Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹60.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹61.7 L+₹80,610 (1.32%)Admitted-Finance UDHAMPUR | L2 | Admitted-Finance | |
| 3 | L3₹63.5 L+₹2.6 L (4.32%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹64.8 L+₹3.9 L (6.46%)Admitted-Finance TEHSIL TRINTHA DISTRICT REASI 182311 JAMMU AND KASHMIR | REASI | JAMMU AND KASHMIR | 182311 | L4 | Admitted-Finance | |
| 5 | L5₹66.3 L+₹5.4 L (8.95%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | vijay builders L8 | JAI CHANDI MAA ENTERPRISES L1 | M/S VAISHNO TRADERS L2 | Sharma Enterprises L6 | M/S RATHER CONSTRUCTIONS AND TRADERS L7 | M/S SURAJ PARTAP SINGH L4 | VEENA CONSTRUCTION CO. L5 | M R ENGINEERS & TRADERS L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Rabbit Conductor at WSS Laddan kalid Sulghar Stage-I. | |||||||||||
| 1.01 | 9 mtr. Long ST Pole (ST-410 SP-33) | 16 | No. | 32,000 ₹3,12,000 | 16,000 ₹2,80,000 | 32,000 ₹2,72,000 Lowest | 12,800 ₹3,32,800 | 24,000 ₹2,96,000 | 4,800 ₹3,08,800 | 16,000 ₹2,72,000 Lowest | 48,000 ₹2,88,000 |
| 1.02 | GI V Cross -arm with top Bracket including clamps | 265 | Kg | 5,300 ₹39,750 | 2,650 ₹31,800 | 2,650 ₹26,500 Lowest | 1,272 ₹33,072 | 3,975 ₹33,125 | 530 ₹38,955 | 5,300 ₹39,750 | 2,650 ₹42,400 |
| 1.03 | GI Channel X-arm including clamps and Angle for braces | 150 | Kg | 3,000 ₹22,500 | 1,500 ₹18,000 | 1,500 ₹15,000 Lowest | 720 ₹18,720 | 1,500 ₹18,000 | 750 ₹21,750 | 3,000 ₹22,500 | 1,500 ₹24,000 |
| 1.04 | 11 KV GO AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical | 3 | set | 6,000 ₹36,000 | 1,500 ₹27,000 | 3,000 ₹30,000 | 1,200 ₹31,200 | 3,000 ₹33,000 | 1,500 ₹16,500 Lowest | 1,500 ₹25,500 | 3,000 ₹24,000 |
| 1.05 | 50mm² ACSR Rabbit Conductor | 2.6 | Km | 20,800 ₹1,63,800 | 2,600 ₹1,30,000 | 7,800 ₹93,600 | 5,720 ₹1,48,720 | 18,200 ₹1,43,000 | 13,000 ₹1,17,000 | 3,900 ₹1,52,100 | 5,200 ₹91,000 Lowest |
| 1.06 | PG Clamps for 30mm sq. ACSR Conductor | 10 | No | 500 ₹3,000 | 100 ₹200 | 100 ₹300 | 40 ₹1,040 | 500 ₹1,000 | 100 ₹1,600 | 50 ₹100 Lowest | 100 ₹1,100 |
| 1.07 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. | 48 | No. | 2,400 ₹14,400 | 240 ₹9,120 Lowest | 480 ₹9,600 | 576 ₹14,976 | 2,400 ₹19,200 | 2,400 ₹12,000 | 1,440 ₹11,040 | 960 ₹10,560 |
| 1.08 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting | 12 | No. | 600 ₹4,800 | 240 ₹3,240 | 120 ₹2,400 | 240 ₹6,240 | 600 ₹7,200 | 600 ₹1,800 Lowest | 360 ₹5,760 | 240 ₹3,840 |
| 1.09 | Galvanized Nuts and Bolts | 10 | Kg | 500 ₹2,000 | 100 ₹1,100 | 100 ₹1,000 Lowest | 48 ₹1,248 | 100 ₹1,700 | 500 ₹1,500 | 200 ₹1,300 | 100 ₹1,600 |
Tender Value
Refer Docs
EMD Value
₹1.8 L
Closing Date
4 Jan 2025, 3:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
Creation of 2X250 KVA . 2X63 KVA Sub stations alongwith erection of 11 KV Line on 9 mtr. ST poles, 30mm Sq ACSR Rabbit conductor . LT line on 8 mtr. ST pole at WSS Laddan Kalid Sulghar under JJM
2024_PDD_267935_1
Ed/Udh/33 of 2024-25 dt. 13-12-2024
Open Tender
Electrical Works
Turn-key
120 days
In Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
Executive Engineer Electric DivisionJPDCL
₹1.8 L
Yes
18 Jan 2025
14 Dec 2024
7 Jan 2025
14 Dec 2024
4 Jan 2025
14 Dec 2024
14 Dec 2024 - 20 Dec 2024
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Rabbit Conductor at WSS Laddan kalid Sulghar Stage-I.
9 mtr. Long ST Pole (ST-410 SP-33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
11 KV GO AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
50mm² ACSR Rabbit Conductor
PG Clamps for 30mm sq. ACSR Conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with two coat of Aluminium Paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for creation of 250 KVA Sub stn. at WSS Laddan Kalid Sulghar Stage-I.
11/0.433kV, 3-phase Distribution Transformers 250 KVA with Bimetallic Terminal Connectors Energy Level-2, Copper wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
11 kV Horn Gap Fuse Set 3 Phase 200A
RCC Foundation for transformer bed as per approved design/Drawing.
300 mm² (2ckt.) 1.1 kv Grade, PVC insulated stranded conductor FRLS type
11 Mtr. Long Pole( ST-410 SP56)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting.
GI Channel/Angle/Flat of sizes including clamps
Galvanized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber
11 KV polymeric composite Pin insulator, 12kv, 5 kn, lightening impulse 75 KV Positive and 80 KV Negative, creepage distance 320mm
LT Distribution Box for 250 KVA DTR with MCCB for incomer and SFU's for outgoing Circuits.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
PG Clamps
Danger plates with clamps
GI Barbed wire for Anti Climbing
3 phase Trivector meter with CT/PT unit
Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole
Painting of 11 mtr long ST poles with one coat of Red oxide and two coats of aluminium paint
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of LT line on 8 mtr. ST pole, 100mm² ACSR Rabbit Conductor at WSS Laddan kalid Sulghar Stage-I.
8 mtr. Long poles (ST-410 SP15)
GI M Clamps for shackle insulator
50mm² ACSR Rabbit Conductor
Shackle insualtor
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 8 mtr. Long ST poles with two coat of Aluminium paint
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Conductor at WSS Laddan Kalid Sulghar Stage-II (Baldoh).
9 mtr. Long ST Pole (ST-410 SP-33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
11 KV GO AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
50mm² ACSR Rabbit Conductor
PG Clamps for 30mm sq. ACSR Conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with two coat of Aluminium Paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for creation of 250 KVA Sub stn. at WSS Laddan Kalid Sulghar Stage-II (Baldoh).
11/0.433kV, 3-phase Distribution Transformers 250 KVA with Bimetallic Terminal Connectors Energy Level-2, Copper wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
11 kV Horn Gap Fuse Set 3 Phase 200A
300 mm² 1.1 kv Grade, PVC insulated stranded conductor FRLS type
9 Mtr. Long Pole( ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting.
GI Channel/Angle/Flat of sizes including clamps
Galvanized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber
11 KV polymeric composite Pin insulator, 12kv, 5 kn, lightening impulse 75 KV Positive and 80 KV Negative, creepage distance 320mm
LT Distribution Box for 250 KVA DTR with MCCB for incomer and SFU's for outgoing Circuits.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
PG Clamps
Danger plates with clamps
GI Barbed wire for Anti Climbing
3 phase HT Trivector meter with CT/PT unit
Cement Bottoming 1:2:4 mix as per REC Strandards 0.5 cum per pole
Painting of 9 mtr long ST poles with one coat of Red oxide and two coats of aluminium paint
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 3 Phase 4 Wire LT line on 8 mtr. ST poles at WSS Laddan Kalid Sulghar Stage-II (Baldoh).
8 mtr. Long ST poles (ST-410 SP15)
GI M Clamps for shackle insulator
50mm² ACSR Rabbit Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20mm 2.5 mtr. Long through GI Strip
Painting of 8 mtr ST poles with two coat of Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Rabbit Conductor at WSS Laddan kalid Sulghar Stage-III (Nadel).
9 mtr. Long ST Pole (ST-410 SP-33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
11 KV GO AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
50mm² ACSR Rabbit Conductor
PG Clamps for 30mm sq. ACSR Conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with two coat of Aluminium Paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Creation of 63 KVA Sub station at WSS Laddan kalid Sulghar Stage-III (Nadel).
11/0.433 KV, 3-phase distribution Transformer 63 KVA with Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & with LV Cable box having detachable Aluminium Gland plate
Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
11 KV Horn gap fuse set 3 phase 200 A
120mm² 1.1 KV Grade, PVC insulated standed conductor FRLS Type
9 mtr. long pole (ST-410 SP33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45KN, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting.
GI Channel /Angle/flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
11 KV Poloymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
LT distribution box for 63 KVA DTR with MCCB for incomer and SFU's for outgoing circuits
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
PG Clamps
Danger Plates with Clamps
GI Barbed wire for Anticlimbing
3-phase 4 wire LT Prodigy Meter with box
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Painting of ST poles 9 mtr. of sub stn. with 1 coat of Red oxide
Painting of ST poles 9 mtr. of sub stn. with 2 coat of Aluminium paint
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of LT line on 8 mtr. ST pole, 100mm² ACSR Rabbit Conductor at WSS Laddan kalid Sulghar Stage-III (Nadel).
8 mtr. Long poles (ST-410 SP15)
GI M Clamps for shackle insulator
50mm² ACSR Rabbit Conductor
Shackle insualtor
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 8 mtr. Long ST poles with two coat of Aluminium paint
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Rabbit Conductor at WSS Laddan kalid Sulghar Stage-Four (Kaldi).
9 mtr. Long ST Pole (ST-410 SP-33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
11 KV GO AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical
50mm² ACSR Rabbit Conductor
PG Clamps for 30mm sq. ACSR Conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with two coat of Aluminium Paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Creation of 63 KVA Sub station at WSS Laddan kalid Sulghar Stage-Four (Kaldi).
11/0.433 KV, 3-phase distribution Transformer 63 KVA with Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & with LV Cable box having detachable Aluminium Gland plate
Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
11 KV Horn gap fuse set 3 phase 200 A
120mm² 1.1 KV Grade, PVC insulated standed conductor FRLS Type
9 mtr. long pole (ST-410 SP33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45KN, lightening impulse 75KV Positive and 80 KV Negative, creepage distance 320mm with fitting.
GI Channel /Angle/flat of sizes including clamps
Galvinized Nuts and Bolts.
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
11 KV Poloymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
LT distribution box for 63 KVA DTR with MCCB for incomer and SFU's for outgoing circuits
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
PG Clamps
Danger Plates with Clamps
GI Barbed wire for Anticlimbing
3-phase 4 wire LT Prodigy Meter with box
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Painting of ST poles 9 mtr. of sub stn. with 1 coat of Red oxide
Painting of ST poles 9 mtr. of sub stn. with 2 coat of Aluminium paint
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of LT line on 8 mtr. ST pole, 100mm² ACSR Rabbit Conductor at WSS Laddan kalid Sulghar Stage-Four (Kaldi).
8 mtr. Long poles (ST-410 SP15)
GI M Clamps for shackle insulator
50mm² ACSR Rabbit Conductor
Shackle insualtor
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 8 mtr. Long ST poles with two coat of Aluminium paint
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
M/S VAISHNO TRADERS (BID ID -2302281)
M R ENGINEERS & TRADERS (BID ID -2299009)
M/S SURAJ PARTAP SINGH (BID ID -2298974)
VEENA CONSTRUCTION CO. (BID ID -2300876)
Sharma Enterprises (BID ID -2303888)
M/S RATHER CONSTRUCTIONS AND TRADERS (BID ID -2303128)
vijay builders (BID ID -2303598)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .