Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.4 LAccepted-AOC 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹53.7 L+₹3.9 L (7.75%)Rejected-Finance H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L2 | Rejected-Finance L2 for Rejected |
Tender Value
Refer Docs
EMD Value
₹1.0 L
Closing Date
16 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO CWE SGNR TOKEN-12 OF 2023-24 PROVN OF THREE PHASE CONNECTION WITH ALLIED SERVICES AS PER NEW MAP PROVISION IN OFFICERS MD ACCN OF BHAGAT ENCLAVE AT SRIGANGANAGAR MIL STATION
2023_MES_596758_1
CA NO CWE SGNR T-12 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE SRI GANGANAGAR
AS PER NIT
10 documents required · 10 mandatory
₹1,000
GE SRI GANGANAGAR
₹1.0 L
Yes
20 Jul 2023
19 May 2023
19 Jun 2023
19 May 2023
16 Jun 2023
2 Jun 2023
Amount
Supply and fix industrial socket metal clad plug and socket with MCBs single pole 20 Amp complete all as specified and directed by Engineer - in - Charge.
S & F in replacement of sub-main wiring with PVC insulated and un-sheathed 4 x 6.00 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in and including PVC "medium quality" conduit as per size required including 2 x 6 Sqmm (Nominal area) copper cable as earth contiunity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. Note :- Four length of 6 Sqmm cable and two length of 6 Sqmm earth cable along with PVC conduit will be measured as one running length
M&L for point wiring for industrial socket metal clad plug and socket with MCBs single pole 20 AMP with 4.0 Sqmm PVC copper conductor FRLSH and 4.0 Sqmm PVC insulated copper conductor as earth contiuity, 20mm dia medium duty ISI marked, complete including cutting, chasing the surface and then making good the same in CM (1:3) complete all as specified and directed by Engineer-in-Charge, Note:- This Item is for AC.
M&L for point wiring for invertor with 2.5 Sqmm (nominal area) PVC insulated, unsheathed multi standard copper conductor cable FRLSH in and including concealed PVC conduct 20mm dia medium duty ISI marked, steel terminal sunken boxes 2mm thickness and 60mm deep and 3mm thick phenolic laminated sheet top cover for sunken boxes flush to surface for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 2.5 Sqmm copper conductor cable FRLSH as earth Continuity connected to common earth duly complete including cutting, chasing the surface and then making good the same in CM (1:3) complete all as specified and directed by Engineer-in-Charge Note :- This item is for Invertor.
S&F Switch socket combination 6 Pin, 15/16 Amps flush type complete all as specified and directed by engineer-in-charge. Note:- This item is for inverter
M&L for extra wiring for inverter socket outgoing to DB with 2.5 Sqmm single core, FRLSH PVC (usung colour coding as directed) insulated multistandard cooper conducton drawn through existing conduct (conduct for point wiring already catered in item No 04) including making connection to DB and inverter socket complete all as specified and directed by engineer-in-charge.
S &F plug top 15/16 Amp 3 pin good quality suitable for 240V, AC supply for inverter socket complete all as specified and directed by engineer-in-charge.
S & F in replacement sheet metal enclosure for double door DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted TP & N 6 ways, 415 Volts, ISI marked 200 Amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S & F in replacement sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted TP & N 4 ways, 415 Volts, ISI marked 200 Amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge. Make:- Havells/ Legrand/ Siemens
S&F in replacement Sheet metal enclouser for doble door Vertical DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mouting VTPN 4 Way 415 Volt ISI marked 250Amps busbar stove enameled dust and vermin proof,IP:43 protection suitable for incorporation FP MCCB(V-Tech) N3 Frame upto 250A ,Isolators and including give connection with wire and cable etc complete all as specified and directedby engineer -in-charge
S&F in replacement MCCB TP & N 100 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge.
S&F in replacement MCB TP&N 63 Amps with breaking capcity 10kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge.
S & F in replacement MCB ‘B’ series type suitable for 415 volts, AC supply 40 Amps, triple pole (TP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacement MCB ‘B’ series type suitable for 415 volts, AC supply 40 Amps, triple pole and (TPN) neutral with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole (SP) with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI wire earth lead 4 mm dia by means of bolts,nuts and washers of GI and protection by provision of GI light grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg /Sqm) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI medium grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point including testing on completion and taking out unserviceable earthing with all acessories complete all as specified and directed by Engr -In - Charge
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earth strip 32 x 6 mm thick fixed by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strips connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia and watering pipe 20mm dia GI medium grade with plug socket and above ground level including earthwork, PCC chamber in PCC (1:2:4) type B-1 using 20mm stone aggregate, cast iron cover, wire mesh etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes:- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) Cost of earth lead GI strip connecting upto pump,Gen set,LT panel and DBs earth connection or earthing test point is included in this item (7.50RM). (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables and getting out complete all as specified and directed by Engineer - in - Charge
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engineer - in - Charge
Removal of Excavated material n exceeding 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed by Engineer - in - Charge.
M & L for sand cushioning with dry and clean locally available sand for underground cable 8cm before laying cable and 15 cm after laying cable and punned to 18 cm after laying of cable complete all as specified and directed by Engineer-in-Charge (Note: Pressed thickness shall be considered for payment purpose)
Supply and laying standard size bricks sub class 'B' complete all as specified and directed by Engineer - in - Charge
Supply, laying, jointing, testing and commissioning in replacement of 35 Sqmm x 3.5 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge.
Supply, laying, jointing, commissioning and testing in replacement of 25 Sqmm x4 core XLPE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/laid under roads/paths/drain/culverts or passing through pipes complete all as specified and directed by engineer in charge.
Supply and fixing 3 pin telephone socket RJ 11 with metal flush box having holes for 20 mm conduit entry for telephone connection complete all as specified and directed by Engineer-in- Charge.
S & F Rigid non-metallic PVC conduit 20 mm dia inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer - in - Charge.
Supply and laying in replacement GI pipe 50 mm light grade for cable protection in walls trenches or any situation including clamp nut bolt etc all as directd and specified by Engineer-in-Charge.
Supply, installation, commissioning and testing in replacement factory made LT panel Board (main control board) of minimum size (0.9 m x 0.9 m x 0.25 m ) fixed on/inside wall (front side openable glass double door including locking arrangements and handle), dust proof, vermin proof made out of CRCA sheet 2 mm thick duly powder coated, Suitable size for fixing electronic energy meter-04 Nos and VTPN DB box with incoming cable and out going sub-main wiring and internal wiring with & including single core, PVC copper conductor unsheathed wire multistanded 4 sqmm and with proper spacing including provision of rubber beading and mild steel cable glands and lugs, provision of air fins for ventilation, complete including all connections incoming / out going, complete all as directed by Engineer-in-charge.
UNITED ENGINEERING CORPORATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .