Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC 197 4 KANTADANGA ROAD FINGAPARA N24PGS PIN 743129 | FINGAPARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹31.2 L+₹66,813.50 (2.19%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹32.4 L+₹2.0 L (6.40%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹32.8 L+₹2.3 L (7.49%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹36.7 L+₹6.2 L (20.3%)Rejected-Finance VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
9 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJOR VIPIN BHATT
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIR AND MAINTENANCE OF LT DISTRIBUTION SYSTEM WITH ALLIED WORKS, REPAIR /MAINT OF STREET LIGHTS AND CONNECTED REPAIR WORKS OF DOMESTIC AND TECH AREA AT AIR FORCE STATION SALUA UNDER GE (AF) KALAIKUNDA
2022_MES_539614_1
8763/E8
Open Tender
Electrical and Maintenance Works
Item Rate
360 days
AF STN SALUA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹60,000
Yes
29 Sept 2022
20 Jul 2022
10 Aug 2022
20 Jul 2022
9 Aug 2022
4 Aug 2022
Amount
Comprehensive maintenance for a period of twelve months of DG sets of capacity 20 KVA installed at various location by cleaning, Oiling,Greasing, topping, calibration, repairs to diesel engine and including replacement of spares parts like clamps, V- Belt of any size,pipe with fittings, check the level of coolant in radiator, repairs to leakage in radiator etc. Gaskets & Oil seals, servicing of the Water Pump, calibration of fuel injection pump,repairs of Self Starter, Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including Repair/Replacement off toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed. (Make: Cummins/ Kriloskar/ Ashok Leyland)
All as per above item No.01 here in before but 30 KVA DG set complete all as specified and as directed.
All as per above item No.01 here in before but 82.5 KVA DG set complete all as specified and as directed.
All as per above item No.01 here in before but 125 KVA DG set complete all as specified and as directed.
All as per above item No.01 here in before but 250 KVA DG set complete all as specified and as directed.
NOTES:- (Applicable for BOQ Serial Item No. 1 & 5 here in before) (i) The Contractor shall provide the following comprehensive services arising out of wear and tear of the normal running of DG Sets (ii) Preventive and Corrective Maintenance : The authorised Service Engineer of OEM or OEM Certified agencies shall visit the site once in a month for carrying out preventive and corrective maintenance on all the units installed at site. This includes maintenance of all mechanical, electrical and electronic parts / sub-assemblies. The preventive maintenance report will be as per the Original Equipment Manufacturer's instructions and as specified in Particular Specification. The Contractor may claim payment on monthly basis. In that case the payment shall be made with pro-rata basis on quoted rates. (iii) Breakdown Maintenance : The Authorised Service Engineer of OEM or OEM Certified Agencies will carry out all breakdown maintenance after receiving information (written or oral) from GE (AF) Kalaikunda officials or their representatives, The OEM's authorised service representative or OEM certified agencies will carry out the required repairs of the units and appraise GE,Engineer-in-Charge and JE the status of the break down repair at site. No payment shall be made on account of any breakdown service during comprehensive maintenence period.
(iv) The Service Engineer will be called in case of any breakdown and the same shall be attended within 24 Hours of lodging of complaint, failing which a penal recovery of Rs.500.00 (Rupees Five Hundred Only) per day till such time the unit is attended and complaint is resolved,will be recovered from the outstanding dues to the Contractor. (v) Cost of minor items like teflon tape, metal washers, fibre/rubber washers, screws, small nuts & bolts and like shall be deemed to be inclusive of the quoted rate. (vi) Spares required for replacement of defective ones will be measured and paid seperately under Prime Cost Sum (vii) The Contractor shall maintain service reports for all visits & breakdown visits & copy of the same will be submitted every month to the Engineer in Charge.
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and n.exe 1.5 mtr depth including getting out all as specified and directed. Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor beyond every hours till services restored .
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available Fly ash brick for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete including demolition of existing all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete and demolition of existing all as specified and directed by Engineer- in-charge.
Disconnecting and Taking out unserviceable, U/G cables, 1100 Volts grade from trenches/ducts/ poles etc of any size complete all as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3½ core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 95 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
All as per item No 14 here-in-before but of size 70 Sqmm 3.5 core complete all as specified and as directed.
All as per item No 14 here-in-before but of size 50 Sqmm 3.5 core complete all as specified and as directed.
All as per item No 14 here-in-before but of size 35 Sqmm 3.5 core complete all as specified and as directed.
All as per item No 14 here-in-before but of size 25 Sqmm 3.5 core complete all as specified and as directed.
All as per item No 14 here-in-before but of size 16 Sqmm 4 core complete all as specified and as directed.
All as per item No 14 here-in-before but of size 10 Sqmm 4 core complete all as specified and as directed.
Material and labour for 40 mm dia galvanized iron tube Light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, including including all fitting clamps, nut, bolt and washers complete all as specified and directed.
All as per item Serial No 21 here-in-before but for 50 mm dia pipe complete all as specified and directed.
All as per item Serial No 21 here-in-before but for 80 mm dia pipe complete all as specified and directed.
Horizontal boring of holes, under road/ pavement / hard standing etc.,not exceeding 15 Metres in length, in any type of soil, suitable for passing through 40 to 50 mm bore, galvanised steel tubing, complete all as specified and directed.
Horizontal boring of holes, under road/ pavement / hard standing etc.,not exceeding 15 Metres in length, in any type of soil, suitable for passing through 80 to 100 mm bore, galvanised steel tubing,complete all as specified and directed.
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 63 Amps and 10 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, complete all as specified and directed.
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 100 Amps and 16 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In,complete all as specified and directed.
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 125 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, complete all as specified and directed. [Cat No. CM90642OOLO of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 160 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In,complete all as specified and directed. [Cat No. CM90642OOMO of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
Supply and Fix in repairs,moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 200 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In, complete all as specified and directed. [Cat No. CM90642OONO of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
All as per Item No 30 here-in-before but of capacity 250 Amps, 36 KA breaking capacity complete all as directed. [Cat No. CM92109OOP1OG of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
Taking down unserviceable street /flood light / Security light fittings any type or any capacity from any location mounted on any type of Poles/Bdgs/ / Tower/ High mast of height up to 18 mtr from bracket after disconnecting of supply cable and refixing the same after carrying out repair and testing on exiting or new location as per site requirement, including repairing of circuit, electrical connection, replacement of defective driver, surge protection device, tracing and rectifying of fault complete all as specified and as directed by Engineer-in-Charge. Note : (i) Supply LED driver with SPD and electric supply cable will be will be deemed to be included under respective item.) (ii) All T&P, ladder etc required at site for the repairing and taking down / refixing of light fitting after repair shall be arranged by the contractor. (iii) If there is any fault in electrical supply line, it shall be contractor liability to identify the fault and get it repair for making the light functional complete all as directed .
S & F LED street lights nominal power 35 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 2500, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with epoxy powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No.LR02-391-XXX-57-XX of Wipro or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 including taking out unserviceable complete all as specified and as directed.
S & F LED street lights nominal power 60 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 6000, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LR02-671-XXX-57-XX of Wipro or Make:- Crompton Cat No. No.Raptor Neo I , Cat No. TRP-409-60-57-SL-GL-NSG OR equivalent of Make mentioned under Particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 including taking out unserviceable complete all as specified and as directed.
S & F LED street lights nominal power 70 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 7000, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LR02-781-XXX-57-XX of Wipro or equivalent of Make mentioned under Appendix of PS including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 including taking out unserviceable complete all as specified and as directed.
S & F LED flood lights nominal power 120 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LF20-132-060-57-XX of Wipro or equivalent of Make mentioned under Appendix "B" including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. Note for Item No. 68 to 71(i) If connection.cable from pole Juction box to street light and street light bracket up to 2 mtrs be included and measured in unit rate item, Beyond 2 mtrs of length to be paid seperately under respective items.
Note for item no. (ii) At location where street lights/flood light are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED street light/flood lights shall be properly connected with earth dolly provided with fittings and steel poles earth bolt. (iv)All LED lights have replacement warranty of 3 years from the date of completion of the contract accordingly condition 46 of GCC (IAFW-2249) shall be amended to extent mention above. Contractor has to submitt warranty certificate from manufacturer . Payment of light fitting will be released after receipt of 3 year replacement warranty certificate from manufacturer. (v) The LED lights will replaced by the contractor free of cost in the case of manufacturing defects and Failure due to electrical impact if not connected properly with earth. Hence it is contractor responsibility to connect the light fitting earth wire and shall be grounded properly. (vi) The contractor shall submit the surge protection certificate and Type test certificate LM 79, LM 80 for luminaries. (vii) All LED fitting shall be identified by printing or fixing stickers duly mentioned the C.A number and date of completion. (viii) For any change in product or change in catalogue No. etc due to technological upgradation, letter has to be obtained from the lighting company on their letter head signed by an offical of National level. (ix) All T& P required at site for installation of light on Pole / Bldg /Tower or at any location shall be arranged by contractor.
M&L for FRLS wiring in existing locatation for circuit alongwith earth wire 2 x 2.5 sqmm + 1 x 1.5 Sqmm copper cable PVC insulated multistranded from junction box to fitting connecting box etc. (Two run of 2.5 Sqmm wire+01 Run of 1.5 Sqmm wire considered as one unit) all as specified and as directed.
Material and Labour for applying two coats of aluminium paint on old painted surfaces of steel tubular poles, type 410 SP-22/ SP-31 (8.5/9.00 Metres Long), including cross arms,brackets etc., up to 1.5 M above PCC base and marking alternate strip horizontally of width 15 cm with two coats of synthetic enamel paint (ordinary tint) above PCC base up to 1.5 M height and numbering of poles with letters and figures of height 75 mm at a height of 2.60 metre from ground level including preparation of surfaces complete all as specified and directed.
Material and Labour for applying two coats of aluminium paint on old painted surfaces of steel tubular poles, type 410 SP-41 (11 Metres Long), including cross arms,brackets etc., up to 1.5 M above PCC base and marking alternate strip horizontally of width 15 cm with two coats of synthetic enamel paint (ordinary tint) above PCC base up to 1.5 M height and numbering of poles with letters and figures of height 75 mm at a height of 2.60 metre from ground level including preparation of surfaces complete all as specified and directed.
Supply and fixing copper strip of size 20 x3.15 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulator ( ceramic bus bar support insulator off white colour of min size of 36 mm width x 60 mm length with 36 mm width bus bar mounting base) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including copper strip brazing to each joints and connected with by providing brass nut bolts and washers all as specified and directed by Engr in Charge
Supply and fixing in repair copper strip of size 32 x 6 mm as earth continuity conductor or main earthing lead fixed on "V" type porcelain insulator ( ceramic bus bar support insulator off white colour of min size of 36 mm width x 60 mm length with 36 mm width bus bar mounting base) saddle to wall, buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3 mm copper strip brazing to each joints and connected with by providing brass nut bolts and washer all as specified and directed by Engr in Charge.
S&F in replacement of Porcelain insulator of existing size for isolation of conductor from the building wall by providing 15cm long fastners complete all as specified.
M&L for earthing complete with copper earth plate electrode 600x600x3.15mm thick buried directly in ground (Earth plate not less than 3.0 M in deep below ground level) with top edge of the plate not less than 2.4m below normal ground level connected to copper earth strip 20X3 mm by means earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earthing test point all as specified and directed including necessary earth work in any type of soil/hard rock strata and PCC 1:3:6 type B1 for chamber and RCC chamber cover 50mm thick in lieu of CI cover and copper strip protected by 40mm GI pipe light grade complete. Including filling of agriculture soil brought from out side defence land for earth pit as directed by Engineer-in-charge. Excavation and removal of excavated soil and filling of agriculture soil brought from out side defence land shall be included in the overall rate quated. No extra payment shall be paid. Note :- (a). The quoted rate includes the rate of Magnesium Sulphate of 40Kg per earth pit poured with salt and charcoal (To obtained earth resistance value and prepare test sheet of newly constructed earth pit shall be responsibility of contractor and submitted to Engineer- incharge ) (b). If the desired earth resistance not obtained the earthing shall be re-done by contractor without any extra cost to Govt . (c) 40 mm dia light grade GI pipe for earth lead strip protection and earth strip up to 7.5 Mtr incl in quoted rates beyond that both are measured and paid separetely. All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate.(d). Cost of brazing/ welding and brass nut bolts and washer are deemed to be included in the unit rate.6. Cost includes disposal of excavated soil from site and clear the site before completion of work at that location
Supply only back filling compound (Magnesium sulphate ) in existing earth pits through G I pipes as per site requirment all as directed .
M&L for carrying out brazing to earthing strip joint between earthpit and test point after removing the nut bolt ,scraping the strip,preparing the surface all as specified by Engr-in-charge
Prime Cost Sum. The prime cost to be used as directed by the Accepting Officer vide Condition 1 (v) and 5 of IAFW-2249 (General Condition of Contracts) forming part of the tender documents. (a) Provide a prime cost of Rs 4,00,000.00 for supply only of spare parts suitable for various capacities of DG Sets, Pump Sets & Dosing Pumps and Rewinding of Electric Motors/Alternators after dismantling and based on findings of the actual requirements of spares/burnt out windings for rewinding, through a BOO convened by the Accepting Officer.The spares shall procured directly from the OEMs or their aurhorised distributor/dealer as approved by GE. Rewinding of electric motors/alternators shall be done through authorised Service Engineer of OEM or OEM Certified Agencies as approved by GE. (b) Bidder's/Contractor's quoted amount shall be inclusive of his overhead and profit and including all taxes and insert amount to cover all. The Bidder's/Contractor's is to quote lump sum amount under Column 6 covering all the aspects mentioned here in before, representing (%) percentage under Column 9, Above/Below (+ or - denomination) the Prime Cost Sum insered by MES under Column 5. However,the quoted amount under Column 6 shall not exceed 15% (Fifteen Percentage) of Prime Cost Sum insered by MES under Column 5. In case,the Bidder's/Contractor's quoted amount is in excess of 15% of the estimated amount, the same shall be restricted to 15% (Fifteen Percentage) and the amount quoted shall be corrected accordingly to work out the contract sum.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .