2024_WBPWD_662860_1
WBPWDTE/AE/BESD-I/e-NIQ 13 of 2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
AE/BESD-I
Please refer Tender documents.
6 documents required · 6 mandatory
₹6,169
Yes
11 Sept 2026
7 Feb 2024
22 Feb 2024
7 Feb 2024
20 Feb 2024
7 Feb 2024
Amount
Supplying & fixing of 15W, 230V resess mountain Round type LED Light (Make- Philips/Cromton/Havells) as per GS direction of EIC. [NS]
Supply & fixing 300 mm Heavy Duty Exh. (920 RPM) Grey Exhaust fan (Make-EPC/ Usha/ Orient Heavy Duty Exh.or equivalent make as approved by E.I.C] of followinng sizes after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust as per direction of E.I.C.12"( 300mm ) Speed 900 RPM [NS]
Repairing and Serviceing of 12"( 300mm ) Exhust Fan as per direction of E.I.C [NS]
Supply and Fixing of PVC Name plate under Bankura Electrical Division Office [NS]
Supply and Fixing Notice Board at Sub-Div-II as per direction of E.I.C [NS]
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). Fixed partitions. (Unsupported length of vertical member upto 1.5 mtr. Height of both ends of vertical member restrained but panels within 0.9 sq.m.) Top , bottom & side member. PWD Building Schedule Page No.234, Item No.J(i)
Intermediate member. PWD Building Schedule Page No.234, Item No.J(ii)
Glazing clip. PWD Building Schedule Page No.234, Item No.J(iii)
Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP) 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating) PWD Building Schedule Page No.250, Item No.27(a)
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column, beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers. Fixed glazing. PWD Building Schedule Page No.239, Item No.2 A(iv)
Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In Charge. (Payment will be made on finished length of the work). Movable door shutter. Top rail. PWD Building Schedule Page No.234, Item No K(ii)
Bottom rail. PWD Building Schedule Page No.234, Item No K(ii)
Lock rail PWD Building Schedule Page No.234, Item No K(ii)
Door vertical PWD Building Schedule Page No.234, Item No K(ii)
Glazing cleap. PWD Building Schedule Page No.234, Item No K(ii)
Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium sections for the following units:- Partly glazed partly panelled or fully glazed single leaf alunminium swing door made of extruded and annodized alloy aluminium sections, fabrication including cutting to proper shape and size, drilling and aligning, fitted with heavy duty hydraulic action floor sping placed in the floor with mending damages,with top pin assembly of approve make and brand, fitted with in built locking arrangement, flush bolt, glazing clips and all other necessary fittings, fixtures, adhesives and joineries, cutting glass of approved make to requisite shape and size fitting with dry set neoprene or EPDM gasketing, cutting to requisite shape and size panel board (prelaminated particle block) fixing them with glazing clips as per drawing, specification and direction of Engineer in charge. PWD Building Schedule Page No.239, Item No 2(B)
Supplying PVC rollers for sliding windows as per direction of Engineer in charge PWD Building Schedule Page No.242, Item No 6
Supplying 100 mm 4 lever mortice lock or any approved make and brand as per direction of the Engineer- in -Charge. PWD Building Schedule Page No.243, Item No 12
Supplying 125 mm. Dia acrylic handle for aluminium door as per approved make & brand natural colour. PWD Building Schedule Page No.244, Item No 13(B)
Supplying maruti lock (100mm) PWD Building Schedule Page No.242, Item No 7
Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. 8mm thick clear glass. [NS]
Repairing of Latrine flasher as per direction of the Engineer- in -Charge. [NS]
Supply Fixing of Tap washer as per direction of the Engineer- in -Charge. [NS]
Supply and Fixing of flash pipe as per direction of the Engineer- in -Charge. [NS]
Supply and Fixing of steel Tap as per direction of the Engineer- in -Charge. [NS]
Supply and fixing of 25mm CPVC pipe as per direction of the Engineer- in -Charge. (Page 30, Item 2 A Sanitary & plumbing 2017)
Opening & cuting and refixing of 4ftX5Ft Glass as per direction of the Engineer- in -Charge. [NS]
Providing labour for cleaning Divission office all Latrine Pipe as well as Drain as per direction of the Engineer- in -Charge. [NS]
Dismentalling of Cash Box foundation and to carry from old place to new place as per direction of the Engineer- in -Charge. [NS]
Fixing of Cash Box on cement concreate foundation with marvel finish as per direction of the Engineer- in -Charge. [NS]
Serviceing reparing of 80 ltr water filter as per direction of the Engineer- in -Charge. [NS]
MAGNET ELECTRIC WORKS
KARMAKAR ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .