| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC 0 RUPSINGH JOTE BAGDOGRA DARJEELING WEST BENGAL 734014 UDYAM WB 06 0007631 | DARJEELING | WEST BENGAL | 734014 | L1 | Accepted-AOC BIDDER IS L1. RECOMMENDED BY TC AND APPROVED BY COMPETENT AUTHORITY. | |
| 2 | L2₹3.4 L+₹4,547 (1.37%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1. BID REJECTED. | |
| 3 | Rejected-Technical TETULMURI DHANBAD 00 00 TETULMURI SIJUA DHANBAD TETULMURI DHANBAD 00 00 TETULMURI SIJUA DHANBAD DHANBAD 828121 JHARKHAND INDIA | DHANBAD | DHANBAD | JHARKHAND | 828121 | - | Rejected-Technical Documents examined by the TC and found NOT as per NIT. BID REJECTED FOR OPENING OF COVER II. |
| Sl No | Description | Qty | Unit | M/S BHARDWAJ ENTERPRISES L1 | M/S OM ENTERPRISES L2 |
|---|---|---|---|---|---|
| 1.01 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (Group A) | 60 | No. | 455 ₹27,300 Lowest | 460 ₹27,600 |
| 1.02 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required (2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire) | 200 | Meters | 270 ₹54,000 Lowest | 275 ₹55,000 |
| 1.03 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. | 125 | No. | 791 ₹98,875 Lowest | 800 ₹1,00,000 |
| 1.04 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). | 50 | Each | 284 ₹14,200 Lowest | 295 ₹14,750 |
| 1.05 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. | 25 | Each | 484 ₹12,100 Lowest | 489 ₹12,225 |
| 1.06 | Supply and providing of aesthetic recess mounted ceiling lights 15W suitable to be fitted at ceiling cutout | 40 | No. | 918.08 ₹36,723.2 Lowest | 920 ₹36,800 |
| 1.07 | Supply and providing of 26W/ 30W LED lights | 14 | No. | 650 ₹9,100 | 648 ₹9,072 Lowest |
| 1.08 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 15 | Each | 313 ₹4,695 Lowest | 315 ₹4,725 |
| 1.09 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required. | 15 | No. | 215 ₹3,225 Lowest | 218 ₹3,270 |
| 1.10 | Supplying and drawing 2x2.5 sq mm FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | 100 | Meters | 83 ₹8,300 Lowest | 85 ₹8,500 |
Tender Value
₹3.9 L
EMD Value
₹4,900
Closing Date
10 Mar 2025, 9:00 amClosed
PE EnM
PE EnM PO OFFICE BOKARO COLLIERY
Electrical repair and maintenance of four nos. Community Centres located at Gandhinagar, 3 no., Sunday Bazaar and Kashmir Colony in respect of Bokaro Colliery, BNK Area
2025_CCL_330586_5
CCL/BnK/Bokaro/EnM/24-25/11
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
Bokaro colliery
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,900
24 Dec 2025
27 Feb 2025
11 Mar 2025
28 Feb 2025
10 Mar 2025
28 Feb 2025
28 Feb 2025 - 6 Mar 2025
Amount
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (Group A)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required (2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supply and providing of aesthetic recess mounted ceiling lights 15W suitable to be fitted at ceiling cutout
Supply and providing of 26W/ 30W LED lights
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required.
Supplying and drawing 2x2.5 sq mm FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing 2 x 4 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 Amps TP&N
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.
Painting of ceiling fan in installed position with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning of surface with detergent etc as required.
Supplying and fixing of 32mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Total impact of GST for the purpose of CTC
M/S OM ENTERPRISES (BID ID -1135894)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .