Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.9 L+₹2.1 L (10.1%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹26.0 L+₹5.2 L (24.8%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹26.4 L+₹5.5 L (26.6%)Rejected-Finance KRISHNA SOCIETY OPP TODI XRAY AND DIAG CENTRE MAKUM ROAD TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹28.3 L+₹7.4 L (35.6%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
7 Jun 2024, 6:00 pmClosed
GE NAMS
GE NAMS AMRITSAR
REPAIR / MAINT OF SEWAGE PUMP, MOTOR AUTOMATION OF SEWAGE LIFTING PUMPS AND OTHER CONNECTED WKS AT NAMS
2024_MES_653430_1
GE NAMS-50/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE NAMS
CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
GE NAMS
₹60,000
16 Jul 2024
10 May 2024
14 Jun 2024
10 May 2024
7 Jun 2024
24 May 2024
Amount
Material and labour for dismantling / opening the burnt motor, rewinding the motor with super enamelled copper winding as per existing gauge including insulation material cotton tape, varnish, insulation paper, sleeves and dry and packing etc including replacing of bering, impeller and Mechanical oil seal and reassembling complete motor of capacity 15 HP to 20 HP complete all as specified and directed. NOTE : (a) The cost of copper winding wire of any size / gauge deemed to included in this job (b) The cost of tranportation such as vehicle, T & P and man power for taking out of faulty motor and lowering the same deemed to be included in this job (c) Old copper winding wire will be the property of contractor (d) Replacing of parts will be measured and paid seperately as supply only.
Description all as per item 1.00 above here in before but capacity 7.5 HP to 12.5 HP
Supply only in repalcement of bearing for submersible motor & pump for 15 HP to 20 HP complete all as specified and directed.
Supply only in repalcement of bearing for submersible motor & pump for 7.5 HP to 12.5 HP complete all as specified and directed.
Supply only in repalcement of S S impeller for 7.5 to 20 HP complete all as specified and directed.
Supply only in repalcement of mechanical oil seal for 15 to 20 HP submersible pump complete all as specified and directed.
Supply only in repalcement of mechanical oil seal for 7.5 to 12.50 HP submersible pump complete all as specified and directed.
Supply and fixing in replacement MCB 32 Amps four pole 240 Volts, 50Hz, rupturing capacity 10 kA, C curve , conforming to IS 8828 ; complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of MCCB 63 Amp, 4 Pole, 16 KA complete all as specified and directed by EIC.
Supply and fixing in replacement of MCCB 100 Amp, 4 Pole, 25 KA complete all as specified and directed by EIC.
Supply and fixing in replacement of MCCB 250 Amp, 4 Pole, 25 KA complete all as specified and directed by EIC.
Supply and fixing in replacement fan belt B 70 and suitable for 40 HP Compressor ; complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement fan belt B 52 and suitable for 20 HP Compressor ; complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of 3 pole power contactor 40 Amp, AC 3 phase, 415 Volt, with contact ( NO-1 + NC-1) complete all as specified and directed.
S & F in replacement of 3 pole power contactor 18 Amp , AC 3 phase, 415 Volt with contact ( NO-1 + NC-1) complete all as specified and directed.
S & F in replacement of 3 pole power contactor 25 Amp, AC 3 phase, 415 Volt, with contact ( NO-1 + NC-1) complete all as specified and directed.
S & F in replacement of thermal over load relay 12 to 18 Amp 415 Volt complete all as specified and direcetd.
S & F in replacement of thermal over load relay 28 to 40 Amp 415 Volt complete all as specified and direcetd.
S & F in replacement of thermal over load relay 17 to 25 Amp 415 Volt complete all as specified and direcetd.
S & F in replacement of electronic timer for star delta starter 415 volt timing range 0 sec to 30 sec complete all as specified and direcetd.
Material and labour in replacement of Single phase preventor SM 301 complete all as specified and directed.
Supply, laying and testing Ductile Iron Pressure Pipes with spigot & socket ends of 100 mm bore class K-7 centrifugally cast conforming to IS:8329/2000 blast furnace slag cement portland cement properties suitable for push-on jointing with inside surface cement mortar lining, with internal metallic zinc coating and external black bitumen coating, duly ISI marked complete laid in trenches or under the roads, with and including Tyton rubber gasket push-on joints as per required at site, including DI fittings required at site and dismantling & taking out the old unserviceable water supply pipe line any type from the trenches complete all as specified and as directed by Engineer-in-charge. Note :- (a) Excavation & other earth work shall be measured and paid separately under relevant items.
Supply, laying and testing Ductile Iron Pressure Pipes with spigot & socket ends of 80 mm bore class K-7 centrifugally cast conforming to IS:8329/2000 blast furnace slag cement portland cement properties suitable for push-on jointing with inside surface cement mortar lining, with internal metallic zinc coating and external black bitumen coating, duly ISI marked complete laid in trenches or under the roads, with and including Tyton rubber gasket push-on joints as per required at site, including DI fittings required at site and dismantling & taking out the old unserviceable water supply pipe line any type from the trenches complete all as specified and as directed by Engineer-in-charge. Note :- (a) Excavation & other earth work shall be measured and paid separately under relevant items.
Repair / rewinding of electric mono block motor 15 HP including disconnecting electric connection carefully and shifting to repair workshop and opening the electric motor rotar and stater. Rewinding the motor as per existing gauge of copper winding wire, varnish, insulation sleve, retopening of coil, supply and replacement of bearing -02 Nos and welding granting and polishing of shaft as per bearing size. Reassembling the motor and shift to site and fixing and testing on load.
Repair / rewinding of electric mono block motor 10 HP including disconnecting electric connection carefully and shifting to repair workshop and opening the electric motor rotar and stater. Rewinding the motor as per existing gauge of copper winding wire, varnish, insulation sleve, retopening of coil, supply and replacement of bearing -02 Nos and welding granting and polishing of shaft as per bearing size. Reassembling the motor and shift to site and fixing and testing on load.
Repair to water circulation pump 01 to 05 HP including disconnecting electrical connection carefully from site and shiftting to repair work shop and disconnecting / opening the motor, stater & rotter carefully and taking out burnt winding wire and rewinding the motor existing gauge winding wire, insulation sleeve, varnish and replacement of two No ball bearing , assembling after repair and shift to site and fitted and connection and testing on load complete all as specified and directed. NOTE for item S No-24,25,26 : (a) The cost of copper winding wire of any size / gauge deemed to included in this job (b) The cost of tranportation such as vehicle, T & P and man power for taking out of faulty motor and fixing at existing the same deemed to be included in this job (c) Old copper winding wire will be the property of contractor (d) Rate for replacing of parts is deemed to be included in this job.
Testing of treated water of STP from recognised lab of PPCB checking the level of BOD TSS, PH & O&G, NO2, HCL, CO and other parameters all as specified and directed. It will be done under SHO once in one month and result achived should meet GOI Guidelines on the subject. Failing which payment for the said duration penalty of RS 5000/- will be deducted (i.e from last testing to current testing). The site will be subjected to check by MES authority as well as by Stn HQ and all times STP would be odour free and water will be algae free complete all as specified and directed.
Repair to air copmressor of 20 HP deffusers coarse bubble / nozzles including opening cafefully and cleaning / repair/ replacement rotary turn lobe air blower with air filter, silencer, gauger, safety valves, drive bearing and bearing (Gear side) oil seal drive end long shaft and Short shaft, Piston and sleeves, Leap seal gear and bearing cover, gasket gear cover and welding grinding & polishing drive rotor shaft assembly as per bearing size, replacement the recommended oil grade and greasing and assembling and testing on load.
Repair to air copmressor of 40 HP deffusers coarse bubble / nozzles including opening cafefully and cleaning / repair/ replacement rotary turn lobe air blower with air filter, silences, gauger, safety valves, drive bearing and bearing (Gear side) oil seal drive end long shaft and Short shaft, Piston and sleeves, Leap seal gear and bearing cover, gasket gear cover and welding grinding & polishing drive rotor shaft assembly as per bearing size, replacement the recommended oil grade and greasing and assembling and testing on load.
Material & Labour for Repair and Rewinding of Electric induction motor 15 to 20 HP including disconnecting electrical connection carefully and shifting to workshop and opening the electric motor rotar & stater and Rewinding the motor as per existing gauge of copper winding wire, varnish, insulation sleve and reassembling the motor shift at site and connecting, testing on load ; complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Repair and Rewinding of Electric induction motor 40 HP including disconnecting electrical connection carefully and shifting to workshop and opening the electric motor rotar & stater and Rewinding the motor as per existing gauge of copper winding wire, varnish, insulation sleve and reassembling the motor shift at site and connecting, testing on load ; complete all as specified and directed by Engineer-in-Charge.
Supply and installation, testing and commissoining of NON- CLOG vertical submersible pump 510 LPM 20 MTR HEAD 7.5 HP with chrome steel impeller and cutter, non clog to pass 30 mm size particle incl with guide rail and lifting chain compl all as specified and directed by Engr - in - charge.
Supply and installation, testing and commissoining of NON- CLOG vertical submersible pump 510 LPM 20 MTR HEAD 12.5 HP with chrome steel impeller and cutter, non clog to pass 30 mm size particle incl with guide rail and lifting chain compl all as specified and directed by Engr - in - charge.
Supply and fix in replacement of MS pipe double flanged type not less than 4 mm thick heavy grade with all fittings laid in floor or fixed to wall and ceiling etc of sizes 100 mm dia complete all as specified and directed.
Supply only cast iron fittings for flanged or spigot socketed pipe such as tail piece connecting pieces bends tappers, tee pieces (Single or double branch) any type & angle/radious and straight connecting pieces suitable for bore upto 150 mm dia pipe complete all as specified and directed.
Supply and fix in replacement of CI butterfly valve heavy grade size 150 mm dia PN 1.6 complete all as specified and dircted.
Supply and fix in replacement of CI butterfly valve heavy grade size 100 mm dia PN 1.6 complete all as specified and dircted.
Supply and fix in replacement of CI butterfly valve heavy grade size 80 mm dia PN 1.6 complete all as specified and dircted.
Supply and mixing of poly electrolite (PE) Anionic 99 % complete all as specified and directed.
Supply and mixing poly Aluminium Chlorite (PAC) complete all as specified and directed.
Supply and chlorination of sodium hydrochloride solution having free chlorine from 7% to 10 % in and including 60 Ltr PVC Canes/ drum complete all as specified and directed.
Supply and fix in replacement of submercible flat 4 Sqmm, 3 core copper cable, 1100 volts conforming IS 694:1990
M & L for cleaning of sewage collection sump/ Treated water tank/ Tube settler tank of capacity 25000 Gallon : (i) Dewatering with submercible / sludge pump which empty the sump / tank upto base level. (ii) Removing sludge from sump wall and bottom sump have to be removed with the help of special sludge pump and remaining dirt which may have hidden in rough slots of the bottom to be removed mannualy with brush (iii) After cleaning the sump apply bleaching powder for disinfection of sump (Sewage collection sump).
Description all as per item 44.00 here in before but capacity 50000 Gallons.
Removal of dry sewage sludge from dry bed and and disposed off properly outside the MD land upto the entire satisfaction of engineer in charge complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement of terminal block 4 way / 6 way as required and directed, barrier type, panel mountable with current carrying capacity of upto 25A, suitable for voltage of 415 , complete with screws and other accessories complete all as specified and directed.
Starting up aerobic process from airation tanks (set of two), running of blower 24 hrs a day basis add free cow dung water, DAP powder, urea powder add aerote the contents of the aerotion tank for 2 checking of MLSS level mainting up to prescribed level of PPCB complete all as specified and directed.
M & L for painting of sewage pipe line at STP 1.1 MLD, STP 2.5 MLD & STP 0.87 MLD complete all as specified and directed.
Excavation trenches not exc 1.5 m wide and not exc 1.5 mtr deep and getting out in any type of soil complete all as specified and directed .
Returning filling including spreading levelling, watering and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus excavated soil to a distance not exc 50 M and and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
Supply and fixing in replacement of CI sluice valve heavy grade of size 150 mm dia PN 1.6 complete all as specified and directed.
Supply and fixing in replacement of CI sluice valve heavy grade of size 100 mm dia PN 1.6 complete all as specified and directed.
S & F in replacement CI non return valve 150 mm bore heavy duty grade PN 1.6 complete all as specified and directed by Engr -in- Charge.
S & F in replacemnt CI non return valve 100 mm bore heavy duty grade PN 1.6 complete all as specified and directed by Engr-in- Charge.
To attend the Elect complaints of sewage installation replacing burnt lugs of cable, to check auto star delta starter, voltmeter, Amp meter in pump panel change over switch and make functional if minor repair involves to above equipments complete all as specified and directed.
Material and labour for plastic media MBBR (moving bed bio reactor) complete all as specified and directed by Engr -in-charge.
Supply, Install, Testing and Commissioning in replacement of factory made outdoor type dust and vermin proof(IP 54 protection) feeder Pillar LT Panel board cubicle double door hinged type of suitable size 415V AC, 50Hz, fabricated of CRCA sheet 3.15 mm thick machine pressed and angle iron frame 50 mm X 50 mm X 6 mm grouted in PCC, Panel bottom 40 cm above Ground level, powder coated in Seven Tank process inside and outside complete including 4 Pole aluminum Bus Bar of suitable size mounted on porcelain insulator, All accessories prewired with suitable size copper wire with stand high temperature, concealed hinged door with Sliding door bolt door locking arrangement and enclosed in chamber made out of 2mm sheet thick GP/ CRCA sheet machine pressed and connection from incoming and outgoing electric cable with suitable size thimbles/lugs cable gland with open able shutters on both side of comprising of following :- Note : Old unsv LT panel will be deposited to be MES yard by the contractor without any extra cost paid to the contractor.
(a) Incommer MCCB 250 Amp , Four Pole, Thermal based release with adjustable O/L, Adjustable S/C setting class II front face, 36KA rupturing capacity, Ics =100% Icu, isolation with positive break indication, standard extended rotary handle, spreaders, phase barrier- 1 No (b) Metering Section- Digital Voltmeter showing 0-500V with duly prewired with copper cable of suitalbe size with 3 x 2A SP MCB, 3 x indicators RYB-01 No (c) Metering Section- Digital Ammeter showing 0-300 Amp with duly prewired with copper cable of suitalbe size with 3 x 2A SP MCB, 3 x indicators RYB-01 No (d) Insulated Busbar of Aluminium of 300 A Capacity for 3 phase, fixed on Insulators, Busbar shall be PVC Sleeved with red / Yellow/ Blue Colour, Busbar Support shall be of SMC/DMC - 1 set. (e) Stop push button 12 Nos (f) (e) Outgoing MCB TP 40 Amp, 10 KA breaking capacity -05 Nos (g) Outgoing MCB TP 32 Amp, 10 KA Breaking Capacity-06 nos. (h) MCB TP 63 Amp, 25 KA breaking Capacity-02 Nos.
(j) MCCB Auxilary contacts 1 No (k) Trip Alarm Contacts (l) Shunt Trip 220 V AC (m) Emergency stop push button (n) 06 A SP 10 KA MCB - FOR CONTROL "C" CURVE (o) Star delta Timer -01 No, Contactor MNX-80- 06 Nos, Overload Relay 30 t0 50 Amp - 02 No. (p) Star delta Timer -01 No, Contactor MNX-40- 04 Nos, Overload Relay 19 t0 25 Amp - 04 No.(q) Star delta Timer -01 No, Contactor MNX-25- 06 Nos, Overload Relay 09 t0 14 Amp - 06 No. (r) 1 No+ 1 Nc block =16 Nos (s) Power contractor MNX -95 Amp , Single phase Preventor -01 Nos
Mahajan Builder
M/s MAHAJAN CONSTRUCTION CO.
ss enterprises
CHINAR ENGINEERS AND BUULDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .