Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹6.6 L+₹1.9 L (41.0%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹7.3 L+₹2.7 L (56.9%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹7.4 L+₹2.7 L (57.7%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | Rejected-Technical | - | Rejected-Technical Not eligible due to improper submission of Certificate of Fire Management Diploma |
| Sl No | Description | Qty | Unit | west bengal fire engineering and emergency protection co. L1 | Fire Shield Engineering & Equipments L4 | BALAJI FIRE PROTECTION SYSTEMS L2 | EVERSAFE FIRE INDUSTRIES INDIA PRIVATE LIMITED L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Deputation of Skilled Manpower atleast once a month for intensive checking of all the pumps installed for firefighting system including sequential operation of those pumps to check the performance of each pumps. The job includes checking of all pumps, control panels, pressure gauages, valves and other instruments installed inside and outside pump house and making necessary nominal rectifications / repair / replacement viz, gland packings, nut, bolts and washers, gaskets etc, if required to ensure proper functionality of the fire pumps including checking the storage of diesel to ensure smooth operation of diesel engine driven pump during emergency. Mock drill Test for fire pumps both in AUTO & MANUAL operations to be conducted during the visit once in a month and report of the test to be submitted to PWD for record. Video/ still Photography of mock drill is to be submitted to PWD for record purpose.
(i) All fire Pumps at five (05) number fire pump houses at Bankura Sammilani Medical College & Hospital premises (Submission of reports and video records to P.W.D. for documentation) | 60 | Per Job | 7,200 ₹4,32,000 Lowest | 11,400 ₹6,84,000 | 10,000 ₹6,00,000 | 11,000 ₹6,60,000 |
| 2.00 | Inspection of entire fire hydrant network at least once in a month and submission of report to PWD regarding any suggestions and for any leakage or damage of hydrant / landing valves or any other type of valves and instruments (water pipe lines etc.) for taking further course of action to ensure proper functionality of the installed fire-fighting system. The scope also includes minor repair / rectification viz change of gland packings, nuts bolts and washers, gaskets etc of all type of valves and other instrument installed such as replacement of worn out or damaged gasket etc. During inspection of water network, the vendor shall drain out water from risers and sprinkler lines and recharge it with set pressure after proper flushing on quarterly basis. Inlet valves of hydrant risers to be kept close after completion of flushing and recharging of water to avoid any accidental discharge of water. The agency will held sole responsible if the Fire Hydrant Systems will not work in demand of emergency due to any leakage or pilferage of water from any parts of the fire hydrant system which has not brought into the knowledge of PWD earlier.
(i) Whole Fire Hydrant and Sprinkler System in all rooms, ward, corridoor, office chambers & others at Main hospital building, Gynae building, Matrima building, Natun Bhavan building, OPD building, Cancer building, Super Specialty building, CCB building, Psychiatry Indoor building at Gobindanagar campus and Eye indoor building, Eye outdoor building, Administrative building, Medical record building at Lokepur campus of Bankura Sammilani Medical college & hospital Compound (Submission of reports and video records to P.W.D. for documentation). | 12 | Per Job | 3,000 ₹36,000 Lowest | 4,500 ₹54,000 | 5,000 ₹60,000 | 6,200 ₹74,400 |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
23 Jun 2026, 12:00 pmClosed
Executive Engineer, Bankura Division, PWD
Office of the Executive Engineer Bankura Division PWD Kenduadihi Bankura
Periodical inspection of fire fighting arrangement system and conducting mock drill on monthly basis for various hospital buildings and office buildings within the Bankura Sammilani Medical College and Hospital premises and submission of report and
2026_WBPWD_5015341_3
WBPWD/EE/BANKURA DIVISION/NIeQ-01/2026-2027
Open Tender
CIVIL WORKS
Item Rate
365 days
Bankura
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
15 Jul 2026
11 Jun 2026
25 Jun 2026
16 Jun 2026
23 Jun 2026
16 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Deputation of Skilled Manpower atleast once a month for intensive checking of all the pumps installed for firefighting system including sequential operation of those pumps to check the performance of each pumps. The job includes checking of all pumps, control panels, pressure gauages, valves and other instruments installed inside and outside pump house and making necessary nominal rectifications / repair / replacement viz, gland packings, nut, bolts and washers, gaskets etc, if required to ensure proper functionality of the fire pumps including checking the storage of diesel to ensure smooth operation of diesel engine driven pump during emergency. Mock drill Test for fire pumps both in AUTO & MANUAL operations to be conducted during the visit once in a month and report of the test to be submitted to PWD for record. Video/ still Photography of mock drill is to be submitted to PWD for record purpose.
(i) All fire Pumps at five (05) number fire pump houses at Bankura Sammilani Medical College & Hospital premises (Submission of reports and video records to P.W.D. for documentation) | 60 | Per Job | 1.25 | ₹75 |
| 2 | Inspection of entire fire hydrant network at least once in a month and submission of report to PWD regarding any suggestions and for any leakage or damage of hydrant / landing valves or any other type of valves and instruments (water pipe lines etc.) for taking further course of action to ensure proper functionality of the installed fire-fighting system. The scope also includes minor repair / rectification viz change of gland packings, nuts bolts and washers, gaskets etc of all type of valves and other instrument installed such as replacement of worn out or damaged gasket etc. During inspection of water network, the vendor shall drain out water from risers and sprinkler lines and recharge it with set pressure after proper flushing on quarterly basis. Inlet valves of hydrant risers to be kept close after completion of flushing and recharging of water to avoid any accidental discharge of water. The agency will held sole responsible if the Fire Hydrant Systems will not work in demand of emergency due to any leakage or pilferage of water from any parts of the fire hydrant system which has not brought into the knowledge of PWD earlier.
(i) Whole Fire Hydrant and Sprinkler System in all rooms, ward, corridoor, office chambers & others at Main hospital building, Gynae building, Matrima building, Natun Bhavan building, OPD building, Cancer building, Super Specialty building, CCB building, Psychiatry Indoor building at Gobindanagar campus and Eye indoor building, Eye outdoor building, Administrative building, Medical record building at Lokepur campus of Bankura Sammilani Medical college & hospital Compound (Submission of reports and video records to P.W.D. for documentation). | 12 | Per Job | 1.25 | ₹15 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.34 MB
2911-ii.pdf
Tender Documents • 0.58 MB
BOQ_5084094.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .