Supply Installation Testing Commissioning Of Fully Automatic Cleaning Grading Unit 1.5 TPH
2026_DOAWB_1327946_2
solpr/rajmat/goods/clean/2026
Open Tender
Farm Machinery and Equipments
Item Rate
60 days
Lendave Chinchale Mangalvedha Solapur
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Exempted
DIU SMART office solapur
24 Nov 2026
11 Nov 2026
24 Nov 2026
11 Nov 2026
23 Nov 2026
11 Nov 2026
11 Nov 2026 - 23 Nov 2026
19 Nov 2026
60 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation,Testing And Commissioning Of Fully Automatic Cleaning Grading Unit 1.5 TPH | - | - | - | - |
| 2 | Bucket Elevators-
Capacity: Minimum 2 TPH
Qty: 3 Nos.
Lift height: Minimum 12 ft / 3.6 m
Bucket: 1.5–2.5 litre food-grade HDPE/PP
Belt width: 150–200 mm
Belt: Heavy-duty endless belt
Motor: Minimum 1.5 HP
VFD: Yes
Feed hopper: Minimum 150–200 kg
Head/boot: MS fabricated
Belt tensioning: Adjustable
Belt tracking: Provided
Inspection/cleaning doors: Provided
Safety guards: Provided | 3 | Nos | - | - |
| 3 | Pre-Cleaner-
Capacity: Minimum 2 TPH
Screens: Minimum 2–3 decks
Approx. screen size: 750 × 1500 mm or equivalent
Screen cleaning: Ball/brush type
Screen material: MS/SS perforated sheet
Screen change: Easily removable
Aspiration: Adjustable air suction
Feed control: Adjustable
Motor: Minimum 3 HP
Approx. machine dimensions: 1800–2500 × 1000–1500 × 1800–2200 mm, or equivalent
Separate outlets for heavy/light impurities | 1 | Nos | - | - |
| 4 | Vibro Destoner 2TPH-
Capacity: Minimum 2 TPH
Deck size: approximately 900 × 1500 to 1000 × 1800 mm
Air adjustment: Variable
Feed rate control: Yes
Vibration adjustment: Yes
Separate stone outlet: Yes
Dust aspiration: Yes
Motor: 5 HP minimum
Machine construction: MS heavy-duty
Product-contact area: SS304 wherever applicable | 1 | Nos | - | - |
| 5 | Magnetic Separator-
Type: Magnetic Separator / Magnetic Drum
Capacity: Minimum 2 TPH
Magnetic intensity: Suitable for ferrous contamination removal
Contact parts: SS304
Magnet: Permanent high-intensity magnet
Width: 300–500 mm approximately
Separate cleaning arrangement
Motor: 2 HP only if motorized type | 1 | Nos | - | - |
| 6 | Gravity Seperator-
Capacity: Minimum 1.5 TPH
Type: Pneumatic/air-assisted gravity separator
Fan: 5 fan / blower arrangement
Deck: Vibratory inclined deck
Deck size: approximately 1000 × 2000 mm to 1200 × 2500 mm
Airflow: Adjustable
Deck inclination: Adjustable
Feed rate: Adjustable
Separate outlets: Minimum 3–4
Heavy/light fraction separation
Motor: 7.5 HP + 1 HP
Dust collection/aspiration: Provided
Cleaning arrangement: Provided | 1 | Nos | - | - |
| 7 | Fine Grader-
Capacity: Minimum 1.5 TPH
Type: Vibratory / rotary screen grader
Screen decks: Minimum 3
Screen size: 750 × 1500 mm approximately or equivalent
Interchangeable screens: Yes
Screen cleaning: Ball/brush arrangement
Number of grades: Minimum 3 + undersize
Separate discharge outlets
Adjustable feed
Motor: 3 HP minimum
Easy screen replacement
SS304 product-contact components wherever applicable | 1 | Nos | - | - |
| 8 | Aspirator-
Type: Multi-stage aspiration system
Capacity: Minimum 1.5–2 TPH
Qty: 4 Nos.
Blower: 3–5 HP each / as per manufacturer's design
Adjustable airflow
Air damper: Yes
Aspiration chamber: MS/SS
Dust outlet: Cyclone/bag filter arrangement
Ducting: MS/GI
Separate heavy/light material outlet
Inspection door: Yes | 4 | Nos | - | - |
| 9 | Storage Bins-
Capacity: Minimum 5 MT each
Qty: 2 Nos.
Material: MS fabricated / food-grade lining where required
Approx. dimensions: 2000 × 2000 × 1800–2200 mm, or equivalent
Bottom: Conical/angled discharge
Outlet: Minimum 200–300 mm
Slide gate: Provided
Level indicator: High/low level indication
Inspection hatch
Dust-tight construction
Support structure | 2 | Nos | - | - |
| 10 | Electrical Panel Board-
Complete electrical system shall be supplied on turnkey basis.
Main Electrical Panel
The panel shall include:
- MCC
- PCC as required
- PLC panel
- VFDs
- Motor starters
- Contactors
- Overload relays
- MCCBs/ACBs
- Short-circuit protection
- Phase protection
- Emergency stop circuit
- Indicating lamps
- Control transformers
- Energy metering
All panels shall be suitably designed for industrial flour-mill conditions. | 1 | Set | - | - |
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
rajmatacleaninggradingTenderdocnew.pdf
Tender Documents • 1.55 MB
BOQ_2310395.xls
BOQ • 0.30 MB
Datecorrigendum1.pdf
PDF • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .