Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-Finance VILL KAKDWIP SUBHASH NAGAR P O KAKDWIP DIST SOUTH 24 PARGANAS PIN 743347 | KAKDWIP | SOUTH 24 PARGANAS | WEST BENGAL | 743347 | ₹10.0 L | L1 | Accepted-Finance L1 |
| 2 | L2₹10.2 LAccepted-Finance 6 2A CREEK LANE CALC UTTA 14 700014 | KOLKATA | WEST BENGAL | 700014 | ₹10.2 L | L2 | Accepted-Finance L2 |
| 3 | L3₹10.3 LRejected-Finance 15A PALMER BAZAR ROA D CAL 15 700015 | KOLKATA | WEST BENGAL | 700015 | ₹10.3 L | L3 | Rejected-Finance L3 |
Tender Value
₹10.0 L
EMD Value
₹20,000
Closing Date
31 Jan 2026, 5:00 pmClosed
D.G.(S and D)
Office of the Director General (Sewerage and Drainage), SEWARAGE and DRAINAGE department Kolkata Municipal Corporation 5, S.N. Banerjee Road Kolkata-700 013 West Bengal
Rainwater harvesting and greenbelt formation area solar lighting at Itkhola - I in ward no. 114.
2026_KMC_991172_1
KMC/S_D/ITKHOLA/LTG/25-26
Open Tender
Electrical Work/ Equipment
10 days
MDPS/ITKHOLA
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹20,000
7 Mar 2026
20 Jan 2026
2 Feb 2026
20 Jan 2026
31 Jan 2026
20 Jan 2026
150 Amp TPN Busbars of CU alloy as per SLD (supply of Cu Busbar for electrical power distribution. Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE -2022 item no. 5.3 D5, page no 105.
Supply of 3 pole Thermal over load Relay type MN-12L, Relay range 60A to100A current rating.. Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE -2022 item no. 5.3 D35, page no 106.
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection Legrand, FP, 100 A.... Rate as per PWD Elect. Sch. rate -2017, ITEM NO. 10 page no-D-8.
Supply and delivery of extended rotary handel of MCCBs (Make: L & T/ABB/ Schneider/Simence/ GE)b) Extended rotary handle 100-160A, 415V… Rate as per UDMA ELECT-MECH SCHEDULE -2018 item no. 52. b), page no 21
Supplying and fixing MCCB SS enclosure with IP- 20/30 protection, pwder coated provision for housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish / on flat iron frame incl. painting, connection & provision for earthing attachment Legrand...Rate as per PWD Elect. Sch. rate -2017, ITEM NO. 12 page no-D-9.
Supply and delivery of spreader Terminal of MCCBs (Make: L & T/ABB/ Schneider/Simence/ GE). a) 100A, 3 pole…. Rate as per UDMA ELECT-MECH SCHEDULE -2018 item no. 53. c), page no 21
Supply and fixing of 240/230 volt, 50 Hz, T.P., power contactor (Make: L & T/ABB/Schneider/Simence/ GE) having contact block of the following range. g) 50-85Amp, 2NO+2NC... Rate as per UDMA ELECT-MECH SCHEDULE -2018 item no. 18. i), page no 16
Supply of 1 pole Electronic Timer type ST100,3-30 Second/ 12-120 Second… Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE -2022 item no. 5.3 D41, page no 107.
Supply of 240V AC analog time switch for ON-OFF control of street light.. Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE -2022 item no. 5.3 D13, page no 105.
Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification. Supply of 3 Ph LED Ammeter Cl 0.5…Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE -2022 item no. 5.3 D2, page no 105.
Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification. Supply of 3 Ph LED Voltmeter Cl 0.5…Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE -2022 item no. 5.3 D3, page no 105.
Supply & fixing of 230/240V, LED indicating lamp (make :AE/KAPPA/IMP) Blue/ white color… Rate as per UDMA ELECT-MECH SCHEDULE -2018 item no. 22. a), page no 17
Supply & fixing of control switch of 25A, D.P., 415 V of ON/OFF of type (make :Siemens/ ABB/L&T / Schneider)... Rate as per UDMA ELECT-MECH SCHEDULE -2018 item no. 22. a), page no 17
Installation the feeder pillar box only on cement brick foundation including plastering and neat cementing as per specification and direction of E.I.C...Rate as per UDMA ELECT-MECH SCHEDULE -2018 item no. 35, page no 6
Supply and delivery of 320W (peak) solar PV Module with multi crystalline solar cell ( Make: TATA/WEBSOL)...Rate as per UDMA ELECT-MECH SCHEDULE -2018 item no. 2, page no 57
Supply and fixing of Micro Inverter (Outdoor type) (Make: L&T/ABB/EXIDE/KACO/POWER ONE ) of capacity 300W and provision to auto synchronize with grid (230 Volt, 50Hz). The inverter should have built in protection system...Rate as per UDMA ELECT-MECH SCHEDULE -2018 item no. 3, page no 57
Supply and fixing of LED Bollard (10 watt) complete with all accessories Make: Philips, 10 watt………… Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE -2022 item no. 5.3 F14.0.1, page no 112.
Erection of Minipole of height 3.25 mtr to 5.0 mtr. in C.C Foundation 0.46 m * 0.46 m * 0.9 mtr depth of 1:3:6 cement concrete with hard jhama metal / stone chips including muffing of 0.3 m * 0.3 m * 0.3 m painting the pole with 2 coats of Aluminium paint over a coat red oxide... Rate as per UDMA ELECT-MECH SCHEDULE -2018 item no. 4, page no 3
Supplying and fixing of M.S. sole plate (450 x 450 x 6m)At the bottom of the pole… Rate as per UDMA ELECT-MECH SCHEDULE -2018 item no. 5, page no 3
Supplying and Erection of additional foundation having Dimension of 600 * 600 * 600 mm C.C foundation (6:3:1) with graded stone chips (3/4" down) providing R.B. Net of 2" * 4" in size including neat cementing… Rate as per UDMA ELECT-MECH SCHEDULE -2018 item no. 7, page no 4
S/F M. S. loop box (10 SWG) of size 10.3/4 “x 8.3/4” x 5" (269mm x 219mm x125mm) having almirah type cover complete with special type locking arrangement including S/F 8 “x6” x1/4" (200mm x 150mm x 6 mm) bakelite sheet 1 no. 4-way ebonit connector block, 1 No. 15 Amp fuse unit fitted inside the box and suitable size danger board riveted on cover of the box outside & fixing the box with pole by means of M.S. Clamps of 1"x1/4" (25mm x 6mm) of suitable length and encasing the box by 1:3:6 cement concrete with graded stone chip (3/4" down). The depth of the concrete should be 60cm x 54cm x 54cm including plastering and neat cementing and S/F 2 Nos. compression gland of suitable size and making all necessary connections as reqd.... Rate as per UDMA ELECT-MECH SCHEDULE -2018 item no. 34, page no 6
Supply and fixing of smart bright essential street light (70 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes / providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sq mm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. Make : Crompton, 72 watt.… Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE -2022 item no. 5.3 F10.0.4, page no 112
SSupply and fixing of greenline V2 street light (115 Watt) complete with all accessories to be fixed / projected from the wall of the building or on pole incl. making holes / providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc Make : Bajaj, 120 W LED.… Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE -2022 item no. 5.3 F11.0.3, page no 112
SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR ARMORED CABLES OF 1.1KV GRADE AS PER IS7098 (PART1) 1988 WITH UPTO DATE AMENDMENTS. (Rate in Rs.Per Mtr) Conductor cross section in SQ MM 25 × 4 CORE....Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE -2022 item no. 5.3 A2, page no 101
SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR ARMORED CABLES OF 1.1KV GRADE AS PER IS7098 (PART1) 1988 WITH UPTO DATE AMENDMENTS. (Rate in Rs.Per Mtr) Conductor cross section in SQ MM 10, 4 CORE....Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE -2022 item no. 5.3 A2, page no 101
SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR ARMORED CABLES OF 1.1KV GRADE AS PER IS7098 (PART1) 1988 WITH UPTO DATE AMENDMENTS. (Rate in Rs.Per Mtr) Conductor cross section in SQ MM 6, 4 CORE....Rate as per Irrigation & Waterways Dept. Govt. of W.B. ELECT-MECH SCHEDULE -2022 item no. 5.3 A2, page no 101
Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction) f) 50mm dia 3mm thick Polythene Pipe Rate as per PWD Elect. Sch. rate -2017, ITEM NO. 1 f) page no-E-2.
Laying through Underground Trech: Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.. Rate as per PWD Elect. Sch. rate -2017, ITEM NO. 1 A) page no-F-2.
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core.. Rate as per PWD Elect. Sch. rate -2017, ITEM NO. 3 A) page no-F-1.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : (c)For 4 core upto 25 sqmm.. Rate as per PWD Elect. Sch. rate -2017, ITEM NO. 7 c) page no-F-4.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : (c)For 4 core upto 6 sqmm.. Rate as per PWD Elect. Sch. rate -2017, ITEM NO. 7 c) page no-F-4.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : (c)For 4 core upto 10 sqmm.. Rate as per PWD Elect. Sch. rate -2017, ITEM NO. 7 c) page no-F-4.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : : (xvi) 4 core 25 sqmm cable.. Rate as per PWD Elect. Sch. rate -2017, ITEM NO. 8 b) viii page no-F-5.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : : (xi) 4 core 10 sqmm cable.. Rate as per PWD Elect. Sch. rate -2017, ITEM NO. 8 b) xi page no-F-5.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : : (x) 4 core 6 sqmm cable.. Rate as per PWD Elect. Sch. rate -2017, ITEM NO. 8 b) x page no-F-5.
Supplying and Drawing 1.1 KV single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required . item no. C. 1.e . 3 x 36/0.3 (2.5 sqmm) Rate as per PWD Elect. Sch. rate -2017, page no-E-9.
Supplying and Drawing 1.1 KV single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required item no. C. 1.d. 2 x 36/0.3 (2.5 sqmm). Rate as per PWD Elect. Sch. rate -2017, page no-E-9.
Supplying and Drawing 1.1 KV single core stranded 'FR'PVC insulated & unsheathed single core stranded copper wire(Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required item no. C. 1.a. 2 x 22/0.3 (1.5 sqmm). Rate as per PWD Elect. Sch. rate -2017, page no-E-9.
Distn.wiring in22/0.3(1.5sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC (i) Average run 6 mtr... Rate as per PWD Elect. Sch. rate -2017, item no. G 1.i. page no-E-20.
Distn.wiring in 22/0.3 (1.5sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3mm thick polythen pipe complete with all accessories embedded in wall to 240V 6A 5pin plug point incl. S&F 240V 6A 3pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4Module GI switch board with3/4Module top cover plate flushed in wall incl. mending good damages to original finish....Rate as per PWD Elect. Sch. rate -2017, item no. G 3 V., page no-E-20.
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand, 6-32 A, SP. Rate as per PWD Elect. Sch. rate -2017, ITEM NO. 7page no-D-6.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Legrand 2+8 way Enclosure (607711). Rate as per PWD Elect. Sch. rate -2017, ITEM NO. 7page no-D-6.
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N&E) fixed on bakelite / Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. D) 12 Module...Rate as per PWD Elect. Sch. rate -2017, item no. F 1D., page no-E-17.
Single Phase Submersible Pump set A Per Latest BIS (Without Panel Board):- Supqly and delivery of clear water verticat wet type submersible pump suitable for bore well conforming to IS : 8034 ( and as amended thereafter ) with standard MOC for portable clear cold water and BEE 3 Star Rated.capable of discharging noted M3/h. against head of water column. The pump shall be directly coupled with a continuous rated 2- pole suitable wet type vertical squinel cage induction motor. conforming to IS : 9253 (and as amended thereafter ), suitable for operation in A-C Single phases 220 v, 50 Hz, (Category B Motor): Minimum Bore well Dia-75 mm, HP-1, No of Stage- 12, Head (H) in Metre- 24, Discharge(Q) in M3/Hr- 4.2, NRY Size in mm- 32..... RATE as per PHE SOR- MECH. ELECT. works GOVT. OF WB. SCH. Rate- NOV-2021, Item Sl. no. A-23, page no-9
SINGLE PHASE SUBMERIBLE PUMP CONTROLLER (Microprocessor Based) WITH WATER LEVEL CONTROL-Supply and delivery of direct on line ( DOL) strater panel board confonning to ISl3947 and IEC 947 of suitable HP rating for operation in 230V (± 10%) AC , single phase , 50Hz (±5 %) comprising of ammeter, voltnreter, thermal overload relay, 2 pole magnetic contactor with in built water Ievel control, under voltage protection, indicating lamp. capacitors, on/off push buttons including 5 way connector, wiring with l/1,5 sq. mm PVC insulated copper wire. powder coated vermin proof box of following capacities: (i) I H.P. (Relay Range 6-10 Amp.)... .. RATE as per PHE SOR- MECH. ELECT. works GOVT. OF WB. SCH. Rate- NOV-2021, Item Sl. no. 1-i, page no-4
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (a) For Exposed Work (i) CPVC Pipes Class-1, SDR-11 -50 mm Dia.. Rate as per PWD Sanitary & plumbing works vol-ii. Sch. Rate-2017 item no. 1 A, page no 29
(b) For Concealed Work: (i) CPVC Pipes Class-1,SDR-11- 25mm Dia.. Rate as per PWD Sanitary & plumbing works vol-ii. Sch. Rate-2017 item no. 1 B, page no 29
Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007.. (I) Tank connecting nipple.. 50 MM Dia… Rate as per PWD Sanitary & plumbing works vol-ii. Sch. Rate-2017 item no. 2 I, page no 31
Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes & fittings conforming to IS-15778: 2007.. (I) Tank connecting nipple.. 25 MM Dia… Rate as per PWD Sanitary & plumbing works vol-ii. Sch. Rate-2017 item no. 2 I, page no 31
Supply and fixing the water injection nozzle in form of cork screw or like end auger of dimension 80 mm height x 25.4 mm dia hexagonal tapered having thread at one side with 4mm dia drill hole centrally in which water may be spared wildly spirally like fly wheel at a normal pressure of water complete machining and testing.… Rate as per UDMA ELECT-MECH SCHEDULE -2018 item no. 54, page no 45
Soil Excavation : Excavation of soil for installation of Earth Electrode and filling & ramming (b)For Morrum Soil. Rate as per PWD Elect. Sch. rate -2017, item no. 1 (b)., page no-G-1.
Earthing with 50 mm dia GI pipe3.64 mm thick x3.04 Mts. long and 1x4 SWG GI (HotDip) wire (4Mts. long),13mm dia x 80 mm long GI bolts, double nuts,double washers incl.S& F 15 mm dia GI pipe protection (1Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below (a) By ISI-Medium GI pipe:. Rate as per PWD Elect. Sch. rate -2017, item no. 2 (a)., page no-G-1.
Connecting the equipments to earth busbar including S & F GI(Hot Dip) wire of size as below on wall/floor with staples buriedinside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. asrequired and mending good damages.Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. Rate as per PWD Elect. Sch. rate -2017, item no. 5a (ii)., page no-G-2
Supply Delivery and installation of ABC Powder type fire extinguishers (stored pressure) HSN code-84241000 conformingto IS:15683 and complete in all respect as per direction of EIC . 06 Kg with ISI marked Mono Ammonium Phosphate base.ABC power conforming to IS:14609 and pressurized withnitrogen gas. Suitable for operating between (-)30ºC to(+)55ºC. Fire rating -2A & 21B. Rate as per UDMA elect-mech sch. rate-2018 basis item no.24, page 77
Sub Total
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.93 MB
BOQ_2423288.xls
BOQ • 0.37 MB
FORM.pdf
Tender Documents • 0.66 MB
Download all tender documents and submit your bid