SITC of Air conditioners in Fuel Injection Pump room at Central Workshop Directorate of Transport Port Blair
2021_APWD_4141_1
07/NIT/WSD/2021-22
Open Tender
Air-Conditioner
Works
30 days
Port Blair
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
Exempted
4 Dec 2021
22 Oct 2021
2 Nov 2021
22 Oct 2021
2 Nov 2021
26 Oct 2021
22 Oct 2021 - 2 Nov 2021
Amount
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Triple pole and neutral
Supply and fixing of MCB enclosure of sheet steel, phosphatisd,power painted MCB DB,s with Din rail ( in accordance with IS 1302, IS8623, IEC/BSEN 60439-3). Of 4 ways Havells CAT NO DHDESFP or equivalent
SITC of 04 Ton capacity Floor Standing, Tower type, 3 Phase,415V) Air conditioner unit with cooling capacity of 48000 BTU with R-32/R-410 refrigerant gas,MAKE: VOLTAS Model FAC 48 CZMM, or equivalent specification in VESTAR/ MITSUBISHI/Cruise.(With copper condenser coil).
Providing and fixing of refrigerant copper pipes of following sizes (Suction & delivery) of split type AC i/c providing electrical cables, insulation, extra gas charging , cutting, drilling holes on the wall for passing gas pipes , fixing suitable size PVC pipe on the wall through the holes and cementing, painting to give an even look and smooth finish and covering with PVC non adhessive tape over the insulation of refrigerant pipes and as per the direction of E-in-C
Refrigerant pipes of Sizes 3/4" & 1/2"
Fabrication of stand/Pedestal for keeping the indoor/out door unit of split type AC of various capacity made of suitable size of M S Angle and painting with one coat of red oxide and paint as required.
ROYAL ENGINEERING WORKS
TROPICAL REFRIGERATION
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .