Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance H NO 1 24 48 VENKATAPURAM PO TIRUMALGIRI SECUNDERABAD 500 015 | SECUNDERABAD | HYDERABAD | TELANGANA | 500015 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance NO 133 RASHTRAPATHI ROAD SECUNDERABAD 500 003 | SECUNDERABAD | HYDERABAD | TELANGANA | 500003 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
5 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GOLCONDA
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA-08
SPL REPAIRS TO BLDG NO. 30 (OR SINGLE LIVING) AT ARTY CENTRE UNDER GE GOLCONDA
2022_MES_515585_1
8567/E8
Open Tender
Civil Works
Item Rate
180 days
HYDERABAD
As Per Tender
9 documents required · 9 mandatory
₹500
GE GOLCONDA
₹66,000
Yes
7 May 2022
28 Mar 2022
7 May 2022
28 Mar 2022
5 May 2022
20 Apr 2022
60 days
Amount
Dismantling Mangalore pattern roofing tiles with ceiling tiles or slate roofing complete all as specified and directed.
Dismantling battens for tiles, shingles etc of any size including tilting fillets n exc 15 cm centre to centre complete all as specified and directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling of boarding, any description fixed in any position with nails complete all as specified and directed.
M & L pre-painted galvalume aluminium zinc coating GI based corrugated mangalore profile sheet 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed.
M&L pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws as specified
Dismantling wrought iron or mild steel work of any description not otherwise provided for and S & F for Steel work in tubular trusses & vertical post including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade st-240 complete all as specified and directed.
S & F for MS framed structure roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats of Grade Fe 410 -W (Gde- E- 250) quality- A etc complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S & F mild steel screw bolts of 5 to 10 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc. 10 cm but not exc 15cm complete all as specified and directed.
Demolition of brick work masonry, built in cement mortar including all quoins, pillars etc complete all as specified and directed.
M & L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1: 4 complete all as specified and directed.
Taking down cement plaster on wall of any desdriptions incl racking out joints for key scrubbing with water etc. complete all as specified and directed.
M & L for rendering 15mm thick in cement mortor 1:4 (5 mm thick with IWPC @ 3% over a coat of 10 mm thick ) on Brick wall surfaces, finished even and smooth without using extra cement ( IWPC measured and paid separately ) complete all as specified and directed.
M & L for rendering 10mm thick in cement mortor 1:6 on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for two coats of oil bound distemper over a coat of alkali resistant primer on newly plastered surfaces including 1.5mm thick wall care putty on wall including preperation complete all as specified and directed.
M&L for preparing new plastered surfaces and applying Two coats of cement based paint on surfaces of walls complete all as specified and directed.
M&L for complete removal of existing treatment and applying two oil bound distemper over a coat of alkali resistant primer on old surface of walls including 3mm thick wall care putty on wall complete complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of cement base paint on walls surfaces complete all as specified and directed.
M&L Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, plinth Protection, aprons etc Laid, bed-ded and pointed in any mortar, complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description of any position not otherwise specfically provided for as in sunken floors & floor etc complete all as specified and directed.
M&L for 20-25mm thick Machine cut kota stone slab flooring laid over and including cement screed bed in CM(1:6), 20mm thick set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 20-25mm thick Machine cut kota stone slab as in riser of steps, skirting, dado and pillar over and including backing coat in CM(1:4), 10mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L 75mm thick plain cement concrete 1:4:8 Type D2 (using 40mm graded stone aggregate) as in sub base of floors laid in alternative bays including necessary form work complete all as specified and directed.
M & L for 25 mm thick PCC 1:2:4 Type B-0 (using 12.5 mm graded stone aggregate) below tiles for levelling of existing surface complete all as specified and directed.
Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) and removing complete all as specified and directed.
Taking down Chowkats or frames exceeding 1.5 Sq. M but not exceeding 4 Sq. M each (Without taking off shutters from the frame) complete all as specified and directed.
S&F 35 mm thick 2nd class hard wood gauzed and skeleton shutters for doors open rebated and prepared to receive glass, gauge etc., (without sash bars) edges of framing, plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters all as specified in SSR Part-I Section 8 clause 8.24 (a) complete all as specified and as directed.
Dismantling timber scantlings in fillets, rails, post , rafter, purlin etc under 40 Sqcm in section in any position unframed work complete all as specified and directed.
M&L for 2nd Class hardwood plain fillets, square or triangular in section,clean swan, secured with nails or brads croos sectional area exc 13 Sqcm but Not Exc 25 Sqcm.
S&F 175 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
S & F 125 mm long floor door stopper of aluminium alloy body, and tongue, ISI marked, anodised, with hard drawn steel spring, fixed in floor all as specified and as directed.
S & F Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S & F 35 mm thick Second class hard wood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S & F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps and similar small articles confirming to Fe 410-O 0r Fe 310-O complete all as specified and directed.
M & L for plain Cement Concrete Type C1 1:3:6 (using 20 mm graded granite stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates and the like including weathering, slightly rounded complete all as specified and directed.
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges.
S & F 150 mm size mild steel pressed handles, oval type, stove enamelled black complete all as specified and as directed
S & F 125 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt.
S & F for 300 mm mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate.
M & L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and directed.
S & F in repairs stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with wooden beeds complete all as specified and directed.
S&F MS decorative type powder coated curtain rod 25mm dia all as specified in repairs complete all as specified and directed.
S&F MS brackets, decorative type powder coated for curtain rod of 25mm dia complete all as specified and directed.
M&L for providing cement concrete type B0 1:2:4 (12.5mm graded stone aggregate) as in padding and benching & filletting with IWPC (IWPC measured and paid seperately)
M & L for APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) with 10 cm overlap fused uniformly by LPG torch flame laid over including 10mm thick screed bed in CM 1:4 mixed with WPC (IWPC measured and paid separately) finished even and smooth and primed with bituminous primer conforming to IS-3384 applied @ 0.3 ltrs/sqm by torched application and applying one coat of bitumen grade 85/25 @ 1.2 Kg/Sqm finished with one coat of aluminium paint @ 100 ml/sqm including roughening surfaces of old concrete by picking, sweeping cleaning and washing down with water to remove dust, etc. and brushing neat cement slurry @ 3 Kg of cement per square metre including taking down existing water proofing treatment complete all as specified and directed. Note :-Quoted rate is deemed to include for taking down and refixing of existing earth strips in the same position.
Supply only integral water proofing compound.
S&F PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling fixing in opening etc complete all as specified and directed.
S & F in frame Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick(stiles), with 2, 4, or 6 raised paneldesign with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face complete all as specified and directed.
S&F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 and fixed to PVC Doors complete
S&F 125 mm length of aluminium anodised barrel tower bolts of extruded section and fixed.
S&F 125 mm length of extruded aluminium alloy handles, fabricated type, anodised
S&F in repairs Vitreous China squatting pan , "Orissa" pattern size 580 X 440 mm white with intgrel footrest (excluding flushing cistern & flush pipe) including 110mm dia PVC SWR 'P' or 'S' trap complete including provision of cement concrete all as specified and directed.
S&F PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe flush pipe complete all as specified and directed.
S&F in repairs PVC connection 15mm dia, 45 Cms long with brass ferrules on both ends fixed complete all as specified and directed.
S & F in repair 15mm bore Bib taps, chromium plated cast copper alloy but fancy type, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs 15 mm dia fancy type stop valves/ angle cock chromium plated screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Supply & fixing galvanized steel water tubing medium grade complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc of size 15mm dia including taking up or down the existing GI tubing with all fittings complete all as specified and directed.
Supply & fixing galvanized steel water tubing medium grade complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc of size 20mm dia including taking up or down the existing GI tubing with all fittings complete all as specified and directed.
Supply & fixing galvanized steel water tubing medium grade complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc of size 25mm dia including taking up or down the existing GI tubing with all fittings complete all as specified and directed.
S&F for rotational moulded polyethylene water storage tanks double layer (cylindrical vertical with closed top) of 2000 ltrs capacity hoisted and fixed in position including dismantling old tank complete all as specified and directed.
S&F in repair 25 mm Ball brass valves, high pressure, with polythene float and fly-nut screwed for iron pipe or brass ferrule complete all as specified and directed.
S&F in repair 25 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F PVC( SWR ) pipes 110mm dia single socketed , in any lenth with rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches including taking down existing PVC pipe (with all fittings) complete all as specified and directed.
S & F PVC( SWR ) pipes 75mm dia single socketed , in any lenth with rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches including taking down existing PVC pipe (with all fittings) complete all as specified and directed.
S&F PVC (SWR) bends any radius 110mm bore.
S&F PVC (SWR) bends with access door any radius 110mm bore.
S&F PVC(SWR) vent cowl 110mm bore.
S&F PVC (SWR) bends any radious 75 mm dia completee all as specified and directed.
S&F PVC (SWR) junction single (single T) equal or unequal with access door of bore 75mm.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided as cover slabs complete all as specified and directed.
M&L for Pre Cast Cement Concrete 1:2:4 type B1 (using 20 mm graded aggregate) as in Cover slab for manholes etc set in cement mortor 1:4 including use and waste necessary form work (Reinforced shall be measured and paid seprately) complete all as specified and directed.
M&L for MS TMT bars, 10mm dia & over , cut ot length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with wire complete all as specified and directed.
M&L for MS TMT bars,6 to 8mm dia cut ot length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with wire complete all as specified and directed.
Demolition of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off the premises complete all as specified and directed.
M&L non skid coloured ceramic floor tiles 7-8 mm thick (square/ rectanglar ) area of each tile exc 0.06 sqm but n. exc 0.11 sqm, laid ove and including 15mm thick CM screed 1:6, set and jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed.
M&L glazed ceramic coloured tiles 300X200X7mm thick as in dado over back coat 10 mm thick in CM 1:4 and set and jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and directed.
M&L rendering 5 mm thick in CM 1:3 on fair faces of brick surfaces of ceiling finished the surface fair and even and including preparation of newly plastered surfaces and applying three coats of White wash on Ceiling complete all as specified and directed.
S&R in repair 110 mm CP grating complete all as specified and directed.
S&F in repair for PVC waste pipe for urinal/WHB with complete fitting etc 32 mm dia 60Cm long complete all as specified and directed.
S & F in repair vitreous china bowl urinal flat back size of 465 x 355 x 265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern & flush pipe) but exncluding waste pipe, complete including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with screws, pointing around urinal back in cement complete all as specified and directed.
S&F of steel ventilators with top hung double shutter glazed and gauzed and bottom half fixed glazed type including hings, steel peg stay complete all as specified and directed.
S & F in repair CP tubular towel rail 20 mm dia, ‘D’ type 60 cm long between flanges.
S & F in repair soap dish, any type, fixed to plugs with chromium plated brass screws complete.
S&F in repair PVC (SWR) floor trap 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair PVC (SWR) junction double (double T) equal or unequal with access door of bore 110mm complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 75mm bore complete all as specified and directed.
Taking down carefully existing point wiring of any description for (light, fan ,sockets bells etc) complete including fittings such as sunken boxes, switches, sockets, ceiling rose, lamp holders, brackets ,fittings, pendants, fan regulartors etc and making good the disturbed surface of walls, floors etc. all as specified and directed.
Taking down existing sub main wiring of any description and size including earth wire, batten, conduits and making good the disturbed surfaces of walls, floors etc.
M&L Point wiring for one light point/fan point/bell point controlled by one switch with two runs of 1.5 sqmm multistrand copper conductor cable PVC (FRLS) insulated sheathed copper conductor single core multi strand flexible cable and 1.50 sqmm PVC (FRLS) insulated sheathed copper conductor single core cable ( green colour) as earth lead in and including PVC rigid conduit with all fittings for concealed type on stone / brick, masonary walls, roof etc including new CI/MS sunken box of required size and all as directed by Engineer-in-Charge & 3 mm thick plastic laminated sheet for housing switches sockets, regulators etc. including cutting/running chases, pinning in and making good the disturbed surfaces to match with the existing specification, complete all as specified and directed.
All as per item No.95 but One 5 pin 5/6 Amps switch socket outlet on independent board complete all as specified and directed.
All as per item No.95 but One 5 pin 5/6 Amps switch socket outlet on same board complete all as specified and directed.
All as per item No.95 but for One 5 pin 15 / 16 Amps switch socket outlet point on independent board with 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable (green colour) as earth lead complete all as specified and directed.
M&L switch piano flush type single pole one way 5 Amps complete all as specified and directed.
M&L switch socket combination flush type 5 Amps Multipurpose 2 in 1, 3 pin/6 Amp flush type pin with porcelain base complete all as specified and directed.
M&L Switch socket combination 2 in 1 flush type universal 3 pin 6 & 16 Amps flush type complete all as specified and directed.
M&L lamp holder insulated body with back plate suitable for battern fittings complete all as specified and directed.
S&F Ceiling rose surface bakelite 65 x 50 mm 2/3 terminals complete all as specified and directed.
M&L Fan Regulator (Rotary step type, Switch/Socket type Dimmer) 230/240V, AC complete all as specified and directed.
S&F 9 W LED bulb of base B22d with color temp 6500K complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
S&F Wall mounted indoor decorative 20W LED 6000K (4 ft.), extruded aluminium batten in anodised finish with opal diffuser, IP20 heat sink provided for efficient heat dissipation and integrated electronic driver, lamp color white complete set including necessary connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed.
S & F LED light fittings, 1x10 watts bulk head luminaires etc complete with all accessories and including connecting up with three core twisted flexible PVC copper conduct cabe of 23/0.0076 from ceiling rose all as specified
S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 8 Ways, double door including taking down of existing sheet metal enclosure complete all as specified and directed at site.
All as per item No-109 above but TPN 4 way, 415 V complete all as specified and directed at site.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN/FP of current carrying capacity 40 to 100 AMP in the DB complete with connection testing and commissioning
Submain wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 4 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 2.5 Sqmm as earth lead in and including PVC conduit medium grade with all fittings suitable for concealed type and making good the disturbed wall surfaces to match with existing specification all as required at site complete with all as specified and directed.
S&F in repair bracket suitable for fixing of building security light fitting made out from 40 mm bore GI pipe, medium grade 2 metre in length, made to shape as required, fixed to pole with MS flat iron clamp of size 25x4mm duly welded, bent to shape and making holes etc complete including necessary nuts, bolts & washer etc as required and all as specified and directed.
Taking down Ceiling fan, sealing cable end, dismantling blades and removing fan and blades and refixing ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as directed at site.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead complete all as specified and directed.
S&F gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of size 20mm dia complete all as specified and directed.
S&F gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of size 25mm dia complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for laying cables in trenches and getting out in hard/dense soil complete all as directed and specified.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as all as specified and directed.
Removing excavated material of any type of soil not exceeding 50 Mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M & L for construction of valve chamber 900x900x900mm inner dimensions, brick masonary in CM 1:6, PCC base in 1:4:8 of 7.5 cm thick as in foundation, plastering 15 cm thick in CM 1:4 in inner side/ coping of chamber, MS cover 3 mm thick with hinges and locking arrangements fixed in Iron frame fabricated out of angle iron 40x40x6 mm size duly painted with two coats of synthetic enamle paint over a coat of red oxide primer including excavation/ earth work complete all as specified and directed.
Cutting existing steel tubing of size 50mm dia for alterations or additions (Each cut measured)
Screwing existing steel tubing of size 50mm dia for alterations or additions (or lengthening screw on pipe to form connector)
Material and labour for Robo Sand /M-sand for cushioning in cable trenches over & under the cables, with river washed coarse sand, as per standard practice with proper compaction complete all as specified and directed. (Note: Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I).
M&L brick protection with common burnt bricks, sub class'B' of size 230x115x75mm for cable protection complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sq mm 4 core complete all as directed and specified.
M & L for cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable/pipe all as directed and making good the road/hard standing by using old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32mm x 6mm dia by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point incl necessary earth work and excavation PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with SSR Part-II RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with water pipe GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia, light grade all as specified and directed in SSR Part II. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately.
Supplying, installing, testing and commissioning in repair factory made outdoor type LT Kiosk box with canopy of size 1000mmx600mmx450mm made out of 3.15mm thick CRCA sheet duely powder coated and locking arrangement with 4 nos 100 Amps aluminium busbar and 4 nos aluminium lugs of size 40mmx5mm of length 75 mm including grouting in PCC 1:4:8 type C-1 and taking down old unserviceable one complete all as specified and directed.
VACON INFRASTRUCTURES
Sri Associates
THE DECAN ENGINEERING AND REFRIGERATION COMPANY
Sri Lakshmi Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .