Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC Firm is lowest |
| 2 | L2₹1.4 Cr+₹15.3 L (12.5%)Rejected-Finance | ₹1.4 Cr+₹15.3 L (12.5%) | L2 | Rejected-Finance FIRM IS L2 HENCE NOT ACCEPTED |
| 3 | Rejected-Technical | - | - | Rejected-Technical AS PER CWC DECISION, FIRM IS DISQUALIFIED IN TEC |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
14 Oct 2024, 5:00 pmClosed
Executive Director
O F Bhusawal
Construction of building for production activities near Tool room inside the factory at O. F. Bhusawal.
2024_YIL_208952_1
F/18/EO(C)/2024-25/C/5/ND2302
Open Tender
Civil Works - Buildings
Item Rate
180 days
O F BHUSAWAL
As per TEs eligibility criteria
4 documents required · 4 mandatory
₹0
₹2.2 L
25 Mar 2025
23 Sept 2024
17 Oct 2024
23 Sept 2024
14 Oct 2024
24 Sept 2024
24 Sept 2024 - 14 Oct 2024
Amount
Construction of building for production activities near Tool room inside the factory at O. F. Bhusawal.
Demolition Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles.
Demolition Cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for.
Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section 3-Earthwork) to a distance of 400m, beyond the lead included in the rates, including loading, unloading and stacking at the destination
Rough excavation not exceeding 1.5 m deep and getting out Hard/dense soil; And Removing excavated material exc. 250 but n exc. 500 m and depositing where directed.
Excavation in Hard Dense Soil in trenches for foundation n. exe 1.5 mtr wide and 1.5 M deep and Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed.
Shingle filling in floors or pavings, laid in layers n exc. 15cm thick, spread, levelled, and blinded with earth and rammed including watering complete
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15cm thick, spread levelled and rammed including watering complete.
Hardcore of guage exc 63mm but n exc. 100mm deposited, spread and levelled in layers n,exc. 15 cm thick watered and rolled/rammed to a true surface M&Lbroken stone or boulders.
Provision of cement concrete in foundations, filling and mass concrete Type C2 1:3:6 (40mm graded aggregate)
Provision of RCC nominal mix in Foundations, including rafts, footings, foundation beams, plinth beams: bases for columns, etc; basement slabs, under-reamed piles and mass concrete. Cement concrete Type BO 1:2:4 Type (12.5mm graded aggregate)
Provision of RCC nominal mix in in Columns, pillars piers, posts and struts Cement concrete Type BO 1:2:4 Type (12.5mm graded aggregate)
Provision of RCC nominal mix in Beams, canrtievers, bresssummers, intels over 1.5m span. Cement concrete Type B0 1:2:4 Type (12.5mm graded aggregate)
Provision of RCC nominal mix Walls, retaining walls, basement walls, ballast walls and the like, any |thickness; above top of footing: including attached pilaster and buttresses. Cement concreate Type BO 1:2:4 (12.5mm graded aggregate)
Provision of RCC nominal mix Chajja. Cement concreate Type BO 1:2:4 ( 12.5mm graded aggregate)
Cement concrete type B-2, 1:2:4 (40 mm graded aggregate) 100 mm thick in flooring, etc.
Supply and fixing deformed MS reinforcement 10 mm dia and over cut to length bent to shape and binding with wire annealed not less than 0.90 mm dia. TMT bars.
Supply and fixing defomed MS reinforcement 6-8 mm dia cut to length bent to shape and binding with wire annealed not less than 0.90 mm dia. TMT bars.
Formwork to sides of concrete foundations, footings bases of columns, raft and raft beams, sides and soffit (if any) of foundation and plinth beams; and similar work; vertical or to batter Rough finished surfaces of concrete flat.
Formwork to sides and soffits of floor or roofbeams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves incuding sup-ports, overhangs, etc. also splays between floors and beams, etc. Rough finished surfaces of concrete Flat
Form work to sides of pillars, posts, struts, piers, columns and stanchions, Rough finished surfaces of concrete Square, rectangular or polygonal
Centering to slab, chajjas
Brickwork with subclass 'B' bricks straight or curved on plan exc 6m mean Cement mortar,1:4.
M&L for rendering 12 mm thick in CM 1:4 on fair faces of block masonry or concrete surfaces. On Walls.
M&L for rendering 12 mm thick in CM 1:4 on fair faces of block masonry or concrete surfaces. On Ceilings
Preparation of new walls, Priming plastered and other surfaces with alkali resistant priming paint and application of TWo coats of cement paint all as directed complete.
Preparation of new in ceilings , Priming plastered and other surfaces with alkali resistant priming paint and application of Two coats of cement paint all as directed complete.
S&F Steel rolling shuters 1.25mm laths thickness, without ball bearing, as specified including top Cover, anchoring rod, hasp and stapple and one coat of primer errected in position as indicated, Complete with gear operated type with bevel gear box and crank handle.
Preparation of new Surfaces of any des-cription, over 10cm in width or girth, including priming with alluminium red oxide and application of Alluminium Paint two coat.
Steel windows with side hung shutters including projecting type hinges with steel handles, and steel peg stay complete with glazing bars, dovetailed or welded supply and fixed
Sheet glass, ordinary quality and glazing with oil putty in squre exc 0.5 sq.m in each pane thickness in mm 5.5
Preparation of New surfaces of steel and steel based surfaces of any description over 10 cm width or girth including knoting and stopping. with one coat of red oxide/zinc chrome primer and application of two coats of synthetic enamel paints all as specified and directed complete
Roof trusses (framed), trussed, purilins, crane gantries, rails and fastenings and heavy brackets framing (beam.tee angle, channel or flat sections) including distance pieces, leats etc S & F Fe 410-W (Gde-E 250) Quality-A
Plates (plain or chequered) channels, squre cut or notched (irdubart and counter sunk forming holes, without any attachment S & F Fe 410-W (Gde-E-250) Quality-A
Pre-painted galvatume aluminum zinc coating Gl based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 450Mpa as in roof covering/cladding to wall, fixed with self tapping |screws as specified S & F.
Mild steel bolts purpose made with hexagonal or squre head one end and screwed the other, or screwed both ends: each screwed end to be Fitted with washers and one hexagonal or square nut. Exc 30cm long S & F Diameter of neck in mm exc 20 & n exc 25
Providing &fi xing wind operated Turbo ventilator system stainess steel (24" dia) over existing roof including cutting of sheets, proper fixing in position to true line and level with all fixtures and fastenings, providing 0.80 mm thick FRP sheet for covering area between roof and fan so as to provide water proof joints with approved water proofing compound, making good the roof surface including cleaning, etc. complete. (General application for all types of roofs for ventilation and day light purpose).
S & F Fibre glass reingorced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc, (any thickness), fixed with L- type or J-type hooks
Bands, straps, supports or stays for valley gutter, rainwater, ventilating pipes, including bolts, if reuired: hooks (staya), heavy, for large gates, hook and pintle hinges; large hasps and staples' chains; hand made sliding bolts; champs; hold fasts; wall ties: hooks for hanging fans: plain angle cleats for securing purlins to wood trusses or refetrs; knee piece inserts; two way and three way straps, plate washers and
Plain, back mild steel Sheeting, in rides hips, valley gutters, drip and straight flashings (lenght and girth as fixed) S & F Thickness in mm 1.25; with welded joints complete.
Preparation of New surfaces of steel and steel based surfaces of any discnption over 10 cm width or girth including knoting and stopping, with one coat of red oxide primer and application of two coats of black bituminous paint conforming to IS 9862 - 1981 all as specified and directed complete
drop ends (for spigot or socket ends) or nozzles Supplied & fixed Thickness of sheet 1.25 mm dia mm 150mm
S/Fixing UPVC Pipes (SCH-40) in rain water pipes eith connections as required like bend/elbow sockets etc jointed with solvent cement 150mm dia with complete fittings like bend, socket.
VILAS PATIL AND ASSOCIATES (BID ID -756091)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .