Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.2 CrAccepted-AOC GWJWNPURI WARD NO 4 CHIRANG P O CHAPAGURI PS DALIGAON DISTRICT CHIRANG PIN 783373 | KOKRAJHAR | ASSAM | 783373 | ₹75.2 Cr | L1 | Accepted-AOC Awarded |
| 2 | L1₹75.2 CrRejected-AOC BHASKAR NAGAR BYE LANE NO 2 GUWAHATI 21 | SOUTH SALMARA MANCACHAR | ASSAM | 783127 | ₹75.2 Cr | L1 | Rejected-AOC Rejected |
| 3 | L2₹79.7 CrRejected-AOC 14 BILASIPARA P O P S BILASIPARA DIST DHUBRI ASSAM PIN 783348 | DHUBRI | ASSAM | 783348 | ₹79.7 Cr | L2 | Rejected-AOC Rejected |
| 4 | Not Admitted-Fee/PreQual/Technical 8TH FLOOR SETHI TRUST BUILDING UNIT II BHANGAGARH G S ROAD GUWAHATI 781005 | KAMRUP METRO | ASSAM | 781005 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹83.5 Cr
EMD Value
₹1.7 Cr
Closing Date
29 Jan 2024, 2:00 pmClosed
Chief Engineer (Roads), PWRD, Assam
O/o the Chief Engineer Roads, PWRD, Assam, Chandmari, Guwahati, 781003
ASOM_MALA_2.0_23_24_04 Improvement and Upgradation of Road from Barama to Tamulpur from Ch. 0.000 km (Tamulpur) to Ch. 26.145 km (Barama) under Asom Mala 2.0 for the year 2023-24.
2024_PWD_35279_4
CE/DEV/TB/737/2023-24/01
Open Tender
Civil Works
540 days
Baksa
Please refer Tender documents.
4 documents required · 4 mandatory
₹30,000
₹1.7 Cr
Yes
O/o the Chief Engineer Roads, PWRD, Assam
1 Apr 2024
8 Jan 2024
29 Jan 2024
8 Jan 2024
29 Jan 2024
22 Jan 2024
8 Jan 2024 - 20 Jan 2024
20 Jan 2024
Amount
Clearing and Grubbing Road Land : Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. (i) By Manual Means, (a) In area of non thorny jungle
Dismantling of flexible pavements and disposal of dismantled materials upto a lead of 100 m, stacking serviceable and unserviceable materials separately as per Technical Specification Clause 202. By Mechanical Means Bituminous Courses
Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 m Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, inaccordance with requirements of lines, grades and cross-sections, and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3
Removal of Unsuitable Soil with Disposal upto 1000 m Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and comp g actin to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (i) Private Land
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i) Private Land
Granular Sub-Base with Coarse Graded Material (Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC,and compacting with vibratory roller to achieve the desired density,complete as per cl. 401.
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sb-base/base course on well prepared surface and compacting with vibratory roller to achieve the desired density (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant
Surface Dressing using Bituminous (Penetrations grade / modified bitumen) Binder Providing and laying surface dressing as wearing course consisting of a layer of bituminous binder laid on the prepared surface, followed by a cover of crushed stone aggregates of specified size and rolling with three wheel 80-100 kN static roller including cleaning the road surface as per Technical Specification Clause 507 B) By Mechanical Means Case – I: Nominal chipping size 13.2 mm ii) Bitumen (S-65)
Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix and filler transporting the hot miox to work site,laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no. 507. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (a) With hydrated lime/cement as filler (refer table 500-9 of MoSRT&H specification), (A) with 60/70 or VG-30 grade bitumen. (ii) for GradingII(19 mm nominal size)
Bituminous Concrete: Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant) (Including cost of testing of materials at site and laboratory as directed by the deptt.) With 60/70 or VG-30 grade bitumen for Grading II (13 mm nominal size).
Tack Coat iii)Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
Providing and laying interlocking concrete block pavement with M40 grade gradeof concrete blocks having thickness 80mm as per technical specification clause 1504 complete including carriage. Including Edge block/ Edge restraints
Supplying, filling and laying in loose with Geo-textile bags of Type-A (1.30m x 0.70m) made of Geo textile non woven fabric sheets of 400 GSM manufactured from polyster/ polypropylene conforming to relevant ISO standard filled with specified sand/ silt from flood plain or adjacent char within a distance of 90 m of the work site including excavation, filling Geo bags with sand weighing 126.00 kg after filling, stitching the mouth of the filled bags with polypropylene or polyster complete as per technical specifications and as directed. b) Without Boat
Supply, Stitching and Laying of Non wooven Geo textile Fabric sheet of 400 gsm
Providing and fixing of road stud 100 x 100 mm die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling holes 30 mm upto a depth of 600 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:873 (Part 4) 1973.
'Traffic Signs Retro-reflectorised Traffic Signs 'Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 600mm equilateral triangle
Traffic Signs Retro-reflectorised Traffic Signs 'Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 '600mm circular
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
Bridge Work Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I Ordinary soil, Upto 3 m depth
Providing and constructing one span service road to reach island location from one pier location to another pier location
Providing and constructing temporary island for construction of pile foundation with depth of water upto 4.0m complete as per technical specification.
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999) (Pile diameter-1000 mm)
Levelling course for Pile cap
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. D RCC Grade M35, (ii) Using Batching Plant, Transit Mixer and Concrete Pump
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)
Plain/Reinforced cement concrete, in sub-structure complete as per drawing and technical specification and steel shuttering formwork. II) With plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 b Height 5m to 10m, Case II With Batching Plant, Transit Mixer and Concrete Pump, H) RCC Grade M35
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal Panther steel/ Shyam steel or equivalent)
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification A) Granular material
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming centimetre to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
Furnishing and Placing Reinforced/Prestressed cement concrete in super?structure as per drawing and Technical Specification’ including steel shuttering formwork. II) With plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. Case II Using Batching Plant, Transit Mixer and Concrete Pump, (ii) For T-beam & slab, b) Height 5m to 10m, D) RCC/PSC Grade M35
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
Drainage Spouts complete as per drawing and Technical specification
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation).
P.C.C. M 15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specifications Clauses 800 and 1211 A With crushed stone, I Nominal mix (1:2.5:5)
Reinforced Cement Concrete M 25 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211 A With crushed stone,
Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
RCC Slab culvert Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I Ordinary soil, Upto 3 m depth
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser ( Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999) (Pile diameter-1000 mm)Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent ), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser ( Masterplast ACPL or equivalent) conforming to IS-9103-1999) (Pile diameter-1000 mm)
Levelling course for Pile cap
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification including providing plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. D RCC Grade M35, (ii) Using Batching Plant, Transit Mixer and Concrete Pump
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)
Plain/Reinforced cement concrete, in sub-structure complete as per drawing and technical specification and steel shuttering formwork. II) With plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 b Height 5m to 10m, Case II With Batching Plant, Transit Mixer and Concrete Pump, G) RCC Grade M30
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal Panther steel/ Shyam steel or equivalent)
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification A) Granular material
Furnishing and Placing Reinforced/Prestressed cement concrete in super?structure as per drawing and Technical Specification’ including steel shuttering formwork. II) With plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. Case II Using Batching Plant, Transit Mixer and Concrete Pump, (ii) For T-beam & slab, b) Height 5m to 10m, D) RCC/PSC Grade M35
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
Drainage Spouts complete as per drawing and Technical specification
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation).
P.C.C. M 15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specifications Clauses 800 and 1211 A With crushed stone, I Nominal mix (1:2.5:5)
Reinforced Cement Concrete M 25 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211 A With crushed stone,
Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I Ordinary soil, Upto 3 m depth
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. II) With plasticiser (Masterplast PL-1/SPL-2 & 2100 or equivalent), air-entraining and water-reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 E) RCC Grade M25, Case II With Batching Plant, Transit Mixer and Concrete Pump
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)
Plain/Reinforced cement concrete, in sub-structure complete as per drawing and technical specification and steel shuttering formwork P) With plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 F RCC Grade M25, a Height upto 5m, Case II With Batching Plant, Transit Mixer and Concrete Pump
Reinforcement in Sub-structure: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in sub-structure complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal Panther steel/Shyam steel or equivalent)
Furnishing and Placing Reinforced/ Prestressed cement concrete in super?structure as per drawing and Technical Specification’ including steel shuttering formwork. II With plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. B RCC Grade M25, Case II Using Batching Plant, Transit Mixer and Concrete Pump, (i) For solid slab super-structure
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal Panther steel/ Shyam steel or equivalent)
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.
Drainage Spouts complete as per drawing and Technical specification.
Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
P.C.C. M 15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specifications Clauses 800 and 1211 A With crushed stone, I Nominal mix (1:2.5:5)
Reinforced Cement Concrete M 25 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211 A With crushed stone,
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification A Granular material
RCC Single cell Box Culvert Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I Ordinary soil, Upto 3 m depth
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. II) With plasticiser (Masterplast PL-1/SPL-2 & 2100 or equivalent), air-entraining and water-reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 E) RCC Grade M25, Case II With Batching Plant, Transit Mixer and Concrete Pump
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)
Plain/Reinforced cement concrete, in sub-structure complete as per drawing and technical specification and steel shuttering formwork P) With plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser(Masterplast ACPL or equivalent) conforming to IS-9103-1999 F RCC Grade M25, a Height upto 5m, Case II With Batching Plant, Transit Mixer and Concrete Pump
Reinforcement in Sub-structure: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in sub-structure complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal Panther steel/Shyam steel or equivalent)
Furnishing and Placing Reinforced/ Prestressed cement concrete in super?structure as per drawing and Technical Specification’ including steel shuttering formwork. II With plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. B RCC Grade M25, Case II Using Batching Plant, Transit Mixer and Concrete Pump, (i) For solid slab super-structure
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal Panther steel/ Shyam steel or equivalent)
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.
Drainage Spouts complete as per drawing and Technical specification.
Construction of precast RCC railing of M30 Grade, aggregate size not exceeding 12 mm, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequat space between vertical posts for expansion, complete as per approved drawings and technical specifications.
P.C.C. M 15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specifications Clauses 800 and 1211 A With crushed stone, I Nominal mix (1:2.5:5)
Reinforced Cement Concrete M 25 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211 A With crushed stone,
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification A Granular material
RCC Cover Drain Dismantling of Cement Concrete Pavement (Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000metres, stacking serviceable materials and unserviceable materials separately.)
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. I) Ordinary soil, (a) Without dewatering, (i) upto 3 m depth
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. II) With plasticiser (Masterplast PL-1/SPL-2 & 2100 or equivalent), air-entraining and water-reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 E) RCC Grade M25, Case II With Batching Plant, Transit Mixer and Concrete Pump
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal Panther steel/Shyam steel or equivalent)
Plain/Reinforced cement concrete, in sub-structure complete as per drawing and technical specification and steel shuttering formwork II Without plasticiser F RCC Grade M25, a Height upto 5m, Case II With Batching Plant, Transit Mixer and Concrete Pump
Reinforcement in Sub-structure: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in sub-structure complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal Panther steel/Shyam steel or equivalent)
Furnishing and Placing Reinforced/ Prestressed cement concrete in super?structure as per drawing and Technical Specification including steel shuttering formwork. II With plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. B RCC Grade M25, Case II Using Batching Plant, Transit Mixer and Concrete Pump, (i) For solid slab super-structure
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal Panther steel/ Shyam steel or equivalent)
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification A Granular material
RCC load bearing Drain Dismantling of Cement Concrete Pavement (Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000metres, stacking serviceable materials and unserviceable materials separately.)
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. I) Ordinary soil, (a) Without dewatering, (i) upto 3 m depth
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. II) With plasticiser (Masterplast PL-1/SPL-2 & 2100 or equivalent), air-entraining and water-reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999 E) RCC Grade M25, Case II With Batching Plant, Transit Mixer and Concrete Pump
Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal Panther steel/Shyam steel or equivalent)
Plain/Reinforced cement concrete, in sub-structure complete as per drawing and technical specification and steel shuttering formwork II Without plasticiser F RCC Grade M25, a Height upto 5m, Case II With Batching Plant, Transit Mixer and Concrete Pump
Reinforcement in Sub-structure: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in sub-structure complete as per drawing and technical specifications (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal Panther steel/Shyam steel or equivalent)
Furnishing and Placing Reinforced/ Prestressed cement concrete in super?structure as per drawing and Technical Specification including steel shuttering formwork. II With plasticiser (Masterplast PL-1/SPL-2 or equivalent), air entraining and water reducing plasticiser (Masterplast PAE or equivalent) and accelerating plasticiser (Masterplast ACPL or equivalent) conforming to IS-9103-1999. B RCC Grade M25, Case II Using Batching Plant, Transit Mixer and Concrete Pump, (i) For solid slab super-structure
Reinforcement in Super Structure: Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications. (a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal Panther steel/ Shyam steel or equivalent)
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification A Granular material
RRM Retaining wall for Drain Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Stone masonry work: Uncoursed rubble masonry work in all retaining wall, wing wall, abutement etc. in cement mortar 1;6 withoutside face stone roughly hammer dressed and inside (earthen side) undressed as per drawing and technical sopecifications including racking out joints and curing , supplying and carriage of stone as directed.
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification.
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 i)Granular material
Gantry Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. i)Ordinary soil Upto 3m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803,1202 & 1203 A.With crushed stone iii) PCC grade M20
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802,803,1202 & 1203 A.With crushed stone iv) RCC grade M20
Providing retro reflective sign board of high intensity grade reflective sheeting conforming to ASTMD4956 BIII specifications having approved pattern over its entire surface bonded on to 2mm thick aluminium sheeting, the entire face of the sign shall be covered & bounded with yellow/white/red/blue high intensity grade with distinctive node pattern on front side with heat lamp vacuum applicator machine only.
Reinforcement in Foundation: Supplying , fitting an placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing an technical specications TMT-IS 1786(Fe-500 D) primary producer (TATA/SAIL/Esser Steel/Jindal panther steel/Shyam steel or equivalent)
Providing and erecting overhead signs of anti-corrosive steel (all the steel work must be TATA/SAIL/Any other approved brand) tubular frame structure for retro reflective signage boards made of high intensity grade encapsulated lens type retro reflective sheeting conforming to ASTMD4956 type B III specifications and having approved pattern over its entire surface bonded on to 2point 00mm thick aluminium sheet with back supporting angle iron frame of 35x35x4mm angle iron duly riveted with solid MS&Aluminum rivets. The entire face of the signs shall be covered and bounded with yellow/white/red/blue high intensity encapsulated lens reflective sheeting with distinctive hoed pattern on front side (no plain surface) with heat lamp vacuum applicator machine only. The yellow/white/red/blue portion of the board shall be screen printed on the high intensity shed base including fixing the board on portal/support/wall/dowel rod etc., with contractors clamps /cleats/bolts/rivets/wells including all contractors materials, labour, tools, lead & lifts etc. complete and all other incidental charges necessary for succesful completion of work as per specifications and as directed.
Paintig Works on Exsisting Bridge Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
Junction Improvement Granular Sub-Base with Coarse Graded Material (Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC,and compacting with vibratory roller to achieve the desired density,complete as per cl. 401.
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sb-base/base course on well prepared surface and compacting with vibratory roller to achieve the desired density (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant
Prime Coat ii) Medium porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
5.2 Tack Coat i)Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503
Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix and filler transporting the hot miox to work site,laying with a hydrostatic paver finisher with sensor control to the reqd. grade, lavel and alignment,rolling with smooth wheeled,vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no. 507. complete in all respect. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) (a) With hydrated lime/cement as filler (refer table 500-9 of MoSRT&H specification), (A) with 60/70 or VG-30 grade bitumen. (ii) for GradingII(19 mm nominal size)
Bituminous Concrete: Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the reqd. grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoSRT&H cl. no.509. complete in all respects. (including carriage of mixed materials up to 10.0 Km initial lead from mixing plant )( Including cost of testing of materials at site and laboratory as directed by the deptt.) I With hydrated lime/cement as filler (refer table 500-9 of MoSRT&H specification), A With 60/70 or VG-30 grade bitumen, (i) for Grading I (19 mm nominal size)
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
Providing reflective pavement markers with Micro prismatic lenses in both directions having thermoplastic body adhering to the specification and guidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance.
RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and as directed. (b) 15 cm dia. RCC guard post with reinforcement of 4nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c.
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 600mm equilateral triangle
Painting lines, dashes, arrows, etc. on roads in two coats on new work with sqm 85.60 ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702
Electrical shifting
water supply pipeline shifting
ANUPAM NIRMAN PVT. LTD.
SHREE GAUTAM CONSTRUCTION CO. LTD.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid