Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 CrAccepted-AOC | ₹4.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹4.8 Cr+₹6.3 L (1.34%)Rejected-Finance | ₹4.8 Cr+₹6.3 L (1.34%) | L2 | Rejected-Finance L2 |
| 3 | L3₹4.9 Cr+₹14.0 L (2.95%)Rejected-Finance | ₹4.9 Cr+₹14.0 L (2.95%) | L3 | Rejected-Finance L3 |
| 4 | L4₹5.0 Cr+₹29.6 L (6.24%)Rejected-Finance AT ST17 VASHI NEW MUMBAI | ₹5.0 Cr+₹29.6 L (6.24%) | L4 | Rejected-Finance L4 |
| 5 | L5₹5.0 Cr+₹30.7 L (6.47%)Rejected-Finance | ₹5.0 Cr+₹30.7 L (6.47%) | L5 | Rejected-Finance L5 |
Tender Value
₹4.9 Cr
EMD Value
₹2.4 L
Closing Date
27 Nov 2020, 5:00 pmClosed
office of the Superintending Engineer
office of the Superintending Engineer (PMGSY), MRRDA, Konkan Region, Thane
Upgradation and Maintenance of A) Adeli Bhatwadi Shambhu bhavani Vetore Road , B)Kochara Umbarache Pani Road C) Aravali Sakhekhol Asoli road D) Redi Soudagarwadi road Tal- Vengurla Dist-Sindhudurg
2020_MMGSY_620761_3
SE/MMGSY/KON/SIN/ADB2019-20/2
Open Tender
Civil Works - Roads
Item Wise
365 days
VENGURLA
AS PER NIT
10 documents required · 10 mandatory
₹11,200
₹2.4 L
23 Apr 2021
2 Nov 2020
1 Dec 2020
2 Nov 2020
27 Nov 2020
19 Nov 2020
2 Nov 2020 - 17 Nov 2020
Amount
Bill No. 1 Site Clearance, Dismantling and Earth Works
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. In area of Non thorny jungle
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. In area of thorny jungle
Cutting of trees, including cutting of trunks, branches and removal of stumps and roots, refilling compaction of back filling and stacking of serviceable material by manual means with all lifts asper Technical Specification clause 201 Lead upto 1000 m. Girth from 300 to 600 mm
Cutting of trees, including cutting of trunks, branches and removal of stumps and roots, refilling compaction of back filling and stacking of serviceable material by manual means with all lifts asper Technical Specification clause 201 Lead upto 1000 m. Girth from 600 to 900 mm
Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 mExcavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with all lifts upto 1.5 m & lead up to 1000 m, as per Technical Specification Clause 302.3
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5
Excavation in Hard Rock (requiring blasting) with disposal upto 1000 m Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5
Excavation for roadway in hard rock with controlled blasting by drilling blasting and breaking trimming of bottom and side slopes in accordance with requirements of lines grades and cross sectiond loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical specification clause 302.3.5 (iii
Excavation in Hard Rock (blasting prohibited)Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5
Construction of Embankment with material obtained from Road way cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of Embankment with material obtained from Borrw pit Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Compacting Original Ground Preparation and surface treatment of formation by removing mud and slurry, watering to the extent needed to maintain the desired moisture content, trimming to the required line, grade, profile and rolling with three wheel 80-100 kN static roller, complete.
Dismanteling Stone Masonary -Dismentaling of exisiting structure like culvert, bridges, retaining walls and other structure comprsing of masonary,cement concrete, wood work, steel work, including T & P and sacffolding whereever necessary, sorting the dismantled material etc. complete with all lifts and lead of 1000 mt as per technical Specification clause 202
Removing all types of Hume pipes and Stacking with a lead of 1000 m including earthwork and Dismentaling of masonary work as per technical specifications clause 202. 600mm to 900 mm Dia.
Bill No. 2 Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
Granular Sub-base with Well Graded Material- By mix in Place method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.grade I material
Water Bound Macadam GRADE II Sub-base/base Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. By Mechanical Means
Modified Penetration Macadam Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506 . 50 mm thick , using bitumen S-65 ( VG30)
20mm thick Open-Graded Premix Carpet using Bituminous with s-65 bitumen Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades followed by seal coat of either Type A or B, or C, as per Technical Specification Clause 508. (Excluding Sealcoat )
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A or B, or C, as per Technical Specification Clause 510 . using bitumen S-65 ( VG30)
Bill No. 3 Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.(in soft soil ) up to 3.00 m depth by mechanical means
Earthwork in Excavation for foundation of structure upto 3 mt depth as per drawing and technical specification including setting out, construction of shoringand bracing, removal of stumps and other deleterious matter, dressing of side and bottom and backfilling with approved material etc. complete.(In Hard Rock) blasting prohibited
Providing concrete for plain concrete in open foundation complete as per drawing and technical specifications Clause 802,803,1202 &1203 for P C C Grade M-10 nominal mix 1:3:6
Providing concrete for plain concrete in open foundation complete as per drawing and technical specifications Clause 802,803,1202 &1203 for P C C Grade M-15 nominal mix (1:2.5:5)
Plain cement concrete in substructure complete as per drawing and technical specification.clause 802,804,805,806,807,1202, 1204 for height up to 5.0 m for PCC M-15 nominal mix 1:2.5:5 For substructure
Providing and laying reinforced cement concrete 1000 mm dia. RCC pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.
Providing and laying reinforced cement concrete 600 mm dia pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 Granular Material
Dewatering including diversion of stream providing cofferdom,bunds,etc as may be necessary for foundation and other parts of work and bailing out water during and after excavation as required. Raft & Cut off Wall
Dewatering including diversion of stream providing cofferdom,bunds,etc as may be necessary for foundation and other parts of work and bailing out water during and after excavation as required. Return
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 For RCC M-20 for cut off wall
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 M-20 for Pier and abutment and Returns
Plain/Rreinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 For RCC cap grade M-25
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 For R C C Slab in M-25 and curbing
Providing pressure relife pipe 100 mm dia . In bottam slab of box cell on a filtter meadia base of 500 mm x 500 mm as per drawing and technical specification clause 1205.5.7
Sand Filling - Filling( sand) in foundataion trenches as per detailed drawing and technical specification clause 305.3.9
Providing and fixing in position pipe railing consisting of IS Rolled steel joist posts designation IS MB 100 (100x75) at 2.5 m interval and three rows of 50 mm dia steel pipes (light) including fixing in position on bridge deck complete as per drawing
Providing Tar paper bearing of approved quality in proper size etc. complete (Rate as per PWD CSR 2020-21) BR Item no.13.02 Pg no 118
Expansion joint with 25 mm thich bitumenous pad / Compressible Rubber Pad (Rate as per PWD CSR for 2018-19)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 For RCC M-25 for raft slab
Supplying ,fitting and placing TMT bar reinforcement (Fe 415)in Superstructure complete as per drawings and technical specification Clauses 1002,1005,1010,and 1202 For Foundation
Supplying ,fitting and placing TMT bar reinforcement (Fe 415)in Superstructure complete as per drawings and technical specification Clauses 1002,1005,1010,and 1202 For Sub structure
Supplying ,fitting and placing TMT bar reinforcement (Fe 415)in Superstructure complete as per drawings and technical specification Clauses 1002,1010,and 1202 Steel for Superstructure
Providing and laying in position 90 cm thick flexible stone mat as per detailed drawing including laying and compaction consolidation 15 cm to 23 cm soling consolidation of 60 mm size metal in two layers and compaction of 10 cm layers in single layer with watering etc complete including lead of 50mt.
Construction Joints Providing and filling joints sealing compound as per drawing and technical specification with corse sand and 6% bitumen by weight.
Providing and laying cement concrete wearing course M 30 grade excluding reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Providing weep holes in plain/reinforced concrete abutment,wing wall,return wall with 100 mm dia. Pvc pipe extending through the full width of the structures with slope of 1(v):20 (h) towards drawing face complete as drawing and technical specification clause 614,709,1204,3.7
filter media Providing and laying filter media with granular crushed aggregates asper specification to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete asper drawing and technical specification Clause 1204.3.8
Providing amd laying reinforced cement concrete pipes NP2 for culvarts on first class bedding of granular material in single row including providing fixing collers in cement morter 1:2 but excluding excavation , protction works , backfilling concrete and masonary works in head walls and parapets clause 1106 600 mm diameter
Only labour chargesfor laying old RCC pipe
Painting two coats on new concrete surface paintig two coats including primer coat after filling the surface with syathnic enameled pain in all shades on new plastered / concrete surface as per drawing and technical specification clause 1701
Printing new letters and figures of any shade printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical specification Clause 1701 English / roman
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 Stone / boulder
Boulder Appron Providing and laying of boulder apron laid in wire crates with 4mm dia GI wire confirming ti IS 280 and IS 4826 in 100mm x 100mm (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications .clause 1301
Providing Latrite stone masanary in cm 1:6 for foundation and plinth including striking joints on the unexposed faces and watering complete. ( latrite stone six sides cut and thickness of morter joints be 12 mm max.)
Bill No. 4 Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 200 m stone (precast)
Guard Stone Providing and fixing Reinforced cement concrete M-15 grade Gaurd Stone of Size 20x20x75 cm including fixing in ground and white washing etc. complete
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with areas not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm - 3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M 20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level complete (as per MoRT&H specification No.801) (for area Less than 0.9 sqm). 7Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Traffic Signs 900 mm equilateral triangleProviding and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 900 mm equilateral triangle
Traffic Signs 900x 600 mm RectangularProviding and Fixing of Retro Reflectorised Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Traffic Signs 600x 450 mm Rectangular Providing and Fixing of Retro Reflectorised Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Traffic Signs 600 mm circular Providing and Fixing of Retro Reflectorised Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
Providing and applying hot applied tharmoplastic reflective pavaement paint, marking paint for trafic lane strip 100 mm wide and 3mm tk. On road surface with 10% of binder and 60 % fillar materrial as per MORT and H specification including cleaning road surface with all dirt, dust and other foren materials demarcating of the site managing the traffic etc. complete with three years garantee
Supplying and fixing of molded shank raised pavement markers/ cat's eyes made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 type H and complying to specifications of category A of MORTH circular no RW/NH/33023/10-97 DO III Dt.11.06.1997.The height,width and length shall not exceed 50mm,100mm and 100 +/-2 mm with minium reflective area of 13 sqcm on each side and the slope to the base shall be 35 +/-5 degree The strength of detachment of the integrated cylindrical shanks( of diameter not less than 19+/-2 mm and height not ledd than 30+/-2 mm) from the body is to be a minium value of 500 kg.fixing will be by drilling holes on the road for the shanks to go inside without nails and using epoxy resin based adhesive as per manufactures recommendation and complete as directed by the engineer The contractor shall submit a two year warranty for satisfactory field performance ancluding stipulated retro-reflectance of the reflecting panel to the engineer
Road Delineators supplying and installation of delineators( roadway indicators Hazard markers object markers) 80 to 100 cm high above ground level painted black and white in 15 cm wide strips fitted with 80x100 rectangular or 75 mmdia circular reflectorised panels at the top burried or pressed into the ground and confirming to IRC 79 and the drawings
Shifting of Eletric Line/ Teliphone Line Pole Removal of teliphone/ electric poles with wire including excavation and dismantaling of foundation concrete and lines under the supervision of concerned department disposal with all lifts and up to lead of 1000 m and stacking the serviceable material separately as per technical specification clause 202
Pipe line shifting shifting of water supply line distmentling of exis tng water supply line and providing new water supply iine of pvc pipe 90mm PVC Of 6 Kg.
Bill No. 1 Site Clearance, Dismantling and Earth Works
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. In area of Non thorny jungle
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. In area of thorny jungle
Cutting of trees, including cutting of trunks, branches and removal of stumps and roots, refilling compaction of back filling and stacking of serviceable material by manual means with all lifts asper Technical Specification clause 201 Lead upto 1000 m. Girth from 300 to 600 mm
Cutting of trees, including cutting of trunks, branches and removal of stumps and roots, refilling compaction of back filling and stacking of serviceable material by manual means with all lifts asper Technical Specification clause 201 Lead upto 1000 m. Girth from 600 to 900 mm
Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 mExcavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with all lifts upto 1.5 m & lead up to 1000 m, as per Technical Specification Clause 302.3
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5
Excavation in Hard Rock (requiring blasting) with disposal upto 1000 m Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5
Excavation for roadway in hard rock with controlled blasting by drilling blasting and breaking trimming of bottom and side slopes in accordance with requirements of lines grades and cross sectiond loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical specification clause 302.3.5
Excavation in Hard Rock (blasting prohibited)Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5
Construction of Embankment with material obtained from Road way cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of Embankment with material obtained from Borrw pit Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Compacting Original Ground Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.
Dismanteling Stone Masonary -Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202.
Removing all types of Hume pipes and Stacking with a lead of 1000 m including earthwork and Dismentaling of masonary work as per technical specifications clause 202. 600mm to 900 mm Dia.
Bill No. 2 Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
Granular Sub-base with Well Graded Material- By mix in Place method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.grade I material
Water Bound Macadam GRADE II Sub-base/base Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. By Mechanical Means
Modified Penetration Macadam Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506 . 50 mm thick , using bitumen S-65 ( VG30)
20mm thick Open-Graded Premix Carpet using Bituminous with s-65 bitumen Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades followed by seal coat of either Type A or B, or C, as per Technical Specification Clause 508. (Excluding Sealcoat )
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A or B, or C, as per Technical Specification Clause 510 . using bitumen S-65 ( VG30)
Granular Sub base with well Granded material (table 400.1 )(A) Mix in place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.(ii) for grading II material
Bill No. 3 Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.(in soft soil ) up to 3.00 m depth by mechanical means
Earthwork in Excavation for foundation of structure upto 3 mt depth as per drawing and technical specification including setting out, construction of shoringand bracing, removal of stumps and other deleterious matter, dressing of side and bottom and backfilling with approved material etc. complete.(In Hard Rock) blasting prohibited
Providing concrete for plain concrete in open foundation complete as per drawing and technical specifications Clause 802,803,1202 &1203 for P C C Grade M-10 nominal mix 1:3:6
Providing concrete for plain concrete in open foundation complete as per drawing and technical specifications Clause 802,803,1202 &1203 for P C C Grade M-15 nominal mix (1:2.5:5)
Plain cement concrete in substructure complete as per drawing and technical specification.clause 802,804,805,806,807,1202, 1204 for height up to 5.0 m for PCC M-15 nominal mix 1:2.5:5 For substructure
Providing and laying reinforced cement concrete 1000 mm dia. RCC pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.
Providing and erecting W metal beam crash barrier comrrising of 3 mm tk corrugated sheet metal beam rail 70 cm above road / ground leval fixed on ISMC series channel vertical post 150x75x5 mm spaced 2 m c to c ,1.8 m high, 1.1 m below ground road level all steel parts and fitting to be galvanised by not dip process all fittings to conform to IS : 1367 and IS: 1364 metal beam rail to be fixed on the vartical post with a spacer of channel section 150x75x6 mm , 330 mm long complete as per clause 810 including excavation for crash barrier foundation 500x500x950 mm and concrete M20 in foundation block 350x350x950 mm etc complete.
Providing and laying reinforced cement concrete 600 mm dia pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.
Providing weep holes in plain/reinforced concrete abutment,wing wall,return wall with 100 mm dia. Pvc pipe extending through the full width of the structures with slope of 1(v):20 (h) towards drawing face complete as drawing and technical specification c
filter media Providing and laying filter media with granular crushed aggregates asper specification to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete asper drawing and technical specification Clause 1204.3.8
Providing amd laying reinforced cement concrete pipes NP2 for culvarts on first class bedding of granular material in single row including providing fixing collers in cement morter 1:2 but excluding excavation , protction works , backfilling concrete and masonary works in head walls and parapets clause 1106 600 mm diameter
Only labour chargesfor laying old RCC pipe
Painting two coats on new concrete surface paintig two coats including primer coat after filling the surface with syathnic enameled pain in all shades on new plastered / concrete surface as per drawing and technical specification clause 1701
Printing new letters and figures of any shade printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical specification Clause 1701 English / roman
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 Stone / boulder
Boulder Appron Providing and laying of bolder apron laid in wire crates with 4mm dia GI wire confirming ti IS 280 and IS 4826 in 100mm x 100mm (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications .clause 1301
Providing Latrite stone masanary in cm 1:6 for foundation and plinth including striking joints on the unexposed faces and watering complete. ( latrite stone six sides cut and thickness of morter joints be 12 mm max.)
Bill No. 4 Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 200 m stone (precast)
Guard Stone Providing and fixing Reinforced cement concrete M-15 grade Gaurd Stone of Size 20x20x75 cm including fixing in ground and white washing etc. complete
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with areas not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm - 3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M 20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level complete (as per MoRT&H specification No.801) (for area Less than 0.9 sqm). 7Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Traffic Signs 900 mm equilateral triangle Providing and Fixing of Retro Reflectorised Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 900 mm equilateral triangle
Traffic Signs 900x 600 mm Rectangular Providing and Fixing of Retro Reflectorised Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Traffic Signs 600x 450 mm Rectangular Providing and Fixing of Retro Reflectorised Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Traffic Signs 600 mm circularProviding and Fixing of Retro Reflectorised Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
Providing and applying hot applied tharmoplastic reflective pavaement paint, marking paint for trafic lane strip 100 mm wide and 3mm tk. On road surface with 10% of binder and 60 % fillar materrial as per MORT and H specification including cleaning road surface with all dirt, dust and other foren materials demarcating of the site managing the traffic etc. complete with three years garantee
Supplying and fixing of molded shank raised pavement markers/ cat's eyes made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 type H and complying to specifications of category A of MORTH circular no RW/NH/33023/10-97 DO III Dt.11.06.1997.The height,width and length shall not exceed 50mm,100mm and 100 +/-2 mm with minium reflective area of 13 sqcm on each side and the slope to the base shall be 35 +/-5 degree The strength of detachment of the integrated cylindrical shanks( of diameter not less than 19+/-2 mm and height not ledd than 30+/-2 mm) from the body is to be a minium value of 500 kg.fixing will be by drilling holes on the road for the shanks to go inside without nails and using epoxy resin based adhesive as per manufactures recommendation and complete as directed by the engineer The contractor shall submit a two year warranty for satisfactory field performance ancluding stipulated retro-reflectance of the reflecting panel to the engineer
Road Delineators supplying and installation of delineators( roadway indicators Hazard markers object markers) 80 to 100 cm high above ground level painted black and white in 15 cm wide strips fitted with 80x100 rectangular or 75 mmdia circular reflectorised panels at the top burried or pressed into the ground and confirming to IRC 79 and the drawings
Shifting of Eletric Line/ Teliphone Line Pole Removal of teliphone/ electric poles with wire including excavation and dismantaling of foundation concrete and lines under the supervision of concerned department disposal with all lifts and up to lead of 1000 m and stacking the serviceable material separately as per technical specification clause 202
Pipe line shifting shifting of water supply line distmentling of exis tng water supply line and providing new water supply iine of pvc pipe 90mm PVC Of 6 Kg.
Bill No. 1 Site Clearance, Dismantling and Earth Works
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. In area of Non thorny jungle
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. In area of thorny jungle
Cutting of trees, including cutting of trunks, branches and removal of stumps and roots, refilling compaction of back filling and stacking of serviceable material by manual means with all lifts asper Technical Specification clause 201 Lead upto 1000 m. Girth from 300 to 600 mm
Cutting of trees, including cutting of trunks, branches and removal of stumps and roots, refilling compaction of back filling and stacking of serviceable material by manual means with all lifts asper Technical Specification clause 201 Lead upto 1000 m. Girth from 600 to 900 mm
Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 mExcavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with all lifts upto 1.5 m & lead up to 1000 m, as per Technical Specification Clause 302.3
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5
Excavation in Hard Rock (requiring blasting) with disposal upto 1000 m Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5
Excavation for roadway in hard rock with controlled blasting by drilling blasting and breaking trimming of bottom and side slopes in accordance with requirements of lines grades and cross sectiond loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical specification clause 302.3.5 (iii
Excavation in Hard Rock (blasting prohibited)Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5
Construction of Embankment with material obtained from Road way cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of Embankment with material obtained from Borrow pit Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Compacting Original Ground Preparation and surface treatment of formation by removing mud and slurry, watering to the extent needed to maintain the desired moisture content, trimming to the required line, grade, profile and rolling with three wheel 80-100 kN static roller, complete.
Dismanteling Stone Masonary -Dismentaling of exisiting structure like culvert, bridges, retaining walls and other structure comprsing of masonary,cement concrete, wood work, steel work, including T & P and sacffolding whereever necessary, sorting the dismantled material etc. complete with all lifts and lead of 1000 mt as per technical Specification clause 202
Removing all types of Hume pipes and Stacking with a lead of 1000 m including earthwork and Dismentaling of masonary work as per technical specifications clause 202. 600mm to 900 mm Dia.
Bill No. 2 Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
Granular Sub-base with Well Graded Material- By mix in Place method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.grade I material
Water Bound Macadam GRADE II Sub-base/base Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.material obtained from Borrow pit
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. By Mechanical Means
Modified Penetration Macadam Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506 . 50 mm thick , using bitumen S-65 ( VG30)
20mm thick Open-Graded Premix Carpet using Bituminous with s-65 bitumen Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades followed by seal coat of either Type A or B, or C, as per Technical Specification Clause 508. (Excluding Sealcoat )
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A or B, or C, as per Technical Specification Clause 510 . using bitumen S-65 ( VG30)
Bill No. 3 Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.(in soft soil ) up to 3.00 m depth by mechanical means
Earthwork in Excavation for foundation of structure upto 3 mt depth as per drawing and technical specification including setting out, construction of shoringand bracing, removal of stumps and other deleterious matter, dressing of side and bottom and backfilling with approved material etc. complete.(In Hard Rock) blasting prohibited
Providing concrete for plain concrete in open foundation complete as per drawing and technical specifications Clause 802,803,1202 &1203 for P C C Grade M-10 nominal mix 1:3:6
Providing concrete for plain concrete in open foundation complete as per drawing and technical specifications Clause 802,803,1202 &1203 for P C C Grade M-15 nominal mix (1:2.5:5)
Plain cement concrete in substructure complete as per drawing and technical specification.clause 802,804,805,806,807,1202, 1204 for height up to 5.0 m for PCC M-15 nominal mix 1:2.5:5 For substructure
Providing and laying reinforced cement concrete 1000 mm dia. RCC pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.
Providing and laying reinforced cement concrete 600 mm dia pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.
Providing weep holes in plain/reinforced concrete abutment,wing wall,return wall with 100 mm dia. Pvc pipe extending through the full width of the structures with slope of 1(v):20 (h) towards drawing face complete as drawing and technical specification clause 614,709,1204,3.7
filter media Providing and laying filter media with granular crushed aggregates asper specification to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete asper drawing and technical specification Clause 1204.3.8
Providing amd laying reinforced cement concrete pipes NP2 for culvarts on first class bedding of granular material in single row including providing fixing collers in cement morter 1:2 but excluding excavation , protction works , backfilling concrete and masonary works in head walls and parapets clause 1106 600 mm diameter
Only labour chargesfor laying old RCC pipe
Painting two coats on new concrete surface paintig two coats including primer coat after filling the surface with syathnic enameled pain in all shades on new plastered / concrete surface as per drawing and technical specification clause 1701
Printing new letters and figures of any shade printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical specification Clause 1701 English / roman
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 Stone / boulder
Boulder Appron Providing and laying of boulder apron laid in wire crates with 4mm dia GI wire confirming ti IS 280 and IS 4826 in 100mm x 100mm (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications .clause 1301
Providing Latrite stone masanary in cm 1:6 for foundation and plinth including striking joints on the unexposed faces and watering complete. ( latrite stone six sides cut and thickness of morter joints be 12 mm max.)
Bill No. 4 Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 200 m stone (precast)
Guard Stone Providing and fixing Reinforced cement concrete M-15 grade Gaurd Stone of Size 20x20x75 cm including fixing in ground and white washing etc. complete
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with areas not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm - 3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M 20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level complete (as per MoRT&H specification No.801) (for area Less than 0.9 sqm). 7Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Traffic Signs 900 mm equilateral triangleProviding and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Traffic Signs 900x 600 mm RectangularProviding and Fixing of Retro Reflectorised Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Traffic Signs 600x 450 mm Rectangular Providing and Fixing of Retro Reflectorised Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Traffic Signs 600 mm circularProviding and Fixing of Retro Reflectorised Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
Providing and applying hot applied tharmoplastic reflective pavaement paint, marking paint for trafic lane strip 100 mm wide and 3mm tk. On road surface with 10% of binder and 60 % fillar materrial as per MORT and H specification including cleaning road surface with all dirt, dust and other foren materials demarcating of the site managing the traffic etc. complete with three years garantee
Supplying and fixing of molded shank raised pavement markers/ cat's eyes made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 type H and complying to specifications of category A of MORTH circular no RW/NH/33023/10-97 DO III Dt.11.06.1997.The height,width and length shall not exceed 50mm,100mm and 100 +/-2 mm with minium reflective area of 13 sqcm on each side and the slope to the base shall be 35 +/-5 degree The strength of detachment of the integrated cylindrical shanks( of diameter not less than 19+/-2 mm and height not ledd than 30+/-2 mm) from the body is to be a minium value of 500 kg.fixing will be by drilling holes on the road for the shanks to go inside without nails and using epoxy resin based adhesive as per manufactures recommendation and complete as directed by the engineer The contractor shall submit a two year warranty for satisfactory field performance ancluding stipulated retro-reflectance of the reflecting panel to the engineer
Road Delineators supplying and installation of delineators( roadway indicators Hazard markers object markers) 80 to 100 cm high above ground level painted black and white in 15 cm wide strips fitted with 80x100 rectangular or 75 mmdia circular reflectorised panels at the top burried or pressed into the ground and confirming to IRC 79 and the drawings
Providing and erecting W metal beam crash barrier comrrising of 3 mm tk corrugated sheet metal beam rail 70 cm above road / ground leval fixed on ISMC series channel vertical post 150x75x5 mm spaced 2 m c to c ,1.8 m high, 1.1 m below ground road level all steel parts and fitting to be galvanised by not dip process all fittings to conform to IS : 1367 and IS: 1364 metal beam rail to be fixed on the vartical post with a spacer of channel section 150x75x6 mm , 330 mm long complete as per clause 810 including excavation for crash barrier foundation 500x500x950 mm and concrete M20 in foundation block 350x350x950 mm etc complete.
Shifting of Eletric Line/ Teliphone Line Pole Removal of teliphone/ electric poles with wire including excavation and dismantaling of foundation concrete and lines under the supervision of concerned department disposal with all lifts and up to lead of 1000 m and stacking the serviceable material separately as per technical specification clause 202
Pipe line shifting shifting of water supply line distmentling of exis tng water supply line and providing new water supply iine of pvc pipe 90mm PVC Of 6 Kg.
Bill No. 1 Site Clearance, Dismantling and Earth Works
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. In area of Non thorny jungle
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. In area of thorny jungle
Cutting of trees, including cutting of trunks, branches and removal of stumps and roots, refilling compaction of back filling and stacking of serviceable material by manual means with all lifts asper Technical Specification clause 201 Lead upto 1000 m. Girth from 300 to 600 mm
Cutting of trees, including cutting of trunks, branches and removal of stumps and roots, refilling compaction of back filling and stacking of serviceable material by manual means with all lifts asper Technical Specification clause 201 Lead upto 1000 m. Girth from 600 to 900 mm
Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 mExcavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with all lifts upto 1.5 m & lead up to 1000 m, as per Technical Specification Clause 302.3
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross-sections as per Technical Specification Clause 302.3.5
Excavation in Hard Rock (requiring blasting) with disposal upto 1000 m Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical Specification Clause 302.3.5
Excavation for roadway in hard rock with controlled blasting by drilling blasting and breaking trimming of bottom and side slopes in accordance with requirements of lines grades and cross sectiond loading and disposal of cut rock with a lift upto 1.5 m and leads upto 1000 m as per Technical specification clause 302.3.5 (iii
Excavation in Hard Rock (blasting prohibited)Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause 302.3.5
Construction of Embankment with material obtained from Road way cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Construction of Embankment with material obtained from Borrw pit Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
Dismanteling Stone Masonary -Dismentaling of exisiting structure like culvert, bridges, retaining walls and other structure comprsing of masonary,cement concrete, wood work, steel work, including T & P and sacffolding whereever necessary, sorting the dismantled material etc. complete with all lifts and lead of 1000 mt as per technical Specification clause 202
Removing all types of Hume pipes and Stacking with a lead of 1000 m including earthwork and Dismentaling of masonary work as per technical specifications clause 202. 600mm to 900 mm Dia.
Bill No. 2 Pavement Works (GSB, WBM, Bituminous Works) and Cement Concrete Pavement Work
Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4.
Granular Sub-base with Well Graded Material- By mix in Place method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.grade I material
Water Bound Macadam GRADE II Sub-base/base Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
Tack Coat Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503. By Mechanical Means
Modified Penetration Macadam Construction of penetration macadam over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder and key aggregates and rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506 . 50 mm thick , using bitumen S-65 ( VG30)
20mm thick Open-Graded Premix Carpet using Bituminous with s-65 bitumen Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades followed by seal coat of either Type A or B, or C, as per Technical Specification Clause 508. (Excluding Sealcoat )
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A or B, or C, as per Technical Specification Clause 510 . using bitumen S-65 ( VG30)
Bill No. 3 Cross Drainage Structures (Culverts & Minor Bridges), Drains and Protection Works
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.(in soft soil ) up to 3.00 m depth by mechanical means
Earthwork in Excavation for foundation of structure upto 3 mt depth as per drawing and technical specification including setting out, construction of shoringand bracing, removal of stumps and other deleterious matter, dressing of side and bottom and backfilling with approved material etc. complete.(In Hard Rock) blasting prohibited
Providing concrete for plain concrete in open foundation complete as per drawing and technical specifications Clause 802,803,1202 &1203 for P C C Grade M-10 nominal mix 1:3:6
Providing concrete for plain concrete in open foundation complete as per drawing and technical specifications Clause 802,803,1202 &1203 for P C C Grade M-15 nominal mix (1:2.5:5)
Plain cement concrete in substructure complete as per drawing and technical specification.clause 802,804,805,806,807,1202, 1204 for height up to 5.0 m for PCC M-15 nominal mix 1:2.5:5 For substructure
Providing and laying reinforced cement concrete 1000 mm dia. RCC pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.
Providing and laying reinforced cement concrete 600 mm dia pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.
Providing weep holes in plain/reinforced concrete abutment,wing wall,return wall with 100 mm dia. Pvc pipe extending through the full width of the structures with slope of 1(v):20 (h) towards drawing face complete as drawing and technical specification c
filter media Providing and laying filter media with granular crushed aggregates asper specification to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete asper drawing and technical specification Clause 1204.3.8
Providing amd laying reinforced cement concrete pipes NP2 for culvarts on first class bedding of granular material in single row including providing fixing collers in cement morter 1:2 but excluding excavation , protction works , backfilling concrete and masonary works in head walls and parapets clause 1106 600 mm diameter
Only labour chargesfor laying old RCC pipe
Painting two coats on new concrete surface paintig two coats including primer coat after filling the surface with syathnic enameled pain in all shades on new plastered / concrete surface as per drawing and technical specification clause 1701
Printing new letters and figures of any shade printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical specification Clause 1701 English / roman
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 Stone / boulder
Boulder Appron Providing and laying of bolder apron laid in wire crates with 4mm dia GI wire confirming ti IS 280 and IS 4826 in 100mm x 100mm (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications .clause 1301
Providing Latrite stone masanary in cm 1:6 for foundation and plinth including striking joints on the unexposed faces and watering complete. ( latrite stone six sides cut and thickness of morter joints be 12 mm max.)
Bill No. 4 Traffic Signs, Markings and Road Appurtenances, Road Safety & Road Furniture
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 Kilometer Stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 200 m stone (precast)
Guard Stone Providing and fixing Reinforced cement concrete M-15 grade Gaurd Stone of Size 20x20x75 cm including fixing in ground and white washing etc. complete
Providing and fixing Retro Reflective MMGSY / PMGSY LOGO informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Two Plates of ACP (Aluminum Composite Panel), material specifications as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The Lower plate will be of 4mm ACP of 1100x300mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of Both the plates will be welded to a 75mm x75mmx 12swg Mild steel post at / Tube Centre and this post will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lower plate will be 1200mm from normal ground level. The spacing between the diamond shaped plate and Lower Plate is kept 150mm. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors.”All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY signage manual Fig.1 (A) and Fig.1 (B) and as directed by Engineer in-charge. A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
Providing and Fixing of Retro Reflectorised direction & place identification sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4 mm thick ACP sheet supported with Back support frame of 35x35x5mm mild steel angle with areas not exceeding 0.9 sqm. Supported in mild steel angle iron post 75x75x6mm - 3.5 mtr height ,firmly fixed to the grounf by means of properly designed foundation of M 20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level complete (as per MoRT&H specification No.801) (for area Less than 0.9 sqm). 7Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Providing and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting. 900 mm equilateral triangle
Traffic Signs 900x 600 mm Rectangular Providing and Fixing of Retro Reflectorised 900 x 600 mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Traffic Signs 600x 450 mm Rectangular Providing and Fixing of Retro Reflectorised Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
Traffic Signs 600 mm circularProviding and Fixing of Retro Reflectorised 900mm Cautionary sign boards made out of retro reflective sheeting of High Intensity prismatic grade conforming to IRC-67: 2012 & Type IV standards of ASTM D4956-09 specifications, fixed over 4mm thick ACP sheet supported with Back support frame of 25x25x3mm mild steel angle as approved , supported on a mild steel angle iron post 65 mm X 65 mm X 6 mm - 3.5 mtr height, firmly fixed to the ground by means of properly designed foundation with M20 grade cement concrete 45 cm X 45 cm X 60 cm , 60 cm below ground level as per approved drawing. Both border & background shall be retro reflective as per Type IV standards. 7 years Warranty for Retro Reflective Sheeting from the original sheeting manufacturer & a certified copy of three years outdoor exposure report from an independent test lab for the product offered shall be submitted by the contractor(Bottom of the board shall be at least 2.6 mtr. above ground level) Specification: IRC 67:2012. There shall be a stamp behind the ACP sheet carrying the name of the supplier, Name of sheeting Manufacturer, Type of retro reflective sheeting, Installation month & year, Warranty period for retro reflective sheeting.
MMGSY / PMGSY Citizen' s information Board- Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-20 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class A or Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2012. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 5 years & 7 years for Class A and Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16). The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 5 / 7 years for the Retro reflective sheeting for Class-A and Class-B respectively, from original manufacturer shall be submitted by contractor.
Providing and applying hot applied tharmoplastic reflective pavaement paint, marking paint for trafic lane strip 100 mm wide and 3mm tk. On road surface with 10% of binder and 60 % fillar materrial as per MORT and H specification including cleaning road surface with all dirt, dust and other foren materials demarcating of the site managing the traffic etc. complete with three years garantee
Supplying and fixing of molded shank raised pavement markers/ cat's eyes made of polycarbonate and ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering lens face and shall support a load of 16000 kg tested in accordance to ASTM D 4280 type H and complying to specifications of category A of MORTH circular no RW/NH/33023/10-97 DO III Dt.11.06.1997.The height,width and length shall not exceed 50mm,100mm and 100 +/-2 mm with minium reflective area of 13 sqcm on each side and the slope to the base shall be 35 +/-5 degree The strength of detachment of the integrated cylindrical shanks( of diameter not less than 19+/-2 mm and height not ledd than 30+/-2 mm) from the body is to be a minium value of 500 kg.fixing will be by drilling holes on the road for the shanks to go inside without nails and using epoxy resin based adhesive as per manufactures recommendation and complete as directed by the engineer The contractor shall submit a two year warranty for satisfactory field performance ancluding stipulated retro-reflectance of the reflecting panel to the engineer
Road Delineators supplying and installation of delineators( roadway indicators Hazard markers object markers) 80 to 100 cm high above ground level painted black and white in 15 cm wide strips fitted with 80x100 rectangular or 75 mmdia circular reflectorised panels at the top burried or pressed into the ground and confirming to IRC 79 and the drawings
Shifting of Eletric Line/ Teliphone Line Pole Removal of teliphone/ electric poles with wire including excavation and dismantaling of foundation concrete and lines under the supervision of concerned department disposal with all lifts and up to lead of 1000 m and stacking the serviceable material separately as per technical specification clause 202
Pipe line shifting shifting of water supply line distmentling of exis tng water supply line and providing new water supply iine of pvc pipe 90mm PVC Of 6 Kg.
RADHIKA CONSTRUCTIONS
M/S. MANGALMURTI CONSTRUCTION COMPANY
SIDDHIVINAYAK CONSTRUCTION Pro.Naresh Adhasani
SHRI GANESH INFRA
P K Parab
omtech associates
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .