Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹3,300
Closing Date
30 Sept 2026, 5:00 pm4d left
Executive Engineer, PWD, Electrical Division, MDU
O/o the Executive Engineer, PWD., Electrical Division, Tallakulam, Madurai - 625 002
Improvements by Supply and renewal of 1No. of Cubical type 800A MV Panel in existing HT SC No.11 in Government Rajaji Hospital at Madurai.
2026_PWD_704828_1
12/DB/JDO-2/C-26/2026-11/Dt 15.09.2026
Open Tender
Electrical Works
Lump-sum
45 days
Government Rajaji Hospital
No
3 documents required · 3 mandatory
₹0
₹3,300
16 Sept 2026
16 Sept 2026
1 Oct 2026
16 Sept 2026
30 Sept 2026
16 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, fabrication, erection and comissioning of 800A capacity dust and vermin proof cubical panel board of suitable size made up of 16 SWG CRCA sheet steel for outer body, with doors, switch supports and seperations etc., and with supply and fixing of the following interior switch with bus bar chamber complete with
2"x1/2" tinned cu. Flat for 3 phases & neutral and earth connections with bus bar insulators complete with the following tinned Cu. flat should be used between busbar and switches : 2"x1/2" tinned cu. flat for interconnection of 1No 800A incoming switch to bus bar, 1"x1/2" tinned cu. flat for interconnection of 2Nos 400A incoming switch to bus bar, 1"x1/4" tinned cu. flat for interconnection of 6Nos 250A incoming switch to bus bar, 1"x1/8" tinned cu. flat for interconnection of 2nos 125A switch to bus bar, and including supply and fixing of multifunction meter (VAF) with suitable CT –coil, selector switches & indication lamps with HRC fuses connections complete etc. The panel should be fabricated as per CEIG specification.The housing accommodate 11Nos 3 phase switches and supply and fixing of the following switches. | 1 | No | 2,76,692 | ₹2,76,692 |
| 2 | 1. 800 A TPN switch disconnector fuse units interior only with HRC fuses double break - 1No
2. 400 A TPN switch disconnector fuse units interior only with HRC fuses double break - 2Nos
3. 250A TPN switch disconnector fuse units interior only with HRC fuses double break - 6Nos.
4. 125A TPN switch disconnector fuse units interior only with HRC fuses double break - 2Nos. | - | - | - | - |
| 3 | In each cubical switch, live portion of bus bar should be shrouded by 6mm thick hylem sheet sepearator, and properly earthed by tinned solid copper flat as per CEIG specifications. All the doors should be provided with suitable locking arrangement with rubber beedings. The earth bus with two runs of 1"x1/4" tinned copper flat must be run all round the panel to provide double earth connection.
The panel should be painted with two high quality enamel paint over one coat of red oxide primer, the cable size, capcity of switch, loaction etc., should be superscribed with white paint and metallic danger board shall be affixed complete with mounting on base channel 3"x11/2"x1/2" iron frame work support complete (The TPN switches should be LK / Siemens / Eq) | - | - | - | - |
| 4 | GST@ 18%(mailto:GST@%2018%25塹ᴻ䡿ⲯ嶂藄挧ꮥ) | 0.18 | times | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
tenderno140conditions.pdf
Tender Documents • 0.93 MB
BOQ_847241.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .