Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹17.2 LAccepted-AOC B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | ₹17.2 L | L-1 | Accepted-AOC BEING THE LOWEST BIDDER |
| 2 | L-2₹17.9 L+₹74,891.94 (4.36%)Rejected-Finance 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | ₹17.9 L+₹74,891.94 (4.36%) | L-2 | Rejected-Finance Second lowest bidder |
| 3 | L-3₹19.4 L+₹2.2 L (12.6%)Rejected-Finance 97 19 JWALA HERI PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | ₹19.4 L+₹2.2 L (12.6%) | L-3 | Rejected-Finance Third lowest bidder |
| 4 | L-4₹19.4 L+₹2.2 L (12.9%)Rejected-Finance | ₹19.4 L+₹2.2 L (12.9%) | L-4 | Rejected-Finance Fourth lowest bidder |
| 5 | L-5₹20.6 L+₹3.4 L (19.9%)Rejected-Finance A 86 MANISH MARG NEMI NAGAR VAISHALI NAGAR JAIPUR JAIPUR JAIPUR RAJASTHAN 302021 | JAIPUR | RAJASTHAN | 302021 | ₹20.6 L+₹3.4 L (19.9%) | L-5 | Rejected-Finance Fifth lowest bidder |
Tender Value
₹27.1 L
EMD Value
₹54,216
Closing Date
3 Apr 2024, 6:00 pmClosed
ARUN KUMAR
AAI NATS Complex, T-2 Road, IGI Airport, New Delhi
Replacement of Old Split and Tower type AC units at INRES Centre Nangloi, New Delhi
2024_AAI_190462_1
NGL-REPL-AC
Open Tender
Electrical Works
Item Rate
90 days
AAI NATS Complex, T-2 Road, IGI Airport
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,180
₹54,216
3 May 2024
13 Mar 2024
5 Apr 2024
13 Mar 2024
3 Apr 2024
13 Mar 2024
13 Mar 2024 - 18 Mar 2024
Amount
Supply of 5 star rated Split type Airconditioners of 1.5 TR capacity fitted with hermetically sealed compressors operating on refrigerant R-32/ R-410A confirming to IS:1391 (part-2)/92 (except power consumption norms) suitable for operation on 230V, Single Phase, 50 HZ AC supply as per site requirement & capable of performing following functions (as per approved make list Mitshubishi, Haier, Carrier, Samsung, Voltas, Daikin, Bluestar, LG, Hitachi (Johnson), Havells) :- a) Cooling b) Dehumidifying c) Air Circulating d) Filtering
Supply of 5 star rated Split type Airconditioners of 2.0 TR capacity fitted with hermetically sealed compressors operating on refrigerant R-32/ R-410A confirming to IS:1391 (part-2)/92 (except power consumption norms) suitable for operation on 230V, Single Phase, 50 HZ AC supply as per site requirement & capable of performing following functions (as per approved make list Mitshubishi, Haier, Carrier, Samsung, Voltas, Daikin, Bluestar, LG, Hitachi (Johnson), Havells) :- a) Cooling b) Dehumidifying c) Air Circulating d) Filtering
Installation, Testing & Commissioning of Split type A/C units i/c fitting of indoor & outdoor unit at their locations, drilling holes in wall using suitable hardwares, ceiling supporting arrangement, leak testing of entire system, charging refrigerant gas in the unit, making good the surface as per requirement of the site.
Supply & Fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole & earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure on surface or in recess with chained metal cover for the socket outlet & complete with connections, testing & commissioning etc. as required.
Supply, Installation, Testing & Commissioning of 5 KVA, Automatic Voltage Stabilizer for Split AC's having operating voltage of 130 Volt to 270 Volt, 50Hz.
Supply & Fixing of 3 Core x 2.5 Sq.mm PVC insulated sheathed copper conductor multi core industrial cable (flexible) of voltage upto 1100 volts as per IS 694:1990 up dated for different capacity A.C. units as per site condition.
Supply & Fixing of 3 Core x 1.5 Sq.mm PVC insulated sheathed copper conductor multi core industrial cable (flexible) of voltage upto 1100 volts as per IS 694:1990 up dated for different capacity A.C. units as per site condition.
Supply & Fixing of 25 mm dia size PVC drain pipe from the respective units i/c elbow & clamping on different surface like wall/ floor etc. i/c sealing the joints with making of openings as per site condition.
Supply & fixing of suitable size Copper Refrigerant piping (Supply & return) with expanded polythene foam insulation tubing covering for Split type 1.5 & 2 TR A/C units. (Measurement of 1 R.Mtr. will include both supply & return Cu. Piping with insulation).
Dismantling of all sizes Split type Airconditioner units (i/c indoor & outdoor units) at various locations/ places i/c dismantling of old Copper Refrigerant piping (supply & return) with expanded polythene foam insulation tubing covering, drain pipe and shifting of all materials to AAI Stores etc. complete as required.
Dismantling of all sizes Tower type Airconditioner units (i/c indoor & outdoor units) at various locations/ places i/c dismantling of existing old Copper Refrigerant piping (supply & return) with expanded polythene foam insulation tubing covering, drain pipe and shifting of all materials to AAI Stores etc. complete as required.
VOLKS ENERGIE PVT LTD
RefAir Technical Services
Pacific Depths
LIFE STYLE INTERIORS
airfreeze
R K Electricals and Refrigeration
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .