Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.7 LAccepted-AOC COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹92.7 L+₹4.7 L (5.30%)Rejected-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L2 | Rejected-Finance Other than being lowest | |
| 3 | L3₹94.4 L+₹6.4 L (7.27%)Rejected-Finance | L3 | Rejected-Finance Other than being lowest | |
| 4 | L4₹94.6 L+₹6.6 L (7.47%)Rejected-Finance COLABA MUMBAI | L4 | Rejected-Finance Other than being lowest |
Tender Value
₹83.9 L
EMD Value
₹1.5 L
Closing Date
18 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REP ROUTINE MAINT OF 26 NOS ELECTRIC LIFTS (MAKE ESCON )( 06 PS08 PS13 PSGOODS LIFT) OF G 5 G 14 STOREY BLDG AND M O OF ELECTRIC LIFTS ( ANY MAKE AND CAPACITY) IN G 14 STOREY BLDG IN BLDG R 11 R 22 R 25 MAKAR KUMBHA F5 F6 R4 R5 R7 R9 R10 R15 R
2021_MES_481906_1
8255/CWE(NW)MUMBAI/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (NW) Navy Nagar
Class C
8 documents required · 8 mandatory
₹1,000
Yes
GE (NW) Navy Nagar
₹1.5 L
Yes
10 Dec 2021
14 Oct 2021
20 Nov 2021
14 Oct 2021
18 Nov 2021
6 Nov 2021
14 Oct 2021 - 5 Nov 2021
60 days
Amount
Part I Repairs/maintenance of lifts including carrying out daily check and periodical services of fully automatic electrical lift with power operated door simplex, collective control system with repair/maintenance of unserviceable damage parts such as bearings bushes all type of shoes headers, hangers, car door, door locks, control cards, connector/links, welding of crack/broken MS parts, Repairs/maintenance of unserviceable damage of door safety edge and or sensor mechanical safety lock, magnetic lock or contact, car position indicator, door sill, car door sill necessary wiring hall push button assembly,Landing Operating Panel of any Size and capacity including all connected Accessories, complete with illuminated push button & direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for luminating of push button of each floors and cutting wall making good distrubed surface with masnary work to make with existing surface & cable as per requirement or safe operation of lifts minor repair to cabin, cabin light, fan etc ensure safety and smooth functioning of lift and disconnecting and repairs/maintenance of unserviceable/worn out parts such as warm wheel, warm shaft bushes, thrust bearing and pedestal bearing and necessary packing including overhaling, cleaning alignment of gear box assembly and after Repairs/replacement of wornout parts re-assembley and fixing with existing machine with proper alignment complete maintanance of car top, binding of loose wire at control panel and rust painting at car top and door and allied parts with testing as directed by Engineer-in-Charge for the following lifts :- Note : - Two mechanics shall be available round the clock at lift complaint cell for safe & smooth functioning of the lift and to carry-out rescue operation.
06 Ps Lift (408 Kg)(G+5 Storey) in bldg No Asha-2(N) , Asha-4(N), (Total 02 Nos of Lift)
8 Ps (544 Kg) capacity in bldg(G+14) R- 6,R-8, R-14, R-23, R-24, R-26 (Total 06 Nos lift).
13 Ps lifts (884 Kgs ) capacity in bldg(G+14) R- 8, R-18, R-19,R-29, R-31, Mesh (Total 06 Nos lift).
Goods Lift 29 Ps ( 2000 Kgs) capacity in Bldg ( G+14) R- 4, R-5, R-6, R-07, R-12, R-13, R-14,R-15, R-23, R-24, R-26, R-27( Total 12 Nos lift)
Note : - (i) The Contractor has to carry out the AMC of the Lifts through OEM only (ii) The AMC should cover any/all parts of Lifts if its function found defective the same should be repaired or replaced by the OEM as per the timeline covered under norms. (iii) One mechanic shall be available round the clock at lift complaint cell for safe & smooth functioning of the lift. (iv) Rewinding of motor if required will be done by the contractor and no extra cost will be given by the department. (v) The detailed lift mechanics of the firm shall report to the JE Concerned at the Lift complaint cell for receiving the complaints at round the clock daily including sunday and holiday. (vi) The detailed lift mechanics shall sign ( Their shift wise) in the attendence register kept with lift cell. (vii) Cost of minor spare parts / routine material required for above mentioned maintenance is deemed to be included in the quoted rate except items mentioned here-in-after. No additional cost of spares is admissible for the above maintenance. Decision of the Accepting Officer shall be final & binding regarding minor spares/ routine material (viii) Monthly schedule for proper maintenance of lift and necessary documentation including all spare parts required to be replaced during the period shall be as directed by Engineer-in-Charge. (ix) All minor spare parts and parts required for repair / replacement for maintenance of lifts to be replaced during AMC at no extra payment. (x) Bidders are to submit license from Govt. of maharashtra for maintenace & erection of lifts issued by chief electrical inspector.
Part II Disconnecting and taking out unserviceable COP assembly, Supply and fix new Panel assembly complete with illuminated push button for floor position, alarm, non stop door open, door close, cabin fan, cabin light stop, attend out key etc with direction indicator with LED display with CPI card of stainless steel face plate in and including necessary wiring for illuminating push button complete all as specified and directed by Engineer-in-Charge. for G+14 Storey buildings,Lifts.
Taking down old unserviceable main steel wire rope after disconnecting old main steel wire rope from counter weight, pulley and car cabin & providing new main steel wire rope 13mm dia, ungalvanised, 8/19 construction in and including necessary connection with counter weight, pulley & car cabin with clamps, nuts, bolts & washer etc complete all as directed by Engineer-in-Charge.
Disconnecting and taking out old/unserviceable Governer rope of size 8 mm dia(8/19 Construction) ungalvanised including necessery connection with pully in machine room and shaft pit complete with clamps, nuts bolts, and washers etc, for high rise building for 8/13/Goods lifts complete all as specified and directed by Engr-in-Charge. Make :- Usha Martin or equivalent as approved by GE.
Replacement of unserviceable cabin fan from car cabin, supply and fix, new cabin fan, non-oscilating type, axial flow, single speed 300mm sweep, 240 volts ISI marked with grill complete all as directed by Engineer-in-charge.
Disconnecting and taking out old/unserviceable travelling cable from hoist way and supply and fix new travelling cable PVC Insulated 16 Core with stranded copper conductor, 1100 volts grade of size 0.75 Sqmm conforming to relevant IS including criping with lugs appropriate thimples complete all as specified and directed by Engineer-in-Charge.Make Polycab/Finolex / Roliflex
Dismantling and taking out unserviceable safety edge of any type & supply and fixing new full beam infrared sensor upto full length of car doors (2.00 mtr) as specified and directed by the Engineer-in-Charge. Make : TLJONES/WECO/ESCON as approved by GE.
Replacement of automatic door drive unit with motor on car top with VVVF of 1 HP capaicity all as specified and directed by Engineer-in-Charge. Make : Yasakava / Sneider/Monarch as approved by Engineer- in - Charge.
Disconnecting and taking out defective u/s main drive( any type) from existing control panel and supply and fixing new main drive VVVF drive upto 11.0 KW in G+5/G+14 storey building complete with all electric connection. Make - Yaskawa/FUJI or equivalent as approved by GE.
Disconnecting and taking out defective u/s main drive( any type) from existing control panel and supply and fixing new main drive VVVF drive upto 15.0 KW in G+5/G+14 storey building complete with all electric connection. Make - Yaskawa/FUJI or equivalent as approved by GE.
Dismantling and taking out unserviceable old landing push button box along with illuminated call button with control wiring and supply & fix landing push button box complete with stainsless face plate 1.5mm thick having 02 push button and combined digital position indicator with arrow indicator complete including cutting walls for fixing of push button unit including making good to disturbed wall surface complete all as directed by Engineer-in-Charge.
Taking down and supply and fix hooter with emergency call announciator working on 12 Volts with audibility 90DB @ 1M distance (Make : Kheraj) with complete accessories like push button switches,alongwith box including connecting cables all as specified and directed by Engineer-in-Charge,
Schedule 'A' Part - III Manual operation of electrically operated lifts (6Ps,8 Ps & 13Ps) per Bldg, of any make and capacity daily 16 hrs in two shifts from 0600hrs to 1400hrs, 1400hrs to 2200hrs including cleaing, taking care of entire lift installation from any pilferage, theft or damage etc complete all as directed by Engineer-in-Charge for R-4,R-5,R-7,R-9,R-10,R-11,R-15,R-16,R-17,R-21, R-22, R-25, Makar, Kumbha, F-5, F-6 ( Total 16 Nos Building) for lift attendent (11 Months) (1x16x11= 176 )
Note for item No 13 (i) One Lift operator to be employed in each buildings/Lift per shift. (ii) Passes will be processed after verification of lift certificate, Pass shall not be granted without submission of qualification proof & experience certificate for lift operator. In case of OEM, the qualification mentioned in note is not applicable which shall be verified by Engineer-in-Charge before issue of passes (iii) Contractor shall submit ID proof, Residential proof, Bank A/C details to department and obtain approval of Engineer-in-Charge before employing a person as Operators. (iv) Payment to employees shall be done by crossed cheque through Aadhaar linked bank account only and it shall not be less than minimum fair wages as per act in vogue. The contractor shall submit proof to Engineer-in-Charge before claiming any payment. (v) Lift operators (semi skilled) report at lift cell as per the shift timings specified in the tender and he will report to JE E/M in-Charge or Lift Cell in-Charge. In case of emergency he will function according to their direction. If he is found absent or move without intimating to in-Charge of Lift Cell or JE E/M he will be treated as absent for the said shift and recovery to this effect for Rs 1500/- per shift shall be affected.
(vi) Payment as per quoted rate shall also be deducted in addition to the penalty as specified above. (vii) In case of malfunctioning if any noticed, lift operator shall intimate to the lift cell. (viii) In case of any necessity for rescue operation or in emergency situations, lift operator shall be capable of rescue the passenger and reacting to the situation (in emergency situations) Rescue operator engaged for rescue operation shall immediate attend the complaint within 30 minutes failing which penalty at Rs 500/- per hour or part thereof shall be levied. (ix) Contractor shall submit the labour licenece as applicable as per latest laws/acts & Copy of GST Regn registered number issued by concerned authority.
(x) Insurance coverage, compensation if any applicable or necessitated due to mis operation of lift shall be the responsibility of contractor. The quantum of compensation shall be assessed based on the BOO composing of Lift Inspector of Maharashtra State, representatives of both agencies carrying out M&O works and routine maintenance work of lift and members from department. (xi) Contractor has to submit proof of payment of EPF subscription made by him as applicable as per latest laws/acts alongwith RAR failing which RAR will not be progressed for payment. (xii) The rates quoted by the contractor shall be deemed to be included provision of all latest labour laws / regulations including all relevant taxes as applicable. (xiii) The bidders are advised not to quote rate less than minimum fair wages as circulated by competent authority. If the quoted amount is less than the estimated cost Item No 13 i.e Rs 48,36,480.00, the lowest bidder will have to deposit FDR/BGB as elaborated herein after in favour of Accepting Officer within 07 days of opening of financial bid (Cover No 2) .
(xiv). The deposited amount shall be the difference between estimated cost i.e Rs 48,36,480.00 and amount quoted by lowest bidder for respective item. FDR/BGB shall be released only after satisfactory completion of work. If the contractor fails to pay minimum wages to employees, the department shall have right to withhold the said amount which will be verified by GE. The decision of Accepting Officer regarding amount to be withhold shall be final and binding. The withhold amount will be utilised by GE for payment to employees if contractor fails to pay minimum wages and balance amount if any shall only be released. If the lowest bidder fails to deposit the amount as stated above within 07 days, the contractor shall be banned for 06 months & his bid shall be rejected. The contractor shall sumbit 03 Nos of BGBs/FDRs of equal amount as mentioned above. The BGBs/FDRs validity shall be 04 months, 08 month & 12 months respectively for the purpose of encashment/ release as the case may be. (xv) The rates quoted shall be inclusive of suitable reliver wherever sundays & holidays are mentioned for working
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .