Loading…
Loading…
Tender ID
Tender Value
₹9.1 Cr
EMD Value
₹5 L
Closing Date
13 Apr 2026, 5:00 pmClosed
- Gopal Narayan Tiwari(DFLT)
CGSWC
CONSTRCTION OF GODOWN COMPLEX-(GROUP NO. 09) BHATAPARA 14400 MT [Total 14400 MT]
187351
No ./3212/CGSWC / CONST. / 2025-26 / Nawa Raipur Dt- 18.03.2026
RESTRICTED TENDER
WORKS
PERCENTAGE
12 days
CGSWC
Required Past Technical Experience: AS PER NIT Document
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
16 documents required · 16 mandatory
Chhattisgarh State Warehousing Corporation (CGSWC)
WORKS
- Gopal Narayan Tiwari(DFLT)
RESTRICTED TENDER
PERCENTAGE
A B
CGSWC
TENDER SECTION
CGSWC
120
12
No
0
187351
13 Apr, 2026 5:00:00 PM IST
15 Apr, 2026 11:01:00 AM IST
20 Mar, 2026 5:00:00 PM IST
No ./3212/CGSWC / CONST. / 2025-26 / Nawa Raipur Dt- 18.03.2026
CONSTRCTION OF GODOWN COMPLEX-(GROUP NO. 09) BHATAPARA 14400 MT [Total 14400 MT]
500000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
91249000.00
2
91249000
AS PER NIT
AS PER NIT
AS PER NIT Document
0.00 INR
24d 15h 58m
16 documents required · 16 mandatory
₹0
₹5 L
20 Mar 2026
20 Mar 2026
15 Apr 2026
20 Mar 2026
13 Apr 2026
20 Mar 2026
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).
Excavation for all types of foundations,trenches and drains or for any othere purpose including disposal of excavated stuff upto 50m lead and a lift upto 1.50 M. (at least 5.00 M. away from the excavated area) including dressing and leveling of pits. In all types of soil.
Exvavation for all types of foundations,trenches and drains or for any othere purpose including disposal of excavated stuff upto 50m lead and a lift upto 1.50 M. (at least 5.00 M. away from the excavated area) including dressing and leveling of pits. In ordinary rocks
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size).
1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete.Thrermo-mechanically treated bars.
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Up to 4.00 M. Height
Above 4.00 M. to 8.00 M.
Above 8.00 M. to 12.00 M.
Providing and fixing formwork i/c centering, shuttering, strutting, staging, propping bracing etc complete and including its removal all levels for :Foundations, footing, base of columns and plinth beam in any shape and size.
Columns-rectangular or square in shape. (i) Up to 4m height
Above 4.00 M. to 5.00 M.
Above 5.00 M. to 6.00 M.
Above 6.00 M. to 7.00 M.
Above 7.00 M. to 8.00 M.
Above 8.00 M. to 9.00 M.
Wall of any thickness including attached pilasters, buttresses etc.
Above 6.00 M. to 7.00 M.
Above 7.00 M. to 8.00 M.
Above 8.00 M. to 9.00 M.
Above 9.00 M. to 10.00 M.
Window sills, anchor blocks, string course, bends, copings, bed plates and like. (i) upto 4 mt.
4mt to 5 mt
(D) weather shade chhajja cornies and moulding.
Suspended floor roof access plate form balconies (plain surface)and shelves(cast in situ)
Edge of slab breaks in floorand wall up to 200mm
Beams, lintel, cantilevers & walls.
Above 5.00 M. to6.00 m
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in:Cement Mortar 1:6 (1 Cement : 6 Sand)
Extra for brick work In S/S above plinth & up to floor five level.
Extra for brick work In S/S above 4.00 m & upto 8.00 M
Filling from available stuff (Excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20cm. in depth consolidating each deposited layer by ramming and watering with a lead up to 50M. and lift up to 1.5M.
Providing and filling in plinth with sand/Crusher dust and hard moorum under floor in layers not exceeding 20 Cm. In depth consolidating each deposited layer by ramming & watering including dressing etc complete.
Extra for providing & fixing 4 mm. Thick glass strips in joints of Terrazzo floor/ cement concrete floor & or like. 40 mm. wide
60 mm. Wide
Cement concrete flooring with cement concrete 1:2:4 concrete (1 cement : 2 course sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 50mm thick
75mm thick
Providing and making 12mm thick cement plaster of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and laying vitrified floor tiles with double charge/ multi charge printing with water absorption less than 0.5% and conforming to IS : 15622 of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm
Providing and fixing factory made ISI marks steel doors, windows and ventilators side/ top/ centre hung made up of standard rolled steel section conforming to IS 1038:1968 (viz. F7D, F4B, K11 and K12B etc.), joints mitred and flash butt and sash bars tenoned and riveted/ welded with 10 cm long lugs of size 15x3mm embedded in cement concrete block 15x10x10 cms of 1:3:6 (1 cement :3 Coarse sand: 6 graded stone aggregate 20 mm nominal size) or rawl plugs and screws or with bolts and nuts as required including providing and fixing of hinges, pivots, handles, pegs, stays, rolling devices, locking arrangements, spring catch etc., as required complete including applying a priming coat of red oxide zinc chromate primer.
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: For fixed portion
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading.With float glass panes of 6 mm thickness
Providing and fixing stainless wire gauge of average width of aperture 1.56mm with wire of 0.35mm to existing steel door, window shutter frames with necessary M.S. strip beading etc. complete.
Providing and fixing 2mm thick semi transparent polycarbonate profile roofing sheet of approved make and colour to make any normal roofing / covering and fixing as per manufacture specification at spacing not more than 1.2 m centre to centre with EPDM gasket and silicon sealant fixed with self drilling stainless steel screws all complete as per direction of Engineer-in-Charge
Supplying and fixing rolling shutter of approved makes made of M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft, with brackets, side guides and arrangements for inside and out side locking with push and pull arrangement complete but excluding the cost of top cover and spring.80 x 1.25 mm. M.S. laths
Extra for providing grilled rolling shutter manufactured out of 8 mm dia. M.S. bar instead of laths as per approved design (area of grill provided, only to be measured).
Providing and fixing 27.5cm. long wire spring for rolling shutters.
Providing and fixing M.S. sheet top cover for rolling shutter.0.90 mm. thick
Providing andfixing ball bearing for rolling shutters.
Providing and fixing M.S. frames of doors, windows and ventilators joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.In Angle-iron frames
Providing and fixing in position welded steel wire fabric to concrete/ wooden/ angle iron posts including securing and screwing with G.I. tying wire, G.I. stapples, G.I.U-nails or steel pins etc., complete. Aperture 50x25mm
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.30 mm. thick (single leaf)
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 250 x10mm
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 250 x10mm
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 300mm
Providing and fixing stainless steel hanging door stopper with necessary stainless steel screws complete. Single
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete. 150 mm
Providing and fixing stainless steel piano hinges with necessary stainless steel screws etc complete. Overall width 25 mm
Steel work in tubular structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.Electric resistance or induction butt welded tubes Grade-300. Upto 5.00 M. height.
Above 5.00 M. height.
Extra for providing and fixing wind ties of 40 x 6 mm flat iron section.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Crimp curve
Supply and fixing of polymer precoated galvalume profile sheets (PPGL) of approved size, shape and pitch of corrugation, total coated thickness (TCT) 0.60 mm +/- 5%, epoxy primer on both side of the sheet and colour polyester top coat 18-20 microns and 6-7 microns on bottom. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 6mm thick cement plaster of mix:n Cement mortar 1:4 (1 cement : 4 fine sand)
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: Cement Mortar 1:4 (1 cement : 4 coarse sand)
Extra for lining over plaster to imitate stone or concrete block walling.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Providing and applying 2mm thick ready mix exterior grade approved make putty (like Birla wall care, Alltek Superfine W/R of (NCL), Asian, ICI, Nerolac, J.K. wall putty) on walls to make the surface smooth and even.
Applying one coat of cement primer on wall surface (applied @ 0.80 litrs/10 sqm) complete.
Painting exterior surface with ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Painting on new work (two or more coats) to give an even shade with: Satin synthetic enamel paint
Painting on new work (two or more coats) to give an even shade with: Aluminium paint
Wiring for light/ fan/ exhaust fan / call bell point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in concealed PVC conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable as required. Short Point
Medium point
Long point
Extra for providing and fixing light plug point on board in concealed PVC conduit point wiring with modular type 3 pin 5 amp socket outlet and 5 amp switch including cost of base and cover plate and G. I. box etc. as required.
Wiring for light plug point with 2x2.5 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Medium Point
Wiring for light plug point with 2x2.5 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Long Point
Wiring for power plugpoint with2x4sqmmFRPVC insulatedstrandedcopperconductorcable inconcealed PVCconduitalongwithmodular type16Ampswitchand 6pin16ampssocketoutletwithmodularbaseandcover plate,suitablesizeG.I.box,earthingtheswitchboxand socket outlet with same size cable etc. as required. Medium Point
Long Point
Wiring for circuit / sub main wiring allong witrh earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in concealed steel conduit as required. 3x2.5 sq. mm in 20 mm conduit
6x2.5 sq. mm in 20 mm conduit.
9 X 2.5 sq. mm in 32mm conduit
Earhting with copper earth plate 600 mm X 600 mm X 3 mm thkick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe.
Supplying and laying 8 SWG copper wire at 0.50 meter below ground level for conductor earth electrode, i/c solding etc. as required.
Providingandfixingmetalclad,SP&Nswitchfuseunit(re wirable), 230/250 volts, withporcelain re-wireble fuses including drilling holes on the board, connections, earthingthebodyetc. as required. (Thimbelingshall be paid separately). 32 amps
Supplyingandfixingonsurface/ recessprewiredvertical type followingway, 415 volts TP&N, MCBdistribution boardof sheet steel phosphatizedandpowder painted completewithloosewirebox, terminalblocks,200amps tinnedcopperbusbar,commonneutral link,earthbar,din bar, detachable gland plate, loosewire box, superior maketerminal connectors forall incomingandoutgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks includinginterconnections,earthingetc.asrequired. (But withoutMCB/ RCCB/ Isolator) (Note: Prewired vertical typeMCBTPDBisnormallyusedwhere3phaseoutlets are required.)8 way (4 + 24), Single door
Providing and fixing following capacity TP&N disconnector fuseswitchunit inside theexistingcubicle panelboardwithISImarkedHRCfusesincludingdrilling holes incubiclepanel,makingconnections, testingand commissioning etc as required. (Connecting lead if required shall be paid separately) 100 Amp TP&N
63 Amp TP&N
32 Amp TP&N
Supplyingand fixingonsurface/ recess followingway, 240voltsSP&NMCBdistributionboardof sheet steel phosphatizedandpowder paintedcompletewith tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way, Single door
Supplyingand fixingonsurface/ recesshorizontal type followingway,415volts,TPNMCBdistributionboardof sheet steel phosphatizedandpowderpainted, complete withtinnedcopperbusbar,neutralbusbar,earthbar,din bar, detachableglandplate, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door
Supplying and fixing DPMCB, 240 volts, 'C' curve, suitablefor lightingandother loads intheexistingMCB DB complete with connections, testing and commissioning etc. as required. 6 amps to 32 amps
Supplying and fixing TPMCB, 440 volts, 'C' curve, suitablefor lightingandother loads intheexistingMCB DB complete with connections, testing and commissioning etc. as required. 6 amps to 32 amps
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps.
Supplyingand fixing following rating, 415volts, FOUR POLES, ISOLATOR in theexistingMCBDBcomplete with connections, testing and commissioning etc. as required. 63 amps
Providingandfixingporcelainre-wireblefusecarrierand baseunitonwoodenboardincludingdrillingholesonthe board,screws,connectionsetc.asrequired. (Thimbeling shall be paid separately)100 amps
Supplyingand laying followingsizesonenumber PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminiumconductorpowercableof1.1KVgradedirect in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.4 x 25 sq. mm.
4 x 10 sq. mm
SupplyingandhangingfollowingsizesonenumberPVC insulated/ XLPE, PVC sheathed, steel armoured, aluminiumconductorpowercableof1.1KVgradeonGI bearer wire (binded at everymetre) including cost of bearer wire complete as required. 4 x 25 sq. mm. on 7 SWG GI bearer wire
4 x 10 sq. mm. on 8 SWG GI bearer wire
Supplyingandfixingmetalcladbusbarchambermadeof 1.6mmthickCRCAsheetwith4stripcopperbusbarsof following capacity and length, complete with all accessories, including earthing the body etc. as required. 200 amps x 450mm long
Providing and fixing round/ hexagonal fan box (125 mm. dia) depth 75mm. (max) with 12 mm. dia steel bar hook, 1.6 mm. thiuck MS sheet cover, in RCC slab etc. as required
Supplyingandfixingmetalboxof followingsizes(nominal size)inrecesswithsuitablesizephenoliclaminatedsheet cover in front including painting etc as required. 75 mm X 75 mm X 60 mm deep
100 mm X 100 mm X 60 mm deep
150 mm X 75 mm X 60 mm deep
180 mm X 100 mm X 60 mm deep
200 mm X 300 mm X 60 mm deep
Supplying, instaling, testing and commissioning of following sizes ceiling fan with resistance type regulqator, i/c wiring the down fods of standard length up to 30 cm. with 1.5 sq. mm. FR PVC insulated, copper conductor, sinle core cable, earthing etc. complete as required. 1200 mm. sweep
Supplying, installation, testing and commissioning of following T-5 fluorescent fitting (luminaries) complete with electronic ballast but without fluorescent lamp, on ceiling/ wall surface, earthing the fitting etc. as required. Single box type with decorative end caps
Supplying, fixing, testingandcommissioningof following 230/250volts fluorescent lamp(tube) inexisting lighting luminaries as required. 4' x 28 watt (T-5)
Supplying, fixing, testingandcommissioningof following LEDlampswithinbuiltelectronicdriverheatsinkandall other accessories in existing holder/ luminaries as requiredandfurnishing2YrsGuaranteecertificatefrom manufacturer. 9 Watt
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 5 KV surge protection on pole bracket complete as required and furnishing 2 Yrs Guarantee certificate from manufacturer. 40-45 watt
Supplying and fixing followingmodular switch, socket, otheraccessoriesontheexistingmodularplate&switch box including connections but excludingmodular plate etc. as required. Blanking plate
Batten/ angle holder
Ceiling rose 3 pin 5 amp
Wiring for light/ fan/ exhaust fan / call bell point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in concealed PVC conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable as required. Short Point
Medium point
Long point
Extra for providing and fixing light plug point on board in concealed PVC conduit point wiring with modular type 3 pin 5 amp socket outlet and 5 amp switch including cost of base and cover plate and G. I. box etc. as required.
Wiring for light plug point with 2x2.5 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Medium Point
Wiring for light plug point with 2x2.5 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Long Point
Wiring for power plugpoint with2x4sqmmFRPVC insulatedstrandedcopperconductorcable inconcealed PVCconduitalongwithmodular type16Ampswitchand 6pin16ampssocketoutletwithmodularbaseandcover plate,suitablesizeG.I.box,earthingtheswitchboxand socket outlet with same size cable etc. as required. Medium Point
Long Point
Wiring for circuit / sub main wiring allong witrh earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in concealed steel conduit as required. 3x2.5 sq. mm in 20 mm conduit
6x2.5 sq. mm in 20 mm conduit.
9 X 2.5 sq. mm in 32mm conduit
Earhting with copper earth plate 600 mm X 600 mm X 3 mm thkick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe.
Supplying and laying 8 SWG copper wire at 0.50 meter below ground level for conductor earth electrode, i/c solding etc. as required.
Providingandfixingmetalclad,SP&Nswitchfuseunit(re wirable), 230/250 volts, withporcelain re-wireble fuses including drilling holes on the board, connections, earthingthebodyetc. as required. (Thimbelingshall be paid separately). 32 amps
Supplyingandfixingonsurface/ recessprewiredvertical type followingway, 415 volts TP&N, MCBdistribution boardof sheet steel phosphatizedandpowder painted completewithloosewirebox, terminalblocks,200amps tinnedcopperbusbar,commonneutral link,earthbar,din bar, detachable gland plate, loosewire box, superior maketerminal connectors forall incomingandoutgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks includinginterconnections,earthingetc.asrequired. (But withoutMCB/ RCCB/ Isolator) (Note: Prewired vertical typeMCBTPDBisnormallyusedwhere3phaseoutlets are required.)8 way (4 + 24), Single door
Providing and fixing following capacity TP&N disconnector fuseswitchunit inside theexistingcubicle panelboardwithISImarkedHRCfusesincludingdrilling holes incubiclepanel,makingconnections, testingand commissioning etc as required. (Connecting lead if required shall be paid separately) 100 Amp TP&N
63 Amp TP&N
32 Amp TP&N
Supplyingand fixingonsurface/ recess followingway, 240voltsSP&NMCBdistributionboardof sheet steel phosphatizedandpowder paintedcompletewith tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way, Single door
Supplyingand fixingonsurface/ recesshorizontal type followingway,415volts,TPNMCBdistributionboardof sheet steel phosphatizedandpowderpainted, complete withtinnedcopperbusbar,neutralbusbar,earthbar,din bar, detachableglandplate, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way Double door
Supplying and fixing DPMCB, 240 volts, 'C' curve, suitablefor lightingandother loads intheexistingMCB DB complete with connections, testing and commissioning etc. as required. 6 amps to 32 amps
Supplying and fixing TPMCB, 440 volts, 'C' curve, suitablefor lightingandother loads intheexistingMCB DB complete with connections, testing and commissioning etc. as required. 6 amps to 32 amps
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps.
Supplyingand fixing following rating, 415volts, FOUR POLES, ISOLATOR in theexistingMCBDBcomplete with connections, testing and commissioning etc. as required. 63 amps
Providingandfixingporcelainre-wireblefusecarrierand baseunitonwoodenboardincludingdrillingholesonthe board,screws,connectionsetc.asrequired. (Thimbeling shall be paid separately)100 amps
Supplyingand laying followingsizesonenumber PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminiumconductorpowercableof1.1KVgradedirect in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.4 x 25 sq. mm.
4 x 10 sq. mm
SupplyingandhangingfollowingsizesonenumberPVC insulated/ XLPE, PVC sheathed, steel armoured, aluminiumconductorpowercableof1.1KVgradeonGI bearer wire (binded at everymetre) including cost of bearer wire complete as required. 4 x 25 sq. mm. on 7 SWG GI bearer wire
4 x 10 sq. mm. on 8 SWG GI bearer wire
Supplyingandfixingmetalcladbusbarchambermadeof 1.6mmthickCRCAsheetwith4stripcopperbusbarsof following capacity and length, complete with all accessories, including earthing the body etc. as required. 200 amps x 450mm long
Providing and fixing round/ hexagonal fan box (125 mm. dia) depth 75mm. (max) with 12 mm. dia steel bar hook, 1.6 mm. thiuck MS sheet cover, in RCC slab etc. as required
Supplyingandfixingmetalboxof followingsizes(nominal size)inrecesswithsuitablesizephenoliclaminatedsheet cover in front including painting etc as required. 75 mm X 75 mm X 60 mm deep
100 mm X 100 mm X 60 mm deep
150 mm X 75 mm X 60 mm deep
180 mm X 100 mm X 60 mm deep
200 mm X 300 mm X 60 mm deep
Supplying, instaling, testing and commissioning of following sizes ceiling fan with resistance type regulqator, i/c wiring the down fods of standard length up to 30 cm. with 1.5 sq. mm. FR PVC insulated, copper conductor, sinle core cable, earthing etc. complete as required. 1200 mm. sweep
Supplying, installation, testing and commissioning of following T-5 fluorescent fitting (luminaries) complete with electronic ballast but without fluorescent lamp, on ceiling/ wall surface, earthing the fitting etc. as required. Single box type with decorative end caps
Supplying, fixing, testingandcommissioningof following 230/250volts fluorescent lamp(tube) inexisting lighting luminaries as required. 4' x 28 watt (T-5)
Supplying, fixing, testingandcommissioningof following LEDlampswithinbuiltelectronicdriverheatsinkandall other accessories in existing holder/ luminaries as requiredandfurnishing2YrsGuaranteecertificatefrom manufacturer. 9 Watt
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 5 KV surge protection on pole bracket complete as required and furnishing 2 Yrs Guarantee certificate from manufacturer. 40-45 watt
Batten/ angle holder
Ceiling rose 3 pin 5 amp
Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ concealed, steel/ PVC conduit/ PVC casing caping as required. 3x6 sq.mm
Supply of swaged steel tubular pole as per IS 2713 with base plate of size 300x300x6mm welded at bottom, necessary hole for cable entry and earthing stud welded at specified height including painting with one coat of red oxide zinc chromate primer. Designation 410 SP-35 height 9.50 metre
Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as required.
Supplying and fixing following dia HDPE pipe PE-80 Grade (8kg/sqcm) in single length in the suction/ delivery line of water supply pump etc. as required.
Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as required 3x2.5 sq. mm
Supply, installation, testing and commissioning of 1-3 HP 1 phase submersible motor starter cum control wall/ floor mounted type made out of not less than 1.6 mm thick MS sheet and comprising of following panel mounting switchgears there in including connection inter- connection etc. as required. a) Phase indicating lamps with fuses and toggle switches 1 set b) 1/2/3 HP 1 phase DOL starter with over load and no volt relay 1 No c) 25 A "C" curve DPMCB 1 No d) Voltmeter 0-250 V 1 set e) Ammeter 0-10 A 1 set
Wiring for light/ fan/ exhaust fan / call bell point with 1.5 sqmm FR PVC insulated stranded copper conductor single core cable in concealed PVC conduit, with 5 amp modular switch, modular base and cover plate, suitable size G.I. box and earthing the point with same size cable as required. Short Point
Medium point
Long point
Extra for providing and fixing light plug point on board in concealed PVC conduit point wiring with modular type 3 pin 5 amp socket outlet and 5 amp switch including cost of base and cover plate and G. I. box etc. as required.
Wiring for light plug point with 2x2.5 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required. Medium Point
Wiring for power plug point with 2x4 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required.Short Point
Wiring for power plug point with 2x4 sq mm FR PVC insulated stranded copper conductor cable in concealed PVC conduit along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size cable etc. as required.Medium Point
Long Point
Wiring for circuit / sub main wiring allong witrh earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in concealed steel conduit as required. 3x2.5 sq. mm in 20 mm conduit
6x2.5 sq. mm in 20 mm conduit.
Earhting with copper earth plate 600 mm X 600 mm X 3 mm thkick i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe.
Supplying and laying 8 SWG copper wire at 0.50 meter below ground level for conductor earth electrode, i/c solding etc. as required.
Providingandfixingmetalclad,SP&Nswitchfuseunit(re wirable), 230/250 volts, withporcelain re-wireble fuses including drilling holes on the board, connections, earthingthebodyetc. as required. (Thimbelingshall be paid separately). 32 amps
Supplying and fixing on surface/ recess following way, 240 volts SP&N MCB distribution board of sheet steel phosphatized and powder painted complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Single door
Supplyingand fixingonsurface/ recess followingway, 240voltsSP&NMCBdistributionboardof sheet steel phosphatizedandpowder paintedcompletewith tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way, Single door
Supplying and fixing DPMCB, 240 volts, 'C' curve, suitablefor lightingandother loads intheexistingMCB DB complete with connections, testing and commissioning etc. as required. 6 amps to 32 amps
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps.
Supplyingandfixingmetalboxof followingsizes(nominal size)inrecesswithsuitablesizephenoliclaminatedsheet cover in front including painting etc as required. 75 mm X 75 mm X 60 mm deep
100 mm X 100 mm X 60 mm deep
Supplying and fixing metal box of following sizes (nominal size) in recess with suitable size phenolic laminated sheet cover in front including painting etc as required.200 mm X 125 mm X 60 mm deep
Supplying, instaling, testing and commissioning of following sizes ceiling fan with resistance type regulqator, i/c wiring the down fods of standard length up to 30 cm. with 1.5 sq. mm. FR PVC insulated, copper conductor, sinle core cable, earthing etc. complete as required. 1200 mm. sweep
Supplying, installation, testing and commissioning of following T-5 fluorescent fitting (luminaries) complete with electronic ballast but without fluorescent lamp, on ceiling/ wall surface, earthing the fitting etc. as required. Single box type with decorative end caps
Supplying, fixing, testingandcommissioningof following 230/250volts fluorescent lamp(tube) inexisting lighting luminaries as required. 4' x 28 watt (T-5)
Supplying, fixing, testingandcommissioningof following LEDlampswithinbuiltelectronicdriverheatsinkandall other accessories in existing holder/ luminaries as requiredandfurnishing2YrsGuaranteecertificatefrom manufacturer. 9 Watt
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 5 KV surge protection on pole bracket complete as required and furnishing 2 Yrs Guarantee certificate from manufacturer. 40-45 watt
Supplyingand laying following size sone number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminiumconductorpowercableof1.1KVgradedirect in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 4 x 10 sq. mm
Supplying and hanging following sizes one number PVC insulated/ XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on GI bearer wire (binded at every metre) including cost of bearer wire complete as required. 4 x 10 sq. mm. on 8 SWG GI bearer wire
Batten/ angle holder
Ceiling rose 3 pin 5 amp
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as required.300 mm sweep
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).
Exvavation for all types of foundations,trenches and drains or for any othere purpose including disposal of excavated stuff upto 50m lead and a lift upto 1.50 M. (at least 5.00 M. away from the excavated area) including dressing and leveling of pits. In all types of soil.
Exvavation for all types of foundations,trenches and drains or for any othere purpose including disposal of excavated stuff upto 50m lead and a lift upto 1.50 M. (at least 5.00 M. away from the excavated area) including dressing and leveling of pits. In ordinary rocks
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size).
1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete.Thrermo-mechanically treated bars.
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Up to 4.00 M. Height
Above 4.00 M. to 8.00 M.
Above 8.00 M. to 12.00 M.
Providing and fixing formwork i/c centering, shuttering, strutting, staging, propping bracing etc complete and including its removal all levels for :Foundations, footing, base of columns and plinth beam in any shape and size.
Columns-rectangular or square in shape. (i) Up to 4m height
Above 4.00 M. to 5.00 M.
Above 5.00 M. to 6.00 M.
Above 6.00 M. to 7.00 M.
Above 7.00 M. to 8.00 M.
Above 8.00 M. to 9.00 M.
Wall of any thickness including attached pilasters, buttresses etc.
Window sills, anchor blocks, string course, bends, copings, bed plates and like.Extra for additional height every 1m or part thereof where height of staging for form work exceeds 4.0 metre with adequate bracing, propping etc at all levels, for suspended floor, roof, landing, beam and balcony. (only plan area is to be measured):
Above 6.00 M. to 7.00 M.
Above 7.00 M. to 8.00 M.
Above 8.00 M. to 9.00 M.
Above 9.00 M. to 10.00 M.
(D) weather shade chhajja cornies and moulding.
Suspended floor roof access plate form balconies (plain surface)and shelves(cast in situ)
Edge of slab breaks in floorand wall up to 200mm
Beams, lintel, cantilevers & walls.
Above 5.00 M. to6.00 m
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in:Cement Mortar 1:6 (1 Cement : 6 Sand)
Extra for brick work In S/S above plinth & up to floor five level.
Extra for brick work In S/S above 4.00 m & upto 8.00 M
Filling from available stuff (Excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20cm. in depth consolidating each deposited layer by ramming and watering with a lead up to 50M. and lift up to 1.5M.
Providing and filling in plinth with sand/Crusher dust and hard moorum under floor in layers not exceeding 20 Cm. In depth consolidating each deposited layer by ramming & watering including dressing etc complete.
Extra for providing & fixing 4 mm. Thick glass strips in joints of Terrazzo floor/ cement concrete floor & or like. 40 mm. wide
60 mm. Wide
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Cement concrete flooring with cement concrete 1:2:4 concrete (1 cement : 2 course sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 50mm thick
75mm thick
Providing and making 12mm thick cement plaster of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size upto 200x300mm
Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.Size 300x300mm
Providing and laying vitrified floor tiles with double charge/ multi charge printing with water absorption less than 0.5% and conforming to IS : 15622 of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm
Providing and fixing factory made ISI marks steel doors, windows and ventilators side/ top/ centre hung made up of standard rolled steel section conforming to IS 1038:1968 (viz. F7D, F4B, K11 and K12B etc.), joints mitred and flash butt and sash bars tenoned and riveted/ welded with 10 cm long lugs of size 15x3mm embedded in cement concrete block 15x10x10 cms of 1:3:6 (1 cement :3 Coarse sand: 6 graded stone aggregate 20 mm nominal size) or rawl plugs and screws or with bolts and nuts as required including providing and fixing of hinges, pivots, handles, pegs, stays, rolling devices, locking arrangements, spring catch etc., as required complete including applying a priming coat of red oxide zinc chromate primer.
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: For fixed portion
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading.With float glass panes of 6 mm thickness
Providing and fixing 2mm thick semi transparent polycarbonate profile roofing sheet of approved make and colour to make any normal roofing / covering and fixing as per manufacture specification at spacing not more than 1.2 m centre to centre with EPDM gasket and silicon sealant fixed with self drilling stainless steel screws all complete as per direction of Engineer-in-Charge
Supplying and fixing rolling shutter of approved makes made of M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft, with brackets, side guides and arrangements for inside and out side locking with push and pull arrangement complete but excluding the cost of top cover and spring.80 x 1.25 mm. M.S. laths
Extra for providing grilled rolling shutter manufactured out of 8 mm dia. M.S. bar instead of laths as per approved design (area of grill provided, only to be measured).
Providing and fixing 27.5cm. long wire spring for rolling shutters.
Providing and fixing M.S. sheet top cover for rolling shutter.0.90 mm. thick
Providing andfixing ball bearing for rolling shutters.
Providing and fixing M.S. frames of doors, windows and ventilators joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.In Angle-iron frames
Providing and fixing in position welded steel wire fabric to concrete/ wooden/ angle iron posts including securing and screwing with G.I. tying wire, G.I. stapples, G.I.U-nails or steel pins etc., complete. Aperture 50x25mm
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.30 mm. thick (single leaf)
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 300mm
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 250 x10mm
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 250 x10mm
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete. 150 mm
Providing and fixing stainless steel hanging door stopper with necessary stainless steel screws complete. Single
Providing and fixing stainless steel piano hinges with necessary stainless steel screws etc complete. Overall width 25 mm
Providing and fixing factory made PVC door shutters of specified thickness made of styles and rails of a UPVC hollow section of specified size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws.24 mm thick door shutters with styles and rails of size 59x24 mm
Steel work in tubular structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.Electric resistance or induction butt welded tubes Grade-300. Upto 5.00 M. height.
Above 5.00 M. height.
Extra for providing and fixing wind ties of 40 x 6 mm flat iron section.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Crimp curve
Supply and fixing of polymer precoated galvalume profile sheets (PPGL) of approved size, shape and pitch of corrugation, total coated thickness (TCT) 0.60 mm +/- 5%, epoxy primer on both side of the sheet and colour polyester top coat 18-20 microns and 6-7 microns on bottom. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 6mm thick cement plaster of mix:n Cement mortar 1:4 (1 cement : 4 fine sand)
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: Cement Mortar 1:4 (1 cement : 4 coarse sand)
Extra for lining over plaster to imitate stone or concrete block walling.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Painting on new work (two or more coats) to give an even shade with: Aluminium paint
Providing and applying 2mm thick ready mix exterior grade approved make putty (like Birla wall care, Alltek Superfine W/R of (NCL), Asian, ICI, Nerolac, J.K. wall putty) on walls to make the surface smooth and even.
Wall painting with acrylic luxury emulsion (plastic) paint of required shade to give an even shade..On new work (Two or more coats)
Applying one coat of cement primer on wall surface (applied @ 0.80 litrs/10 sqm) complete.
Painting exterior surface with ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Painting on new work (two or more coats) to give an even shade with: Satin synthetic enamel paint
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge upto 90 metre depth below ground level.
Rocky strata including 150 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, ISI marked G.I. casing pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part-1&Part-2) 1992 with IVth revision (Up-to-date amendments), of reputed & approved make, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge.
Rocky strata including 150 mm dia.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of:
Providing and fixing water closet squatting pan (Indian type W.C. pan ), 100mm sand cast Iron P or S trap, 10 litre low level P.V.C. flushing cistern (same colour) conforming to IS : 7231, with flush bend and other fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Long pattern W.C. pan of size 580 mm
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 110 mm
(d) Vent covel 75 mm
(e) P trap
(f) Nahani trap 110x75mm
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 75 mm dia pipe.
110 mm dia pipe.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 100 mm diameter S.W. pipe
Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 20.3.1 100x100 mm size P type
Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass complete: Flat back type urinal of size 460x380x250mm
Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : White Size 550x450 mm
Providing and fixing one piece construction white vitreous china squatting plate urinal with an integral rim longitudinal flushing pipe.
Providing and constructing brick masonry chamber for underground pipe and and bends with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 455x610 mm and 45 cm deep for single pipe line :
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink without drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 345x445 mm bowl depth 200 mm.
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia
Providing and fixing PVC waste coupling in wash basin/ sink. 40 mm
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Bib cock (400 grams)
Angle valve for basin mixer and geyser points (450 grams)
Long nose bib cock (500 grams)
Shower rose (revolving type) (150mm)
Stop cock (concealed) (600 grams)
Providing and fixing stainless steel drain jali of approved make/quality.
Providing and fixing brass/ gun metal gate valve with C.I. wheel of approved quality (screwed end): 40 mm nominal bore
25 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
15 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chases and making good the walls etc., 25 mm nominal outer dia .Pipes.
20 mm nominal outer dia .Pipes
15 mm nominal outer dia .Pipes
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :White pedestal type
Providing and fixing vitreous china water closet squatting pan (Indian type) including cutting and making good the walls and floors wherever required:White Orissa pattern W.C. pan of size 580x440 mm
Providing and fixing vitreous china 10 litre (full flush) capacity controlled flush low level cistern with all fittings complete.White
Providing and fixing white vitreous china urinal basin as per IS : 2556 complete: Flat back type urinal of size 460x380x250mm
`Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required :White size 450x325 mm
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink without drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required :345x445 mm bowl depth 200 mm.
Providing and fixing 15 mm nominal bore uplasticised PVC connection pipe with C.P brass nuts collar and PVC bush of approved quality and colour: 45 CM length
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 110 mm dia pipe.
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete.75 mm dia pipe.
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 110 mm
(B) "P" trap 110mmx110mm long
(e) Nahani trap
(f) Vent covel (a) 110mm.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.INTERNAL WORK - EXPOSED ON WALL 25 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.INTERNAL WORK - EXPOSED ON WALL15 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.CONCEALED WORK including cutting chases and making good the walls etc.,15 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.CONCEALED WORK including cutting chases and making good the walls etc.,25 mm nominal outer dia .Pipes.
Providing and fixing gun metal non- return valve (vertical type) of approved quality (screwed end) : 25 mm nominal bore
Providing and fixing stainless steel drain jali of approved make/quality.
Providing and fixing 15 mm nominal bore Brass bib/stop cock of approved quality: Bib cock (350 grams)
Stop cock (600 grams)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required:Shower rose (revolving type) (150mm)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required:Long nose bib cock (500 grams)
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required:Health foscet (hand jet) with flexible connection pipe (for WC)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Excavation for all types of foundations,trenches and drains or for any othere purpose including disposal of excavated stuff upto 50m lead and a lift upto 1.50 M. (at least 5.00 M. away from the excavated area) including dressing and leveling of pits. In all types of soil.
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. In ordinary Rock
1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete. a) Thrermo-mechanically
Providing and fixing formwork i/c centering, shuttering, strutting, staging, propping bracing etc complete and including its removal all levels for :-(A) Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
(b) Columns-rectangular or square in shape. (i) Up to 4m height
Window sill,anchore string course bend coping bed plate and like(i) Up to 4.00 M. height from P.L.
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Providing and laying mechanically mixed reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in: Cement Mortar 1:6 (1 Cement : 6 Sand)
(B) Extra for brick work In S/S above plinth & up to floor five level.
Providing and fixing M.S. frames of doors, windows and ventilators joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (a) In Angle-iron frames
Providing and making 6mm thick cement plaster of mix:n Cement mortar 1:4 (1 cement : 4 fine sand)
Providing and making 12mm thick cement plaster of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix:In Cement Mortar 1:6 (1 cement : 6 fine sand)
Filling from available stuff (Excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20cm. in depth consolidating each deposited layer by ramming and watering with a lead up to 50M. and lift up to 1.5M.
Extra for lining over plaster to imitate stone or concrete block walling.
Painting exterior surface with ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with:On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing and fixing in position G.I. barbed wire (93.8gram/m) to concrete/ wooden/ angle iron posts (straight or diagonal) including securing and screwing with G.I. tying wire, G.I. stapples, G.I.U-nails or steel pins etc., complete(Cost of posts, struts to be paid for separately)
Providing and fixing concertina coil fencing with required dia 610 mm (having 50 nos. round per 6 metre length) up to 3m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart tied with G.I. staples and G.I. clips to retain horizontal including necessary bolts or G.I. barbed wire tied to angle iron all complete as per direction of Engineer-incharge with reinforced barbed tape (R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Providing and fixing in position door shutter made of square/ rectangular hollow steel tube of approved size joint mitred, welded frame with two Nos. intermediate rails, 200mm wide lock rail made of 1.6mm thick M.S. sheet welded to intermediate rail, M.S. grill of approved pattern made of M.S. flat or square or round bars welded to frames and provided M.S. butt hinges, all necessary fitting and finished by filling putty including applying a priming coat of red oxide zinc chromate primer all complete. (To be used in safety door shutters in buildings)
Painting on new work (two or more coats) to give an even shade with: (a) Aluminium Paint
Excavation for all types of foundations,trenches and drains or for any othere purpose including disposal of excavated stuff upto 50m lead and a lift upto 1.50 M. (at least 5.00 M. away from the excavated area) including dressing and leveling of pits. In all types of soil.
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. In ordinary Rock
1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in: Cement Mortar 1:6 (1 Cement : 6 Sand)
(B) Extra for brick work In S/S above plinth & up to floor five level.
Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including formwork.
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete. a) Thrermo-mechanically
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Providing and laying mechanically mixed reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Providing and fixing formwork i/c centering, shuttering, strutting, staging, propping bracing etc complete and including its removal all levels for :-(A) Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
(b) Columns-rectangular or square in shape. (i) Up to 4m height
(C) Beams, lintel, cantilevers & walls.(i) Up to 4.00 M. height from P.L.
(D) weather shade chhajja cornies and moulding.
(E) Suspended floor roof access plate form balconies (plain surface)and shelves (cast in situ)
(F) Edge of slab breaks in floorand wall up to 200mm
Stair cases of all types excluding spiral and folded plate type, including risers and landings.Up to 4.00 M. height from P.L.
(C) Window sill,anchore string course bend coping bed plate and like (i) Up to 4.00 M. height from P.L.
(G) Stair cases of all types excluding spiral and folded plate type, including risers and landings (a) Up to 4.00 M. height from P.L.
Providing and filling in plinth with sand/Crusher dust and hard moorum under floor in layers not exceeding 20 Cm. In depth consolidating each deposited layer by ramming & watering including dressing etc complete.
Providing and fixing M.S. frames of doors, windows and ventilators joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (a) In Angle-iron frames
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Providing and fixing float glass panes with steel glazing clips and special metal sash putty of approved make in steel doors, windows, ventilators: 4 mm. Thick
Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.50mm thick
Extra for providing and fixing 4mm thick glass strip in joints of Terrazo floor/ cement concrete floor or like. 40 mm wide
Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete.Size 300x300mm
Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size upto 200x300mm
Providing and laying vitrified floor tiles with double charge/ multi charge printing with water absorption less than 0.5% and conforming to IS : 15622 of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm
25mm thick Local RAJIM/ Red Flag stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid over & jointed with grey cement slurry mixed with pigments to match the shade of the stone i/c grinding, rubbing and polishing.
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.30 mm. thick (single leaf)
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 300mm
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 200 x10mm
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete. 150 mm
Providing and fixing stainless steel hanging door stopper with necessary stainless steel screws complete. Single
Providing and fixing factory made PVC door shutters of specified thickness made of styles and rails of a UPVC hollow section of specified size 59x24 mm and wall thickness 2 mm ± 0.2 mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws.24 mm thick door shutters with styles and rails of size 59x24 mm
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1: 1:5: 3 (1 cement : 1:3 coarse sand : 3 graded stone aggregate 40mm nominal size).
Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:4 (1 cement : 4 fine sand)
Extra for lining over plaster to imitate stone or concrete block walling.
Neat cement punning.
Wall painting with acrylic luxury emulsion (plastic) paint of required shade to give an even shade. On new work (two or more coats)
Applying one coat of cement primer on wall surface (applied @ 0.80 litrs/10 sqm) complete.
Painting exterior surface with ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with: On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: For fixed portion
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: Cement Mortar 1:4 (1 cement : 4 coarse sand)
Providing and applying 2mm thick ready mix exterior grade approved make putty (like Birla wall care, Alltek Superfine W/R of (NCL), Asian, ICI, Nerolac, J.K. wall putty) on walls to make the surface smooth and even.
Painting on new work (two or more coats) to give an even shade with: Satin synthetic enamel paint
Painting on new work (two or more coats) to give an even shade with: (a) Aluminium Paint
Providing and fixing stainless steel door latch with 12mm rod, 2.5mm thick flap, necessary stainless steel screws etc complete. 250mm
Providing and fixing stainless steel piano hinges with necessary stainless steel screws etc complete. Overall width 25 mm
Excavation for all types of foundations,trenches and drains or for any othere purpose including disposal of excavated stuff upto 50m lead and a lift upto 1.50 M. (at least 5.00 M. away from the excavated area) including dressing and leveling of pits. In all types of soil.
1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in: Cement Mortar 1:6 (1 Cement : 6 Sand)
(B) Extra for brick work In S/S above plinth & up to floor five level.
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete. a) Thrermo-mechanically
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. (a) 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Providing and laying mechanically mixed reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Extra for precast PCC/ RCC work of any mix including form work, hoisting and fixing in Cement Mortar. 1:2 (1 Cement : 2 coarse sand) and finishing with cement plaster in Cement Mortar 1:3 (1 Cement : 3 coarse sand) but excluding reinforcement.
Providing and fixing formwork i/c centering, shuttering, strutting, staging, propping bracing etc complete and including its removal all levels for :-(A) Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
(b) Columns-rectangular or square in shape. (i) Up to 4m height
(C) Beams, lintel, cantilevers & walls.(i) Up to 4.00 M. height from P.L.
(D) weather shade chhajja cornies and moulding.
(E) Suspended floor roof access plate form balconies (plain surface)and shelves (cast in situ)
(F) Edge of slab breaks in floorand wall up to 200mm
(G) Stair cases of all types excluding spiral and folded plate type, including risers and landings (a) Up to 4.00 M. height from P.L.
Providing and filling in plinth with sand/Crusher dust and hard moorum under floor in layers not exceeding 20 Cm. In depth consolidating each deposited layer by ramming & watering including dressing etc complete.
Providing and fixing M.S. frames of doors, windows and ventilators joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of grade M-10 or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (a) In Angle-iron frames
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer.
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
Extra for powder coated (minimum 50 micron) aluminium sections instead of anodized.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 6 mm thickness
Cement concrete flooring with cement concrete 1:2:4 concrete (1 cement : 2 course sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.(a) 50mm thick
Extra for providing & fixing 4 mm. Thick glass strips in joints of Terrazzo floor/ cement concrete floor & or like. (a) 40 mm. wide
Providing and laying ceramic glazed floor tiles conforming to IS : 15622 of approved size, make, colour, shade laid on 20 mm thick Cement Mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement mixed with matching pigment etc., complete. (A) Size 300x300mm
Providing and fixing ceramic glazed wall tiles conforming to IS : 15622 of approved make, colours, shades and size on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. (A) Size up to 200x300mm
Providing and laying vitrified floor tiles with double charge/ multi charge printing with water absorption less than 0.5% and conforming to IS : 15622 of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.30 mm. thick (single leaf)
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 300mm
Providing and fixing aluminium sliding door bolts with 16mm rod, necessary nickle plated iron nuts bolts and screws etc complete. 250x16mm.
Providing and fixing aluminium tower bolts (Barrel type) with necessary nickle plated iron screws etc complete. 100 x10mm
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 150 x10mm
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete. 125 mm
Providing and fixing stainless steel hanging door stopper with necessary stainless steel screws complete. Single
Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:4 (1 cement : 4 fine sand)
Providing and making moulded mortar band in cement mortar 1:4 (1cement : 4 fine sand) per cm width: 12 mm thick
Extra for lining over plaster to imitate stone or concrete block walling.
Neat cement punning.
Providing and applying 2mm thick ready mix exterior grade approved make putty (like Birla wall care, Alltek Superfine W/R of (NCL), Asian, ICI, Nerolac, J.K. wall putty) on walls to make the surface smooth and even.
Wall painting with acrylic premium emulsion (plastic) paint of required shade to give an even shade. On new work (two or more coats)
Applying one coat of cement primer on wall surface (applied @ 0.80 litrs/10 sqm) complete.
Painting exterior surface with ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with:On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Painting exterior surface with ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with:On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. In all types of soils.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)
Brick work with modular fly-ash lime bricks (FALG Bricks) confirming to IS:12894-2002 of class designation 40 in foundation and plinth in: Cement Mortar 1:6 (1 Cement : 6 Sand)
(B) Extra for brick work In S/S above plinth & up to floor five level.
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete.Thermo-Mechanically treated bars FE 415
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Providing and laying mechanically mixed reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. Foundations, footing, base of columns and plinth beam in any shape and size
Columns-rectangular or square in shape.Up to 4m height
Beams, lintel, cantilevers & walls.Up to 4.00 M. height from P.L.
(E) Suspended floor roof access plate form balconies (plain surface)and shelves (cast in situ)
Edge of slab breaks in floorand wall up to 200mm
(C) Window sill,anchore string course bend coping bed plate and like (i) Up to 4.00 M. height from P.L.
(G) Stair cases of all types excluding spiral and folded plate type, including risers and landings (a) Up to 4.00 M. height from P.L.
Providing and filling in plinth with sand/Crusher dust and hard moorum under floor in layers not exceeding 20 Cm. In depth consolidating each deposited layer by ramming & watering including dressing etc complete.
Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement.50mm thick
Extra for providing and fixing 4mm thick glass strip in joints of Terrazo floor/ cement concrete floor or like. 40 mm wide
Steel work in tubular structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.Electric resistance or induction butt welded tubes Grade-300. Upto 5.00 M. height.
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.30 mm. thick (single leaf)
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 300mm
Providing and fixing stainless steel sliding door bolts with 16mm rod, 2.5mm thick flap, necessary stainless steel nuts bolts and screws etc complete. 300mm
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 250 x10mm
Providing and fixing stainless steel door handles having flap thickness 2.5mm, necessary stainless steel screws etc complete. 150 mm
Providing and fixing stainless steel hanging door stopper with necessary stainless steel screws complete. Single
Providing and fixing stainless steel tower bolts (Barrel type) with necessary stainless steel screws etc complete. 300mm
Providing and fixing stainless steel piano hinges with necessary stainless steel screws etc complete. Overall width 25 mm
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Supply and fixing of polymer precoated galvalume profile sheets (PPGL) of approved size, shape and pitch of corrugation, total coated thickness (TCT) 0.60 mm +/- 5%, epoxy primer on both side of the sheet and colour polyester top coat 18-20 microns and 6-7 microns on bottom. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters
Neat cement punning.
Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:4 (1 cement : 4 fine sand)
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)
Applying one coat of cement primer on wall surface (applied @ 0.80 litrs/10 sqm) complete.
Providing and applying 2mm thick ready mix exterior grade approved make putty (like Birla wall care, Alltek Superfine W/R of (NCL), Asian, ICI, Nerolac, J.K. wall putty) on walls to make the surface smooth and even.
Wall painting with acrylic luxury emulsion (plastic) paint of required shade to give an even shade..On new work (Two or more coats)
Painting on new work (two or more coats) to give an even shade with: (a) Aluminium Paint
Painting on new work (two or more coats) to give an even shade with: Satin synthetic enamel paint
Providing and laying cement concrete for plain concrete/ reinforced concrete i/c form work, shuttering complete in as per drawings and specifications.( For Village roads) (a) P.C.C. M-10
Plain cement concrete as per drawings and Technical specifications.( For Village roads) (a) P.C.C. M-20
Providing and laying Reinforced Cement Concrete pipe NP 3/ Prestressed concrete pie on first class bedding (Laying Reinforced Cement concrete pipe NP3/ prestressed concrete pipe for culverts including fixing coller with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works backfilling ; concrete and masonry works in head walls and parapets.) (a) 600 mm dia
Construction of RCC open drain Construction of RCC open drain with 1.00 M Or 0.80( inside dimension) and average depth from inlet to Outlet 1.0 m. Or 0.80 m(maintaing slop as per site condition ) with 150 mm thick RCC M-25 walls, 150 mm thick RCC M-25 bottom slab ,over 100 mm thick (Av.) leveling course in PCC M-15 including excavation , dressing of sides and bottom, provision of HYSD reinforcement consisting 10 mm dia horizontal bars @ 150 mm c/c and U-shaped 10 mm dia vertical bars @ 150 mm c/c including cutting , bending and binding wire, placing in position , providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications.(B) 0.60 mm width X 0.60 mm av. Depth
Granular Sub-base as per Table:- 400-1 Construction of granular sub base by providing graded Mateial, , Carriage of mixed Material to work site spreading in uniform layers with motor grader on on perpared surface watering , rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 Plant mix method ( with Mechanically crushed stone only) (A) For Lower Sub-base with (i) Grading-V Material
Wet Mix Macadam (Providing laying, spreading and compacting graded stone aggregate to wet mix machadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site laying in uniform layers with paver in sub -base / base course on well prepared surface and compacting with vibtatory roller to achieve the desired density as per clause
Dry Lean Cement Concrete Sub-base Construction of dry Lean Cement Concrete Sub-base as per IRC:SP-49 over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601.)
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement as per IRC:58 over a prepared sub-base, coarse and fine aggregate conforming to IS:383 and graded as per table 600-3 mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per clause 602.) (A) Using Slip Form Paver (a) With Cement concrete grade M-40 and minimum cement content @ 400 kg/cum.
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. In all types of soils.
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. In ordinary Rock
Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete.Thermo-Mechanically treated bars FE 415
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level. Foundations, footing, base of columns and plinth beam in any shape and size
Providing and filling in plinth with sand/Crusher dust and hard moorum under floor in layers not exceeding 20 Cm. In depth consolidating each deposited layer by ramming & watering including dressing etc complete.
Steel work in tubular structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.Electric resistance or induction butt welded tubes Grade-300. Upto 5.00 M. height.
Supply and fixing of precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/- 5% total coated thickness (TCT), Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : Crimp curve
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Painting exterior surface with ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with:On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Demolishing R.C.C. work including stacking of steel bars and disposal of unserviceable material within 50 metre lead.
Dismantling steel work in built-up section in angles, channels, flats Isection and T-section including all gusset plates, bolts, nuts, cutting rivets, welding etc., including dismembering and stacking within 50 metres lead.
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. In all types of soils.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:4:8 (1 cement : 4 course sand : 8 graded stone aggregate 40 mm. Nominal size)
Providing and placing in position reinforcement for R.C.C. work including straightenigng, cutting, bending, binding etc. complete as per drawings including cost of binding wire and including all complete.Thermo-Mechanically treated bars FE 415
Providing and laying nominal mix reinforced cement concrete with crushed stone aggregate using concrete mixer in all works up to floor five level excluding cost of form work. 1:1.5:3 (1 cement : 1.5 course sand : 3 graded stone aggregate 20 mm. Nominal size)
Steel work in tubular structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer.Electric resistance or induction butt welded tubes Grade-300. Upto 5.00 M. height.
Columns-rectangular or square in shape.Up to 4m height
Painting exterior surface with ACRYLIC SMOOTH exterior paint of required shade as per manufacturer's specifications to give protective and decorative finish including cleaning washing of surface etc. complete with:On new work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
UOM Name
Percentage
Per mile
Per Diem Rate
MAN DAYS
Siemens Per meter
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.02 MB
1744388103754035539_187351_Group No 09 Bhatapara 14400 MT.docx
NIT • 6.53 MB
3475892072704640745_187351_Group No 9 Bhatapara 14400 MT.xlsx
BOQ • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .